Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flash”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Preemptible I/O Scheduling of Garbage Collection for Solid State Drives

Unlike hard disks, flash devices use out-of-place updates operations and require a garbage collection (GC) process to reclaim invalid pages to create free blocks. This GC process is a major cause of performance degradation when running concurrently with other I/O operations as internal bandwidth is consumed to reclaim these invalid pages. The invocation of the GC process is generally governed by a low watermark on free blocks and other internal device metrics that different workloads meet at different intervals. This results in an I/O performance that is highly dependent on workload characteristics. In this paper, we examine the GC process and propose a semipreemptible GC (PGC) scheme that allows GC processing to be preempted while pending I/O requests in the queue are serviced. Moreover, we further enhance flash performance by pipelining internal GC operations and merge them with pending I/O requests whenever possible. Our experimental evaluation of this semi-PGC scheme with realistic workloads demonstrates both improved performance and reduced performance variability. Write-dominant workloads show up to a 66.56% improvement in average response time with a 83.30% reduced variance in response time compared to the non-PGC scheme. In addition, we explore opportunities of a new NAND flash device that supports suspend/resume commands for read, write, and erase operations for fully PGC (F-PGC). Our experiments with an F-PGC enabled flash device show that request response time can be improved by up to 14.57% compared to semi-PGC.

97 MATHEMATICS AND COMPUTING↗

The Role of Interfacial Thermal Resistance in Li-Ion Battery Thermal Management: Preprint

Temperature critically affects the performance, life and safety of lithium-ion batteries. Therefore, it is essential to understand heat generation and dissipation within individual battery cells and battery packs to plan a proper thermal management strategy. One of the key challenges is that interfacial heat transfer of a battery unit is difficult to quantify. The steady-state absolute method and the transient laser-flash-diffusivity method were employed to measure heat conductivities of battery layer stacks and individual battery layer separately. Results show flash diffusivity method gives higher thermal conductivity at both cross-plane and in-plane directions. The difference is primarily caused by interfacial thermal resistance so that it can be estimated by steady-state and transient measurements. To investigate the effects of interfacial thermal transport beyond individual cell level, a multiphysics battery model is used. The model is built upon a multi-scale multi-domain modeling framework for battery packs that accounts for the interplay across multiple physical phenomena. Benefits of a battery module using thermal management materials are quantified through numerical experiments. During a thermal runaway event, it is found interfacial thermal resistance can mitigate thermal runaway in a battery module by significantly reducing heat transfer between cells.

33 ADVANCED PROPULSION SYSTEMS↗

SU-E-J-273: Skin Temperature Recovery Rate as a Potential Predictor for Radiation-Induced Skin Reactions

Purpose: To assess the potential of dynamic infrared imaging to evaluate early skin reactions during radiation therapy in cancer patients. Methods: Thermal images were captured by our home-built system consisting of two flash lamps and an infrared (IR) camera. The surface temperature of the skin was first raised by ∼ 6 °C from ∼1 ms short flashes; the camera then captured a series of IR images for 10 seconds. For each image series, a basal temperature was recorded for 0.5 seconds before flash was triggered. The temperature gradients (ε) were calculated between a reference point (immediately after the flash) and at a time point of 2sec, 4sec and 9sec after that. A 1.0 cm region of interest (ROI) on the skin was drawn; the mean and standard deviations of the ROIs were calculated. The standard ε values for normal human skins were evaluated by imaging 3 healthy subjects with different skin colors. All of them were imaged on 3 separate days for consistency checks. Results: The temperature gradient, which is the temperature recovery rate, depends on the thermal properties of underlying tissue, i.e. thermal conductivity. The average ε for three volunteers averaged over 3 measurements were 0.64±0.1, 0.72±0.2 and 0.80±0.3 at 2sec, 4sec and 9sec respectively. The standard deviations were within 1.5%–3.2%. One of the volunteers had a prior small skin burn on the left wrist and the ε values for the burned site were around 9% (at 4sec) and 13% (at 9sec) lower than that from the nearby normal skin. Conclusion: The temperature gradients from the healthy subjects were reproducible within 1.5%–3.2 % and that from a burned skin showed a significant difference (9%–13%) from the normal skin. We have an IRB approved protocol to image head and neck patients scheduled for radiation therapy.

