At least 1,189 records · Page 66

Fault Clearing Operation in Low-Frequency High-Voltage AC Systems

Abstract—Low-frequency high-voltage ac (LF-HVac) system has been proposed as an alternative to HVdc and HVac systems to reduce transmission losses and improve grid flexibility. LF-HVac system employs back-to-back (BTB) converters to interconnect and control the voltage and power interchange between two power grid operating at different frequencies. While there are multiple studies on LF-HVac system in the literature, the fault clearing method in the LF-HVac system has not been analyzed. Therefore, this paper focuses on fault clearing operation in LFHVac system and proposes a novel method to reduce fault current by changing operating frequency of power source and converter. The performance of the proposed method is validated using detailed models of BTB converters developed in PSCAD/EMTDC. The ability to change operating frequency at the onset of a fault condition allows breakers to rapidly clear the fault and recloses. The results obtained by using the proposed method substantially diminish the fault current.

Kim, Woosung↗

Distributed Automatic Generation Control Considering DPV Using T&D Dynamic Co-Simulation

The increasing adoption of distributed energy resources (DERs) over the last decade warrants a reconsideration of control of generation resources. This paper proposes a distributed Automatic Generation Control (AGC) using transmission-and-distribution (T&D) dynamic co-simulation framework for the efficient DPV frequency regulation services. The co-simulation framework allows AGC units to exchange the information for distributed AGC, based on their adopted communication network topology. As a result, a cost-effective automatic generation control is achieved with DPV and conventional generators. The proposed distributed AGC is based on the gossip algorithm in which the neighboring AGC units share the relevant local information with each other and updates their share of AGC regulation signal. Distributed photovoltaics (DPV) unit contribute to AGC response based on their headroom capacity via DER aggregators. The algorithm is tested on IEEE-14 bus transmission system under conditions of generation failure and random load variation to observe effective frequency regulations service offered by DPVs and other AGC units. The study shows that DPV can effectively participate in AGC with the proposed distributed control framework.

automatic generation control↗

Continuous Purification of Molten Chloride Salt: Electrochemical Behavior of MgOHCl Reduction

We present a study on the electrochemical behavior of magnesium hydroxide (MgOH + ) reduction on a tungsten (W) cathode in molten chloride salt (MgCl 2 -KCl-NaCl) across the temperature range of 475 °C–525 °C. MgOH + , which forms within the salt upon exposure to moisture, is a leading cause of corrosion. Corrosion is a major barrier to deployment of chloride salts across a number of applications, including concentrating solar power plants and nuclear power plants. While pre-purification protocols have been developed to ensure MgOH + is removed from molten chloride salts prior to deployment, MgOH + forms in situ during operation of chloride-salt based plants. Thus, methods for continuous purification during plant operation are needed. Continuous electrochemical purification via electrolysis using a Mg anode and W cathode has been proposed, but little has been done to assess scalability. Here, we assess fundamental properties of electrochemical removal of MgOH + to enable future scale up of this method.

14 SOLAR ENERGY↗

HIDES (Hybrid Intrusion Detection for Energy Systems) [SWR-19-65]

Hybrid Intrusion Detection for Energy Systems (HIDES) is a conglomerate detector that incorporates three major components: (1) Signature-based detection that involves information technology (IT) related anomaly detection rules, (2) Behavior-based detection that utilizes specially crafted rulesets for detecting abnormal behavior regarding the power system's supervisory control and data acquisition (SCADA) communication streams, and (3) Learning-based detection that combines SCADA communication with phasor measurements to identify otherwise non-detectible attack vectors. The software itself interconnects intrusion detection engine (IDE) enabling communications between the generated OT and IT alerts with phasor measurements for the learning-based detection system. The resulting detection system can detect a wide array of IT, OT, and physical attacks in a real-time setting.

Rivera, Joshua↗

Autonomous Anomaly Detection For Continuous Streams

The code implements the Isolation Forest (IFML) algorithm within the digital twin (DT) of the AGN-201 nuclear reactor. The DT captures real-time operational data including control rod positions, reactor power, and temperature. The IFML model isolates anomalies by detecting patterns that deviate from expected operational behavior. The algorithm recursively partitions the data and assigns anomaly scores based on the isolation of rare and different events. By tuning parameters specific to the reactor’s operational data, the IFML identifies deviations such as unauthorized material insertions or reactor reactivity shifts. The system streams data using LabView and integrates with the DeepLynx data warehouse for anomaly processing.

