Projector Selection for SOFAST Testing

In Concentrating Solar Power (CSP) there is a need for mirrors that are optically accurate, as they are used to focus light onto a receiver at high concentration. To test the accuracy of the mirrors’ optical slopes, we employ a technique called deflectometry. Deflectometry measures mirror slope directly. A projector displays an image onto a screen or wall, and a mirror is positioned to reflect the image to a camera. The camera sees the mirror’s reflection of the screen and sends imaging information to software which analyzes the reflected images from the mirror to determine the local slopes and curvature of the mirror. For this, projectors that can provide a crisp and clear image are imperative. Choosing the right projector(s) can be a long and tedious process; this paper will cover the process we used to select projectors for the SOFAST systems in the Sandia Concentrating Solar Optics Laboratory (CSOL).

14 SOLAR ENERGY↗

Review of High‐Speed Digital Image Correlation: Advancements and Good Practices

This paper reviews the current state of the art in high‐speed (HS) and ultrahigh‐speed (UHS) digital image correlation (DIC) techniques, emphasizing their critical role in experimental research across various scientific domains. HS and UHS DIC have evolved significantly, driven by advancements in camera systems, image processing algorithms and experimental methodologies. These developments have opened new avenues for capturing and analysing dynamic events with unprecedented temporal and spatial detail, but not without introducing challenges such as optical distortions, motion blur and lighting issues that can affect measurement quality. This review advocates for standardized reporting practices in HS/UHS DIC methodologies to improve reproducibility and reliability across studies, drawing on guidelines from the International Digital Image Correlation Society (iDICs). Through a comprehensive analysis of over 150 articles, this review identifies key advancements in imaging technology and their application in six research domains: material characterization, test development, fracture mechanics, model validation, ballistic and explosive phenomena assessment and measurement uncertainties. Distinctions between two‐dimensional (2D) and stereo‐DIC applications are explored, offering insights into their practical implementation and trade‐offs. Good practices for HS/UHS DIC applications are proposed along with suggestions for future directions for this evolving field, highlighting the indispensable role of technological innovation in expanding the capabilities of optical metrology.

experimental mechanics↗

Element differentiation with a Hartmann- based X-ray phase imaging system

Significant efforts are currently ongoing in X-ray imaging to provide multimodal imaging systems, targeting better sensitivity and specificity for both biomedical or non-destructive testing applications. Knowing the elemental composition of specific structures, such as breast microcalcifications in mammography, would help to differentiate malign and benign tumours. Standard X-ray Phase Contrast Imaging techniques provide only qualitative information on elements with similar absorption properties. However, their chemical composition can be determined from the measurement of the phase as it is directly related to the optical index of elemental materials. We will show new experimental results obtained with an X-ray phase imaging system based on a Hartmann mask. Early data treatment succeeded in retrieving both the real and imaginary parts of the refractive index. The system demonstrates the capability to discriminate materials based on elemental composition.

36 MATERIALS SCIENCE↗

Sparse Matrix-Based HPC Tomography

Tomographic imaging has benefited from advances in X-ray sources, detectors and optics to enable novel observations in science, engineering and medicine. These advances have come with a dramatic increase of input data in the form of faster frame rates, larger fields of view or higher resolution, so high performance solutions are currently widely used for analysis. Tomographic instruments can vary significantly from one to another, including the hardware employed for reconstruction: from single CPU workstations to large scale hybrid CPU/GPU supercomputers. Furthermore, flexibility on the software interfaces and reconstruction engines are also highly valued to allow for easy development and prototyping. This paper presents a novel software framework for tomographic analysis that tackles all aforementioned requirements. The proposed solution capitalizes on the increased performance of sparse matrix-vector multiplication and exploits multi-CPU and GPU reconstruction over MPI. Furthermore, the solution is implemented in Python and relies on CuPy for fast GPU operators and CUDA kernel integration, and on SciPy for CPU sparse matrix computation. As opposed to previous tomography solutions that are tailor-made for specific use cases or hardware, the proposed software is designed to provide flexible, portable and high-performance operators that can be used for continuous integration at different production environments, but also for prototyping new experimental settings or for algorithmic development. The experimental results demonstrate how our implementation can even outperform state-of-the-art software packages used at advanced X-ray sources worldwide.

