Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

TU-AB-BRA-01: Abdominal Synthetic CT Generation in Support of Liver SBRT Dose Calculation

Purpose: To demonstrate and validate a technique for generating MRI-derived synthetic CT volumes (MRCTs) in support of adaptive liver SBRT. Methods: Under IRB approval, ten hepatocellular carcinoma patients were scanned using a single MR sequence (T1 Dixon-VIBE), yielding inherently-registered water, fat, and T1-weighted images. Air-containing voxels were identified by intensity thresholding. The envelope of the anterior vertebral bodies was segmented from the fat image by fitting a shape model to vertebral body candidate voxels, then using level sets to expand the contour outward. Fuzzy-C-Means (FCM) was then used to classify each non-air voxel in the image as fat, water, bone, or marrow. Bone and marrow only were classified within the vertebral body envelope. The MRCT was created by integrating the product of the FCM class probability with the assigned class density for each voxel. The resulting MRCTs were deformably aligned with planning CTs and 2-ARC SBRT VMAT plans were optimized on the MRCT density maps. Fluence was copied onto the CT density grids and dose recalculated. Results: The MRCTs faithfully reproduced most of the features visible in the corresponding CT image volumes, with exceptions of ribs and posterior spinous processes. The liver, vertebral bodies, kidneys, spleen and cord all had median HU differences of less than 75 between MRCT and CT images. PTV D99% values had an average 0.2% difference (standard deviation: 0.46%) between calculations on MRCT and CT density grids. The maximum difference in dose to 0.1cc of the PTV was 0.25% (std:0.49%). OAR dose differences were similarly small (mean:0.03Gy, std:0.26Gy). The largest normal tissue complication percentage (NTCP) difference was 1.48% (mean:0.06%, std:0.54%). Conclusions: MRCTs from a single abdominal imaging sequence are promising for use in SBRT dose calculation. Future work will focus on extending models to better define bones in the upper abdomen. Supported by NIHR01EB016079 and NIH1L30CA199594-01.

60 APPLIED LIFE SCIENCES↗

Going mobile to address emerging climate equity needs in the heterogeneous urban environment

We report the Brookhaven National Laboratory Center for Multiscale Applied Sensing (CMAS) aims to address environmental equity needs in the context of a changing climate. As a first step towards this goal, the center developed a one-of-a-kind observatory tailored to the study of highly heterogeneous urban environments. This article describes the features of the mobile observatory that enable its rapid deployment either on or off the power grid, as well as its instrument payload. Beyond its unique design, the observatory optimizes data collection within the obstacle-laden urban environment using a new smart sampling paradigm. This setup facilitated the collection of previously poorly documented environmental properties including wind profiles throughout the atmospheric column. The mobile observatory captured unique observations during its first few intensive observation periods (IOPs).. Vertical air motion and infrared temperature measurements collected along the faces of the supertall One Vanderbilt skyscraper in Manhattan, NY reveal how solar and anthropogenic heating affect wind flow and thus the venting of heat, pollution, and contaminants in urban street canyons. Also, air temperature measurements collected during travel along a 150-km transect between Upton and Manhattan, NY offer a high-resolution view of the urban heat island and reveal that temperature disparities also exist within the city across different neighborhoods. Ultimately, the datasets collected by CMAS are poised to help guide equitable urban planning by highlighting existing disparities and characterizing the impact of urban features on the urban microclimate with the goal of improving human comfort.

54 ENVIRONMENTAL SCIENCES↗

New Zealand Multi-Mode Technology Demonstration at the US Navy's Wave Energy Test Site

The objective of the project is to redeploy the Wave Energy Technology – New Zealand (WET-NZ and now known as Azura) device that was tested at the NNMREC test site in 2013 at the United States Navy’s Wave Energy Test Site (WETS). The goal is to conduct open-ocean, grid connected testing for a period of up to 12 months to 1) optimize energy capture and 2) validate LCOE model.

