Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image alignment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

EVIDENCE FOR TWO SEPARATE BUT INTERLACED COMPONENTS OF THE CHROMOSPHERIC MAGNETIC FIELD

Chromospheric fibrils are generally thought to trace out low-lying, mainly horizontal magnetic fields that fan out from flux concentrations in the photosphere. A high-resolution ({approx}0.''1 pixel{sup -1}) image, taken in the core of the Ca II 854.2 nm line and covering an unusually large area, shows the dark fibrils within an active region remnant as fine, looplike features that are aligned parallel to each other and have lengths comparable to a supergranular diameter. Comparison with simultaneous line-of-sight magnetograms confirms that the fibrils are centered above intranetwork areas (supergranular cell interiors), with one end rooted just inside the neighboring plage or strong unipolar network but the other endpoint less clearly defined. Focusing on a particular arcade-like structure lying entirely on one side of a filament channel (large-scale polarity inversion), we find that the total amount of positive-polarity flux underlying this 'fibril arcade' is {approx}50 times greater than the total amount of negative-polarity flux. Thus, if the fibrils represent closed loops, they must consist of very weak fields (in terms of total magnetic flux), which are interpenetrated by a more vertical field that contains most of the flux. This surprising result suggests that the fibrils in unipolar regions connect the network to the nearby intranetwork flux, while the bulk of the network flux links to remote regions of the opposite polarity, forming a second, higher canopy above the fibril canopy. The chromospheric field near the edge of the network thus has an interlaced structure resembling that in sunspot penumbrae.

79 ASTRONOMY AND ASTROPHYSICS↗

Evidence for Phanerozoic reactivation of the Najd Fault System in AVHRR, TM, and SPOT images of central Arabia

SPOT stereoscopic and TM multispectral images support evidence in AVHRR thermal-IR images of a major unmapped shear zone in Phanerozoic cover rocks southeast of the ancient Najd Fault System in the Arabian Shield. This shear zone and faults of the Najd share a common alignment, orientation, and sinistral sense of movement. These similarities suggest a 200-km extension of the Najd Fault System and reactivation since it formed in the late Precambrian. Topographic and lithologic features in the TM and SPOT data along one of three faults inferred from the AVHRR data indicate sinistral offsets up to 2.5 km, en echelon folds and secondary faults like those predicted by models of left-lateral strike-slip faulting. The age of the affected outcrops indicates reactivation of Najd faults in the Cretaceous, judging from TM and SPOT data or in the Tertiary, based on AVHRR data. The total length of the system visible at the surface measures 1300 km. If the Najd Fault System is extrapolated beneath sands of the Empty Quarter to faults of a similar trend in South Yemen, the shear zone would span the Arabian Plate. Furthermore, if extensions into the Arabian Sea bed and into Egypt proposed by others are considered, it would exceed 3000 km.

Andre, Constance G.↗

The on-orbit optical performance of STIS

The Space Telescope Imaging Spectrograph (STIS) is a versatile, general purpose instrument installed aboard the Hubble Space Telescope in February, 1997. During the following Servicing Mission Orbital Verification (SMOV) period, STIS has been made operational and aligned, and initial checkout and calibration completed. The overall optical performance goals have largely been achieved and a summary of these results is presented.

Bowers, Charles W.↗

NGST/XRCF Design and Build Wavescope System Pallet

Based on the successful Wavescope demonstration at MSFC at the end of March, the decision was made by the optical testing team to purchase an upgraded Wavescope from AOA. The MSFC version would include: a higher resolution camera (1000 x 1000 pixels); a higher density lenslet array (150 x 150); updated software; and longer cables (to accommodate the remote operation of the Wavescope optical head which was resident in the Beam Guide Tube). The AOA proposal for the new instrument was received in mid-April, and delivered to MSFC in mid-July. A considerable amount of effort was expended to provide the infrastructure needed for Wavescope operation, and to incorporate it into the overall test system. This was provided by the Wavescope System Pallet (WSP) built by UAH. The WSP is illustrated. Several instruments are incorporated on this pallet. These include the: Wavescope optical head; a PDI wavefront sensor; a point spread function sensor; a Leica light-based distance measuring sensor. In addition there is a single mode fiber point source (fed from a separate source pallet) which serves both as a reference for the Wavescope and as a source point for the test mirror. There is a dual function lens which both collimates the beam from the test image point, and images the test mirror onto the lenslet array. There is a high quality Collimator which can provide a flat input wavefront directly into the Wavescope. There are also various aids such as an alignment laser, an alignment telescope, alignment sticks and apertures. The WSP was delivered to MSFC on 7/28/99. An picture shows the WSP installed in the Guide Tube at the X-Ray Calibration Facility (XRCF).

