Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid application”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Constraining the masses of high-redshift clusters with weak lensing: Revised shape calibration testing for the impact of stronger shears and increased blending

Weak lensing measurements suffer from well-known shear estimation biases, which can be partially corrected for with the use of image simulations. Here we present an analysis of simulated images that mimic Hubble Space Telescope/Advance Camera for Surveys observations of high-redshift galaxy clusters, including cluster specific issues such as non-weak shear and increased blending. Our synthetic galaxies have been generated to have similar observed properties as the background-selected source samples studied in the real images. First, we used simulations with galaxies placed on a grid to determine a revised signal-to-noise-dependent (S/N KSB ) correction for multiplicative shear measurement bias, and to quantify the sensitivity of our KSB+ bias calibration to mismatches of galaxy or PSF properties between the real data and the simulations. Next, we studied the impact of increased blending and light contamination from cluster and foreground galaxies, finding it to be negligible for high-redshift (z > 0.7) clusters, whereas shear measurements can be affected at the ~1% level for lower redshift clusters given their brighter member galaxies. Finally, we studied the impact of fainter neighbours and selection bias using a set of simulated images that mimic the positions and magnitudes of galaxies in Cosmic Assembly Near-IR Deep Extragalactic Legacy Survey (CANDELS) data, thereby including realistic clustering. While the initial SExtractor object detection causes a multiplicative shear selection bias of –0.028 ± 0.002, this is reduced to –0.016 ± 0.002 by further cuts applied in our pipeline. Given the limited depth of the CANDELS data, we compared our CANDELS-based estimate for the impact of faint neighbours on the multiplicative shear measurement bias to a grid-based analysis, to which we added clustered galaxies to even fainter magnitudes based on Hubble Ultra Deep Field data, yielding a refined estimate of ~ –0.013. Our sensitivity analysis suggests that our pipeline is calibrated to an accuracy of ~0.015 once all corrections are applied, which is fully sufficient for current and near-future weak lensing studies of high-redshift clusters. As an application, we used it for a refined analysis of three highly relaxed clusters from the South Pole Telescope Sunyaev-Zeldovich survey, where we now included measurements down to the cluster core (r > 200 kpc) as enabled by our work. Compared to previously employed scales (r > 500 kpc), this tightens the cluster mass constraints by a factor 1.38 on average.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of Prototypical District-Scale Models

The U.S. has set the climate goal to achieve net-zero greenhouse gas emissions by 2050. District-scale solutions, which include scale-specific opportunities for energy and emissions savings, can be investigated and implemented to help accelerate decarbonization and progress toward this goal. However, there is currently a lack of district-scale models of buildings and community energy systems that can be used to evaluate potential district-scale technologies and strategies across a range of representative community types. This initial work aims to define and develop prototype district models that can be adapted to support the planning, design, and operation of buildings and energy systems in districts considering the complexity and interactions of diverse building loads, weather impacts, distributed energy resources (e.g., PV, EV, electric and thermal energy storage), electric and thermal grid systems, and pricing signals. An overall workflow for developing these prototype district models is established. Stakeholders and potential users of the prototype district models provided technical feedback. The specifications of the selected high priority districts were defined and documented in a scorecard format. An example prototype district model was implemented with the URBANopt platform workflows. A case study was performed to demonstrate the model application.

building energy modeling↗

Development of Prototypical District-Scale Models: Preprint

The U.S. has set the climate goal to achieve net-zero greenhouse gas emissions by 2050. District-scale solutions, which include scale-specific opportunities for energy and emissions savings, can be investigated and implemented to help accelerate decarbonization and progress toward this goal. However, there is currently a lack of district-scale models of buildings and community energy systems that can be used to evaluate potential district-scale technologies and strategies across a range of representative community types. This initial work aims to define and develop prototype district models that can be adapted to support the planning, design, and operation of buildings and energy systems in districts considering the complexity and interactions of diverse building loads, weather impacts, distributed energy resources (e.g., PV, EV, electric and thermal energy storage), electric and thermal grid systems, and pricing signals. An overall workflow for developing these prototype district models is established. Stakeholders and potential users of the prototype district models provided technical feedback. The specifications of the selected high priority districts were defined and documented in a scorecard format. An example prototype district model was implemented with the URBANoptTM platform workflows. A case study was performed to demonstrate the model application.

