Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flow testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Newberry Well 55-29 Stimulation Data 2014

The Newberry Volcano EGS Demonstration in central Oregon, a 5 year project begun in 2010, tests recent technological advances designed to reduce the cost of power generated by EGS in a hot, dry well (NWG 55-29) drilled in 2008. First, the stimulation pumps used were designed to run for weeks and deliver large volumes of water at moderate well-head pressure. Second, to stimulate multiple zones, AltaRock developed thermo-degradable zonal isolation materials (TZIMs) to seal off fractures in a geothermal well to stimulate secondary and tertiary fracture zones. The TZIMs degrade within weeks, resulting in an optimized injection/ production profile of the entire well. Third, the project followed a project-specific Induced Seismicity Mitigation Plan (ISMP) to evaluate, monitor for, and mitigate felt induced seismicity. An initial stimulation was conducted in 2012 and continued for 7 weeks, with over 41,000 m3 of water injected. Further analysis indicated a shallow casing leak and an unstable formation in the open hole. The well was repaired with a shallow casing tieback and perforated liner in the open hole and re-stimulated in 2014. The second stimulation started September 23rd, 2014 and continued for 3 weeks with over 9,500 m3 of water injected. The well was treated with several batches of newly tested TZIM diverter materials and a newly designed Diverter Injection Vessel Assembly (DIVA), which was the main modification to the original injection system design used in 2012. A second round of stimulation that included two perforation shots and additional batches of TZIM was conducted on November 11th, 2014 for 9 days with an additional 4,000 m3 of water injected. The stimulations resulted in a 3-4 fold increase in injectivity, and PTS data indicates partial blocking and creation of flow zones near the bottom of the well. This submission includes all of the files and reports associated with the stimulation, pressure testing, and monitoring included in the scope of the project.

15 GEOTHERMAL ENERGY↗

Dissipative particle dynamics simulations of deformation and aggregation of healthy and diseased red blood cells in a tube flow

In this paper, we report simulation results assessing the deformation and aggregation of mixed healthy and malaria-infected red blood cells (RBCs) in a tube flow. A three dimensional particle model based on Dissipative Particle Dynamics (DPD) is developed to predict the tube flow containing interacting cells. The cells are also modelled by DPD, with a Morse potential to characterize the cell-cell interaction. As validation tests, a single RBC in a tube flow and two RBCs in a static flow are simulated to examine the cell deformation and intercellular interaction, respectively. The study of two cells, one healthy and the other malaria-infected RBCs in a tube flow demonstrates that the malaria-infected RBC (in the leading position along flow direction) has different effects on the healthy RBC (in the trailing position) at the different stage of parasite development or at the different capillary number. With parasitic development, the malaria-infected RBC gradually loses its deformability, and in turn the corresponding trailing healthy RBC also deforms less due to the intercellular interaction. With increasing capillary number, both the healthy and malaria-infected RBCs are likely to undergo an axisymmetric motion. The minimum intercellular distance becomes small enough so that rouleaux is easily formed, i.e., the healthy and malaria-infected RBCs are difficultly disaggregated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Interfacial area transport and regime transition in combinatorial channels

This study investigates the geometric effects of 90-degree vertical elbows and flow configurations in two-phase flow. The study shows that the elbows make a significant effect on the transport characteristics of two-phase flow, which includes the changes in interfacial structures, bubble interaction mechanisms and flow regime transition. The effect of the elbows is characterized for global and local two-phase flow parameters. The global two-phase flow parameters include two-phase pressure, interfacial structures and flow regime transition. In order to characterize the frictional pressure drop and minor loss across the vertical elbows, pressure measurements are obtained across the test section over a wide range of flow conditions in both single-phase and two-phase flow conditions.