Geary, Joe↗

Evidence for Two Separate but Interlaced Components of the Chromospheric Magnetic Field

Chromospheric fibrils are generally thought to trace out low-lying, mainly horizontal magnetic elds that fan out from flux concentrations in the photosphere. A high-resolution (approximately 0.1" per pixel) image, taken in the core of the Ca II 854.2 nm line and covering an unusually large area, shows the dark brils within an active region remnant as fine, looplike features that are aligned parallel to each other and have lengths comparable to a supergranular diameter. Comparison with simultaneous line-of-sight magnetograms confirms that the fibrils are centered above intranetwork areas (supergranular cell interiors), with one end rooted just inside the neighboring plage or strong unipolar network but the other endpoint less clearly defined. Focusing on a particular arcade-like structure lying entirely on one side of a lament channel (large-scale polarity inversion), we find that the total amount of positive-polarity flux underlying this "fibril arcade" is approximately 50 times greater than the total amount of negative-polarity flux. Thus, if the brils represent closed loops, they must consist of very weak fields (in terms of total magnetic flux), which are interpenetrated by a more vertical field that contains most of the flux. This surprising result suggests that the fibrils in unipolar regions connect the network to the nearby intranetwork flux, while the bulk of the network flux links to remote regions of the opposite polarity, forming a second, higher canopy above the fibril canopy. The chromospheric field near the edge of the network thus has an interlaced structure resembling that in sunspot penumbrae.

Reardom, K. P.↗

Video Guidance Sensor and Time-of-Flight Rangefinder

A proposed video guidance sensor (VGS) would be based mostly on the hardware and software of a prior Advanced VGS (AVGS), with some additions to enable it to function as a time-of-flight rangefinder (in contradistinction to a triangulation or image-processing rangefinder). It would typically be used at distances of the order of 2 or 3 kilometers, where a typical target would appear in a video image as a single blob, making it possible to extract the direction to the target (but not the orientation of the target or the distance to the target) from a video image of light reflected from the target. As described in several previous NASA Tech Briefs articles, an AVGS system is an optoelectronic system that provides guidance for automated docking of two vehicles. In the original application, the two vehicles are spacecraft, but the basic principles of design and operation of the system are applicable to aircraft, robots, objects maneuvered by cranes, or other objects that may be required to be aligned and brought together automatically or under remote control. In a prior AVGS system of the type upon which the now-proposed VGS is largely based, the tracked vehicle is equipped with one or more passive targets that reflect light from one or more continuous-wave laser diode(s) on the tracking vehicle, a video camera on the tracking vehicle acquires images of the targets in the reflected laser light, the video images are digitized, and the image data are processed to obtain the direction to the target. The design concept of the proposed VGS does not call for any memory or processor hardware beyond that already present in the prior AVGS, but does call for some additional hardware and some additional software. It also calls for assignment of some additional tasks to two subsystems that are parts of the prior VGS: a field-programmable gate array (FPGA) that generates timing and control signals, and a digital signal processor (DSP) that processes the digitized video images. The additional timing and control signals generated by the FPGA would cause the VGS to alternate between an imaging (direction-finding) mode and a time-of-flight (range-finding mode) and would govern operation in the range-finding mode.