district↗

Clean Energy Technology Applications on US Mine Land: Technical Analysis

As the United States transitions toward a clean energy economy, an opportunity exists for redeveloping the more than 17,000 mine land sites located across the nation with clean energy technologies, which have a combined potential for generating more than 85 GW of clean electricity. This report provides an overview of the potential of demonstrating and deploying clean energy projects on current and former mine land. Clean energy project refers to a project that demonstrates one or more of the following technologies: solar; microgrids; geothermal; direct air capture; fossil-fueled electricity generation with carbon capture, utilization, and sequestration; energy storage, including pumped storage hydropower and compressed air energy storage; and advanced nuclear technologies. The report discusses the following technologies and their potential for creating jobs and generating tax revenue that would result in direct and indirect benefits to the local economy: Solar photovoltaics (PV) is being developed on current and former mine land in various parts of the world, including the United States. This approach is attractive because it requires limited infrastructure investment and would utilize the bare surfaces of mines and tailing ponds. Solar resource availability may be greater in the southern regions, including the Interior and Appalachian Basins and the southwestern United States. However, since some mine land sites include areas of significant change in elevation, the deployment of PV on mine land may require sophisticated planning to account for shading and irradiance, or may require regrading of the areas. PV does not create significant environmental risks and generally does not face public resistance; Geothermal systems are often spatially and genetically associated with ore deposits, and in some cases, they have been discovered while in search for epithermal mineral resources. Numerous diverse geothermal applications have been employed at mine land around the world, including power generation, mineral extraction from geothermal brines, process heating, direct use for other mining operations, and direct use for non-mining operations and subsurface energy storage, including geothermal heat pumps. Case studies highlighting these applications provide key lessons relating to identifying drivers and barriers to geothermal resource deployment and can be used to create screening tools for identifying the types and locations of mine land most amenable to utilizing geothermal resources; Carbon capture, utilization, and sequestration technologies include direct air capture (DAC) and enhanced weathering. DAC technologies include air contactors, regeneration systems, and CO 2 compression systems. Captured CO 2 can be converted to valuable feedstocks or possibly injected into abandoned subsurface mines where it would be absorbed by alkaline rock waste and mine tailings or by the porous minerals along the walls of the mine. DAC systems can be coupled with energy sources such as wind, solar, grid, or geothermal. Many DAC systems require a source of water or steam; however, some are expected to be net producers of water. Local impacts of DAC systems are expected to be low, and are related to land footprint, material disposal, and upstream impacts of energy and material production; Compressed air energy storage is an established energy storage technology in salt caverns. It has the potential for implementation in underground mines by pressurizing and storing a large amount of air using electrical compressors when excess electricity is available. When a need for discharge emerges, the air is used to spin turbines and produce the necessary volume of electricity. Abandoned or unused mine openings, including shafts, adits, access tunnels, and mined workings of any orientation, offer potential for vast amounts of compressed air energy storage if the site characteristics meet operational requirements; Pumped hydropower storage can be implemented in surface and subsurface mines. In surface mine applications, both reservoirs may be located in a mine pit or artificial reservoirs made of excavated materials. In subsurface mines, the lower reservoir may be implemented by waterproofing and flooding mine shafts and tunnels. The water is then pumped from the lower reservoir to the upper reservoir during periods of low load and high production, and it is discharged through the turbines during periods of peak demand. The potential environmental damages associated with acidity of mine water or the presence of toxic chemicals incentivizes the development of closed-loop technologies, in which water circulates inside the pumped hydropower facility without being discharged into the external water basins; Advanced nuclear energy technologies include small modular reactors, which can be deployed locally to produce electricity and heat. Such units require seismic stability and a supply of cooling water, but population constraints may exist in some areas. Therefore, remote mine land could represent an optimal location for siting advanced nuclear energy technologies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Deployment of neural-network-based neutron microscopic cross sections in the Griffin reactor physics application

