Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “insertion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Exact correlators on the Wilson loop in $$ \mathcal{N}=4 $$ SYM: localization, defect CFT, and integrability

We compute a set of correlation functions of operator insertions on the 1/8 BPS Wilson loop in N=4 SYM by employing supersymmetric localization, OPE and the Gram-Schmidt orthogonalization. These correlators exhibit a simple determinant structure, are position-independent and form a topological subsector, but depend nontrivially on the ’t Hooft coupling and the rank of the gauge group. When applied to the 1/2 BPS circular (or straight) Wilson loop, our results provide an infinite family of exact defect CFT data, including the structure constants of protected defect primaries of arbitrary length inserted on the loop. At strong coupling, we show precise agreement with a direct calculation using perturbation theory around the AdS 2 string worldsheet. We also explain the connection of our results to the “generalized Bremsstrahlung functions” previously computed from integrability techniques, reproducing the known results in the planar limit as well as obtaining their finite N generalization. Furthermore, we show that the correlators at large N can be recast as simple integrals of products of polynomials (known as Q-functions) that appear in the Quantum Spectral Curve approach. This suggests an interesting interplay between localization, defect CFT and integrability.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Twistorial monopoles & chiral algebras

We initiate the study of how the insertion of magnetically charged states in 4d self-dual gauge theories impacts the 2d chiral algebras supported on the celestial sphere at asymptotic null infinity, from the point of view of the 4d/2d twistorial correspondence introduced by Costello and the second author. By reducing the 6d twistorial theory to a 3d holomorphic-topological theory with suitable boundary conditions, we can motivate certain non-perturbative enhancements of the celestial chiral algebra corresponding to extensions by modules arising from 3d boundary monopole operators. We also identify the insertion of 4d (non-abelian) monopoles with families of spectral flow automorphisms of the celestial chiral algebra.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Null states and time evolution in a toy model of black hole dynamics

Abstract Spacetime wormholes can provide non-perturbative contributions to the gravitational path integral that make the actual number of statese S in a gravitational system much smaller than the number of states$$ {e}^{S_{\textrm{p}}} $$ e S p predicted by perturbative semiclassical effective field theory. The effects on the physics of the system are naturally profound in contexts in which the perturbative description actively involvesN=O(e S ) of the possible$$ {e}^{S_{\textrm{p}}} $$ e S p perturbative states; e.g., in late stages of black hole evaporation. Such contexts are typically associated with the existence of non-trivial quantum extremal surfaces. However, by forcing a simple topological gravity model to evolve in time, we find that such effects can also have large impact forN≪e S (in which case no quantum extremal surfaces can arise). In particular, even for smallN, the insertion of generic operators into the path integral can cause the non-perturbative time evolution to differ dramatically from perturbative expectations. On the other hand, this discrepancy is small for the special case where the inserted operators are non-trivial only in a subspace of dimensionD≪e S . We thus study this latter case in detail. We also discuss potential implications for more realistic gravitational systems.

Physics↗

2D Kac-Moody symmetry of 4D Yang-Mills theory

Scattering amplitudes of any four-dimensional theory with nonabelian gauge group G may be recast as two-dimensional correlation functions on the asymptotic twosphere at null in nity. The soft gluon theorem is shown, for massless theories at the semiclassical level, to be the Ward identity of a holomorphic two-dimensional G-Kac-Moody symmetry acting on these correlation functions. Holomorphic Kac-Moody current insertions are positive helicity soft gluon insertions. Furthermore, the Kac-Moody transformations are a CPT invariant subgroup of gauge transformations which act nontrivially at null in nity and comprise the four-dimensional asymptotic symmetry group.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Superluminal chaos after a quantum quench

Thermal states holographically dual to black holes in Einstein gravity display maximal Lyapunov growth as well as “butterfly effect cones”. We study these effects in highly non-equilibrium states, obtained from an initial thermal state by the sudden injection of energy. We do this by computing out-of-time-order correlators (OTOCs) in BTZ-Vaidya spacetimes, which describe transitions between black holes at different temperatures. If both pairs of boundary operators appearing in the OTOC are inserted before the energy injection, we recover standard results, with butterfly effect cones displaying a light-cone structure. But when one pair of operators is inserted before and the other pair after the energy injection, the Lyapunov growth saturates the chaos bounds set by the local temperatures and the butterfly effect cones can “open up”, becoming superluminal, albeit in a way that does not violate causality. In the limiting case, in which the initial state is the vacuum, Lyapunov growth only starts after the energy injection. Our computations of the OTOCs are phrased in terms of gravitationally interacting particles, where fields are treated in a geodesic approximation and the eikonal phase shift is expressed in terms of stress tensors and shock waves associated to geodesics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Low pH-Induced Pore Formation by the T Domain of Botulinum Toxin Type A is Dependent upon NaCl Concentration