Bryan, Thomas↗

SU-F-J-71: Improving CT Quality for Radiation Therapy Planning and Delivery Guidance Using a Non-Linear Contrast Enhancement Technique

Purpose: Advanced image post-processing techniques which enhance soft-tissue contrast in CT have not been widely employed for RT planning or delivery guidance. The purpose of this work is to assess the soft-tissue contrast enhancement from non-linear contrast enhancing filters and its impact in RT. The contrast enhancement reduces patient alignment uncertainties. Methods: Non-linear contrast enhancing methods, such as Best Contrast (Siemens), amplify small differences in X-ray attenuation between two adjacent structure without significantly increasing noise. Best Contrast (BC) separates a CT into two frequency bands. The low frequency band is modified by a non-linear scaling function before recombination with the high frequency band. CT data collected using a CT-on-rails (Definition AS Open, Siemens) during daily CT-guided RT for 6 prostate cancer patients and an image quality phantom (The Phantom Laboratory) were analyzed. Images acquired with a standard protocol (120 kVp, 0.6 pitch, 18 mGy CTDIvol) were processed before comparison to the unaltered images. Contrast and noise were measured in the the phantom. Inter-observer variation was assessed by placing prostate contours on the 12 CT study sets, 6 enhanced and 6 unaltered, in a blinded study involving 8 observers. Results: The phantom data demonstrate that BC increased the contrast between the 1.0% supra-slice element and the background substrate by 46.5 HU while noise increased by only 2.3 HU. Thus the contrast to noise ratio increased from 1.28 to 6.71. Furthermore, the variation in centroid position of the prostate contours was decreased from 1.3±0.4 mm to 0.8±0.3 mm. Thus the CTV-to-PTV margin was reduced by 1.1 mm. The uncertainty in delineation of the prostate/rectum edge decreased by 0.5 mm. Conclusion: As demonstrated in phantom and patient scans the BC filter accentuates soft-tissue contrast. This enhancement leads to reduced inter-observer variation, which should improve RT planning and delivery. Supported by Siemens.

60 APPLIED LIFE SCIENCES↗

THE DISCOVERY OF RADIO STARS WITHIN 10'' OF Sgr A* AT 7 mm

Very Large Array observations of the Galactic center at 7 mm have produced an image of the 30'' surrounding Sgr A* with a resolution of ∼82 × 42 milliarcseconds (mas). A comparison with IR images taken simultaneously with the Very Large Telescope identifies 41 radio sources with L-band (3.8 μm) stellar counterparts. The well-known young, massive stars in the central Sgr A* cluster (e.g., IRS 16C, IRS 16NE, IRS 16SE2, IRS 16NW, IRS 16SW, AF, AFNW, IRS 34W, and IRS 33E) are detected with peak flux densities between ∼0.2 and 1.3 mJy. The origin of the stellar radio emission in the central cluster is discussed in terms of ionized stellar winds with mass-loss rates in the range ∼0.8-5 × 10{sup –5} M {sub ☉} yr{sup –1}. Radio emission from eight massive stars is used as a tool for registration between the radio and infrared frames with mas precision within a few arcseconds of Sgr A* . This is similar to the established technique of aligning SiO masers and evolved stars except that radio stars lie within a few arcseconds of Sgr A*. Our data show a scatter of ∼6.5 mas in the positions of the eight radio sources that appear in both the L-band and 7 mm images. Last, we use the radio and IR data to argue that members of IRS 13N are young stellar objects rather than dust clumps, supporting the hypothesis that recent star formation has occurred near Sgr A*.

79 ASTRONOMY AND ASTROPHYSICS↗

Poster – 41: External marker block placement on the breast or chest wall for left-sided deep inspiration breath-hold radiotherapy

