Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “harmonic analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

tell: a Python package to model future total electricity loads in the United States

The purpose of the Total ELectricity Load (tell) model is to generate 21st century profiles of hourly electricity load (demand) across the Conterminous United States (CONUS). tell loads reflect the impact of climate and socioeconomic change at a spatial and temporal resolution adequate for input to an electricity grid operations model. tell uses machine learning to develop profiles that are driven by projections of climate/meteorology and population. tell also harmonizes its results with United States (U.S.) state-level, annual projections from a national- to global-scale energy-economy model. This model accounts for a wide range of other factors affecting electricity demand, including technology change in the building sector, energy prices, and demand elasticities, which stems from model coupling with the U.S. version of the Global Change Analysis Model (GCAM-USA). tell was developed as part of the Integrated Multisector Multiscale Modeling (IM3) project. IM3 explores the vulnerability and resilience of interacting energy, water, land, and urban systems in response to compound stressors, such as climate trends, extreme events, population, urbanization, energy system transitions, and technology change

24 POWER TRANSMISSION AND DISTRIBUTION↗

Parametric study of turbine blade platform friction damping using the lumped parameter analysis

The hardware configuration used in the present study of turbine blade planform friction damping, by means of the lumped parameter analysis, is the first turbine stage of the Space Shuttle Main Engine's High Pressure Fuel Turbopump. The analysis procedure solves the nonlinear equations of motion for a turbine blade that is acted on by a platform friction damper, using an iterative matrix method. Attention is given to the effects on blade deflection response of variations in friction coefficient, the normal force on the friction surface interface, blade hysteretic damping, the blade-to-blade phase angle of the harmonic forcing function, and the amplitude of the forcing function.

Dominic, R. J.↗

Effect of helicopter blade dynamics on blade aerodynamic and structural loads

The effect of rotor blade dynamics on aerodynamic and structural loads is examined for a conventional, main-rotor helicopter using a comprehensive rotorcraft analysis (CAMRAD) and flight-test data. The impact of blade dynamics on blade section lift-coefficient time histories is studied by comparing predictions from a rigid-blade analysis and an elastic-blade analysis with helicopter flight test data. The elastic blade analysis better predicts high-frequency behavior of section lift. In addition, components of the blade angle of attack such as elastic blade twist, blade flap rate, blade slope velocity, and inflow are examined as a function of blade mode. Elastic blade motion changed blade angle of attack by a few tenths of a degree, and up to the sixth rotor harmonic. A similar study of the influence of blade dynamics on bending and torsion moments was also conducted. A correlation study comparing predictions from several elastic-blade analyses with flight-test data revealed that an elastic-blade model consisting of only three elastic bending modes (first and second flap and first lag), and two elastic torsion modes was sufficient for good correlation.

Heffernan, Ruth M.↗

Three-dimensional potential flows from functions of a 3D complex variable

Potential, or ideal, flow velocities can be found from the gradient of an harmonic function. An ordinary complex valued analytic function can be written as the sum of two real valued functions, both of which are harmonic. Thus, 2D complex valued functions serve as a source of functions that describe two-dimensional potential flows. However, this use of complex variables has been limited to two-dimensions. Recently, a new system of three-dimensional complex variables has been developed at the NASA Ames Research Center. As a step toward application of this theory to the analysis of 3D potential flow, several functions of a three-dimensional complex variable have been investigated. The results for two such functions, the 3D exponential and 3D logarithm, are presented in this paper. Potential flows found from these functions are investigated. Important characteristics of these flows fields are noted.

Kelly, Patrick↗

Theory for noise of propellers in angular inflow with parametric studies and experimental verification

This report presents the derivation of a frequency domain theory and working equations for radiation of propeller harmonic noise in the presence of angular inflow. In applying the acoustic analogy, integration over the tangential coordinate of the source region is performed numerically, permitting the equations to be solved without approximation for any degree of angular inflow. Inflow angle is specified in terms of yaw, pitch, and roll angles of the aircraft. Since these can be arbitrarily large, the analysis applies with equal accuracy to propellers and helicopter rotors. For thickness and loading, the derivation is given in complete detail with working equations for near and far field. However, the quadrupole derivation has been carried only far enough to show feasibility of the numerical approach. Explicit formulas are presented for computation of source elements, evaluation of Green's functions, and location of observer points in various visual and retarded coordinate systems. The resulting computer program, called WOBBLE has been written in FORTRAN and follows the notation of this report very closely. The new theory is explored to establish the effects of varying inflow angle on axial and circumferential directivity. Also, parametric studies were performed to evaluate various phenomena outside the capabilities of earlier theories, such as an unsteady thickness effect. Validity of the theory was established by comparison with test data from conventional propellers and Prop Fans in flight and in wind tunnels under a variety of operating conditions and inflow angles.

