Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power system managements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Network Constraints Consideration for Grid-Edge Energy Management System

Increased deployment of distributed energy resources (DER) in distribution system is bringing need for enhanced grid intelligence, control, and flexibility. This is significant at the edge of the grid where DERs, loads or microgrids are located. Integrated DERs in a distribution system need to follow grid codes to avoid violations that results in DER disconnection. To comply with grid code requirements (e.g. IEEE 1547-2018) at the grid edge level, network constrained grid edge energy management system (GEEMS) is proposed in this paper. The objective of GEEMS is to provide economic solution for active and reactive power dispatch set-points at each interval and ensure voltage regulation to support secure interconnection of the grid edge segment to the distribution system. To evaluate the proposed GEEMS framework, four DERs are included into IEEE 13 bus system. GEEMS outperforms the existing economic dispatch-based energy management system by reducing the voltage violation.

Electric vehicle depot charging station↗

How an Autonomous Offshore Power System Can Transform the Ocean Economy - A Hypothetical Case Study Utilizing an Autonomous Offshore Power System in Northern Lights Carbon Capture and Storage Project

An Autonomous Offshore Power System (AOPS) provides in-situ power, energy storage, real-time data and communications support, asset management, and other capabilities at sea. It has applications for all offshore industries: energy, defense and security, aquaculture, science and research, and communications. Furthermore, this paper highlights how an AOPS can reduce cost, complexity, and carbon-intensity for existing offshore operations and enable new capabilities for offshore industry leaders. This new AOPS technology has two primary advantages. First, it unlocks the autonomous, electric future of the ocean economy via ‘local’ power generation and energy storage, in addition to real-time connection to the data cloud. Second, it helps enable a material change in the global energy mix through cost-effective, reliable generation and storage technology for use cases including mobile/static data-gathering and reporting systems, operating equipment, and charging networks for uncrewed surface vessels. AOPS technology will help transform the ocean economy, and thus has implications for offshore industry leaders as they push to reduce costs today and make an autonomous and decarbonized future possible.

16 TIDAL AND WAVE POWER↗

Investigation of Insulation Materials for Future Radioisotope Power Systems

NASA's Radioisotope Power Systems (RPS) Technology Advancement Project is developing next generation high-temperature insulation materials that directly benefit thermal management and improve performance of RPS for future science missions. Preliminary studies on the use of multilayer insulation (MLI) for Stirling convertors used on the Advanced Stirling Radioisotope Generator (ASRG) have shown the potential benefits of MLI for space vacuum applications in reducing generator size and increasing specific power (W/kg) as compared to the baseline Microtherm HT (Microtherm, Inc.) insulation. Further studies are currently being conducted at NASA Glenn Research Center on candidate MLI foils and aerogel composite spacers. This paper presents the method of testing of foils and spacers and experimental results to date.

Cornell, Peggy A.↗

Estimated performance and future potential of solar dynamic and photovoltaic power systems for selected LEO and HEO missions

Solar Photo Voltaic (PV) and thermal dynamic power systems for application to selected Low Earth Orbit (LEO) and High Eccentric Orbit (Energy) (HEO) missions are characterized in the regime 7 to 35 kWe. Input parameters to the characterization are varied corresponding to anticipated introduction of improved or new technologies. Comparative assessment is made between the two power system types utilizing newly emerging technologies in cells and arrays, energy storage, optical surfaces, heat engines, thermal energy storage, and thermal management. The assessment is made to common ground rules and assumptions. The four missions (space station, sun-synchronous, Van Allen belt and GEO) are representative of the anticipated range of multi-kWe earth orbit missions. System characterizations include all required subsystems, including power conditioning, cabling, structure, to deliver electrical power to the user. Performance is estimated on the basis of three different levels of component technology: (1) state-of-art, (2) near-term, and (3) advanced technologies. These range from planar array silicon/IPV nickel hydrogen batteries and Brayton systems at 1000 K to thin film GaAs with high energy density secondary batteries or regenerative fuel cells and 1300 K Stirling systems with ultra-lightweight concentrators and radiators. The system estimates include design margin for performance degradations from the known environmental mechanisms (micrometeoroids and space debris, atomic oxygen, electron and proton flux) which are modeled and applied depending on the mission. The results give expected performance, mass and drag of multi-kWe earth orbiting solar power systems and show how overall system figures of merit will improve as new component technologies are incorporated.