Purpose: We investigate DIBH breast radiotherapy using the Real-time Position Management (RPM) system with the marker-block placed on the target breast or chest wall. Methods: We measured surface dose for three different RPM marker-blocks using EBT3 Gafchromic film at 0° and 30° incidence. A registration study was performed to determine the breast surface position that best correlates with overall internal chest wall position. Surface and chest wall contours from MV images of the medial tangent field were extracted for 15 patients. Surface contours were divided into three potential marker-block positions on the breast: Superior, Middle, and Inferior. Translational registration was used to align the partial contours to the first-fraction contour. Each resultant transformation matrix was applied to the chest wall contour, and the minimum distance between the reference chest wall contour and the transformed chest wall contour was evaluated for each pixel. Results: The measured surface dose for the 2-dot, 6-dot, and 4-dot marker-blocks at 0° incidence were 74%, 71%, and 77% of dose to dmax respectively. At 30° beam incidence this increased to 76%, 72%, and 81%. The best external surface position was patient and fraction dependent, with no consistent best choice. Conclusions: The increase in surface dose directly under the RPM block is approximately equivalent to 3 mm of bolus. No marker-block position on the breast surface was found to be more representative of overall chest wall motion; therefore block positional stability and reproducibility can be used to determine optimal placement on the breast or chest wall.

60 APPLIED LIFE SCIENCES↗

Atom-by-atom imaging of moiré transformations in 2D transition metal dichalcogenides

Understanding the atomic-scale mechanisms that govern the structure of interfaces is critical across materials systems but particularly so for two-dimensional (2D) moiré materials. Here, we image, atom-by-atom, the thermally induced structural evolution of twisted bilayer transition metal dichalcogenides using in situ transmission electron microscopy. We observe low-temperature, local conversion of moiré superlattice into nanoscale aligned domains. Unexpectedly, this process occurs by nucleating a new grain within one monolayer, whose crystal orientation is templated by the other. The aligned domains grow through collective rotation of moiré supercells and hopping of 5|7 defect pairs at moiré boundaries. This provides mechanistic insight into the atomic-scale interactions controlling moiré structures and illustrates the potential to pattern interfacial structure and properties of 2D materials at the nanoscale.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Focal plane transport assembly for the HEAO-B X-ray telescope

The High Energy Astronomy Observatory - Mission B (HEAO-B), an earth orbiting X-ray telescope facility capable of locating and imaging celestial X-ray sources within one second of arc in the celestial sphere, is considered. The Focal Plane Transport Assembly (FPTA) is one of the basic structural elements of the three thousand pound HEAO-B experiment payload. The FPTA is a multifunctional assembly which supports seven imaging X-ray detectors circumferentially about a central shaft and accurately positions any particular one into the focus of a high resolution mirror assembly. A drive system, position sensor, rotary coupler, and detent alignment system, all an integral part of the rotatable portion which in turn is supported by main bearings to the stationary focal plane housing are described.

Brissette, R.↗

Coherent mesoscale convection patterns during northward interplanetary magnetic field

Coincident DE 2 satellite plasma-drift and particle measurements and all-sky imaging photometer data were used to construct two-dimensional convection patterns in a study of polar ionospheric convection in the presence of subvisual-intensity soft-particle excited 6300-A sun-aligned polar cap arcs. Results show a highly anisotropic temporally stable convection with greater order than has previously been suspected.

Carlson, H. C.↗

VETA x ray data acquisition and control system

We describe the X-ray Data Acquisition and Control System (XDACS) used together with the X-ray Detection System (XDS) to characterize the X-ray image during testing of the AXAF P1/H1 mirror pair at the MSFC X-ray Calibration Facility. A variety of X-ray data were acquired, analyzed and archived during the testing including: mirror alignment, encircled energy, effective area, point spread function, system housekeeping and proportional counter window uniformity data. The system architecture is presented with emphasis placed on key features that include a layered UNIX tool approach, dedicated subsystem controllers, real-time X-window displays, flexibility in combining tools, network connectivity and system extensibility. The VETA test data archive is also described.

Brissenden, Roger J. V.↗

VETA X-ray Data Acquisition and Control System

We describe the X-ray Data Acquisition and Control System (XDACS) used together with the X-ray Detection System (XDS) to characterize the X-ray image during testing of the AXAF P1/H1 mirror pair at the MSFC X-ray Calibration Facility. A variety of X-ray data were acquired, analyzed and archived during the testing including: mirror alignment, encircled energy, effective area, point spread function, system housekeeping and proportional counter window uniformity data. The system architecture is presented with emphasis placed on key features that include a layered UNIX tool approach, dedicated subsystem controllers, real-time X-window displays, flexibility in combining tools, network connectivity and system extensibility. The VETA test data archive is also described.