Propeller acoustics↗

Dynamic Response of a Planetary Gear System Using a Finite Element/Contact Mechanics Model

The dynamic response of a helicopter planetary gear system is examined over a wide range of operating speeds and torques. The analysis tool is a unique, semianalytical finite element formulation that admits precise representation of the tooth geometry and contact forces that are crucial in gear dynamics. Importantly, no a priori specification of static transmission error excitation or mesh frequency variation is required; the dynamic contact forces are evaluated internally at each time step. The calculated response shows classical resonances when a harmonic of mesh frequency coincides with a natural frequency. However, peculiar behavior occurs where resonances expected to be excited at a given speed are absent. This absence of particular modes is explained by analytical relationships that depend on the planetary configuration and mesh frequency harmonic. The torque sensitivity of the dynamic response is examined and compared to static analyses. Rotation mode response is shown to be more sensitive to input torque than translational mode response.

Parker, Robert G.↗

Submillimeter Laboratory Investigations: Spectroscopy and Collisions

Currently, millimeter-wave and submillimeter-wave spectroscopy is conducted in our laboratory on several different types of spectrometers. Our standard spectrometer utilizes the output of a phase-locked klystron operating in the 40-60 GHz region, which is sent into a crossed-waveguide harmonic generator, or "multiplier". The high frequency millimeter-and submillimeter-wave radiation is transmitted via quasi-optical techniques through an absorption cell and then onto a detector, which is either an InSb hot electron bolometer cooled to 1.4 K or a Si bolometer cooled to 0.3 K. The detector response is sent to a computer for measurement and analysis. The frequency range produced and detected in this manner goes from 80 GHz to upwards of 1 THz. Spectra are normally taken with source modulation, with line frequencies typically measured to an accuracy of 50-100 kHz. Higher accuracy is available when needed. Recently, we developed a new, broad-band spectrometer in our laboratory based on a free-running backward wave oscillator (BWO) of Russian manufacture as the primary source of radiation. The so-called FASSST (fast-scan submillimeter spectroscopic technique) system uses fast-scan and optical calibration methods rather than the traditional locking techniques. The output power from the BWO is split such that 90% goes into the absorption cell while 10% is coupled to a 40-meter Fabry-Perot cavity, which yields fringe? for frequency measurement. Results from this spectrometer on the spectrum of nitric acid (HNO3) show that 100 GHz of spectral data can be obtained in 5 seconds with a measurement accuracy of 50 kHz. Currently, the frequency range of the FASSST system in our laboratory is roughly 100-700 GHz.

Herbst, Eric↗

Effect of higher harmonic control on helicopter rotor blade-vortex interaction noise: Prediction and initial validation

The paper presents a status of theoretical tools of AFDD, DLR, NASA and ONERA for prediction of the effect of HHC on helicopter main rotor BVI noise. Aeroacoustic predictions from the four research centers, concerning a wind tunnel simulation of a typical descent flight case without and with HHC are presented and compared. The results include blade deformation, geometry of interacting vortices, sectional loads and noise. Acoustic predictions are compared to experimental data. An analysis of the results provides a first insight of the mechanisms by which HHC may affect BVI noise.

Beaumier, P.↗

Optimal placement of tuning masses for vibration reduction in helicopter rotor blades

Described are methods for reducing vibration in helicopter rotor blades by determining optimum sizes and locations of tuning masses through formal mathematical optimization techniques. An optimization procedure is developed which employs the tuning masses and corresponding locations as design variables which are systematically changed to achieve low values of shear without a large mass penalty. The finite-element structural analysis of the blade and the optimization formulation require development of discretized expressions for two performance parameters: modal shaping parameter and modal shear amplitude. Matrix expressions for both quantities and their sensitivity derivatives are developed. Three optimization strategies are developed and tested. The first is based on minimizing the modal shaping parameter which indirectly reduces the modal shear amplitudes corresponding to each harmonic of airload. The second strategy reduces these amplitudes directly, and the third strategy reduces the shear as a function of time during a revolution of the blade. The first strategy works well for reducing the shear for one mode responding to a single harmonic of the airload, but has been found in some cases to be ineffective for more than one mode. The second and third strategies give similar results and show excellent reduction of the shear with a low mass penalty.