Botulinum neurotoxins (BoNTs) undergo low pH-triggered membrane insertion, resulting in the translocation of their light (catalytic) chains into the cytoplasm. The T (translocation) domain of the BoNT heavy chain is believed to carry out translocation. Here, the behavior of isolated T domain from BoNT type A has been characterized, both in solution and when associated with model membranes. When BoNT T domain prepared in the detergent dodecylmaltoside was diluted into aqueous solution, it exhibited a low pH-dependent conformational change below pH 6. At low pH the T domain associated with, and formed pores within, model membrane vesicles composed of 30 mol% dioleoylphosphatidylglycerol/70 mol% dioleoylphosphatidylcholine. Although T domain interacted with vesicles at low (50 mM) and high (400 mM) NaCl concentrations, the interaction required much less lipid at low salt. However, even at high lipid concentrations pore formation was much more pronounced at low NaCl concentrations than at high NaCl concentration. Increasing salt concentration after insertion in the presence of 50 mM NaCl did not decrease pore formation. A similar effect of NaCl concentration upon pore formation was observed in vesicles composed solely of dioleoylphosphatidylcholine, showing that the effect of NaCl did not solely involve modulation of electrostatic interactions between protein and anionic lipids. These results indicate that some feature of membrane-bound T domain tertiary structure critical for pore formation is highly dependent upon salt concentration.

59 BASIC BIOLOGICAL SCIENCES↗

Decreasing transmembrane segment length greatly decreases perfringolysin O pore size

Perfringolysin O (PFO) is a transmembrane (TM) β-barrel protein that inserts into mammalian cell membranes. Once inserted into membranes, PFO assembles into pore-forming oligomers containing 30–50 PFO monomers. These form a pore of up to 300 Å, far exceeding the size of most other proteinaceous pores. In this study, we found that altering PFO TM segment length can alter the size of PFO pores. A PFO mutant with lengthened TM segments oligomerized to a similar extent as wild-type PFO, and exhibited pore-forming activity and a pore size very similar to wild-type PFO as measured by electron microscopy and a leakage assay. In contrast, PFO with shortened TM segments exhibited a large reduction in pore-forming activity and pore size. This suggests that the interaction between TM segments can greatly affect the size of pores formed by TM β-barrel proteins. PFO may be a promising candidate for engineering pore size for various applications.

59 BASIC BIOLOGICAL SCIENCES↗

Comparison of a New Polytetrafluoroethylene-Covered Metallic Stent to a Noncovered Stent in Canine Ureters

The aim of this study was to determine the feasibility of using a newly designed polytetrafluoroethylene (PTFE)-covered metallic stent in the ureter by comparing its effectiveness with that of the noncovered stent in a canine model. We placed 14 stents in the ureters of seven mongrel dogs that weighed 30-40 kg each. The covered and noncovered stents were deployed in the right and left ureters, respectively, of six dogs. In the seventh dog, a covered stent and a double-J catheter were inserted in the right ureter, and a covered stent only was inserted in the left ureter. The first six dogs were sacrificed at 5, 10, and 15 weeks after deployment of the stents (two for each follow-up period), and the seventh dog was sacrificed at 30 weeks. There was no migration or poor expansion of any of the stents observed on plain radiography. On intravenous pyelogram and retrograde pyelogram, all of the covered stents at each follow-up period had patent lumens at the stented segments without hydronephrosis, and the passage of contrast material through it was well preserved. The noncovered stents in the dogs sacrificed at 5 and 10 weeks and one of the two dogs sacrificed at 15 weeks showed near-complete occlusion of the stent lumen due to ingrowth of the soft tissue, and severe hydronephrosis was also noted. The noncovered stent in the other dog sacrificed at 15 weeks showed the passage of contrast material without hydronephrosis, but the lumen of the stent was still nearly occluded by the soft tissue. There was no evidence of hydronephrosis or passage disturbance of the contrast material in both ureters of the dog sacrificed at 30 weeks. We conclude that the newly designed PTFE-covered stent effectively prevented the luminal occlusion caused by urothelial hyperplasia compared to the near-total occlusion of the noncovered stents, and no migration of the covered stents was noted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Direct Percutaneous Jejunostomy-An Underutilized Interventional Technique?