Bents, David J.↗

Design Lessons Learned from Temperature Management of Galileo's Retro-Propulsion Module

Launched in 1989, the Galileo mission added dramatically to our understanding of the Jovian system and our entire solar system1. To make best use of limited resources, the Galileo Orbiter used excess power from its Radioisotope Thermoelectric Generators (RTGs) for temperature management of its Retro-Propulsion Module (RPM). This paper describes operational challenges introduced by this design and how, despite major mission changes through development and flight, they were overcome through a challenging six-year interplanetary cruise to Jupiter. This case study offers lessons for missions planning to couple critical spacecraft subsystems in unconventional ways.

Gounley, Robert↗

A Briefing on Metrics and Risks for Autonomous Decision-Making in Aerospace Applications

Significant technology advances will enable future aerospace systems to safely and reliably make decisions autonomously, or without human interaction. The decision-making may result in actions that enable an aircraft or spacecraft in an off-nominal state or with slightly degraded components to achieve mission performance and safety goals while reducing or avoiding damage to the aircraft or spacecraft. Some key technology enablers for autonomous decision-making include: a continuous state awareness through the maturation of the prognostics health management field, novel sensor development, and the considerable gains made in computation power and data processing bandwidth versus system size. Sophisticated algorithms and physics based models coupled with these technological advances allow reliable assessment of a system, subsystem, or components. Decisions that balance mission objectives and constraints with remaining useful life predictions can be made autonomously to maintain safety requirements, optimal performance, and ensure mission objectives. This autonomous approach to decision-making will come with new risks and benefits, some of which will be examined in this paper. To start, an account of previous work to categorize or quantify autonomy in aerospace systems will be presented. In addition, a survey of perceived risks in autonomous decision-making in the context of piloted aircraft and remotely piloted or completely autonomous unmanned autonomous systems (UAS) will be presented based on interviews that were conducted with individuals from industry, academia, and government.

Frost, Susan↗

Extending ISS Life Beyond 2030

The United States On-orbit Segment (USOS) of the International Space Station (ISS) was designed to meet a 15-year on-orbit life. Since the first hardware was launched in late 1998, the ISS would have reached its end of life in 2013. With the realization that the ISS would be needed well into the next decade, and beyond, a multi-disciplinary effort was undertaken to extend the ISS’ life through 2028 and to show that further extension to 2040 and beyond is not only feasible but achievable. Currently, NASA and the ISS international partners have agreed to extend its operations through 2030. This collaborative effort ensures that the ISS will continue to serve as a hub for scientific research, international cooperation, and educational endeavors for the next decade. Maintaining a continuous human presence in Low Earth Orbit (LEO) is desirable for testing new LEO, lunar, and deep-space technologies; conducting scientific research in micro-gravity for the benefit of life on Earth; and enabling a seamless transition of capabilities to one or more commercially owned and operated destinations. This paper provides an overview of the ISS life extension project with a particular focus on the analytical approach used to assess the primary structure. This analytical approach includes future operations planning, critical location screening, on-orbit dynamic load simulation, on-orbit optical property degradation studies, on-orbit thermal analyses, spectra generation, crack model idealization, fracture analyses, and post processing. Structural life results and identification of the most critical on-orbit events are presented. Also addressed are life extension approaches for other affected sub-systems, including: 1. Secondary Structure. 2. Materials. Evaluations consider environmental exposure to atomic oxygen, ionizing and gamma radiation, fluids, etc. Life limited materials, wear, and usage effects are also considered. 3. Environmental Control and Life Support Systems, including oxygen supply and generation, water recovery and management, and regenerative hardware. Evaluations are performed to determine which hardware can be run to failure and which are assessed for life extension. 4. Electrical power system. ISS is powered by eight channels of solar arrays and an electrical energy storage system providing 357 kWh power. Power generation and balance analyses are performed considering hardware degradation and increasing power demand. 5. Logistics and maintenance. Analyses are performed to determine critical spares required to maintain functionality. Consideration is given to supply chain health, obsolescence issues, onboard stowage availability, and up-mass capability. The successful life extension results have built confidence to safely operate, maintain and enhance the ISS well beyond the current decade. Extending the operational life of the ISS maintains an international presence in LEO and serves to avoid a gap in capability necessary to fulfill the exploration and research needs of NASA, international partners, and industry without interruption until a commercial space station is operational.