42 ENGINEERING↗

Vibration energy harvesting in a small channel fluid flow using piezoelectric transducer

This work is aimed at developing a way to harvest energy from a fluid stream with the application of piezoelectric transducers in a small channel. In this COMSOL Multiphysics based simulation study, it is attempted to harvest energy from the abundant renewable source of energy available in the form of kinetic energy of naturally occurring flow of fluids. The strategy involves harnessing energy from a fluid-actuator through generation of couples, eddies and vortices, resulting from the stagnation and separation of flow around a semi-circular bluff-body attached to a cantilever beam containing a piezoceramic layer. Fluctuation of fluidic pressure impulse on the beam due to vortex shedding and varying lift forces causes the flexible cantilever beam to oscillate in the direction normal to the fluid flow in a periodic manner. The periodic application and release of a mechanical strain upon the beam effected a generation of electric potential within the piezoelectric layer, thus enabling extraction of electrical energy from the kinetic energy of the fluid. The piezoelectric material properties and transducer design are kept unchanged throughout the study, whereas the configuration is tested with different fluids and varying flow characteristics. The size and geometry of the obstructing entity are systematically varied to closely inspect the output from different iterations and for finding the optimum design parameters. The intermittent changes in the generated forces and subsequent variation in the strain on the beam are also monitored to find definitive relationship with the electrical energy output.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Utilization of Wet Forest Biomass as both the Feedstock and Electricity Source for an Integrated Biochar Production System

Abstract. A belt dryer and gasifier generator set were integrated into a biochar production plant to use process heat to dry biomass feedstock from forest residuals and to provide electric power to the plant using a side stream of dried biomass. Experiments were conducted to characterize the dryer throughput and drying capacity using process heat from a stack heat exchanger attached to the biochar machine flare. A matrix of tests was conducted at high and low flow rates for both the heat exchanger air flow rate (which varied the temperature and heat input to the dryer) and the residence time of feedstock in the belt dryer. Mean feedstock input moisture during dryer characterization was 45% and the mean moisture after exiting the dryer was 27%. The optimal test condition, providing the greatest water removal rate, was determined to have high air flow rate through the heat exchanger and short dryer residence time. This condition was used to demonstrate the integrated system for an 8-h production day. The integrated system dried incoming feedstock from 36% to 22% with a dryer throughput rate of 495 kg h -1 w.b. and an evaporation rate of 88.8 kg h -1 , providing the necessary dry feedstock for the 20-kW gasifier generator set and the biochar machine, which produced 75 kg h -1 of biochar. This system required the operational effort of 0.92 labor hours per production hour. Results from this demonstration indicate that the integrated system provides key benefits in a biochar production operation including greater control of feedstock drying and the ability to operate without an external (non-biomass) source of fuel for electricity generation. Keywords: Biochar, Biomass, Biomass drying, Forest residuals, Gasification, Pyrolysis.

Agriculture↗

Passive Room-to-Room Air Transfer, Fresno, California (Fact Sheet)

Field testing was performed in a retrofit unoccupied test house in Fresno, California. Three air-based heating, ventilation, and air conditioning (HVAC) distribution systems - a typical airflow ducted system to the bedrooms, a low airflow ducted system to the bedrooms, and a system with no ductwork to the bedrooms - were evaluated during heating, cooling, and midseason conditions. The relative ability of each of the three systems was assessed with respect to relevant Air Conditioning Contractors of America (ACCA) and ASHRAE standards for house temperature uniformity and stability, respectively. Computational fluid dynamics (CFD) modeling also was performed and refined based on comparison to field test results to determine the air flow rate into the bedrooms of over-door and bottom-of-door air transfer grilles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Novel Membrane-Based Corrosion Sensors For Operating In Natural Gas Pipelines

Membrane-based electrochemical sensors (MBES) provide an attractive option for real-time continuous humidity and corrosion rate measurements inside of natural gas pipelines. The MBES, can use electrochemical techniques such as linear polarization resistance and electrochemical impedance spectroscopy even when a conductive aqueous phase is intermittent or unavailable. We now present field-test performance data of our MBES operated inside a multiphase water and natural gas flow facility. The MBES measured internal corrosion and conductivity at the top, bottom, and side of the pipe spool. Tests were carried out with flow rates of 4.6, 9.1, and 18.3 m/s, temperatures of 21, 29, and 35 °C, and a pressure of 1000 psia. All sensors followed similar trends in open circuit potential, corrosion rate, and conductivity over time. Neither flow rate, temperature, nor build-up of metal-based solids on the sensor surfaces impacted the quality of the electrochemical measurements. The field-test results confirm that the membrane-based electrochemical sensors are suitable for monitoring internal corrosion of operational natural-gas pipelines.