Our aim in this study was to report our single-center experience with direct percutaneous jejunostomy over a 4-year period with regard to technical success rate, immediate and late complications, and patient tolerance of the procedure. Institutional records of 22 consecutive patients who underwent radiological insertion of a percutaneous jejunostomy for a variety of indications were reviewed. The proximal jejunum was punctured under either fluoroscopic or ultrasonic guidance, and following placement of retention sutures, a 10- to 12-Fr catheter inserted. There was a 100% technical success rate in placement involving a total of seven operators. The indications for placement were prior gastric resection, newly diagnosed resectable esophageal or gastric carcinoma, unresectable gastric carcinoma with outlet obstruction, and palliative drainage of bowel obstruction. Mean duration of follow-up was 100 days, and catheter placement 57.7 days. There were six minor early complications, consisting of loss of two retention anchors requiring repuncture, three cases of localized excessive postprocedural pain, and one failed relief of symptoms of small bowel obstruction. Four tubes developed late complications (two blocked, one catheter cracked, and one inadvertently pulled out). Three of the four were successfully replaced through the existing tracts. One patient subsequently developed a minor skin infection, while another developed late pericatheter leakage from ascites. We conclude that direct percutaneous jejunostomy is a valuable treatment modality applicable to a number of clinical scenarios, with a high technical success rate and low serious complication rate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Modified Metallic Coil Embolization Technique for Pulmonary Arteriovenous Malformations Using Coil Anchors and Occlusion Balloon Catheters

Purpose. To evaluate the feasibility and efficacy of a modified metallic coil embolization technique for pulmonary arteriovenous malformations (PAVMs) using coil anchors and occlusion balloon catheters. Methods. Five consecutive female patients with 6 PAVMs were included in the present study. One of the 6 PAVMs was of the complex type with four feeding arteries. An occlusion balloon catheter was inserted into the feeding artery as close to the venous sac as possible. The coil anchor, which was a simple W-shaped bent stainless steel wire with two markers at each end, was deployed prior to embolization to prevent the systemic migration of embolic materials. Then, metallic coils were deployed around the coil anchors under inflow stoppage using the inflated occlusion balloon catheter. In the complex-type PAVM, the main feeder was occluded by this technique and the other three small feeders were embolized with metallic coils only. Results. In all 5 cases, occlusion balloon catheters could be inserted into the feeding arteries just proximal to the venous sacs, coil anchors were easily deployed, and complete occlusion was achieved without any migration of metallic coils or paradoxical embolism during the procedure. Conclusions. The modified metallic coil embolization technique with coil anchors and occlusion balloon catheters was feasible and considered to be useful in preventing procedure-related complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Chronic Pain Syndrome Caused by a Bird's Nest Filter: First Case Report

AimTo report the first case of a Bird's Nest IVC filter causing a chronic pain syndrome lasting 13 years through IVC wall penetration and subsequent break off of one of the filter struts.Materials and ResultsA 43-year-old female presented with a 13-year history of abdominal pain following uneventful insertion of a Bird's Nest vena cava filter through a right internal jugular percutanous approach. A year following the procedure, CT scan revealed one arm of the filter to be outside IVC borders. Nine years from the date of insertion the nature of the pain changed acutely following a five feet jump to more localized RUQ pain worse with twisting movements. A CT scan showed the strut to have pierced the IVC wall and penetrated the Unicate process of pancreas. Plain x-rays taken at different times in February 2006 showed one of the struts to be free floating in the peritoneal cavity. The floating strut was removed surgically from the wall of the Ileum. Postoperative recovery was uneventful and the patient was discharged pain free three days later.ConclusionChronic pain is an added complication of BNF devices. Although rare, it further emphasizes the need for long-term follow up of patients with IVC filters.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Malignant Gastroduodenal Obstruction: Treatment with Self-Expanding Uncovered Wallstent