design life↗

Thermal Management for Planar Package Power Electronics (CRADA Final Report)

The National Renewable Energy Laboratory (NREL) and John Deere Electronic Solutions (JDES) collaborated to develop and evaluate computer models and simulations related to the thermal performance of semiconductor device packaging for an inverter of an off-road vehicle ("Semiconductor Packaging"). The objective of the research was for NREL and JDES to develop a two or three-dimensional computer-aided design model of the Semiconductor Packaging ("Computer Model") for thermal performance evaluation in a simulation. The project developed computer models of a Semiconductor Package of silicon-carbide semiconductor devices with appropriate thermal dissipation via one or more of the following thermal features: a double-sided planar cooling configuration, an air-cooled configuration, a liquid-cooled configuration for off-road inverter applications in a relevant simulated operating environment. It is noted that surface area and prototype product embodiment consisting of air-cooled and liquid-cooled configurations may and may not be in direct contact with power semiconductor chips. The idea was to explore and develop packaging and thermal management technology for power semiconductors that was most effective in the performance yet had least burden in overall product cost for a given application.

33 ADVANCED PROPULSION SYSTEMS↗

Data and code repository for "How do the weather regimes drive wind speed and power production at the sub-seasonal to seasonal timescales over the CONUS?"

There has been an increasing need for forecasting power generation at the sub-seasonal to seasonal (S2S) timescales to support the operation, management, and planning of the wind-energy system. At the S2S timescales, atmospheric variability is largely related to recurrent and persistent weather patterns, referred to as weather regimes (WRs). In the study "How do the weather regimes drive wind speed and power production at the sub-seasonal to seasonal timescales over the CONUS?", we identify four WRs that influence wind resources over North America using a self-organizing map (SOM) algorithm. These WRs are responsible for large-scale wind and power production anomalies over the CONUS at the S2S timescales. The WR-based reconstruction explains up to 50% of the monthly variance of power production over the western United States, and the explanatory power generally increases with the increase of timescales. The identified relationship between WRs and power production reveals the potential and limitations of the regional WR-based wind resource assessment over different regions of the CONUS across multiple timescales. This repository includes all the data and codes we use for analyses in this study. Users may use them to reproduce the results of this study on their end.

17 WIND ENERGY↗

A Path to 100 Percent Renewable Energy: Grid-Forming Inverters will Give Us the Grid We Need Now

This is a more urgent problem than it might sound. The westernmost Hawaiian island of significant size, Kauai is home to around 70,000 residents and 30,000 tourists at any given time. Renewable energy accounts for 70 percent of the energy produced in a typical year - a proportion that's among the highest in the world and that can be hard to sustain for such a small and isolated grid. During the day, the local system operator, the Kauai Island Utility Cooperative, sometimes reaches levels of 90 percent from solar alone. But on 2 April, the 26-MW generator was running near its peak output, to compensate for the drop in solar output as the sun set. At the moment when it failed, that single generator had been supplying 60 percent of the load for the entire island, with the rest being met by a mix of smaller generators and several utility-scale solar-and-battery systems.