Duffy, Timothy↗

Pilot Scale Operation and Testing of Syngas Chemical Looping For Hydrogen Production

The Syngas Chemical looping (SCL) process provides efficient and economic means to utilize the abundant fossil reserve of coal. The main problem associated with coal utilization is the CO 2 emissions resulting from its combustion. Even though CO 2 regulation or carbon tax is currently not in place, its enforcement is expected in the near future. Such a greenhouse gas emission control, if adopted in current power plant systems, will drive the efficiency down and increase the cost of electricity, due to the energy and capital-intensive nature of current CO 2 separation techniques. This highlights the need to develop technologies that present a solution to the rising cost of electricity in the future. The integrated gasification combined cycle (IGCC) presents an improvement to the above predicament, but it is capital intensive due to the extensive unit operations involved. The efficiency for a CO 2 capture incorporated IGCC system is around ~32%, resulting in approximately 45% increase in cost of electricity. This is definitely a better path to traverse than the conventional pulverized coal (PC) power plants as it has improved economics and efficiencies accompanied by product flexibility. The SCL process advances the benefits even further when integrated with the IGCC process. The SCL process removes the expensive WGS system and CO 2 separation columns, thereby saving on capital and operational expenses. This integration results in a 12 – 21% increase in efficiency accompanied by a reduction in cost of electricity by 15 – 28%, over conventional IGCC systems. Therefore, SCL process provides the best route to harness the energy from coal. The overall project objective was to construct and operate a syngas chemical looping pilot scale test unit at the NCCC. The project scope of work was divided into 3 phases. In Phase I, cold flow model studies using a 1:1 scale acrylic test unit constructed at Particulate Solids Research, Inc. (PSRI) was successfully completed confirming robust solid flow control is achievable in the non-mechanical system design. In Phase II, the high pressure, high temperature, chemical looping reactor was successfully designed with all necessary equipment and safety instrumentation/controls specified to allow for fabrication, site construction, and assembly to commence in Phase III. In Phase III, the SCL pilot plant was successfully assembled and all necessary functional checks and pre-startup safety reviews completed. During unit commission over the course of 200 hours of testing, operational issues were observed with premix burner used for system startup. With the grants awarded by the National Energy Laboratory (NETL) and the Ohio Development Services Agency (ODSA) under awards DE-FE0023915 and D-14-18, the SCL pilot unit underwent three auxiliary equipment modifications to resolve all of the startup operational issues encountered. The unit was successfully demonstrated with 300+hr continuous operation. Key results obtained include high syngas conversion of 97.95% with 16.03% oxygen carrier conversion in the moving bed reducer and >99% purity H 2 produced from the moving bed oxidizer.

01 COAL, LIGNITE, AND PEAT↗

Cryogenic Fracturing of Wellbores Under True Triaxial-Confining Stresses: Experimental Investigation

A laboratory study of cryogenic fracturing was performed to test its ability to improve oil/gas recovery from low-permeability reservoirs. Our aim is to develop well-stimulation technologies using cryogenic fluids [e.g., liquid nitrogen (LN)] to increase permeability in a large reservoir volume surrounding wells. The new technology has the potential to reduce formation damage caused by current stimulation methods and minimize or eliminate water usage. The concept of cryogenic fracturing is that a sharp thermal gradient (thermal shock) created at the surfaces of formation rocks by applying cryogenic fluid can cause strong local tensile stress and start fractures. We created a laboratory system for cryogenic fracturing under true-triaxial loading, with LN-delivery/control and -measurement systems. The loading system simulates confining stresses by independently loading each axis up to approximately 5,000 psi on 888-in. cubes. Temperature in boreholes and at block surfaces and fluid pressure in boreholes were continuously monitored. Acoustic and pressure-decay measurements were obtained before and at various stages of stimulations. Cubic blocks (8 88-in.) of Niobrara shale, concrete, and sandstones were tested, and stress levels and anisotropies varied. Three schemes were considered: Gas fracturing without cryo-stimulation, gas fracturing after low-pressure cryogen flow-through, and gas fracturing after high-pressure cryogen flow-through. Findings from pressure-decay tests show that LN stimulation clearly increases permeability, and repeated stimulations further increase the permeability. Acoustic velocities and amplitudes decreased significantly after cryo-stimulation, indicating fracture creation. In the gas fracturing without the stimulation, breakdown (complete fracturing) occurs suddenly without any initial leaking, and major fracture planes form along the plane containing principal-stress and intermediate-stress directions, as expected theoretically. However, in the gas fracturing after cryogenic stimulations, breakdown occurred gradually and with massive leaking because of thermal fractures created during stimulation. In addition, the major fracture direction does not necessarily follow the plane containing the principal-stress direction, especially at low confining-stress levels. In tests, we observed that cryogenic stimulation seems to disrupt the internal stress field. The increase in borehole temperature after stimulation affects the permeability of the specimen. When a stimulated specimen is still cold, it maintains high permeability because fractures remain open and local thermal tension is maintained near the borehole. When the rock warms back, fractures close and permeability decreases. In these tests, we have not used proppants. Overall, fractures are clearly generated by low- and high-pressure thermal shocks. The added pressure of the high-pressure thermal shocks helps to further propagate cryogenic fractures generated by thermal shock. Breakdown pressure is significantly lowered by LN stimulation, with observed breakdown-pressure reductions up to approximately 40%.

