Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “home performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Heat-Exchange in One-Phase Liquid-Metal Flows: Databank (Temperature Distribution in Circular Pipes)

In order to develop accurate methods of calculating heat-exchange in forced channel flows, it is necessary to have knowledge about the temperature distribution over the cross section in differ layers of the flow. For ordinary liquids (gas, water, where the Prandtl number Pr ~ 1), such measurements are difficult to perform because of the small thickness of the boundary layer. The problem simplifies for liquid metals, where Pr << 1. This article contains the format of the data as well as an analysis of the primary data from 37 home and foreign works (mercury, sodium-potassium alloy, sodium, lithium, lead-bismuth alloy). The data are presented in electronic form.

42 ENGINEERING↗

Optimizing the ORR activity of Pd based nanocatalysts by tuning their strain and particle size

Controlling of the particle size and surface strain is the key to tuning the surface chemistry and optimizing the catalytic performance of electrocatalysts. In this study, we show that by introducing both Fe and Co into Pd lattices, the surface strain of Pd nanocatalysts can be tuned to optimize their oxygen reduction activity in both fuel cells and Zn–air batteries. The Pd 2 FeCo/C alloy particles are uniquely coated with an ultrathin Fe 2 O 3 shell which is in situ formed during a thermal annealing treatment. The thin shell acts as an effective barrier that prevents the coalescence and ripening of Pd 2 FeCo/C nanoparticles. Compared with Pd/C, Pd 2 FeCo/C exhibits higher catalytic activity and long-term stability for the ORR, signifying changes in catalytic behavior due to particle sizes and strain effects. Moreover, by spontaneous decoration of Pt on the surface of Pd 2 FeCo/C, the Pd 2 FeCo@Pt/C core@shell structure was formed and the Pt mass activity was about 37.6 and 112.5 times higher than that on Pt/C in a 0.1 M HClO 4 and KOH solution at 0.9 V, respectively, suggesting an enhanced ORR performance after Pt decoration. More interestingly, Pd 2 FeCo@Pt/C also shows a power density of ~308 mW cm -2 , which is much higher than that of Pt/C (175 mW cm -2 ), and excellent durability in a home-made Zn–air battery.

25 ENERGY STORAGE↗

Using Public Participation to Improve MELs Energy Data Collection

Miscellaneous Electric Loads (MELs) have proliferated in the last decade, and comprise an increasing share of building energy consumption. Because of the diversity of MELs and our lack of understanding about how people use them, large-scale data collection is needed to inform meaningful energy reduction strategies. Traditional methods of data collection, however, usually incur high labor and metering equipment expenses. As an alternative, this paper investigates the feasibility of crowdsourcing data collection to satisfy at least part of the data collection needs with acceptable accuracy. This study assessed the reliability and accuracy of crowdsourced data, by recruiting over 20 volunteers (from the 2012 Lawrence Berkeley Lab, Open House event) to test our crowdsourcing protocol. The protocol asked volunteers to perform the following tasks for three test products with increasing complexity - record power meter and product characteristics, identify all power settings available, and report the measured power. Based on our collected data and analysis, we concluded that volunteers performed reasonably well for devices with functionalities with which they are familiar, and might not produce highly accurate field measurements for complex devices. Accuracy will likely improve when participants are measuring the power used by devices in their home which they know how to operate, by providing more specific instructions including instructional videos. When integrated with existing programs such as the Home Energy Saver tool, crowdsourcing data collection from individual homeowners has the potential to generate a substantial amount of information about MELs energy use in homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Administration of H-Prize Final Report

