Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “graphitization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Verification of computer-aided designs of traveling-wave tubes utilizing novel dynamic refocusers and graphite electrodes for the multistage depressed collector

A computational procedure for the design of TWT-refocuser-MDC systems was used to design a short dynamic refocusing system and highly efficient four-stage depressed collector for a 200-W, 8- to 18-GHz, TWT. The computations were carried out with advanced, multidimensional computer programs which model the electron beam as a series of disks of charge and follow their trajectories from the RF input of the TWT, through the slow-wave structure and refocusing section, to their points of impact in the depressed collector. Secondary emission losses in the MDC were treated semi-quantitatively by injecting a representative beam of secondary electrons into the MDC analysis at the point of impact of each primary beam. A comparison of computed and measured TWT and MDC performance showed very good agreement. The electrodes of the MDC were fabricated from a particular form of isotropic graphite that was selected for its low secondary electron yield, ease of machinability, and vacuum properties. This MDC was tested (at CW) for more than 1000 hr with negligible degradation in TWT and MDC performances.

Ramins, P.↗

Effects of high energy radiation on the mechanical properties of epoxy-graphite fiber reinforced composites

In an effort to elucidate the changes in molecular structural and mechanical properties of epoxy/graphite fiber composites upon exposure to ionizing radiation in a simulated space environment, spectroscopic and surface properties of tetraglycidyl-4,4'-diamino diphenyl methane (TGDDM) red with diamino diphenyl sulfone (DDS) and T-300 graphite fiber were investigated following exposure to ionizing radiation. Cobalt-60 gamma radiation and 1/2 MeV electrons were used as radiation sources. The system was studied using electron spin resonance (ESR) spectroscopy, infrared absorption spectroscopy, contact angle measurements, and electron spectroscopy for chemical analysis.

Fornes, R. E.↗

Fundamental Studies of Low Velocity Impact Resistance of Graphite Fiber Reinforced Polymer Matrix Composites

A study was conducted to relate the impact resistance of graphite fiber reinforced composites with matrix properties through gaining an understanding of the basic mechanics involved in the deformation and fracture process, and the effect of the polymer matrix structure on these mechanisms. It was found that the resin matrix structure influences the composite impact resistance in at least two ways. The integration of flexibilizers into the polymer chain structure tends to reduce the T sub g and the mechanical properties of the polymer. The reduction in the mechanical properties of the matrix does not enhance the composite impact resistance because it allows matrix controlled failure to initiate impact damage. It was found that when the instrumented dropweight impact tester is used as a means for assessing resin toughness, the resin toughness is enhanced by the ability of the clamped specimen to deflect enough to produce sufficient membrane action to support a significant amount of the load. The results of this study indicate that crossplied composite impact resistance is very much dependent on the matrix mechanical properties.

Bowles, K. J.↗

The correlation of low-velocity impact resistance of graphite-fiber-reinforced composites with matrix properties

Summarized are basic studies that were conducted to correlate the impact resistance of graphite-fiber-reinforced composites with polymer matrix properties. Three crosslinked epoxy resins and a linear polysulfone were selected as composite matrices. As a group, these resins possess a significantly large range of mechanical properties. The mechanical properties of the resins and their respective composites were measured. Neat resin specimens and unidirectional and crossply composite specimens were impact tested with an instrumented dropweight tester. Impact resistances of the specimens were assessed on the basis of loading capability, energy absorption, and extent of damage.

Bowles, K. J.↗

Residual thermal stresses in cross-ply graphite-epoxy tubes

Elasticity solutions for the residual stress state in cross-ply graphite-epoxy tubes subjected to a spatially uniform temperature below the cure temperature are derived. The solutions are valid away from the ends of the tube. Numerical results are presented for three tubes. It is seen that stacking arrangement can affect the residual stresses and that the radial stresses are smaller than the other stress components. The results show that classical lamination theory is in considerable error when the tube radius to wall thickness ratio is less than 20.

Hyer, M. W.↗

Space radiation effects on an elastomer-toughened epoxy-graphite composite

An elastomer-toughened epoxy-graphite composite system (CE339/T300) was evaluated for its potential durability in the space radiation environment. The physical and chemical response of this system was characterized following exposure to radiation doses equivalent to 20 to 30 years in geosynchronous orbit using 1 MeV electrons. The results show that electrons generate extensive crosslinking and embrittlement of the matrix. This embrittlement results in chemical and mechanical property changes that would limit the service life of this epoxy system in some space structure applications.