97 MATHEMATICS AND COMPUTING↗

In-Situ X-Ray Imaging High Strain Rate Compression of Laminate Al-Graphene Composite and Mechanical Property Characterization

Owing to the opaque nature of the laminated structures, traditional high-speed optical camera cannot be used to detect the dynamic process of sub-surface deformation. In this article, we report a study of using high speed X-ray imaging to study the high strain rate deformation in laminated Al structures. We used a Kolsky bar apparatus to apply dynamic compression and a high-speed synchrotron X-ray phase contrast imaging (PCI) setup to conduct the in situ X-ray imaging study. The in situ X-ray imaging captures the shock wave propagation in the laminated structures. After shock compression, we characterized the microstructures by using transmission electron microscopy (TEM), which demonstrates an increase of dislocation density. In conclusion, the micro-pillar compression tests show that the yield strength at 0.2% offset of laminated Al-graphene composite has a significant increase of 67%, from 30 to 50 MPa, compared to laminate Al after shock loading.

36 MATERIALS SCIENCE↗

Assessing an aqueous flow cell designed for in situ crystal growth under X-ray nanotomography and effects of radiolysis products

Nucleation and growth of minerals has broad implications in the geological, environmental and materials sciences. Recent developments in fast X-ray nanotomography have enabled imaging of crystal growth in solutions in situ with a resolution of tens of nanometres, far surpassing optical microscopy. Here, a low-cost, custom-designed aqueous flow cell dedicated to the study of heterogeneous nucleation and growth of minerals in aqueous environments is shown. To gauge the effects of radiation damage from the imaging process on growth reactions, radiation-induced morphological changes of barite crystals (hundreds of nanometres to ∼1 µm) that were pre-deposited on the wall of the flow cell were investigated. Under flowing solution, minor to major crystal dissolution was observed when the tomography scan frequency was increased from every 30 min to every 5 min (with a 1 min scan duration). The production of reactive radicals from X-ray induced water radiolysis and decrease of pH close to the surface of barite are likely responsible for the observed dissolution. The flow cell shown here can possibly be adopted to study a wide range of other chemical reactions in solutions beyond crystal nucleation and growth where the combination of fast flow and fast scan can be used to mitigate the radiation effects.

36 MATERIALS SCIENCE↗

Direct detection system for full-field nanoscale X-ray diffraction-contrast imaging

Recent developments in X-ray science provide methods to probe deeply embedded mesoscale grain structures and spatially resolve them using dark field X-ray microscopy (DFXM). Extending this technique to investigate weak diffraction signals such as magnetic systems, quantum materials and thin films prove challenging due to available detection methods and incident X-ray flux at the sample. We present a direct detection method developed in conjunction with KAImaging which focuses on DFXM studies in the hard X-ray range of 10s of keV and above capable of approaching nanoscale resolution. Additionally, we compare this direct detection scheme with routinely used scintillator-based optical detection and achieve an order of magnitude improvement in exposure times allowing for imaging of weakly diffracting ordered systems.

47 OTHER INSTRUMENTATION↗

H i imaging of dwarf star-forming galaxies: masses, morphologies, and gas deficiencies

ABSTRACT The Giant Meter-wave Radio Telescope observations of the H i 21 cm-line emission from 13 nearby dwarf star-forming galaxies are presented. These galaxies are selected from the catalogues of Wolf−Rayet galaxies having very young (≤10 Myr) star formation. The ranges of star formation rates and stellar masses of the sample galaxies are 0.03–1.7 M⊙ yr−1 and 0.04–22.3 × 108 M⊙, respectively. The H i line emission is detected from 12 galaxies with peak column density >1 × 1021 cm−2. The 3σ H i column density sensitivities per channel width of 7 km s−1 for low (60 arcsec × 60 arcsec) resolution images are in the range 0.8–1.9 × 1019 cm−2. The H i channel images, moment images, global profiles, and mass surface density profiles are presented here. The average value of the peak H i mass surface density is estimated to be ∼2.5 M⊙ pc−2, which is significantly less compared to that in massive spiral galaxies. The scaling relations of $(M_{stars} + M_{\rm H\, I} + M_{\rm He})$versus Mdyn, gas fraction versus MB, $M_{\rm H\, I}$versus Mstars, H i-to-stellar mass ratio versus Mstars, and $M_{\rm H\, I}$versus $D_{\rm H\, I}$for the sample galaxies are estimated. These scaling relations can be used to constraint the key parameters in the galaxy evolution models. These galaxies are residing in group environment with galaxy density up to eight galaxy Mpc−3. An H i mass deficiency (with DEFH i > 0.3) is noticed in majority of galaxies for their optical diameters as compared to galaxies in field environments. Clear signatures of tidal interactions in these galaxies could be inferred using the H i images. Isolated H i clouds without known optical counterparts are seen in the vicinity of several galaxies. H i emission envelope is found to be having an offset from the optical envelope in several galaxies. Consistent with the previous studies on galaxy evolution in group environments, tidal interactions seem to play an important role in triggering recent star formation.