The Hydrogen Education Foundation (HEF) administrated the H-Prize, a program authorized by Congress in 2007 to incentivize innovative technology development in the hydrogen and fuel cell sector. Under this authorization, DOE allocated $\$$1 million for one Prize. DOE selected HEF competitively in 2008 to administer the competition, perform fundraising activities to develop a robust prize program, and perform marketing and communications, from 2008 to 2017. HEF administered two H-Prize competitions for DOE, the first for development of hydrogen storage materials for use on board fuel cell electric vehicles, and the second for a home or community sized hydrogen fueling system. HEF marketed the competitions through industry channels, at industry meetings, a specialized website and press releases to obtain entrants to the competitions. HEF provided assistance to the DOE for development of the judging criteria, and administered the judging and the final decision processes. In parallel, HEF sought additional prize funding from industry and foundations to expand the number of potential competitions and the amount of future prizes, consistent with the Congressional authorization of H-Prize. The first prize sought the development of a hydrogen storage material that could meet DOE’s criteria for onboard storage. This competition did not achieve any entrants that met the requirements. The second prize was for a small-scale hydrogen fueling system. The $\$$1 million prize was awarded to the industry consortium SimpleFuel for their home hydrogen refueling system. HEF executed a three-pronged strategy for raising funds to expand the competitions through private (non-public) funding – corporate contributions consistent with company interests; foundation contributions consistent with their goals; and individual contributions, principally through the United Way Campaigns. For a variety of reasons, HEF did not achieve the envisioned fundraising goals, which made it difficult to achieve the excitement originally envisioned by the H-Prize Congressional authors. Originally planned as a multi-year, multi-prize competition, an expansion of H-Prize to additional competitions with potentially larger awards did not happen. Prize competitions remain a useful way to stimulate technological innovation by researchers and product developers. Creating excitement through topic selection and harmony with important and achievable energy goals that inspire both applicants and their development work, and prize funders, is key.

08 HYDROGEN↗

Validation of the Public Radiation Exposure Calculation for the Incident at the National Institute of Standards and Technology Center for Neutron Research on February 3, 2021

The Department of Energy/National Nuclear Security Administration Consequence Management Program was contacted by the Health Physics Chief of the National Institute of Standards and Technology Center for Neutron Research (NCNR) to review public radiation exposure calculations for an event that occurred on its Gaithersburg, Maryland, campus on February 3, 2021. Subject matter experts from the Nuclear Emergency Support Team (NEST) assets, specifically the Consequence Management Home Team (CMHT) and the National Atmospheric Release Advisory Center (NARAC), were selected to provide support. CMHT used three separate modeling codes to validate the results the scientists at NCNR calculated using the HotSpot model. The analyses were performed using NARAC’s in-house Lagrangian dispersion codes known as LODI and Aeolus, as well as the Turbo FRMAC software from Sandia National Laboratories. The team used parameters provided by the NCNR scientists regarding the site, applicable observable meteorological data, and environmental survey and sampling data to estimate public exposure. Each model estimated public dose at much less than 0.5 mrem. CMHT concurs with the NCNR public radiation exposure calculations which state that members of the public at the 400-meter boundary would have received a radiological dose of less than 0.5 mrem.

61 RADIATION PROTECTION AND DOSIMETRY↗

Infiltration Effects on Residential Pollutant Concentrations for Continuous and Intermittent Mechanical Ventilation Approaches

The prevailing residential ventilation standard in North America, American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) Standard 62.2, specifies volumetric airflow requirements as a function of the overall size of the home and the number of bedrooms, assumes a fixed, minimal amount of infiltration, and requires mechanical ventilation to achieve the remainder. The standard allows for infiltration credits and intermittent ventilation patterns that can be shown to provide comparable performance. Whole-house ventilation methods have a substantial effect on time-varying indoor pollutant concentrations. If alternatives specified by Standard 62.2, such as intermittent ventilation, are used, short-term pollutant concentrations could exceed acute health standards even if chronic health standards are met.The authors present a methodology for comparing ASHRAE- and non-ASHRAE-specified ventilation scenarios on relative indoor pollutant concentrations. We use numerical modeling to compare the maximum time-averaged concentrations for acute exposure relevant (1-hour, 8-hour, 24-hour ) and chronic exposure relevant (1-year) time periods for four different ventilation scenarios in six climates with a range of normalized leakage values. The results suggest that long-term concentrations are the most important metric for assessing the effectiveness of whole-house ventilation systems in meeting exposure standards and that, if chronic health exposure standards are met, acute standards will also be met.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Residents' annoyance responses to aircraft noise events