Sykes, G. F.↗

Moisture loss from graphite structures for the Hubble Space Telescope

The construction and telescope assembly of the NASA's Hubble Space Telescope (HST) is described with particular reference to the features of its construction material. Due to the hygroscopic nature of the graphite-fiber reinforced epoxy, used for much of the structure of the HST, the telescope, when in orbit, suffers losses of water, absorbed during on-ground procedures, accompanied by shrinkage of the epoxy matrix, and needs periodic realignment. Using a combination of analytic, laboratory measured, and in-space measured data, an operational plan for adjusting the alignment of the HST is presented. The refocusing plan must take into account the preceding ground environment, as well as the prelaunch, lift-off, and predeployment environments of the HST-bearing Space Shuttle.

Facey, T. A.↗

Hygrothermal effects on the mechanical behaviour of graphite fibre-reinforced epoxy laminates beyond initial failure

The critical load levels and associated cracking beyond which a multidirectional laminate can be considered as structurally failed has been determined by loading graphite fiber-reinforced epoxy laminates to different strain levels up to ultimate failure. Transverse matrix cracking was monitored by acoustic and optical methods. The residual stiffness and strength parallel and perpendicular to the cracks were determined and related to the environmental/loading history. Within the range of experimental conditions studied, it is concluded that the transverse cracking process does not have a crucial effect on the structural performance of multidirectional composite laminates.

Ishai, O.↗

Environmental stability of intercalated graphite fibers

Graphite fibers intercalated with bromine, iodine monochloride, ferric chloride, and cupric chloride were subjected to stability tests under four environments which are encountered by engineering materials in the aerospace industry: ambient laboratory conditions, as would be experienced during handling operations and terrestrial applications; high vacuum, as would be experienced in space applications; high humidity, as would be experienced in marine applications; and high temperature, as would be experienced in some processing steps and applications. Monitoring the resistance of the fibers at ambient laboratory conditions revealed that only the ferric chloride intercalated fibers were unstable, due to absorption of water from the air. All four types of intercalated fibers were unstable, due to absorption of water from the air. All four types of intercalated fibers were stable for long periods under high vacuum. Ferric chloride, cupric chloride, and iodine monochloride intercalated fibers were sensitive to high humidity conditions. All intercalated fibers began to degrade above 250 C. The order of their thermal stability, from lowest to highest, was cupric chloride, iodine monochloride, bromine, and ferric chloride. Of the four types of intercalated fibers tested, the bromine intercalated fibers appear to have the most potential for application, based on environmental stability.

Gaier, J. R.↗

Crack growth in unidirectional graphite-epoxy under biaxial loading

An anisotropic elasticity crack tip stress analysis is implemented using three crack extension direction criteria (the normal stress ratio, the tensor polynominal and the strain energy density) to predict the direction of crack extension in unidirectional of axis graphite-epoxy. The theoretical predictions of crack extension direction are then compared with experimental results for 15 deg off axis tensile coupons with center cracks. Specimens of various aspect ratios and crack orientations are analyzed. It is shown that only the normal stress ratio criterion predicts the correct direction of crack growth.

Beuth, J. L., Jr.↗

Tetraglycidyl epoxy resins and graphite fiber composites cured with flexibilized aromatic diamines

Studies were performed to synthesize new ether modified, flexibilized aromatic diamine hardeners for curing epoxy resins. The effect of moisture absorption on the glass transition temperatures of a tetraglycidyl epoxy, MY 720, cured with flexibilized hardeners and a conventional aromatic diamine was studied. Unidirectional composites, using epoxy-sized Celion 6000 graphite fiber as the reinforcement, were fabricated. The room temperature and 300 F mechanical properties of the composites, before and after moisture exposure, were determined. The Mode I interlaminar fracture toughness of the composites was characterized using a double cantilever beam technique to calculate the critical strain energy release rate.

Delvigs, P.↗

Postbuckling behavior of selected graphite-epoxy cylindrical panels loaded in axial compression

Results of an experimental and analytical study of the postbuckling behavior of selected graphite-epoxy cylindrical panels loaded in axial compression are presented. The postbuckling response and failure characteristics of the panels are described. The postbuckling response of each specimen is typical of axially-compressed cylindrical shells and curved panels in that a severe reduction in load occurs at buckling. Failure of all panels initiated near regions with severe local bending gradients. Analytical results from a nonlinear general shell finite element analysis computer code correlate well with typical experimental results up to buckling. Measured initial geometric imperfections were included in the postbuckling analysis. Analytically-determined stress distributions in the postbuckling response were used with failure criteria to identify the load level and the location of first-ply failure.