The capability to utilize neural networks to predict macroscopic and microscopic cross section parametric spaces has been developed for the Griffin reactor physics application. The LibTorch interface enables Griffin's MOOSE-based materials to interact with LibTorch-trained models, allowing for the evaluation of complex macroscopic or microscopic cross section spaces, which are then used to evaluate the neutronic properties of the Griffin finite element model. This study benchmarks traditional ISOXML-formatted tabulation libraries against neural network-based models for 279 nuclides on 20,160 grid points for zero-dimensional and two-dimensional reactor models. Benchmark metrics include the fundamental mode eigenvalue, fission and absorption rates, and various temperature coefficients of reactivity (isothermal, fuel, and moderator). From the perspective of storage space, the complete set of LibTorch models uses 11 MB on disk, compared to the 10 GB for the ISOXML multigroup library that covers the same grid space. For the two-dimensional performance case considered in Griffin, the Torch model uses 97% less RAM than the reference ISOXML dataset while runtime increases by a factor of 3 when using the LibTorch model compared to the ISOXML dataset with multi-linear interpolation. The LibTorch model consistently yields errors within 0.01% for most analyzed quantities except for the temperature coefficients of reactivity where the maximum discrepancies are up to 0.3 $\frac{pcm}{K}$. Due to the neural network attempting to best predict quantities with no regard for a positive or negative bias for any given quantity, predictions may experience random fluctuations, resulting in both positive and negative errors. Future work will entail both depletion and coupled transient analysis to determine the predictive capabilities of Griffin with neural network-based cross sections.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SIMPLE-G: A multiscale framework for integration of economic and biophysical determinants of sustainability

We introduce SIMPLE-G, a Simplified International Model of agricultural Prices, Land use, and the Environment- Gridded version, which is a novel tool for evaluating sustainability policies in a global context while factoring in local heterogeneity in land and water resources and natural ecosystem services. This multi-scale model can provide boundary conditions for local decision makers, as well as capturing feedback from local policies to national and global scales. Additionally, to illustrate its value in environmental analysis, we provide two applications of the model. First, we quantify the local stresses on land and water resources due to global changes in population, income, and productivity. Second, we quantify the global impacts of local policy responses and adaptations to water scarcity.

42 ENGINEERING↗

Evaluating Mesoscale Convective Systems Over the US in Conventional and Multiscale Modeling Framework Configurations of E3SMv1

Organized mesoscale convective systems (MCSs) contribute a significant amount of precipitation in the Central and Eastern US during spring and summer, which impacts the availability of freshwater and flooding events. However, current global Earth system models cannot capture MCSs well and misrepresent the statistics of precipitation in the region. In this study, we investigate the representation of MCSs in three configurations of the Energy Exascale Earth System Model (E3SMv1) by tracking individual storms based on outgoing longwave radiation using a new application of TempestExtremes. Our results indicate that conventional parameterizations of convection, implemented in both low (LR; ~150 km) and high (HR; ~25 km) resolution configurations, fail to capture almost all MCS-like events, in-part because they underestimate high-level cloud ice associated with deep convection. On the other hand, the multiscale modeling framework (MMF; cloud-resolving models embedded in each grid-column of ~150 km resolution E3SMv1) configuration represents MCSs and their annual cycle better. Nevertheless, relative to observations, the E3SMv1-MMF spatial distribution of MCSs and associated precipitation is shifted eastward, and the diurnal timing is lagged. A comparison between the large-scale environment in E3SMv1-MMF and ERA5 reanalysis suggests that the biases during the summer in E3SMv1-MMF are associated with biases in low-level humidity and meridional moisture transport within the low-level jet. The fact that conventional parameterizations of convection, even with high-resolution, cannot capture MCSs over the US suggests that methods with explicit representation of kilometer-scale convective organization, such as the MMF, may be necessary for improving the simulation of these convective systems.