In a study conducted in the vicinity of Salt Lake City International Airport, community residents reported their annoyance with individual aircraft flyovers during rating sessions conducted in their homes. Annoyance ratings were obtained at different times of the day. Aircraft noise levels were measured, and other characteristics of the aircraft were noted by trained observers. Metrics commonly used for assessing aircraft noise were compared, but none performed significantly better than A-weighted sound pressure level. A significant difference was found between the ratings of commercial jet aircraft and general aviation propeller aircraft, with the latter being judged less annoying. After the effects of noise level were accounted for, no significant differences were found between the ratings of landings and takeoffs. Aircraft noise annoyance reactions are stronger in lowered ambient noise conditions. This is consistent with the theory that reduced nighttime and evening ambient levels could create different reactions at different times of day. After controlling for ambient noise in a multiple regression analysis, no significant differences were found between the ratings of single events obtained during the three time periods: morning, afternoon, and evenings.

Dempsey, T. K.↗

ACRV derived transportation system

Alternate means for manned transportation to low earth orbit are being considered by NASA to complement and eventually replace the Space Shuttle. One method of achieving two-way transportation is through the modification of Assured Crew Return Vehicle (ACRV). The ACRV is a manned transportation system designed to bring home Space Station Freedom crews in the event of an emergency or Shuttle standdown. The ACRV is launched in the Space Shuttle-payload bay and is designed for earth return from low earth orbit. A study was performed that addressed the modification of an ACRV into a two-way manned transportation system. The Station Crew Return Alternate Module (SCRAM) configuration was chosen as the reference ACRV vehicle. This paper will discuss the requirements and ground rules used in the study as well as the design modifications made to the ACRV.

Peterson, Wayne L.↗

Crew Factors in Flight Operations XII: A Survey of Sleep Quantity and Quality in On-Board Crew Rest Facilities

Many aircraft operated on long-haul commercial airline flights are equipped with on-board crew rest facilities, or bunks, to allow crewmembers to rest during the flight. The primary objectives of this study were to gather data on how the bunks were used, the quantity and quality of sleep obtained by flight crewmembers in the facilities, and the factors that affected their sleep. A retrospective survey comprising 54 questions of varied format addressed demographics, home sleep habits, and bunk sleep habits. Crewmembers from three airlines with long-haul fleets carrying augmented crews consisting of B747-100/200, B747-400, and MD-11 aircraft equipped with bunks returned a total of 1404 completed surveys (a 37% response rate). Crewmembers from the three carriers were comparable demographically, although one carrier had older, more experienced flight crewmembers. Each group, on average, rated themselves as "good" or "very good" sleepers at home, and all groups obtained about the same average amount of sleep each night. Most were able to sleep in the bunks, and about two thirds indicated that these rest opportunities benefited their subsequent flight deck alertness and performance. Comfort, environment, and physiology (e.g., being ready for sleep) were identified as factors that most promoted sleep. Factors cited as interfering with sleep included random noise, thoughts, heat, and the need to use the bathroom. These factors, in turn, suggest potential improvements to bunk facilities and their use. Ratings of the three aircraft types suggested differences among facilities. Bunks in the MD-11 were rated significantly better than either of the B747 types, and the B747-400 bunks received better ratings than did the older, B747-100/200 facilities.