Jaiswal, S.↗

Development of limited-view tomography for measurement of Spray G plume direction and liquid volume fraction

Abstract The method for direct injection of fuel in the cylinder of an IC engines is important to high-efficiency and low-emission performance. Optical spray diagnostics plays an important role in understanding plume movement and interaction for multi-hole injectors, and providing baseline understanding used for computational optimization of fuel delivery. Traditional planar or line-of-sight diagnostics fail to capture the liquid distribution because of optical thickness concerns. This work proposes a high-speed (67 kHz) extinction imaging technique at various injector rotations coupled to computed tomography (CT) for time-resolved reconstruction of liquid volume fraction in three dimensions. The number of views selected and processing were based on synthetic (modeled) liquid volume fraction data where extinction and CT adequately reconstructed each plume. The exercise showed that for an 8-hole, symmetric-design injector (ECN Spray G), only three different views are enough to reproduce the direction of each plume, and particularly the mean plume direction. Therefore, the number of views was minimized for experiments to save expense. Measurements applying this limited-view technique confirm plume–plume variations also detected with mechanical patternation, while providing better spatial and temporal resolution than achieved previously. Uncertainties due to the limited view within pressurized spray chambers, the droplet size, and optically thick regions are discussed. Graphic abstract

42 ENGINEERING↗

Advanced monolithic 2D multilayer Laue lens (MLL) optics for hard x-ray nanofocusing and nanotomography

We report on the development of a new generation of monolithic two-dimensional (2D) multilayer Laue lens (MLL) optics suitable for high-resolution hard x-ray nanoimaging. The 2D optics were assembled on microfabricated silicon templates with high orthogonality and lateral alignment precision, which were characterized using white-light interferometry and confirmed by x-ray measurements. The developed monolithic 2D MLL optics were successfully employed for hard x-ray nanofocusing and nanotomography experiments using the ptychography imaging modality, demonstrating sub-10 nm resolution in 2D and sample-limited ∼30 nm in three-dimensional while exhibiting excellent stability during extended measurements. The new 2D MLL templates with high alignment accuracy represent an important step forward in the development of 2D MLL optics toward direct nanoimaging experiments with sub-10 nm spatial resolution.

36 MATERIALS SCIENCE↗

Scalable Nanoimprint Manufacturing of Functional Multilayer Metasurface Devices

Optical metasurfaces, consisting of subwavelength-scale meta-atom arrays, hold great promise of overcoming the fundamental limitations of conventional optics. Due to their structural complexity, metasurfaces usually require high-resolution yet slow and expensive fabrication processes. Here, using a metasurface polarimetric imaging device as an example, the photonic structures and the Nanoimprint lithography (NIL) processes are designed, creating two separate NIL molds over a patterning area of > 20 mm2 with designed Moiré alignment markers by electron-beam writing, and further subsequently integrate silicon and aluminum metasurface structures on a chip. Uniquely, the silicon and aluminum metasurfaces are fabricated by using the nanolithography and 3D pattern-transfer capabilities of NIL, respectively, achieving nanometer-scale linewidth uniformity, sub-200 nm translational overlay accuracy, and <0.017 rotational alignment error while significantly reducing fabrication complexity and surface roughness. Here, the micro-sized multilayer metasurfaces have high circular polarization extinction ratios as large as ≈20 and ≈80 in blue and red wavelengths. Further, the metasurface chip-integrated CMOS imager demonstrates high accuracy in broad-band, full Stokes parameter analysis in the visible wavelength ranges and single-shot polarimetric imaging. This novel, NIL-based, multilayered nanomanufacturing approach is applicable to the scalable production of large-area functional structures for ultra-compact optic, electronic, and quantum devices.

36 MATERIALS SCIENCE↗

Lateral and vertical growth of Mg-doped GaN on trench-patterned GaN films

Growth of Mg-doped GaN on trench-patterned GaN films consists of competing lateral and vertical growth fronts that result in regions with different electronic properties. Under typical growth conditions, lateral growth from the trench sidewall occurs at a faster rate than vertical growth from the trench base. When the trench width is sufficiently narrow, the growth fronts from opposite sidewalls coalesce and lead to eventual planarization of the top surface. Secondary electron imaging and cathodoluminescence mapping are used to correlate the morphology and the optical properties of regions resulting from lateral and vertical growth. For our growth conditions, the lateral-to-vertical growth rate ratio is found to be about 2.