42 ENGINEERING↗

Hot Deformation and Processing Maps of B{sub 4}C/6061Al Nanocomposites Fabricated by Spark Plasma Sintering

We developed 3 vol.% B{sub 4}C/6061Al nanocomposites by spark plasma sintering. We then characterized their flow and hot deformation behaviors using isothermal compression tests at deformation temperatures of 673-823 K and strain rates of 0.001-1 s{sup −1}. Results indicated that their steady flow characteristic can be described by the Zener–Hollomon parameter (Z) as a hyperbolic-sine function of flow stress. Based on pinning effect from B{sub 4}C nanoparticles, the estimated activation energy was calculated to be 274.80 kJ/mol. At the unstable deformation condition (723 K/1 s{sup −1}) with high Z, flow localization appeared; the main softening mechanisms involved are dynamic recovery and dynamic recrystallization (DRX). At the stable deformation condition (823 K/0.001 s{sup −1}) with low Z, adequate DRX occurred. Based on the processing map and microstructure evolution, the optimum hot working conditions for B{sub 4}C/6061Al nanocomposites were determined to be a deformation temperature of 773-823 K and a strain rate of 0.001-0.003 s{sup −1}. These working conditions were verified by a hot extrusion test.

36 MATERIALS SCIENCE↗

Simulating the Heterogeneity in Braided Channel Belt Deposits: Part 1. A Geometric-Based Methodology and Code

A geometric-based simulation methodology was developed and incorporated into a computer code to model the hierarchical stratal architecture, and the corresponding spatial distribution of permeability, in braided channel belt deposits. The code creates digital models of these deposits as a three-dimensional cubic lattice, which can be used directly in numerical aquifer or reservoir models for fluid flow. The digital models have stratal units defined from the km scale to the cm scale. These synthetic deposits are intended to be used as high-resolution base cases in various areas of computational research on multiscale flow and transport processes, including the testing of upscaling theories. The input parameters are primarily univariate statistics. These include the mean and variance for characteristic lengths of sedimentary unit types at each hierarchical level, and the mean and variance of log-permeability for unit types defined at only the lowest level (smallest scale) of the hierarchy. The code has been written for both serial and parallel execution. The methodology is described in Part 1 of this series. In Part 2, models generated by the code are presented and evaluated.

99 GENERAL AND MISCELLANEOUS↗

Simulation of confined magnetohydrodynamic flows with Dirichlet boundary conditions using a pseudo-spectral method with volume penalization