54 ENVIRONMENTAL SCIENCES↗

Design and Evaluation of a Model-Free Frequency Control Strategy in Islanded Microgrids with Power-Hardware-in-the-Loop Testing

The deterioration of inertial and primary frequency response of islanded microgrids has been a crucial issue for the proper operation of such microgrids. Several approaches, including inertia emulation strategies, have been proposed to improve the primary frequency response. However, the demonstrations of most inertia emulation research works are based on simulation-only testing which hinder their applicability in the field. In this paper, a novel model-free control (MFC) strategy for frequency response support in a diesel-wind microgrid system is presented, and it is tested for evaluation using a power-hardware-in-the-Ioop (PHIL) platform. The PHIL testing is one step closer to field testing since it allows real-time verification and accounts for the nonlinear grid dynamics, noise, and time delays that are usually ignored in simulation-only environments. The proposed MFC strategy is fully distributed, has low computational requirements, and can be easily implemented in resource constrained devices such as smart inverters. A PHIL microgrid platform consisting of two type-3 wind turbine generators and one diesel generator is used to test the proposed MFC strategy.

Ferrari Maglia, Max↗

ReNCAT: The Resilient Node Cluster Analysis Tool

ReNCAT is a software application that suggests microgrid portfolios that reduce the impact of large-scale disruptions to power, as measured by the Social Burden Metric. ReNCAT examines a power distribution network to identify regions that can be isolated into microgrids that enable critical services to be provided even if the remainder of the study area is left without power. ReNCAT operates on a simplified representation of the power grid, one that aggregates and approximates loads and conductors. Microgrids are formed within the power network by setting switch states to split or join portions of the grid. ReNCAT identifies candidate microgrid portfolios with varying tradeoffs between cost and service availability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Upscaling Methods Applied to a Fine-Scale Reservoir Model

This study was conducted as part of the Southwest Regional Partnership on Carbon Sequestration (SWP) project to evaluate how upscaling fine-scale simulation models to coarse-scale simulation models impacted the results. The focus was on the Farnsworth Unit (FWU) and its Morrow' B' Sandstone reservoir, specifically the west half of the field. Due to data limitations and the geologic characteristics of the surrounding area, the upscaling was limited to the west half of the FWU rather than a broader basinscale model. The primary aim was to explore how upscaling impacts numerical simulation models, particularly regarding CO 2 -enhanced oil recovery (EOR) and storage capacity predictions. Upscaling was necessary to reduce computational demands when transitioning from high-resolution geological models to coarser grids, as large-scale simulations with finer grids can be computationally prohibitive. This study expands on previous work by the SWP to understand how additional upscaling, applied to already fine-scale numerical simulation models, affects reservoir performance simulations (Ampomah, Balch, & Grigg, 2015). This is key to understanding how loss of resolution can affect coarsescale model results that may be used for large sensitivity analyses, uncertainty quantifications, and training data for machine learning applications.

02 PETROLEUM↗

Development of Decay Heat Sensitivity Analysis Capability in SCALE/ORIGEN

In this work, a decay heat sensitivity analysis capability was developed and implemented in the ORIGEN code of the SCALE nuclear modeling and simulation suite. This capability introduces improved numerical integration schemes, which overcome the challenges associated with accurately modeling the behavior of adjoint nuclide amounts during coarse time steps for both nuclide amount and decay heat sensitivity calculations. This capability significantly improves the accuracy of calculations without compromising computational efficiency compared to the existing method. Extensive verification was conducted for various benchmark problems, including a 238 Pu decay and an irradiation problem involving 135 Xe, evaluated with both coarse and fine time grids. The results show excellent agreement with reference direct perturbation solutions, reaffirming the computational accuracy of the newly proposed numerical integration methods. Furthermore, sensitivity analyses were performed for fission product inventories ( 147 Sm, 150 Sm, 155 Gd) in pressurized water reactor UO 2 and MOX fuel assemblies. These analyses demonstrated that the ORIGEN sensitivity analysis capability can capture detailed sensitivity coefficients and underlying physics in real applications. Additionally, a decay heat sensitivity analysis for high-assay low-enriched uranium fuel, including various initial 235 U enrichment and burnup points, highlights the extended capabilities of SCALE/ORIGEN in comprehensively assessing the factors influencing total decay heat. These advancements in ORIGEN offer valuable insights for reactor analysis, fuel design, and safety assessments, especially in the context of advanced nuclear fuel development and design changes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