battery management systems↗

Design Considerations of DC/DC Regulator for High-Power Dynamic Wireless Charging Systems

Due to fast fluctuating input voltage, dynamic wireless charging requires a post-regulator stage for battery charging control and management. This regulator stage has a high requirement on efficiency, size as well as control performance to ensure tight regulation and fast trainset. This paper addresses the control challenges by modeling the system and designing the compensator with input voltage feedforward control. In addition, high resolution PWM is implemented to improve transient performance and current balancing among the phases. Experimental results prove the effectiveness of the proposed schemes and validates 180 kW closed-loop 4-phase operation at 99% efficiency.

Xue, Lincoln↗

Off Grid Photovoltaic Wastewater Treatment and Management Lagoons

The SSC wastewater treatment system is comprised of key components that require a constant source of electrical power or diesel fuel to effectively treat the wastewater. In alignment with the President's new Executive Order 13653, Planning for Federal Sustainability in the Next Decade, this project aims to transform the wastewater treatment system into a zero emissions operation by incorporating the advantages of an off grid, photovoltaic system. Feasibility of implementation will be based on an analytical evaluation of electrical data, fuel consumption, and site observations.

LaPlace, Lucas A.↗

Performance of a Regenerative Fuel Cell System for the Lunar Surface

Regenerative fuel cells (RFCs) are an attractive energy storage solution for lunar missions as a technology capable of providing a higher specific energy (i.e., W∙h/kg) than state-of-the-art packaged Li-ion battery systems. An RFC consists of the (1 & 2) electrochemical stacks (chemical to electrical energy conversion to supply electricity to an external load, i.e. the fuel cell reaction, and electrical to chemical energy conversion of supplied electrical power to dissociate water into hydrogen and oxygen gases, i.e. water electrolysis), (3) fluidic conditioning, (4) reactant storage, (5) avionics, (6) power management and distribution (PMAD), and (7) thermal management. NASA’s Glenn Research Center has designed, assembled, and tested a breadboard RFC sys-tem capable of operating autonomously for multiple simulated lunar day/night cycles in a laboratory environment. The system is comprised of a non-flow through proton exchange membrane (PEM) fuel cell stack and a liquid-anode feed PEM electrolyzer (EZ) stack designed to electrochemically compress the reactants at balanced pressures up to 12.4 MPa (1800 psia). The fluidic conditioning, avionics, PMAD, and thermal management sub-systems are largely comprised of commercial-off-the-shelf components for this system-level development effort. The hardware is controlled by a CubeSat space processor running an operational program based on core flight architecture that can control the RFC hardware autonomously through a state machine with fault monitoring. The testing results highlighted here were completed with the system in an open-loop configuration such that reactants generated through water electrolysis were vented while gas cylinders supplied fuel cell operation. The breadboard operated autonomously, but there were five unplanned transitions to a safe state that required a manual restart after reviewing the data, determining a root cause, and implementing a solution. Four of the transitions were caused by the thermal management subsystem and the fifth was caused by a water management control issue in the EZ sub-system. The RFC system operated for over 550 hours with the final cycle being slightly abbreviated due to reasons unrelated to system performance.