Knight, N. F., Jr.↗

Fractography of unidirectional graphite-epoxy as a function of moisture, temperature and specimen quality

Optical microscopy and SEM have been used to examine the tensile failure surfaces of (0-deg)8 T300/5208 graphite-epoxy specimens, and fractography is employed to determine how moisture content and temperature, together with specimen preparation, affect failure modes. A low energy failure morphology is noted in defective specimens; specimens made from nondefective prepregs appeared to exhibit a decrease in flaw sensitivity and increasing strength with either temperature or moisture, although moisture also seemed to increase interfacial debonding between filament and matrix. The combination of temperature and moisture degraded performance by increasing interfacial debonding, and rendering the epoxy more prone to fracture.

Clements, L. L.↗

Crack growth direction in unidirectional off-axis graphite-epoxy

An anisotropic elasticity crack tip stress analysis is implemented using three crack extension direction criteria (the normal stress ratio, the tensor polynominal and the strain energy density) to predict the direction of crack extension in unidirectional off axis graphite-epoxy. The theoretical predictions of crack extension direction are then compared with experimental results for 15 deg off axis tensile coupons with center cracks. Specimens of various aspect ratios and crack orientations are analyzed. It is shown that only the normal stress ratio criterion predicts the correct direction of crack growth.

Herakovich, C. T.↗

Thermally induced transverse cracking in graphite-epoxy cross-ply laminates

Thermally induced transverse cracking in T300/5208 graphite-epoxy cross-ply laminates was investigated experimentally and theoretically. The six laminate configurations studied were: 0/90(3)s, 0(2)/90(2)s, 0(3)/90s, 90/0(3)s, 90(2)/0(2)s, and 90(3)/0s. The thermal load required to initiate transverse cracking was determined experimentally and compared to a theoretical prediction. Experimental results for the accumulation of transverse cracks under cyclic thermal loading between - 250 and 250 F for up to 500 thermal cycles are presented. The calculated in situ transverse-lamina strength was determined to be at least 1.9 times the unidirectional-lamina transverse tensile strength. All laminate configurations exhibited an increase in crack density with increasing thermal cycles.

Adams, D. S.↗

Styrene-terminated polysulfone oligomers as matrix material for graphite reinforced composites: An initial study

Styrene terminated polysulfone oligomers are part of an oligomeric class of compounds with end groups capable of thermal polymerization. These materials can be used as matrices for graphite reinforced composites. The initial evaluation of styrene terminated polysulfone oligomer based composites are summarized in terms of fabrication methods, and mechanical and environmental properties. In addition, a description and evaluation is provided of the NASA/Industry Fellowship Program for Technology Transfer.

Garcia, Dana↗

Space environmental effects on graphite-epoxy compressive properties and epoxy tensile properties

This study characterizes the effects of electron radiation and temperature on a graphite-epoxy composite material. Compressive properties of the T300/934 material system were obtained at -250 F (-157 C), room temperature, and 250 F (121 C). Tensile specimens of the Fiberite 934 epoxy resin were fabricated and tested at room temperature and 250 F (121 C). Testing was conducted in the baseline (nonirradiated) and irradiated conditions. The radiation exposure was designed to simulate 30 year, worst-case exposure in geosynchronous Earth orbit. Mechanical properties tended to degrade at elevated temperature and improve at cryogenic temperature. Irradiation generally degraded properties at all temperatures.

Fox, Derek J.↗

Thermal stability of lightweight graphite glass sandwich reflectors for far infrared astronomy

Graphite fiber-reinforced glass matrix composites are being developed for a variety of structural applications requiring excellent thermomechanical stability. These materials are ideally suited for lightweight, high strength, thermally stable infrared mirrors because of their low density, low thermal expansion, high strength and stiffness, and their ability to be machined, replicated and figured using standard polishing techniques. These properties are particularly promising for applications such as a 3-meter balloon-borne far-infrared and submillimeter telescope mirror which must be both very lightweight and able to retain its figure accuracy when cycled between room temperature and its operating temperature of -50 C. This paper presents the results of a set of low temperature optical tests conducted to determine the figure stability of a 30-cm diameter, frit-bonded graphite/glass mirror in the +20 to -60 C temperature range using a 10.6 micron laser interferometer. The results indicate that the residual change in figure was less than 0.3 microns, rms.

Bluege, J. H.↗