FLEXIBLE POWER TRANSFORMERS TO IMPROVE RESILIENCY OF TRANSMISSION NETWORKS

For decades, transformer flexibility of operation has been limited to adjustable voltage ratio and, in some cases, several ratings with staged cooling. Transformers reconnectable to multiple voltage ratings have been primarily applied as emergency replacements. Other versions of “flexible transformers” were developed for continuous, long-term operation at specific sites, with application limited to large utilities. A new technology that supports today’s power systems adaptability requirements has been developed to provide not only voltage and power rating flexibility, but also an adjustable short-circuit impedance. This last, unique feature allows for a closer match to actual system operational requirements and could be used in the future to enhance resiliency and improve dynamic control of electrical grids. While the solution’s fundamentals have already been introduced in several technical forums, the intention of this article is to focus on the potential benefits of this new type of transformer and share the deployment experience of a full-scale prototype that has been in operation in a major U.S. utility since 2021

flexible transformer, resilient grid, variable lea↗

An implicit, sharp numerical treatment of viscous terms at arbitrarily shaped liquid-gas interfaces in evaporative flows

We report a novel methodology for accurate treatment of viscous terms in evaporation problems. The proposed scheme is an extension of the sharp viscous treatment of Kang et al. (2000) [7] to 3D phase change problems. To ensure accuracy and grid converging solutions, a new implicit approach to computing viscous fluxes across the phase interfaces is proposed, which was previously unavailable in fixed grid numerical schemes. Analytical relations were derived for the jump in velocity gradients across the 2D and 3D phase interfaces, an important constituent of the proposed scheme. The relations show a non-vanishing jump in the tangential gradients across the phase interface that are associated with evaporative flux and interfacial curvature. The proposed methodology demonstrated first order accuracy in canonical test cases. It is general and applicable to arbitrarily oriented interfaces, and can be readily implemented in existing evaporation flow solvers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coarse grained simulation of convectively driven turbulent mixing, transition, and turbulence decay

Accurate predictions with quantifiable uncertainties are essential to many practical turbulent flow applications exhibiting extreme geometrical complexity and broad ranges of length and time scales. Under-resolved computer simulations are typically unavoidable in such applications, and implicit large-eddy simulation (ILES) often becomes the effective strategy. In this work, we focus on assessing ILES initialized with well-characterized 25 6 3 homogeneous isotropic turbulence datasets generated with direct numerical simulation (DNS). ILES solutions based on the LANL xRAGE code are studied as function of resolution for 6 4 3 , 12 8 3 , 25 6 3 , and 51 2 3 grids. ILES performance of new directionally-unsplit high-order numerical hydrodynamics algorithms in xRAGE is examined in this context. Compared to the initial 25 6 3 DNS, we find longer inertial subranges and higher turbulence Reynolds number (Re) for 25 6 3 and 51 2 3 xRAGE — attributed to having linked DNS (Navier–Stokes based) solutions to nominally inviscid (higher Re) Euler based ILES solutions. For fixed 25 6 3 resolution, we find that significantly larger simulated turbulence Re can be achieved with the higher-order unsplit (vs. split) discretizations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mesh and model requirements for capturing deep-stall aerodynamics in low-Mach-number flows