Purpose: To retrospectively evaluate the clinical effectiveness of a self-expanding uncovered Wallstent in patients with malignant gastroduodenal obstruction. Materials and Methods: Under combined endoscopic and fluoroscopic guidance, 29 patients with a malignant gastroduodenal stenosis were treated with a self-expanding uncovered metallic Wallstent. A dysphagia score was assessed before and after the intervention to measure the success of this palliative therapy. The dysphagia score ranged between grade 0 to grade 4: grade 0 = able to tolerate solid food, grade 1 = able to tolerate soft food, grade 2 = able to tolerate thick liquids, grade 3 = able to tolerate water or clear fluids, and grade 4 = unable to tolerate anything perorally. Stent patency and patients survival rates were calculated. Results: The insertion of the gastroduodenal stent was technically successful in 28 patients (96.5%). After stenting, 25 patients (86.2%) showed clinical improvement by at least one score point. During follow-up, 22 (78.5%) of 28 patients showed no stent occlusion until death and did not have to undergo any further intervention. In six patients (20.6%), all of whom were treated with secondary stent insertions, occlusion with tumor ingrowth and/or overgrowth was observed after the intervention. The median period of primary stent patency in our study was 240 days. Conclusion: Placement of an uncovered Wallstent is clinically effective in patients with malignant gastroduodenal obstruction. Stent placement is associated with high technical success, good palliation effect, and high durability of stent function.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Removal of T-Fasteners 2 Days After Gastrostomy is Feasible

T-fastener gastropexy is widely performed as part of gastrostomy insertion. The current literature recommends removal of T-fasteners at 2 weeks. We present a series of patients in whom T-fasteners were removed at 2 days with no major complications. We removed T-fasteners in 109 patients (male-to-female ratio 59:50, age range 18 to 88 years, mean age 62 years) at 2 days after gastrostomy insertion. Indications for gastrostomy included amytrophic lateral sclerosis, cerebrovascular accidents, head and neck carcinoma, multiple sclerosis, and others, including brain tumours and chronic inflammatory demyelinating polyneuropathy. No peritubal leaks or other major complications were seen in the study population. In the study group, 15 minor complications were recorded (14%), including localised infection and pain, both of which resolved on removal of T-fasteners. We conclude that it is feasible and safe to remove T-fasteners at 2 days.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Total Percutaneous Aortic Repair: Midterm Outcomes

The purpose of this study was to examine the immediate and midterm outcomes of percutaneous endovascular repair of thoracic and abdominal aortic pathology. Between December 2003 and June 2005, 21 patients (mean age: 60.4 {+-} 17.1 years; 15 males, 6 females) underwent endovascular stent-graft insertion for thoracic (n = 13) or abdominal aortic (n = 8) pathology. Preprocedural computed tomographic angiography (CTA) was performed to assess the suitability of aorto-iliac and common femoral artery (CFA) anatomy, including the degree of CFA calcification, for total percutaneous aortic stent-graft repair. Percutaneous access was used for the introduction of 18- to 26-Fr delivery devices. A 'preclose' closure technique using two Perclose suture devices (Perclose A-T; Abbott Vascular) was used in all cases. Data were prospectively collected. Each CFA puncture site was assessed via clinical examination and CTA at 1, 6, and 12 months, followed by annual review thereafter. Minimum follow-up was 36 months. Outcome measures evaluated were rates of technical success, conversion to open surgical repair, complications, and late incidence of arterial stenosis at the site of Perclose suture deployment. A total of 58 Perclose devices were used to close 29 femoral arteriotomies. Outer diameters of stent-graft delivery devices used were 18 Fr (n = 5), 20 Fr (n = 3), 22 Fr (n = 4), 24 Fr (n = 15), and 26 Fr (n = 2). Percutaneous closure was successful in 96.6% (28/29) of arteriotomies. Conversion to surgical repair was required at one access site (3.4%). Mean follow-up was 50 {+-} 8 months. No late complications were observed. By CT criteria, no patient developed a >50% reduction in CFA caliber at the site of Perclose deployment during the study period. In conclusion, percutaneous aortic stent-graft insertion can be safely performed, with a low risk of both immediate and midterm access-related complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Placement of Hemodialysis Catheters Through Stenotic or Occluded Central Thoracic Veins

A method for hemodialysis catheter placement in patients with central thoracic venous stenosis or occlusion is described and initial results are analyzed. Twelve patients, with a mean age of 63.2 years (42-80 years), with central venous stenosis or occlusion, and who required a hemodialysis catheter were reviewed. All lesions were confirmed by helical CT or phlebography. Five patients had stenosis while seven patients were diagnosed with an occlusion of thoracic central veins. All patients were asymptomatic, without sign of superior vena cava syndrome. After percutaneous transstenotic catheterization or guidewire-based recannalization in occlusions, a balloon dilatation was performed and a stent was placed, when necessary, prior to catheter placement. Technical success was 92%. Three patients had angioplasty alone and nine patients had angioplasty with stent placement. Dialysis catheters were successfully inserted through all recannalized accesses. No immediate complication occurred, nor did any patient develop superior vena cava syndrome after the procedure. The mean follow-up was 21.8 months (range, 8-48 months). Three patients developed a catheter dysfunction with fibrin sheath formation (at 7, 11, and 12 months after catheter placement, respectively). Two were successfully managed by percutaneous endovascular approach and one catheter was removed. In conclusion, for patients with central venous stenosis or occlusion and those who need a hemodialysis catheter, catheter insertion can be reliably achieved immediately after endovascular recannalization with acceptable technical and long-term success rates. This technique should be considered as an alternative procedure for placing a new hemodialysis catheter through a patent vein.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Heparin-Coated and Conventional Split-Tip Hemodialysis Catheters