Pritchard, Jocelyn I.↗

Solid-state lasers for coherent communication and remote sensing

Semiconductor-diode laser-pumped solid-state lasers have properties that are superior to other lasers for the applications of coherent communication and remote sensing. These properties include efficiency, reliability, stability, and capability to be scaled to higher powers. We have demonstrated that an optical phase-locked loop can be used to lock the frequency of two diode-pumped 1.06 micron Nd:YAG lasers to levels required for coherent communication. Monolithic nonplanar ring oscillators constructed from solid pieces of the laser material provide better than 10 kHz frequency stability over 0.1 sec intervals. We have used active feedback stabilization of the cavity length of these lasers to demonstrate 0.3 Hz frequency stabilization relative to a reference cavity. We have performed experiments and analysis to show that optical parametric oscillators (OPO's) reproduce the frequency stability of the pump laser in outputs that can be tuned to arbitrary wavelengths. Another measurement performed in this program has demonstrated the sub-shot-noise character of correlations of the fluctuations in the twin output of OPO's. Measurements of nonlinear optical coefficients by phase-matched second harmonic generation are helping to resolve inconsistency in these important parameters.

Byer, Robert L.↗

Estimation of EOP From VLBI: Direct Approach

The currently adopted strategy of Earth Orientation Parameters (EOP) estimation from Very Long Baseline Interferometry (VLBI) is to estimate six parameters: Universal Time 1 (UT1), UT1 rate, pole positions, and nutation offsets for each 24-hour session independently. Then the resulting time series of raw EOP are filtered and a regression analysis is performed to obtain nutation coefficients, polhode of the pole, and other physical parameters. Thus, the latter parameters are obtained indirectly in two stages. An alternative approach of direct estimation of the final EOP is presented. Pole coordinates and UT1 are considered as a sum of three components: the low-period component that is modeled by a cubic spline, the harmonic component that includes forced nutation, precession and sub-daily variations of EOP, and the stochastic component that is modeled by a linear spline with segment length 1-2 hours. All parameters are obtained in a single LSQ solution using all available data.

POLAR MOTION↗

Application of GRACE to the Estimation of Groundwater Storage Change in a Data-poor Region: A Case Study of Ngadda Catchment in the Lake Chad Basin

The present study is to explore the feasibility of GRACE-based estimation of a groundwater storage change in a data-poor region using a case study of the Ngadda catchment in the Lake Chad Basin. Although the Ngadda catchment has only one set of in situ time series data of groundwater from 2006 to 2009 and a limited number of groundwater measurements in 2005 and 2009, GRACE-based groundwater storage change can be evaluated against thein situ groundwater measurements combined with specific yield data. The cross-correlation analysis in the Ngadda catchment shows that maximum rainfall reached in July and August, whereas both the maximum total water storage anomaly and the maximum groundwater storage anomaly occurred 2months later. Whereas the mean annual amplitude of total water storage anomaly is about 17cm from both the average total water storage anomaly from three mascon products and the one from three spherical harmonic products, the mean annual amplitude of soil moisture storage anomaly is substantially varied from5.58cm for CLM to about 14cm for NOAH and Mosaic. The goodness-of-fit tests show that CLM soil moisture produces the closest estimation of groundwater storage anomaly to thein situ groundwater measurements. The present study shows that GRACE-based estimation for groundwater storage anomaly can be a cost-effective and alternative tool to observe how groundwater changes in a basin scale under the limitation of modelling and in situ data availability.

GRACE↗

A preliminary error analysis of the gravity field recovery from a lunar Satellite-to-Satellite mission

A low cost lunar Satellite-to-Satellite radio tracking mission in a low-low configuration could considerably improve the existing knowledge about the lunar gravity field. The impact of various mission parameters that may contribute to the recovery of the gravity field, such as satellite altitude, satellite separation mission duration, measurement precision and sampling interval were quantified using the Jekeli-Rapp algorithm. Preliminary results indicate that the gravity field resolution up to harmonic degree 40 to 80 is feasible depending on various mission configurations. Radio tracking data from a six-month mission with a precision of 1 mm/s every 10 s and 300 km satellite separation at 150 km altitude will permit the determination of 5 deg x 5 deg mean gravity anomalies with an error of approximately 15 mgals. Consideration of other unaccounted error sources of instrumental, operational, and environmental nature may lower this resolution.