Rosekind, Mark R.↗

Energy Implications of In-Line Filtration in California

Occupant concern about indoor air quality (IAQ) issues has led to the increased use of more effective air filters in residential heating and cooling systems. This study performed measurements in ten California houses to determine the effects of changing filter performance and related characteristics on the energy use of the heating and cooling systems. Multiple filters were evaluated covering a wide range of filter effectiveness from simple low filtration fiberglass filters up to high efficiency filters that might be used by occupants concerned about IAQ. Sophisticated analysis and simulation tools used the field-testing results to determine filter impacts for a wide range of parameters and California climates. The results indicate that for MERV 10/11/13 filters the effects on energy use are moderate (<5%) over a wide range of performance conditions and climates. Using higher MERV 16 filters can lead to significantly increased energy use (>5%). The high airflow resistance of MERV 16 filters led to excess noise in some test houses from air bypassing the filter and the blower motor. Filter loading rates varied more from house to house than by MERV rating and overall were quite low in many of the homes. Filter related energy use does not need to be addressed for filters of MERV 10/11/13 and MERV 16 filters should only be used with low leakage tested ducts unless the filter is mounted at the blower compartment. MERV 16 filters should only be used if the filter area is sufficient to prevent noise issues and if the duct system has low air flow resistance and low leakage. Filters should be labeled for their air flow resistance, or static pressure at a particular flow rate, that would allow codes and standards to reference a particular performance specification and allow contractors and homeowners to make informed purchases.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Palliative Treatment of Rectal Carcinoma Recurrence Using Radiofrequency Ablation

Purpose: To evaluate the safety and efficacy of CT-guided radiofrequency (RF) ablation for the palliative treatment of recurrent unresectable rectal tumors. Materials and Methods: Twenty-seven patients with locally recurrent rectal cancer were treated with computed tomography (CT)-guided RF ablation. Therapy was performed with the patient under conscious sedation with a seven- or a nine-array expandable RF electrode for 8-10 min at 80-110 Degree-Sign C and a power of 90-110 W. All patients went home under instructions the next day of the procedure. Brief Pain Inventory score was calculated before and after (1 day, 1 week, 1 month, 3 months, and 6 months) treatment. Results: Complete tumor necrosis rate was 77.8% (21 of a total 27 procedures) despite lesion location. BPI score was dramatically decreased after the procedure. The mean preprocedure BPI score was 6.59, which decreased to 3.15, 1.15, and 0.11 at postprocedure day 1, week 1, and month 1, respectively, after the procedure. This decrease was significant (p < 0.01 for the first day and p < 0.001 for the rest of the follow-up intervals (paired Student t test; n - 1 = 26) for all periods during follow-up. Six patients had partial tumor necrosis, and we were attempted to them with a second procedure. Although the necrosis area showed a radiographic increase, no complete necrosis was achieved (secondary success rate 65.6%). No immediate or delayed complications were observed. Conclusion: CT-guided RF ablation is a minimally invasive, safe, and highly effective technique for treatment of malignant rectal recurrence. The method is well tolerated by patients, and pain relief is quickly achieved.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A versatile femtosecond stimulated Raman spectroscopy setup with tunable pulses in the visible to near infrared

We demonstrate a versatile and efficient setup to perform femtosecond stimulated Raman spectroscopy (FSRS). Technical innovations are implemented to achieve the wavelength tunability for both the picosecond narrowband Raman pump pulse and femtosecond broadband Raman probe pulse. Using a simplified one-grating scheme in a home-built second harmonic bandwidth compressor followed by a two-stage noncollinear optical parametric amplifier, we tune the Raman pump pulse from ca. 480 to 750 nm. To generate the suitable Raman probe pulse in tandem, we rely on our recently demonstrated broadband up-converted multicolor array technique that readily provides tunable broadband laser sidebands across the visible to near-infrared range. This unique setup has unparalleled flexibility for conducting FSRS. We measure the ground-state Raman spectra of a cyclohexane standard using tunable pump-probe pairs at various wavelengths across the visible region. The best spectral resolution is ∼12 cm{sup −1}. By tuning the pump wavelength closer to the electronic absorption band of a photoacid pyranine in water, we observe the pre-resonantly enhanced Raman signal. The stimulated Raman gain of the 1627 cm{sup −1} mode is increased by over 15 times.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Durability of ABC Team Wall Assemblies