16 TIDAL AND WAVE POWER↗

The Atmospheric Grand Challenges in the Science of Wind Energy

Harvested by advanced technical systems honed over decades of research and development, wind energy has become a mainstream energy resource. However, continued innovation is needed to realize the potential of wind to serve the global demand for clean energy. Here, we outline three interdependent, cross-disciplinary grand challenges underpinning this research endeavor. The first is the need for a deeper understanding of the physics of atmospheric flow in the critical zone of plant operation. The second involves science and engineering of the largest dynamic, rotating machines in the world. The third encompasses optimization and control of fleets of wind plants working synergistically within the electricity grid. Addressing these challenges could enable wind power to provide as much as half of our global electricity needs and perhaps beyond.

17 WIND ENERGY↗

Distributed Coordination of Demand-side Flexible Resources in Microgrid with All-Time Feasibility

The prevalence of distributed renewable generators motivates microgrid operators to exploit demand-side flexible resources (DFRs). Due to their dispersed nature, distributed DFR coordination has been a vibrant research area, while there are several issues awaiting to be addressed. On one hand, DFR power is internally coupled through power flow, while DFR usually cannot access grid information. On the other hand, in time-restricted scenarios, solution feasibility cannot be guaranteed by conventional dual-based algorithms. To fill these gaps, we propose a distributed DFR coordination framework with all-time feasibility. The proposed framework accounts for the distinct access of microgrid entities to grid information. A distributed and all-time feasible algorithm is proposed for optimal DFR coordination, which allows DFRs to make local decisions without violating constraints throughout iterations. The effectiveness of the proposed algorithm is demonstrated through case studies. The impact of peer-to-peer communication links on algorithm convergence is also investigated, which emphasizes the balance between communication investment and algorithm performance.

Li, Hongyi [Iowa State Univ., Ames, IA (United Sta↗

Kokhanok Mini-grid Business Case

A business case analysis was performed for the Village of Kokhanok. The business case analysis evaluated the optimal case from the technical analysis performed by the National Renewable Energy. The optimal case provided for repairing the two Vestas 17 (90 kW) wind turbine controllers and added electric thermal stoves and a battery. The project cost 0.5 million. The direct cost of electricity would likely decline from 0.69/kWh to 0.39/kWh. The direct costs don’t include administrative and distribution costs. The repair of controller and the addition of electric stoves reduced fuel consumption by 63% or approximately 22,000 gallons. The reduction in cost provides an opportunity for the Kokhanok Village Council to obtain financing through grants and loans to install renewable energy and reduce diesel fuel consumption to the cooperative

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Shungnak Mini-grid Business Case

A business case analysis was performed for the Village of Shungnak. The business case analysis evaluated the optimal case from the technical analysis performed by the Sandia National Laboratory using Microgrid Design Toolkit (MDT). The optimal case adds a 500 kW wind plant, 100 kW of solar photovoltaics (PV), 100 kW diesel and 46 kW of electric thermal stoves. The project cost 4.3 million. The direct cost of electricity would likely decline from 0.63/kWh to 0.55/kWh. The direct costs don’t include administrative and distribution costs. The addition of the renewable resources reduced diesel fuel consumption by more than 74% or approximately 96,000 gallons. The reduction in cost provides an opportunity for Alaska Village Electric Cooperative to obtain financing through grants and loans to install renewable energy and reduce diesel fuel consumption to the cooperative.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Chefornak Mini-grid Business Case

A business case analysis was performed for the Village of Chefornak. The business case analysis evaluated the optimal case from the technical analysis performed by the National Renewable Energy using HOMER. The optimal case adds an 800 kW wind plant with 650 kW of electric thermal stoves and a 300 kW battery. The project cost 5.8 million. The direct cost of electricity would likely decline from 0.41/kWh to 0.30/kWh. The direct costs don’t include administrative and distribution costs. The addition of the renewable resources and thermal electric stoves reduced total fuel consumption by more almost 80% or approximately 103,000 gallons. The reduction in cost provides an opportunity for Chefornak’s utility, the Naterkaq Light Plant, to obtain financing through grants and loans to install renewable energy and reduce overall fuel consumption to the community.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Experimental Evidence on Latency in a Fleet of Controllable Water Heaters