Kerrigan Cain↗

Performance of a Regenerative Fuel Cell System for the Lunar Surface

Regenerative fuel cells (RFCs) are an attractive energy storage solution for lunar missions as a technology capable of providing a higher specific energy (i.e., W∙h/kg) than state-of-the-art packaged Li-ion battery systems. An RFC consists of the (1 & 2) electrochemical stacks (chemical to electrical energy conversion to supply electricity to an external load, i.e. the fuel cell reaction, and electrical to chemical energy conversion of supplied electrical power to dissociate water into hydrogen and oxygen gases, i.e. water electrolysis), (3) fluidic conditioning, (4) reactant storage, (5) avionics, (6) power management and distribution (PMAD), and (7) thermal management. NASA’s Glenn Research Center has designed, assembled, and tested a breadboard RFC sys-tem capable of operating autonomously for multiple simulated lunar day/night cycles in a laboratory environment. The system is comprised of a non-flow through proton exchange membrane (PEM) fuel cell stack and a liquid-anode feed PEM electrolyzer (EZ) stack designed to electrochemically compress the reactants at balanced pressures up to 12.4 MPa (1800 psia). The fluidic conditioning, avionics, PMAD, and thermal management sub-systems are largely comprised of commercial-off-the-shelf components for this system-level development effort. The hardware is controlled by a CubeSat space processor running an operational program based on core flight architecture that can control the RFC hardware autonomously through a state machine with fault monitoring. The testing results highlighted here were completed with the system in an open-loop configuration such that reactants generated through water electrolysis were vented while gas cylinders supplied fuel cell operation. The breadboard operated autonomously, but there were five unplanned transitions to a safe state that required a manual restart after reviewing the data, determining a root cause, and implementing a solution. Four of the transitions were caused by the thermal management subsystem and the fifth was caused by a water management control issue in the EZ sub-system. The RFC system operated for over 550 hours with the final cycle being slightly abbreviated due to reasons unrelated to system performance.

Kerrigan Cain↗

A Hybrid Power Management (HPM) Based Vehicle Architecture

Society desires vehicles with reduced fuel consumption and reduced emissions. This presents a challenge and an opportunity for industry and the government. The NASA John H. Glenn Research Center (GRC) has developed a Hybrid Power Management (HPM) based vehicle architecture for space and terrestrial vehicles. GRC's Electrical and Electromagnetics Branch of the Avionics and Electrical Systems Division initiated the HPM Program for the GRC Technology Transfer and Partnership Office. HPM is the innovative integration of diverse, state-of-the-art power devices in an optimal configuration for space and terrestrial applications. The appropriate application and control of the various power devices significantly improves overall system performance and efficiency. The basic vehicle architecture consists of a primary power source, and possibly other power sources, providing all power to a common energy storage system, which is used to power the drive motors and vehicle accessory systems, as well as provide power as an emergency power system. Each component is independent, permitting it to be optimized for its intended purpose. This flexible vehicle architecture can be applied to all vehicles to considerably improve system efficiency, reliability, safety, security, and performance. This unique vehicle architecture has the potential to alleviate global energy concerns, improve the environment, stimulate the economy, and enable new missions.