Catheter coatings have the potential to decrease infection and thrombosis in patients with chronic dialysis catheters. We report our midterm experience with a heparin-coated dialysis catheter. This retrospective, case-control study was approved by our Institutional Review Board. A total of 88 tunneled dialysis catheters were inserted over a 13-month period via the internal jugular vein. Thirty-eight uncoated split-tip catheters and 50 heparin-coated catheters were inserted. Primary catheter patency was compared between the two groups using the log rank test, with infection and/or thrombosis considered as catheter failures. Dialysis parameters during the first and last dialysis sessions, including pump speed, actual blood flow, and arterial port pressures, were compared using unpaired t-tests. Primary patency of the uncoated catheters was 86.0 {+-} 6.5% at 30 days and 76.1 {+-} 8.9% at 90 days. Primary patency of heparin-coated catheters was 92.0 {+-} 6.2% at 30 days and 81.6 {+-} 8.0% at 90 days (p = 0.87, log rank test). Infection requiring catheter removal occurred in four patients with uncoated catheters and two patients with heparin-coated catheters (p = 0.23). Catheter thrombosis requiring catheter replacement or thrombolysis occurred in one patient with an uncoated catheter and two patients with heparin-coated catheters (p = 0.9). No differences in catheter function during hemodialysis were seen between the two groups. In conclusion, the heparin-coated catheter did not show a significantly longer patency compared to the uncoated catheter. The flow characteristics of this device were comparable to those of the conventional uncoated catheter. A demonstrable benefit of the heparin-coated catheter in randomized trials is needed before a recommendation for routine implementation can be made.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Management of Delayed Complete Graft Thrombosis After Endovascular Aneurysm Repair

Graft thrombosis rates after endovascular aneurysm repair (EVAR) of abdominal aortic aneurysms vary widely in published series. When thrombosis does occur, it usually involves a single limb and occurs within 3 months of stent-graft insertion. If the entire endoprosthesis is thrombosed, treatment may be challenging because femoro-femoral crossover graft insertion is not an option and a greater volume of thrombus is present, thus making thrombolysis more difficult. We present two cases of delayed thrombosis after EVAR involving the entire stent-graft. These were successfully treated by a combined surgical and endovascular technique, and patency has been maintained in both cases to date.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Minimally Invasive Catheter Procedures to Assist Complicated Pacemaker Lead Extraction and Implantation in the Operating Room

We report on percutaneous catheter procedures in the operating room (OR) to assist complicated manual extraction or insertion of pacemaker (PM) and implantable cardioverter defibrillator leads. We retrospectively reviewed complicated PM revisions and implantations performed between 2004 and 2009 that required percutaneous catheter procedures performed in the OR. The type of interventional procedure, catheter and retrieval system used, venous access, success rates, and procedural complications were analyzed. In 41 (12 female and 29 male [mean age 62 {+-} 17 years]) of 3021 (1.4%) patients, standard manual retrieval of old leads or insertion of new leads was not achievable and thus required percutaneous catheter intervention for retrieval of misplaced leads and/or recanalisation of occluded central veins. Thirteen of 18 (72.2%) catheter-guided retrieval procedures for misplaced (right atrium [RA] or ventricle [RV; n = 3], superior vena cava [n = 2], brachiocephalic vein [n = 5], and subclavian vein [n = 3]) lead fragments in 16 patients were successful. Percutaneous catheter retrieval failed in five patients because there were extremely fixed or adhered lead fragments. Percutaneous transluminal angiography (PTA) of central veins for occlusion or high-grade stenosis was performed in 25 patients. In 22 of 25 patients (88%), recanalization of central veins was successful, thus enabling subsequent lead replacement. Major periprocedural complications were not observed. In the case of complicated manual PM lead implantation or revision, percutaneous catheter-guided extraction of misplaced lead fragments or recanalisation of central veins can be performed safely in the OR, thus enabling subsequent implantation or revision of PM systems in the majority of patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