Here, this work presents a comprehensive computational fluid dynamics investigation of the effects of grid resolution and turbulence-model choice for capturing the unsteady three-dimensional aerodynamic performance of NACA 0012 and 0021 airfoils, with specific focus on the deep-stall regime. At high angles of attack (α), wind turbine blades routinely experience vortex-induced vibrations, which can cause significant structural damages. Accurate predictions of post-stall aerodynamics can identify the frequencies at which such vibrations maybe triggered. In this context, the NACA 0012 airfoil simulations are conducted at a chord-based Reynolds number, Re c =2×10 6 , with the k-ω Shear-Stress Transport Reynolds-Averaged Navier-Stokes (RANS) and Improved Delayed Detached Eddy Simulation (IDDES) hybrid RANS-Large Eddy Simulation turbulence models. The effect of mesh resolution both in the wall-normal and spanwise directions is investigated. Only the IDDES model with a minimum spanwise resolution of 24 cells per chord length correctly predicts the aerodynamic forces. Spectral analysis shows the peak primary shedding frequency at α=30°, which signifies the end of the stall region. In the post-stall regime, both lift and drag frequencies drop asymptotically with increasing α. The Strouhal number, based on normalised chord length, remains nearly constant in this region. Based on this study, NACA 0021 airfoil runs are performed with IDDES for Re c =2.7×10 5 and 2.0×10 6 on the finest wall-normal mesh and three spanwise grids. Simulations conducted on the finer spanwise grids demonstrate grid independence and show good agreement with experiments. The effect of varying Rec on the airfoil frequency statistics is investigated. Additionally, comparison studies are presented to investigate the impact of airfoil thickness on the frequency content at Re c =2.0×10 6 . The results from the study provide guidance on the choice of mesh resolution with the IDDES model to accurately capture aerodynamic quantities for complex industrial applications.

17 WIND ENERGY↗

Hierarchical Model-Free Transactive Control of Building Loads to Support Grid Services

Residential buildings consume 4.4 quads of electricity annually, approximately 37% of the total electricity consumption in the United States. This represents a vast resource that can be used for demand management and other ancillary services. This project aims to develop a robust, scalable hierarchical transactional control mechanism incorporating elements of model-free control (MFC) and game theory to harness buildings to provide ancillary services to the grid. This approach is being taken to address the challenges of incorporating traditional transactional control schemes into existing buildings. The challenges include small individual building sizes requiring aggregation of many buildings, unpredictable energy usage that makes model identification difficult, and satisfying the sensitive occupant comfort constraints. In the proposed approach, by separating the control mechanism into two layers above and below the load aggregator, MFC can be used below the aggregator to modulate flexible building loads in response to pricing signals with guaranteed performance. This allows the burden of identifying an accurate model of the system to be shifted to the above-aggregator layer, where fluctuations in individual building usage have less impact on predicted building system behavior. Game theory concepts can then be used to determine pricing curves and control signals among regional aggregators. Managing this control in a game-theoretic approach will allow us to build in financial incentives that increase customer engagement. Additionally, the usage of MFC necessitates less burdensome computational and communication requirements, thus, it is easily deployable on small, embedded devices. In a broader sense, developing a strategy capable of effectively incorporating residential and small commercial buildings will allow greater throughput of existing and emerging grid services in addition to future transactive energy grid management methods. Using MFC within a hierarchical control architecture will allow the shifting of existing forecasting challenges to an aggregate level, where dynamics are slower and more predictable. This will enable a smooth interface between the grid services requests of utilities and the reliable control required by participating buildings. MFC, which supports distributed control architecture, permits a scalable solution that can be deployed to neighborhood-size systems as well as individual buildings. This project focuses on three objectives: (1) developing the mathematical framework, algorithm toolkit, and software toolset of the two-layer transactive control testbed; (2) developing a scalable solution for application over many residential and small-size commercial buildings with sparse distributed communication; and (3) field testing and implementation on hardware of the control strategies developed in the previous two objectives. The research and development activities are focused and designed to be impactful within the relevant 2025 targets timeframe. An open-source control framework for exploiting variability and dispatchability of building loads will be delivered as the outcome of the project. This capability enables greater participation of loads in electricity markets and ancillary services that are both useful for the utility and financially beneficial for building owners.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