A volume penalization approach to simulate magnetohydrodynamic (MHD) flows in confined domains is presented. Here the incompressible visco-resistive MHD equations are solved using parallel pseudo-spectral solvers in Cartesian geometries. The volume penalization technique is an immersed boundary method which is characterized by a high flexibility for the geometry of the considered flow. In the present case, it allows to use other than periodic boundary conditions in a Fourier pseudo-spectral approach. The numerical method is validated and its convergence is assessed for two- and three-dimensional hydrodynamic (HD) and MHD flows, by comparing the numerical results with results from literature and analytical solutions. The test cases considered are two-dimensional Taylor–Couette flow, the z-pinch configuration, three dimensional Orszag–Tang flow, Ohmic-decay in a periodic cylinder, three-dimensional Taylor–Couette flow with and without axial magnetic field and three-dimensional Hartmann-instabilities in a cylinder with an imposed helical magnetic field. Finally, we present a magnetohydrodynamic flow simulation in toroidal geometry with non-symmetric cross section and imposing a helical magnetic field to illustrate the potential of the method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Extension and Demonstration of NEAMS Multiphysics Tools to Lead-Cooled, Sodium-Cooled, and Molten Salt Fast Reactor Applications

The SHARP toolkit is a high-fidelity reactor simulation tool developed under the U.S. Department of Energy, Office of Nuclear Energy Advanced Modeling and Simulation (NEAMS) Campaign. SHARP toolkit is comprised of the neutronics module PROTEUS thermal hydraulics module Nek5000, and structural mechanics module Diablo. During FY17 and FY18, the PROTEUS and Nek5000 components of SHARP were applied to solve challenging sodium-cooled fast reactor (SFR) problems. In particular, selected hot channel factors (HCF) for a prototype metal-fueled SFR design (the AFR-100) were analyzed in high fidelity, and the “SHARP zooming capability” for SFRs was developed and demonstrated to reduce computational expense for full core problems in cases where detailed data is needed in selected fuel assemblies. After the previous success applying SHARP to challenging SFR problems, the focus in FY19 expanded to additional fast reactor applications: lead cooled fast reactors (LFR), sodium cooled fast reactors (SFR), and fast molten salt reactors (MSR). The specific technical tasks were (1) assessment of hot channel factors for LFR, for which no data currently exists, (2) implementation of a gamma transport capability in the PROTEUS solvers to extend the zooming capability to non-fueled assemblies, (3) demonstration of zooming capability in assemblies of the Versatile Test Reactor (VTR), and (4) development of a new coupled capability for simulating fast MSRs, specifically modeling precursor transport inside and outside the core. The progress on tasks (1) and (3) are discussed primarily in this document. Tasks (2) and (4) are briefly mentioned in this document, and the interested reader is referred to separate reports for detailed information. First-of-a-kind hot channel factor (HCF) estimation for LFR with high fidelity codes (PROTEUS/Nek5000) was successfully demonstrated in this study. Selected HCF were computed and compared with SFR data (AFR-100, EBR-II). The findings confirm that different reactor types, design parameters and uncertainties lead to different HCFs. Careful estimation of HCF for a specific design is necessary to obtain appropriate HCFs. In addition to improvement in HCF accuracy, high fidelity tools generate data to help the designer better understand the mechanism of the impact from these uncertainties. For example, the impact of cladding thickness manufacturing tolerance resulted in non-intuitive effects in the corner pins of the LFR assembly. This procedure of computing HCF using high fidelity models shows promise and flexibility for being repeated for any arbitrary reactor of choice, since these tools are targeted to solve many reactor types and geometries. Progress was made towards extending the previously demonstrated SHARP zooming capability to non-fueled SFR assemblies. In particular, a gamma transport capability was implemented in both high fidelity PROTEUS solvers in order to accurately account for heat deposition caused by gamma particles, which accounts for ~10% of total core power. Neutronics verification cases were carried out for a candidate Versatile Test Reactor (VTR) design using the new gamma transport capability in PROTEUS. Comparisons were made with continuous energy MCNP calculations and shown to agree well. The models for the full core design with heterogeneous control and fuel assemblies is in progress and will be completed in FY20. In the fast molten salt reactor (MSR) domain, a new capability was developed to model the flow of neutron precursors both inside and outside of the core, which impacts the effective delayed neutron fraction of the system. The PROTEUS-SN and PROTEUS-NODAL solvers were coupled to Nek5000 in order to simulate precursor flow. The workflows were demonstrated on test problems. The fast MSR modeling capability was supported under two other work packages, and comprehensive details are included in a separate report.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Recover Act. Verification of Geothermal Tracer Methods in Highly Constrained Field Experiments