This study evaluates the long-term hygrothermal durability of four advanced retrofit wall systems using a field test facility located in Hollywood, South Carolina, representative of a mixed-humid coastal climate (Zone 3). The research focuses on assessing the thermal and moisture performance of a baseline wall assembly retrofitted with (1) Tremco/Dryvit prefabricated panel systems (Revitalite and Fedderlite), (2) Reinforced Fiberglass Plastic (RFP) panels developed by Oak Ridge National Laboratory (ORNL), and (3) Vacuum Insulated Panels (VIP) integrated with EPS by Home Innovation Research Labs (HIRL) and ORNL. A baseline wall representing a typical uninsulated wood-frame construction was used for comparison.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measure Guideline: Deep Energy Enclosure Retrofit for Interior Insulation of Masonry Walls and Flat Roofs

Measure Guideline: Deep Energy Enclosure Retrofit for Zero Energy Ready House Flat Roofs BSC TO5 Task 7.4 Deep Energy Enclosure Retrofit (DEER) for Interior Insulation of Masonry Walls Lawrence, MA 01840 This Measure Guideline describes a deep energy enclosure retrofit solution for insulating mass masonry buildings from the interior. It describes the retrofit assembly, technical details, and installation sequence for retrofitting masonry walls. Interior insulation of masonry retrofits might adversely affect the durability of the wall. This guideline includes a review of decision criteria pertinent to retrofitting masonry walls from the interior and the possible risk of freeze-thaw damage. This Measure Guideline is intended to support contractors who are implementing an interior insulation-based high-performance enclosure retrofit for masonry buildings and designers who are looking to design such retrofits. It may also be helpful to building owners who wish to learn more about strategies that are available for deep energy enclosure retrofit of masonry residential buildings on the interior. This Measure Guideline is important to the high-performance retrofit industry because the solution described here provides an opportunity to retrofit masonry buildings with ambitious energy performance goals by insulating them from the interior without disturbing their exterior appearance. BSC TO5 Task 7.4 Deep Energy Enclosure Retrofit (DEER) for Zero Energy Ready House (ZERH) Flat Roofs House Jamaica Plain, MA 02130 This Measure Guideline provides design and construction information for a deep energy enclosure retrofit solution of a flat roof assembly. It describes the strategies and procedures for an exterior retrofit of a flat wood-framed roof with brick masonry exterior walls using exterior and interior (framing cavity) insulation. The approach supported in this guide could also be adapted for use with flat wood-framed roofs with wood-framed exterior walls. Designers, contractors, and building code officials will benefit from the information contained in this Measure Guideline. The guide may also be helpful to building owners who wish to learn more about strategies for deep energy enclosure retrofit of flat roofs. This Measure Guideline is important to the high-performance retrofit industry because it demonstrates techniques for retrofitting flat roofs from the exterior, which is less disruptive to the living space and allows the structure to remain occupied during the project. It also illustrates a solution for preparing homes to become zero energy ready.

Array↗

Microbial Monitoring and the Risk of Infectious Disease Aboard the International Space Station

The International Space Station (ISS) is a semi-closed habitat in low Earth orbit with environmental conditions provided by an advanced life support system that controls temperature and recycles air and most of the potable water. The crew's activities, such as eating, sleeping, hygiene, and laboratory research, are performed in relatively close proximity. Research in the laboratory includes a myriad of experiments, including those with rodents, plants, and pathogenic microorganisms. Despite these conditions, in-flight monitoring of ISS indicates that the microbial diversity is similar to homes on earth. Accordingly, the crew is generally very healthy, however infectious disease does occur and potential routes of infection by obligate and opportunistic pathogens cannot be completely prevented. Determining the extent of this risk is further complicated, as microorganisms can alter their characteristics in response to spaceflight culture, as exemplified by the increase in virulence of the enteric pathogen Salmonella enterica Typhimurium during spaceflight compared to otherwise identical cultures grown on Earth. Taken together, these factors suggest a need for continued microbiological monitoring and research to understand and mitigate the risk of infectious disease during long duration missions.