Su, Po-Yi (ORCID:000000018339783X)↗

Two-photon polymerization printed lattices as support structures in multi-shell ICF targets: Platform development and initial assessment

Recent interest in fielding direct drive multi-shell targets on the NIF [K. Molvig et al., Phys. Rev. Lett. 116, 255003 (2016) and S. X. Hu et al., Phys. Rev. E 100, 063204 (2019)] has highlighted the need for a low density structure to support the inner shell(s) and to avoid energy loss in the acceleration and collision process. We have developed a two-shell platform to evaluate the use of low density two-photon polymerization (2PP) printed lattices as a support structure between the shells. Here, 2PP structures are an attractive option because they can be produced at densities as low as 5 mg/cc, which is ideal for multi-shell targets, and their 3D structure can be tailored to the user's needs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MHD mode tracking using high-speed cameras and deep learning

Abstract We present a new algorithm to track the amplitude and phase of rotating magnetohydrodynamic (MHD) modes in tokamak plasmas using high speed imaging cameras and deep learning. This algorithm uses a convolutional neural network (CNN) to predict the amplitudes of the n = 1 sine and cosine mode components using solely optical measurements from one or more cameras. The model was trained and tested on an experimental dataset consisting of camera frame images and magnetic-based mode measurements from the High Beta Tokamak - Extended Pulse (HBT-EP) device, and it outperformed other, more conventional, algorithms using identical image inputs. The effect of different input data streams on the accuracy of the model’s predictions is also explored, including using a temporal frame stack or images from two cameras viewing different toroidal regions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

FORECASTOR – II. Simulating galaxy surveys with the Cosmological Advanced Survey Telescope for Optical and UV Research

The Cosmological Advanced Survey Telescope for Optical and UV Research (CASTOR) is a planned flagship space telescope, covering the blue-optical and UV part of the spectrum. Here, we introduce the CASTOR image simulator, a python GalSim package-based script capable of generating mock CASTOR images from an input catalogue. We generate example images from the CASTOR Wide, Deep, and Ultra-Deep surveys using simulated lightcones from the Santa Cruz semi-analytic model. We make predictions for the performance of these surveys by comparing galaxies that are extracted from each image using Source Extractor to the input catalogue. We find that the Wide, Deep, and Ultra-Deep surveys will be 75 per cent complete for point sources down to $\sim 27$, 29, and 30 mag, respectively, in the UV, u, and g filters, with the UV-split and u-split filters reaching a shallower depth. With a large area of $\sim 2200$ deg$^2$, the Wide survey will detect hundreds of millions of galaxies out to $z\sim 4$, mostly with $M_\ast \gtrsim 10^{9}\,{\rm M}_{\odot }$. The Ultra-Deep survey will probe to $z\sim 5$, detecting galaxies with $M_\ast \gtrsim 10^{7}{\rm M}_{\odot }$. These galaxy samples will enable precision measurements of the distribution of star formation in the cosmic web, connecting the growth of stellar mass to the assembly of dark matter haloes over two thirds of the history of the Universe, and other core goals of CASTOR’s legacy surveys. These image simulations and the tools developed to generate them will be a vital planning tool to estimate CASTOR’s performance and iterate the telescope and survey designs prior to launch.

79 ASTRONOMY AND ASTROPHYSICS↗

Tomographic FLEET with a wedge array for multi-point three-component velocimetry

Femtosecond laser electronic excitation tagging (FLEET) velocimetry is an important diagnostic technique for seedless velocimetry measurements particularly in supersonic and hypersonic flows. Typical FLEET measurements feature a single laser line and camera system to achieve one-component velocimetry along a line, although some multiple-spot and multiple-component configurations have been demonstrated. In this work, tomographic imaging is used to track the three-dimensional location of many FLEET spots. A quadscope is used to combine four unique views onto a single high-speed image intensifier and camera. Tomographic reconstructions of the FLEET emission are analyzed for three-component velocimetry from multiple FLEET spots. Glass wedges are used to create many (nine) closely spaced FLEET spots with less than 10% transmission losses. These developments lead to a significant improvement in the dimensionality and spatial coverage of a FLEET instrument with some increases in experimental complexity and data processing. Multiple-point three-component FLEET velocimetry is demonstrated in an underexpanded jet.