Demand response is an important emerging part of smart grids with wide coverage in theoretical and modeling research. However, experimental evidence on the real-life behavior of controllable loads is still limited. We present observations regarding latency and communication aspects of the operation on a fleet of residential water heaters in a smart neighborhood in Atlanta, GA. Our analysis shows that latency in water heaters is not constant and does not follow a Gaussian distribution. We also find that there is a systematic relationship between latency and hour of the day. Latency was found to increase during morning and evening hours compared to the afternoon. These findings could help better plan deployment of control for demand response programs. Understanding delays associated with controlling smart devices is crucial for proper design and algorithm development for optimization, frequency of dispatch, and override detection.

communication delay↗

Battery and backup generator sizing for a resilient microgrid under stochastic extreme events

Owing to the recent power outages caused by extreme events, installing battery energy storage and backup generators is important to improve resiliency for a grid-tied microgrid. In the design stage, the event occurrence time and duration, which are highly uncertain and cannot be effectively predicted, may affect the needed battery and backup generator capacity but are usually assumed to be pre-determined in utility planning tools. This study investigates the optimal battery and backup generator sizing problem considering the stochastic event occurrence time and duration for the grid-tied microgrid under islanded operation. The reliability requirement is quantified by the mean value of the critical customer interruption time in each stochastic islanding time window (ITW), whose length is the duration and the centre is the occurrence time. The stochastic ITW constraint is then transformed to a probability-weighted expression to derive an equivalent Mixed Integer Linear Programming model. Numerical simulations on a realistic grid-tied PV-based microgrid demonstrate that the total cost is reduced by 11.5% considering the stochastic ITW, compared with the deterministic ITW under the same reliability requirement.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Emerging Technologies: Integrating with the Power Grid of Tomorrow

Traditional interactions between the built environment and the electric utility industry are changing rapidly. Rather than a one-way flow of electricity where utilities produce and transmit the electricity that buildings then consume, buildings are becoming efficient energy consumers that can dynamically adjust loads to ensure grid-provided energy is used effectively. Buildings are transitioning to now be at the intersection of forecasting loads and demand response, forecasting and control of output from distributed generation and renewable energy systems, and the optimal dispatch of energy storage. Because residential and commercial buildings consume 74.7% of the electricity generated in the United States, grid-integrated buildings represent an important solution to addressing challenges facing the power sector. In addition to the electric power grid, buildings will be increasingly interactive with water, transportation, and telecommunications networks, and will also more strongly affect surrounding buildings and other civic infrastructure.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Hawaii Meteorology, Energy and Transmission (MET) Toolkit

Reliable long-term resource adequacy and grid planning in Hawaii require precise, multi-decadal meteorological records. This paper introduces the Hawaii Meteorology, Energy and Transmission (MET) Toolkit, a 26-year (2000-2025) high-fidelity atmospheric dataset developed by the National Laboratory of the Rockies (NLR). We present a validation study of the underlying WRF model configurations, comparing the legacy MYNN PBL scheme against an alternative YSU formulation. Using vertical lidar profiles and surface buoy data, our analysis identified a foundational geometric distortion in the legacy NOW-23 Hawaii dataset caused by an incorrect grid projection. When evaluated on a corrected, zero-distortion grid, the YSU scheme demonstrated superior performance in bias and cRMSE compared to the legacy setup. To address these findings, the MET Toolkit has been re-produced as a unified 26-year record using the optimized YSU setup and corrected geometry. This dataset offers the Hawaii power sector a robust, validated, and homogenous reference for future grid resilience and energy integration.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Chefornak Energy Configuration Options: Energy Infrastructure Optimization to Reduce Fuel Cost and Dependence in Chefornak, Alaska