Ott, C. Mark↗

Using Public Participation to Improve MELs Energy Data Collection

Miscellaneous and electronic loads (MELs) comprise an increasing share of building energy consumption. Large-scale data collection is needed to inform meaningful energy reduction strategies because of the diversity of MELs and our lack of understanding about how people use them. Traditional methods of data collection, however, usually incur high labor and metering equipment expenses. As an alternative, this paper investigates the feasibility of crowdsourcing data collection to satisfy at least part of the data collection needs with acceptable accuracy. We assessed the reliability and accuracy of crowd-sourced data by recruiting 18 volunteers and testing our crowdsourcing protocol. The protocol asked volunteers to perform measurement tasks for three MELs devices of increasing complexity 1) record power meter and MELs product characteristics, 2) identify and measure all power modes available, and 3) report the measured power. Volunteers performed reasonably well for devices with functionalities with which they were familiar, but many could not correctly identify all available power modes in complex devices. Accuracy may improve when participants measure the power used by familiar devices in their home, or by providing more specific instructions, e.g. videos. Furthermore, crowdsourcing data collection from individual homeowners has the potential to generate valuable information about MELs energy use in homes when integrated with existing programs such as Home Energy Saver and Building America.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Stand-Off Furring in Deep Energy Retrofits: Syracuse, New York (Fact Sheet)

IBACOS, in collaboration with GreenHomes America, was contracted by the New York State Energy Research and Development Authority to research exterior wall insulation solutions. This research investigated cost-effective deep energy retrofit (DER) solutions for improving the building shell exterior while achieving a cost-reduction goal, including reduced labor costs to reach a 50/50 split between material and labor. The strategies included exterior wall insulation plus energy upgrades as needed in the attic, mechanical and ventilation systems, and basement band joist, walls, and floors. The work can be integrated with other home improvements such as siding or window replacement. This strategy minimizes physical connections to existing wall studs, encapsulates existing siding materials (including lead paint) with spray foam, and creates a vented rain screen assembly to promote drying. GreenHomes America applied construction details created by IBACOS to a test home. 2x4 framing members were attached to the wall at band joists and top plates using 'L' clips, with spray foam insulating the wall after framing was installed. Windows were installed simultaneously with the framing, including extension jambs. The use of clips in specific areas provided the best strength potential, and 'picture framing' the spray foam held the 2x4s in place. Short-term testing was performed at this house, with monitoring equipment installed for long-term testing. Testing measurements will be provided in a later report, as well as utility impact (before and after), costs (labor and materials), construction time, standard specifications, and analysis for the exterior wall insulation strategy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Residential Battery Modeling for Control-Oriented Techno-Economic Studies: Preprint

Electrochemical batteries, which serve as electric energy storage devices, are becoming increasingly popular among residential buildings that incorporate solar photovoltaic (PV) systems to help meet their energy needs. Battery economics are affected by performance degradation over time, and managing this degradation can help extend the battery's lifespan. The tradeoff between operational costs/benefits and managing battery degradation is of significant research interest. One of the key factors for assessing battery degradation is the dispatch strategy used to control the charging and discharging of the battery. Conventional dispatch strategies typically use simple rule-based methods, and these overly aggressive charging/discharging cycles can significantly reduce a battery’s life span. Our research seeks to develop optimized dispatch strategies for grid-connected PV homes with a goal of extending battery life while simultaneously taking into consideration utility costs and occupant comfort. To achieve this goal, we adapted lithium-ion battery life- and cyclic-degradation models for use in high-fidelity building simulations, so whole-building and grid-interactive controllers can dispatch the batteries along with other flexible loads. With the help of a co-simulation platform, we performed a simulation study to compute the optimized dispatch strategies for relevant operating conditions brought about by changing geographical locations, weather conditions, and utility pricing. Comparing the optimized strategies with the conventional strategies resulted in a >50% decrease in capacity degradation and >10% average reduction in operational costs during the months of January and July in Fort Collins, Colorado; Phoenix, Arizona; and Portland, Oregon.

30 DIRECT ENERGY CONVERSION↗