Brissenden, Roger J. V.↗

VETA x ray data acquisition and control system

We describe the X-ray Data Acquisition and Control System (XDACS) used together with the X-ray Detection System (XDS) to characterize the x-ray image during testing of the AXAF P1/H1 mirror pair at the MSFC X-ray Calibration Facility. A variety of x-ray data were acquired, analyzed, and archived during the testing including: mirror alignment, encircled energy, effective area, point spread function, system housekeeping, and proportional counter window uniformity data. The system architecture will be presented with emphasis placed on key features that include a layered UNIX tool approach, dedicated subsystem controllers, real-time X-window displays, flexibility in combining tools, network connectivity, and system extensibility. The VETA test data archive are also described.

Brissenden, R. J. V.↗

An overview of vertebrate mineralization with emphasis on collagen-mineral interaction

The nucleation, growth, and development of mineral crystals through their interaction principally with collagen in normal bone and calcifying tendon have been elaborated by applying a number of different techniques for analysis of the inorganic and organic constituents of these tissues. The methods have included conventional and high voltage electron microscopy, electron diffraction, microscopic tomography and 3D image reconstruction, and atomic force microscopy. This summary presents results of these studies that have now characterized the size, shape, and aspects of the chemical nature of the crystals as well as their orientation, alignment, location, and distribution with respect to collagen. These data have provided the means for understanding more completely the formation and strength of the collagen-mineral composite present in most vertebrate calcifying tissues and, from that information, a basis for the adaptation of such tissues under mechanical constraints. In the context of the latter point, other data are given showing effects on collagen in bone cell cultures subjected to the unloading parameters of spaceflight. Implications of these results may be particularly relevant to explaining loss of bone by humans and other vertebrate animals during missions in space, during situations of extended fracture healing, long-term bedrest, physical immobilization, and related conditions. In a broader sense, the data speak to the response of bone and mineralized vertebrate tissues to changes in gravitational loading and applied mechanical forces in general.

Non-NASA Center↗

Research and Development of External Occultor Technology for the Direct Observation of Extrasolar Planetary Systems : JPL Starshades Project

Our group conducted work during the Summer of 2012 assembling and developing JPL's Starshades Project under the Technology Development for Exoplanet Missions(TDEM) initiative created by NASA, specifically TDEM stage 2. The goal of the work conducted at JPL by our group was to construct four occultor petals, the main optical components of the Starshade, for the analysis of joint deployment characteristics and of mechanical strain. A Starshade is an optical structure measuring approximately 30 meters in diameter that uses the effects of light diffraction off sheer edges, light scattering, and negative interference between waves to negate all on-axis light in a telescope's image, providing very high contrast that allows planets orbiting a target star to be observed. We completed our engineering goals in the time span of 10 weeks, during which the assembly processes of manufacture, alignment, and structural bonding took place. The Starshade technology and construction process is further discussed in the body of this paper.

exoplanet missions↗

Research and development of external occultor technology for the direct observation of extrasolar planetary systems : JPL Starshades Project

Our group conducted work during the Summer of 2012 assembling and developing JPL's Starshades Project under the Technology Development for Exoplanet Missions(TDEM) initiative created by NASA, specically TDEM stage 2. The goal of the work conducted at JPL by our group was to construct four occultor petals, the main optical components of the Starshade, for the analysis of joint deployment characteristics and of mechanical strain. A Starshade is an optical structure measuring approximately 30 meters in diameter that uses the effects of light difraction of sheer edges, light scattering, and negative interference between waves to negate all on-axis light in a telescope's image, providing very high contrast that allows planets orbiting a target star to be observed. We completed our engineering goals in the time span of 10 weeks, during which the assembly processes of manufacture, alignment, and structural bonding took place. The Starshade technology and construction process is further discussed in the body of this paper.

Stadeler, Herbert Franz Mehnert↗