The prediction of the geothermal system efficiency is strong linked to the character of the flow system that connects injector and producer wells. If water flow develops channels or “short circuiting” between injection and extraction wells thermal sweep is poor and much of the reservoir is left untapped. The purpose of this project was to understand how channelized flow develops in fracture geothermal reservoirs and how it can be measured in the field. We explored two methods of assessing channelization: hydraulic connectivity tests and tracer tests. These methods were tested at a field site using two verification methods: ground penetrating radar (GPR) images of saline tracer and heat transfer measurements using distributed temperature sensing (DTS). The field site for these studies was the Altona Flat Fractured Rock Research Site located in northeastern New York State. Altona Flat Rock is an experimental site considered a geologic analog for some geothermal reservoirs given its low matrix porosity. Because soil overburden is thin, it provided unique access to saturated bedrock fractures and the ability image using GPR which does not effectively penetrate most soils. Five boreholes were drilled in a “five spot” pattern covering 100 m2 and hydraulically isolated in a single bedding plane fracture. This simple system allowed a complete characterization of the fracture. Nine small diameter boreholes were drilled from the surface to just above the fracture to allow the measurement of heat transfer between the fracture and the rock matrix. The focus of the hydraulic investigation was periodic hydraulic testing. In such tests, rather than pumping or injection in a well at a constant rate, flow is varied to produce an oscillating pressure signal. This pressure signal is sensed in other wells and the attenuation and phase lag between the source and receptor is an indication of hydraulic connection. We found that these tests were much more effective than constant pumping tests in identifying a poorly connected well. As a result, we were able to predict which well pairs would demonstrate channelized flow. The focus of the tracer investigation was multi-ionic tests. In multi-ionic tests several ionic tracers are injected simultaneously and the detected in a nearby pumping well. The time history of concentration, or breakthrough curve, will show a separation of the tracers. Anionic tracers travel with the water but cationic tracer undergo chemical exchange with cations on the surface of the rock. The degree of separation is indicative of the surface area exposed to the tracer. Consequently, flow channelization will tend to decrease the separation in the breakthrough. Estimation of specific surface area (the ration of fracture surface area to formation volume) is performed through matching the breakthrough curve with a transport model. We found that the tracer estimates of surface area were confirmed the prediction of channelized flow between well pairs produced by the periodic hydraulic tests. To confirm that the hydraulic and tracer tests were correctly predicting channelize flow, we imaged the flow field using surface GPR. Saline water was injected between the well pairs which produced a change in the amplitude and phase of the reflected radar signal. A map was produced of the migration of saline tracer from these tests which qualitatively confirmed the flow channelization predicted by the hydraulic and tracer tests. The resolution of the GPR was insufficient to quantitatively estimate swept surface area, however. Surface GPR is not applicable in typical geothermal fields because the penetration depths do not exceed 10’s of meters. Nevertheless, the method of using of phase to measure electrical conductivity and the assessment of antennae polarization represent a significant advancement in the field of surface GPR. The effect of flow character on fracture / rock thermal exchange was evaluated using heated water as a tracer. Water elevated 30 degrees C above the formation water was circulated between two wells pairs. One well pair had been identified in hydraulic and tracer testing as well connected and the other poorly connected. Temperature rise was measured in the adjacent rock matrix using coiled fiber optic cable interrogated for temperature using a DTS. This experimental design produced over 4000 temperature measurements every hour. We found that heat transfer between the fracture and the rock matrix was highly impacted by the character of the flow field. The strongly connected wells which had demonstrated flow channelization produced heat rise in a much more limited area than the more poorly connected wells. In addition, the heat increase followed the natural permeability of the fracture rather than the induced flow field. The primary findings of this work are (1) even in a single relatively planar fracture, the flow field can be highly heterogeneous and exhibit flow channeling, (2) channeling results from a combination of fracture permeability structure and the induced flow field, and (3) flow channeling leads to reduced heat transfer. Multi-ionic tracers effectively estimate relative surface area but an estimate of ion-exchange coefficients are necessary to provide an absolute measure of specific surface area. Periodic hydraulic tests also proved a relative indicator of connectivity but cannot prove an absolute measure of specific surface area.