Iz, Huseyin B.↗

Membrane Vibration Analysis Above the Nyquist Limit with Fluorescence Videogrammetry

A new method for generating photogrammetric targets by projecting an array of laser beams onto a membrane doped with fluorescent laser dye has recently been developed. In this paper we review this new fluorescence based technique, then proceed to show how it can be used for dynamic measurements, and how a short pulsed (10 ns) laser allows the measurement of vibration modes at frequencies several times the sampling frequency. In addition, we present experimental results showing the determination of fundamental and harmonic vibration modes of a drum style dye-doped polymer membrane tautly mounted on a 12-inch circular hoop and excited with 30 Hz and 62 Hz sinusoidal acoustic waves. The projected laser dot pattern was generated by passing the beam from a pulsed Nd:YAG laser though a diffractive optical element, and the resulting fluorescence was imaged with three digital video cameras, all of which were synchronized with a pulse and delay generator. Although the video cameras are capable of 240 Hz frame rates, the laser s output was limited to 30 Hz and below. Consequently, aliasing techniques were used to allow the measurement of vibration modes up to 186 Hz with a Nyquist limit of less than 15 Hz.

Dorrington, Adrian A.↗

Time and space resolved diagnostics for plasma thermal-chemical instability of fuel oxidation in nanosecond plasma discharges

Here, an instability in a nanosecond pulsed dielectric barrier discharge plasma occurring in methane–oxygen–argon mixtures is experimentally observed and measured by 1D time-resolved in situ electric field measurements. This instability, which seems to be created by the positive feedback between plasma kinetics and plasma-assisted low temperature fuel oxidation, is studied using electric field induced second harmonic generation and direct ICCD imaging. The rapid formation of streamers from an originally uniform discharge appears to be caused by the chemical kinetics of plasma-assisted low temperature methane oxidation, which may be resulting in a new type of plasma instability: a thermal-chemical instability. The results also revealed that the occurrence of this possible thermal-chemical instability in a reactive flow drastically changes the plasma properties by forming multiple secondary discharges and possibly leads to micron-sized non-uniform electric distributions. Single shot uncalibrated measurements of the electric field of the micron sized streamers appears to show much greater strengths than the average electric field. Furthermore, one-dimensional data analysis shows the positive feedback loop between the streamers and the low temperature plasma assisted oxidation chemistry in the plasma thermal-chemical instability. The present finding advances the understanding plasma instability growth and provides a new way to control plasma uniformity in plasma-assisted combustion and plasma fuel reforming.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impacts of swinging door lossy compression of synchrophasor data

As the number of operational Phasor Measurement Units (PMUs) is increasing, compression is becoming crucial for efficiently transferring and storing enormous amount of synchrophasor data continuously measured from a power system. Some utilities in the U.S. have already adopted a nonlinear compression technique, called Swinging Door Algorithm (SDA), assuming compressed data meets technical and regulatory requirements without resulting in any degradation of the measurements. This paper studies impacts of this compression algorithm on field measured and simulated PMU data, and presents results from spectral analyses of raw and decompressed measurements. The results show blind application of the SDA compression alters frequency content in the measurements and introduces false harmonics and aliasing. These can lead to false conclusions being drawn from the measurements about the power system condition.

42 ENGINEERING↗

The Mariner 9 celestial mechanics experiment

There are two main objectives in the Mars gravity field analysis. The first is to generate a picture of the gravity field which can be used in conjunction with other types of data to elucidate the interior, surface structure, and history of Mars. The second is to aid the orbit determination aspect of the relativity experiment. In an effort to extract from the data a Mars gravity model of reasonable fidelity, various spherical harmonic models have been made. A parallel effort using a surface mass representation involves the differentiation of Doppler residuals for acceleration contours.

Lorell, J.↗

LDEF radiation measurements: preliminary results

The Long Duration Exposure Facility (LDEF), retrieved by the Space Shuttle mission STS-32 after nearly 6 yr in orbit, is the focus of a broad-based study of the radiation environment in low Earth orbit (LEO) and its effects on materials. A combination of passive techniques has been used to study this environment via detectors which were contained in experiments aboard the LDEF spacecraft and through analysis of induced radioactivities. Preliminary results for absorbed dose measurements and for induced activities in various materials are presented. A number of effects have been observed which reflect the anisotropy of the charged particle flux in low Earth orbit. Quantitative results from these measurements should provide an accurate means of confirming environmental flux models and techniques for predicting radiation encountered in future LEO missions, particularly those of extended duration.

NASA Discipline Number 00-00↗