Trevino, Eduardo↗

Adaptive shape control of wavefront-preserving X-ray mirrors with active cooling and heating

This article describes the development and testing of a novel, water cooled, active optic mirror system (called “REAL: Resistive Element Adjustable Length”) that combines cooling with applied auxiliary heating, tailored to the spatial distribution of the thermal load generated by the incident beam. This technique is theoretically capable of sub-nanometer surface figure error control even at high power density. Tests conducted in an optical metrology laboratory and at synchrotron X-ray beamlines showed the ability to maintain the mirror profile to the level needed for the next generation storage rings and FEL mirrors.

42 ENGINEERING↗

Hamiltonian Truncation Effective Theory

Hamiltonian truncation is a non-perturbative numerical method for calculating observables of a quantum field theory. The starting point for this method is to truncate the interacting Hamiltonian to a finite-dimensional space of states spanned by the eigenvectors of the free Hamiltonian H_0 H 0 with eigenvalues below some energy cutoff E_\text{max} E max . In this work, we show how to treat Hamiltonian truncation systematically using effective field theory methodology. We define the finite-dimensional effective Hamiltonian by integrating out the states above E_\text{max} E max . The effective Hamiltonian can be computed by matching a transition amplitude to the full theory, and gives corrections order by order as an expansion in powers of 1/E_\text{max} 1 / E max . The effective Hamiltonian is non-local, with the non-locality controlled in an expansion in powers of H_0/E_\text{max} H 0 / E max . The effective Hamiltonian is also non-Hermitian, and we discuss whether this is a necessary feature or an artifact of our definition. We apply our formalism to 2D \lambda\phi^4 λ ϕ 4 theory, and compute the the leading 1/E_\text{max}^2 1 / E max 2 corrections to the effective Hamiltonian. We show that these corrections nontrivially satisfy the crucial property of separation of scales. Numerical diagonalization of the effective Hamiltonian gives residual errors of order 1/E_\text{max}^3 1 / E max 3 , as expected by our power counting. We also present the power counting for 3D \lambda \phi^4 λ ϕ 4 theory and perform calculations that demonstrate the separation of scales in this theory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Gearbox Reliability Collaborative 1.5 (GRC1.5) Project: Joint Industry Megawatt Scale Gearbox Field Tests: Cooperative Research and Development (Final Report) CRADA Number CRD-16-00608

A new DOE/NREL industry collaboration called the Gearbox Reliability Collaborative 1.5 (GRC1.5) will undertake field testing on a commercial multi-megawatt wind turbine gearbox to collect loading data as installed in the turbine to thoroughly characterize gearbox loads and responses during actual in-field conditions. A chief outcome is to provide publicly available operational loading data to the industry. This will provide a greater understanding of steady-state, transient, and fault response for both the input and output of the gearbox; thus, facilitating improvements in the gearbox components, lubrication system, power converter or turbine controller.

17 WIND ENERGY↗

Drivetrain Reliability Collaborative 1.5 (DRC1.5) Project: Joint Industry Megawatt Scale Gearbox Field Tests: Cooperative Research and Development (Final Report) CRADA Number CRD-17-00702

A new Department of Energy (DOE)/NREL industry collaboration called the Drivetrain Reliability Collaborative 1.5 (DRC1.5) will undertake field testing on a commercial multi-megawatt wind turbine drivetrain to collect loading data as installed in the turbine to thoroughly characterize drivetrain loads and responses during actual in-field conditions. A chief outcome is to provide publicly available operational loading data to the industry. This will provide a greater understanding of steady-state, transient, and fault response for both the input and output of the drivetrain; thus, facilitating improvements in the drivetrain components, lubrication system, power converter or turbine controller.