15 GEOTHERMAL ENERGY↗

Identification of an advanced constitutive model of Magnesium alloy AZ31B

The main aim of this paper is to study the flow behavior of the AZ31B magnesium alloy by means of tensile tests performed in extended ranges of temperature and strain rates. The flow stress-strain curves analyzed by power law type constitutive equation can only fit well with experimental curves at the work-hardening stage. A new mathematical model is studied to describe the softening behavior of material based on tensile experiments. The relative parameters are obtained by fitting the equation with the experimental data. The genetic algorithm has been used to obtain the global optimal fitting parameters. The comparison between the fitted and experimental data proves the effectiveness of the model. The results indicate that this model leads to a better simulation of the flow stress during the softening stage than that of the power law equation. Based on this model, the deep drawing process has been simulated with the commercial finite element code FORGE registered. The punch load and thickness distribution of AZ31 sheet have been studied. The study of the results is helpful to the application of the stamping technology for the magnesium alloy sheet.

36 MATERIALS SCIENCE↗

Simplified Space Conditioning in Low-Load Homes: Results from the Fresno, California, Retrofit Unoccupied Test House

In this study, the Building America team, IBACOS, sought to determine cost-effective, energy-efficient solutions for heating and cooling houses. To this end, the team performed field testing in a retrofit unoccupied test house in Fresno, California, to evaluate three air-based heating, ventilation, and air conditioning (HVAC) distribution systems during heating, cooling, and midseason conditions. These included a typical airflow ducted system to the bedrooms, a low airflow ducted system to the bedrooms, and a system with no ductwork to the bedrooms. The relative ability of each of the three systems was assessed with respect to relevant Air Conditioning Contractors of America (ACCA) and ASHRAE standards for house temperature uniformity and stability, respectively. Computational fluid dynamics modeling also was performed and refined based on comparison to field test results to determine the air flow rate into the bedrooms of over-door and bottom-of-door air transfer grilles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fish Response to Turbulence Generated Using Multiple Randomly Actuated Synthetic Jet Arrays

Hydroelectric power stations generate turbulent flow conditions, which represent a potentially significant hydraulic stressor to fish passing through the turbine system. A test facility has been developed using two randomly actuated synthetic jet arrays (RASJAs) of 25 independent submersible pumps to generate a turbulent flow field for biological dose-response testing. The novel elements of this approach include the ability to control the exposure duration within a test volume due to low mean flow velocity as well as the capacity to scale the turbulence levels as a function of pump capacity. Juvenile Chinook salmon (Oncorhynchus tshawytscha) were subjected to the turbulent flow regime with average turbulence kinetic energy per unit mass of 0.089 m 2 /s 2 for periods of 2 min and 10 min. No significant loss of equilibrium or disorientation was observed after exposure for either duration at the level of turbulence achieved in this prototype. Further scaling of this approach is required to generate a complete dose-response relationship.

59 BASIC BIOLOGICAL SCIENCES↗

Bubble confinement in flow boiling of FC-72 in a ''rectangular'' microchannel of high aspect ratio

Boiling in microchannels remains elusive due to the lack of full understanding of the mechanisms involved. A powerful tool in achieving better comprehension of the mechanisms is detailed imaging and analysis of the two-phase flow at a fundamental level. Boiling is induced in a single microchannel geometry (hydraulic diameter 727 {mu}m), using a refrigerant FC-72, to investigate the effect of channel confinement on bubble growth. A transparent, metallic, conductive deposit has been developed on the exterior of the rectangular microchannel, allowing simultaneous uniform heating and visualisation to be achieved. The data presented in this paper is for a particular case with a uniform heat flux applied to the microchannel and inlet liquid mass flowrate held constant. In conjunction with obtaining high-speed images and videos, sensitive pressure sensors are used to record the pressure drop across the microchannel over time. Bubble nucleation and growth, as well as periodic slug flow, are observed in the microchannel test section. The periodic pressure fluctuations evidenced across the microchannel are caused by the bubble dynamics and instances of vapour blockage during confined bubble growth in the channel. The variation of the aspect ratio and the interface velocities of the growing vapour slug over time, are all observed and analysed. We follow visually the nucleation and subsequent both 'free' and 'confined' growth of a vapour bubble during flow boiling of FC-72 in a microchannel, from analysis of our results, images and video sequences with the corresponding pressure data obtained. (author)

42 ENGINEERING↗