The U.S. Department of Energy is funding, through the Grid Modernization Program, the Alaska Microgrid Partnership (AMP), a multi-stakeholder collaborative comprised of national labs and Alaska based partners. The over-arching goal of AMP is to reduce the use of total imported fuel into communities to secure all energy services by at least 50% in Alaska's remote microgrids without increasing system lifecycle costs, while improving overall system reliability, security, and resilience. One goal of AMP is to investigate if a combination of Energy Efficiency (EE) and high contribution (from Renewable Energy (RE)) power systems can reduce total imported energy usage by 50% while lowering Life Cycle Costs (LCC) and improving reliability and resiliency. A techno-economic analysis was conducted for the community of Chefornak to investigate system architectures that could meet the goal of reducing imported fuel consumption by 50% or more.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A two-phase investment model for optimal allocation of phasor measurement units considering transmission switching

Ensuring the reliability of an electrical power system requires a wide-area monitoring and full observability of the state variables. Phasor measurement units (PMUs) collect in real time synchronized phasors of voltages and currents which are used for the observability of the power grid. Due to the considerable cost of installing PMUs, it is not possible to equip all buses with PMUs. In this paper, we propose an integer linear programming model to determine the optimal PMU placement plan in two investment phases. In the first phase, PMUs are installed to achieve full observability of the power grid whereas additional PMUs are installed in the second phase to guarantee the N - 1 observability of the power grid. The proposed model also accounts for transmission switching and single contingencies such as failure of a PMU or a transmission line. Results are provided on several IEEE test systems which show that our proposed approach is a promising enhancement to the methods available for the optimal placement of PMUs.

Phasor measurement unit↗

Gyrokinetic particle-in-cell optimization on emerging multi- and manycore platforms

The next decade of high-performance computing (HPC) systems will see a rapid evolution and divergence of multi- and manycore architectures as power and cooling constraints limit increases in microprocessor clock speeds. Understanding efficient optimization methodologies on diverse multicore designs in the context of demanding numerical methods is one of the greatest challenges faced today by the HPC community. In this paper, we examine the efficient multicore optimization of GTC, a petascale gyrokinetic toroidal fusion code for studying plasma microturbulence in tokamak devices. For GTC’s key computational components (charge deposition and particle push), we explore efficient parallelization strategies across a broad range of emerging multicore designs, including the recently-released Intel Nehalem-EX, the AMD Opteron Istanbul, and the highly multithreaded Sun UltraSparc T2+. We also present the first study on tuning gyrokinetic particle-in-cell (PIC) algorithms for graphics processors, using the NVIDIA C2050 (Fermi). Our work discusses several novel optimization approaches for gyrokinetic PIC, including mixed-precision computation, particle binning and decomposition strategies, grid replication, SIMDized atomic floating-point operations, and effective GPU texture memory utilization. Overall, we achieve significant performance improvements of 1.3–4.7× on these complex PIC kernels, despite the inherent challenges of data dependency and locality. Finally, our work also points to several architectural and programming features that could significantly enhance PIC performance and productivity on next-generation architectures.

97 MATHEMATICS AND COMPUTING↗

Enabling Resiliency Operations across Multiple Microgrids with Grid Friendly Appliance Controllers

Changes in economic, technological, and environmental policies are resulting in a re-evaluation of the dependence on large central generation facilities and their associated transmission networks. Emerging concepts of smart communities/cities are examining the potential to leverage cleaner sources of generation, as well as integrating electricity generation with other municipal functions. When grid connected, these generation assets can supplement the existing interconnections with the bulk transmission system, and in the event of an extreme event, they can provide power via a collection of microgrids. To achieve the highest level of resiliency, it may be necessary to conduct switching operations to interconnect individual microgrids. While the interconnection of multiple microgrids can increase the resiliency of the system, the associated switching operations can cause large transients in low inertia microgrids. The combination of low system inertia and IEEE 1547 and 1547a-compliant inverters can prevent multiple microgrids from being interconnected during extreme weather events. This study will present a method of using end-use loads equipped with Grid Friendly™ Appliance controllers to facilitate the switching operations between multiple microgrids; operations that are necessary for optimal operations when islanded for resiliency.

24 POWER TRANSMISSION AND DISTRIBUTION↗