17 WIND ENERGY↗

Cyber-Attack Detection and Accommodation for the Energy Delivery System

The goals of this project were to create a software system with a suite of key algorithms for cyber-attack detection and accommodation providing domain layer protection for critical power generation assets. Example assets included gas and steam turbines, heat recovery steam generators, and electrical generators. The aggressive algorithm goals were aimed at reducing the false positive rates in threat detection to <1% using learnings from many evolving disciplines (power turbine and generator physics, power system modeling, modern control theory, system identification, machine learning, deep learning, mathematics and data science). Additional goals for the algorithms involved localizing threats on-the-fly to know in which monitoring node the effects of attacks are present, and then providing accommodation to keep the system running uninterrupted much of the time in the presence of the attack. Accommodation had a performance goal of providing resiliency when up to 50% of monitoring nodes are in an attack state.

cybersecurity, cyber-physical↗

Transient Efficiency Flexibility and Reliability Optimization of Coal-Fired Power Plants (Reduced Order Model Development Report)

This document pertains to the reporting requirements of DOE contract FE-0031767. The document covers the development of a reduced order model library that can be used to represent coal-fired power plants. The models are transient and physics-based. Model classes in the library that correspond to different components in CFPPs are presented with physical explanations and representative results. Also, the use of the library to build an overall model for a representative CFPP is presented along with simulation results.

20 FOSSIL-FUELED POWER PLANTS↗

Transient Efficiency Flexibility and Reliability Optimization of Coal-Fired Power Plants (Model-Based Estimation Library Report)

This document pertains to the reporting requirements of DOE contract FE-0031767. The document covers the development of a model-based estimation (MBE) library for generating digital twins of coal-fired power plants (CFPPs). The models used by the MBE are transient and physics-based. Model classes in the library that correspond to different components in CFPPs are presented with physical explanations and representative results. MBE library provides Extended Kalman Filter (EKF), and Unscented Kalman Filter (UKF) algorithms. The MBE library is generic and can be used to represent a variety of CFPPs. A digital twin of a CFPP will be created as the reduced-order model of that CFPP is embedded in the developed MBE architecture.

20 FOSSIL-FUELED POWER PLANTS↗

Multi-Port Autonomous Reconfigurable Solar Power Plant

As the penetration level of power electronics increases and remote photovoltaic (PV) generation is integrated into the alternating current (ac) grid, the short-circuit ratio (SCR) at the point of interconnection of a hybrid PV–energy storage system (ESS) plant may be low. Additionally, the inertia of the alternating current (ac) grid may be low. The low SCRs and inertias can lead to reliability challenges in the power grid. These operating conditions require additional reinforcements, such as synchronous condensers, static var compensators, static synchronous compensators, and high-voltage direct current (HVdc) links/grids. HVdc links or grids may also provide the additional capability of connecting the plant to asynchronous grids and/or connecting asynchronous grids, among others. This scenario leads to discrete development of solar inverters, energy storage inverters, HVdc converters, and several transformers. Some of the problems associated with this discrete development and inverter-based generation include increased cost, lower reliability, and reduced efficiency associated with duplication of power electronics (PEs); competing controls of several individual discrete inverter-based generators due to the presence of multiple PEs, which leads to derating of the system; and transient stability problems arising from inverter-based generation, such as voltage/frequency events leading inverter shutdowns, voltage instability and control interactions in the formed weak grid, and harmonics caused by resonances of multiple inverters.

14 SOLAR ENERGY↗

A Guide to Case Studies of Grid Enhancing Technologies

This document has been developed as a resource for the electric power industry to rapidly understand the scale and history with which certain new technologies have been installed on or otherwise simulated to impact the transmission system. This document is attempting to address the findings of the 2022 U.S. Department of Energy (DOE) Report "Grid Enhancing Technologies: A Case Study on Ratepayer Impact", which identified the need for workforce development and training materials to transition new technologies from a state of “pilots” and “case studies” to “business-as-usual.” The authors go beyond typical survey-style literature reviews in that the key details and notes about each project are identified. Still, as will become evident, there is a need for more work to be done to increase the industry’s public knowledge on important topics related to the implementation of grid enhancing technology on the transmission system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

TOGETs Overview

The Transmission Optimization with Grid Enhancing Technologies (TOGETs) project will guide future research to fill in gaps on publicly available knowledge of Grid Enhancing Technologies (GETs) and conduct a full scale, multi-faceted field exercise. Ultimately the project aims to test, verify and validate deployed GETs in a transmission system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SOLAr Critical Infrastructure Energization (SOLACE): Leveraging Distributed Energy Resources to Provide Local Power