Eichenberg, Dennis J.↗

Solar Power System Evaluated for the Human Exploration of Mars

The electric power system is a crucial element of any mission for the human exploration of the Martian surface. The bulk of the power generated will be delivered to crew life support systems, extravehicular activity suits, robotic vehicles, and predeployed in situ resource utilization (ISRU) equipment. In one mission scenario, before the crew departs for Mars, the ISRU plant operates for 435 days producing liquefied methane and oxygen for ascent-stage propellants and water for crew life support. About 200 days after ISRU production is completed, the crew arrives for a 500-day surface stay. In this scenario, the power system must operate for a total of 1130 days (equivalent to 1100 Martian "sols"), providing 400 MW-hr of energy to the ISRU plant and up to 18 kW of daytime user power. A photovoltaic power-generation system with regenerative fuel cell (RFC) energy storage has been under study at the NASA Glenn Research Center at Lewis Field. The conceptual power system is dominated by the 4000- m2 class photovoltaic array that is deployed orthogonally as four tent structures, each approximately 5 m on a side and 100-m long. The structures are composed of composite members deployed by an articulating mast, an inflatable boom, or rover vehicles, and are subsequently anchored to the ground. Array panels consist of thin polymer membranes with thin-film solar cells. The array is divided into eight independent electrical sections with solar cell strings operating at 600 V. Energy storage is provided by regenerative fuel cells based on hydrogen-oxygen proton exchange membrane technology. Hydrogen and oxygen reactants are stored in gaseous form at 3000 psi, and the water produced is stored at 14.7 psi. The fuel cell operating temperature is maintained by a 40-m2 deployable pumped-fluid loop radiator that uses water as the working fluid. The power management and distribution (PMAD) architecture features eight independent, regulated 600-Vdc channels. Power management and distribution power cables use various gauges of copper conductors with ethylene tetrafluoroethylene insulation. To assess power system design options and sizing, we developed a dedicated Fortran code to predict detailed power system performance and estimate system mass. This code also modeled the requisite Mars surface environments: solar insolation, Sun angles, dust storms, dust deposition, and thermal and ultraviolet radiation. Using this code, trade studies were performed to assess performance and mass sensitivities to power system design parameters (photovoltaic array geometry and orientation) and mission parameters (landing date and landing site latitude, terrain slope, and dust storm activity). Mission analysis cases were also run. Power results are shown in this graph for an analysis case with a September 1, 2012, landing date; 18.95 North latitude landing site; two seasonal dusts storms; and tent arrays. To meet user load requirements and the ISRU energy requirement, an 8-metric ton (MT) power system and 4000-m2 photovoltaic array area were required for the assumed advanced CuInS2 thin-film solar cell technology. In this figure, the top curve is the average daytime photovoltaic array power, the middle curve is average daytime user load power, and the bottom curve is nighttime power. At mission day 1, daytime user power exceeds 120 kW before falling off to 80 kW at the end of the mission. Throughout the mission, nighttime user power is set to the nighttime power requirement. In this analysis, "nighttime" is defined as the 13- to 15-hr period when array power output is below the daytime power requirement. During dust storms, power system capability falls off dramatically so that by mission day 900, a daily energy balance cannot be maintained. Under these conditions, the ISRU plant is placed in standby mode, and the regenerative fuel cell energy storage is gradually discharged to meet user loads.

Kerslake, Thomas W.↗

Subscale Hardware-In-The-Loop Results for Hybrid Electric Turbofan Controls Use Cases

NASA is investigating hybrid electric turbine engine systems for commercial transport aircraft due to the potentially significant improvements hybrid electric technology offers in performance, fuel consumption, and operational and design flexibility. Recently, the technology has been tested at full scale in partnership with industry and advanced to Technology Readiness Level 4. This presentation will focus on a recent subscale hardware-in-the-loop test of an open source turbofan engine model developed by NASA. The Advanced Geared Turbofan 30,000 lbf – electrified (AGTF30-e) engine is used as a reference model to demonstrate control system design and use cases for an example mild hybrid electric system with no large-scale energy storage. This model is run in real-time in NASA’s Hybrid Propulsion Emulation Rig (HyPER) and is used to drive an emulation of the turbomachinery system using subscale electric machines. This dynamic scaled shaft emulation interacts with a subscale (<100 kW) hybrid system consisting of electric machines, motor controllers, and a programmable electronic load. Specific use cases demonstrated include the use of Turbine Electrified Energy Management to improve operation during transients, megawatt-scale power extraction from the AGTF30-e, and power transfer between engine spools. Results related to the effectiveness of hybrid systems are qualitatively compared to results from industry testing.

Hybrid↗

Test and evaluation of load converter topologies used in the Space Station Freedom Power Management and distribution DC test bed

Power components hardware in support of the Space Station Freedom dc Electrical Power System were tested. One type of breadboard hardware tested is the dc Load Converter Unit, which constitutes the power interface between the electric power system and the actual load. These units are dc to dc converters that provide the final system regulation before power is delivered to the load. Three load converters were tested: a series resonant converter, a series inductor switchmode converter, and a switching full-bridge forward converter. The topology, operation principles, and tests results are described, in general. A comparative analysis of the three units is given with respect to efficiency, regulation, short circuit behavior (protection), and transient characteristics.

Lebron, Ramon C.↗