This document is a technical report based on a large-scale DOE-funded project conducted between 2019 and 2022. The project, called SOLAr Critical infrastructure Energization (SOLACE), is aimed at leveraging distributed energy resources (DERs) to provide local power to communities, feeders, or other regions. The project included a particular focus on high-value critical loads such as municipal water supply, telecommunication hubs, and disaster shelters. The key developments of the project were: (1) A comprehensive pre-event power system analysis methodology that identifies and characterizes the viable local power options. (2) A DMS-based example control system for activating and operating the local power solution during a time of crisis. (3) Grid-forming inverter technology to enable isolated local power operation and black-starting. (4) Cyber-security considerations for isolated systems when wider-area communication may be offline. This report describes the overall process that identifies and assesses the viable DER-based local power solutions for a given facility, region, or community. The report documents the process, including the key analysis steps, tools required, data requirements, and recommended pass/fail criteria for each step. It also provides a sample implementation of this process through a test case. Finally, it provides details of how a viable pre-event plan can be selected and activated at go-time when an event has occurred.

14 SOLAR ENERGY↗

Summary of Technical Peer Review on the Risk Assessment Framework proposed in Report INL/RPT-22-68656 for Digital Instrumentation and Control Systems

This report summarizes the peer review activities initiated by Idaho National Laboratory (INL) during fiscal year (FY) 2023 for the evaluation and improvement of the methodology developed under the U.S. Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) Program, Risk Informed Systems Analysis (RISA) Pathway, digital instrumentation and control (DI&C) risk assessment project. In FY 2019, the RISA Pathway initiated a project to develop a risk assessment strategy for delivering a technical basis to support effective and secure DI&C technologies for digital upgrades/designs. A framework was proposed for this strategy, which aims to (1) provide a best-estimate, risk-informed capability to quantitatively and accurately estimate the risk impact of plant modernization, considering the introduction of high safety-significant safety-related (HSSSR) DI&C systems, (2) support and supplement existing risk-informed DI&C design guides by providing quantitative risk information and evidence, (3) offer a capability of design architecture evaluation of various DI&C systems, (4) assure the long-term safety and reliability of HSSSR DI&C systems, and (5) reduce uncertainty in costs and support integration of DI&C systems in the plant. The R&D efforts of this project from FY 2019 through FY 2022 were focused on methodology improvement and demonstration of the proposed framework for the risk assessment and design optimization of safety-critical DI&C systems. Collaborations with the nuclear industry have been initiated to support the reliability and risk assessment of their DI&C systems by using the proposed framework. In FY 2023, the framework has reached to a point for a technical peer review and obtain stakeholder feedback. This peer review activity includes coordination of the reviews performed by a group of industry stakeholders, documentation of the peer review suggestions, providing resolutions and responses to the peer review comments. The objective of this technical peer review is to obtain representative feedback on the proposed framework to improve the technical qualities of its methodology and readiness for deployment to the industry. Feedback may identify potential areas for improvement and further development. The Subject Matter experts were invited to review the latest project report documenting the methodology developed in the project and provide evaluations of the technical qualities of the proposed framework and relevant methods. The reviewed project report is “An Integrated Framework for Risk Assessment of High Safety-significant Safety-related Digital Instrumentation and Control Systems in Nuclear Power Plants: Methodology and Demonstration” INL/RPT-22-68656 (short as “INL/RPT-22-68656” in this report). This peer review report documents the technical questions provided for technical peer review and introduces the technical peer reviewers from the stakeholders including nuclear utilities, regulators, and universities. Comments from technical peer reviewers and the resolutions and responses to these comments are outlined. Insights and lessons learned from the technical peer review are summarized in conclusions and future work. The primary audience of this report are DI&C designers, engineers, and probabilistic risk assessment (PRA) practitioners. This includes stakeholders, such as the nuclear utilities and regulators who consider the deployment and upgrade of DI&C systems, DI&C software developers and reviewers, and cybersecurity specialists.

99 GENERAL AND MISCELLANEOUS↗

GRC1.5 Project: Joint Industry Megawatt Scale Gearbox Field Tests (Final Report)

A new DOE/NREL industry collaboration called the Gearbox Reliability Collaborative (GRC) 1.5 will undertake field testing on current commercial multi-megawatt wind turbine gearboxes to collect loading data from installed turbines to thoroughly characterize gearbox input loads and responses during actual in-field conditions. A chief outcome is to provide operational loading data relative to the most common failure modes. This will provide a greater understanding of steady-state, transient, and fault response for both the input and output of the gearbox, thus facilitating improvements in the gearbox, power converter or turbine controller.