60 APPLIED LIFE SCIENCES↗

Global Technogenic Day- and Nightglows Detected onboard the Vernov Satellite in the Ultraviolet and Infrared Optical Spectral Ranges

The generation of transient and other optical phenomena in the Earth’s upper atmosphere under the action of electron fluxes and high- and low-frequency electromagnetic waves resulting from electromagnetic fields [1] has been studied onboard the small Vernov spacecraft (solar synchronous orbit, 98° inclination, altitude 640–830 km). On the night side at middle latitudes, the technogenic glow is shown to be observed along the preferential meridians whose distribution corresponds to the longitudes of the most powerful low-frequency radio stations [2]. The geographic distribution of this glow changes abruptly at the boundary between the day and night sides of the satellite orbit; on the day side, such meridians are not identified, while their geographic distribution in longitude is uniform. The boundaries of the geographic distribution of technogenic glow regions on the day side are unstable in latitude, their northern and southern boundaries are shifted at all latitudes from the North Pole to the South Pole. At middle and low latitudes, zones with random geographic coordinates, where the technogenic glow is completely absent, are observed in the distributions of signals along the meridians. When studying the flashes caused by discharges in the atmosphere, we showed that lightning flashes and transient luminous events at nighttime are observed mainly in equatorial regions, which coincide with zones of high thunderstorm activity. At daytime, flashes of light are recorded much more rarely, have a short duration, are observed most often in the Earth’s polar regions, including the winter periods, the power of their emission exceeds considerably the power of similar (in duration) short flashes observed at night.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Geothermal Power Production: Alternative Scenarios and Critical Issues

This is the last in a series of reports that completes the life cycle analyses (LCAs) of geothermal power production technologies conducted by Argonne National Laboratory. It addresses the remaining critical issues pertaining to the LCAs of geothermal electricity production: the relative contributions from plant operations and maintenance (O&M), from decommissioning (dcm), from well field exploration, and from plant operational greenhouse gas (GHG) emissions to the total life cycle performance of geothermal power plants. Contributions from O&M and dcm to the performance of other power generating technologies are also discussed. Also included in this study are LCA results for a new series of scenarios for geothermal power production. Our analysis uses fossil fuel energy consumption and GHG emissions per unit of lifetime electricity output (referred to as the fossil energy and GHG ratios, respectively) as the life cycle metrics for quantifying life cycle stage contributions to their corresponding totals, which were subsequently used for comparing the environmental performance of geothermal and other electric power production plants. Based on literature results, we concluded that the contribution from dcm to both ratios is negligible for power plants in general. Further, we found that the contribution from O&M to both ratios is generally significant for facilities with no fuel cycle (fuel production and use) burdens. In the case of geothermal power production, O&M contributes about 20% to the total for enhanced geothermal power plants, 10% for geothermal binary plants, and about 25% of the energy ratio for geothermal flash and dry steam plants. However, due to operational GHG emissions that are unique among geothermal power plants, O&M contributes only about 1% of total GHG ratios for flash and dry steam plants. These GHG emissions arise when the geofluids of these plants become exposed to the atmosphere, thus releasing dissolved GHGs. The amount of GHG emissions from these plants had a wide range. However, we found that 85% of California’s running capacity in flash and dry steam plants released 160 grams or less per kilowatt-hour of electricity produced. We developed an exploration model to account for core hole, slim hole, and confirmation well drilling that includes a probability of success for confirmation well drilling. The model shows that well field exploration represents about 20% of the total life cycle burden for large geothermal plants with numerous wells and 32% of the burden for small plants with few wells. We also analyzed a set of geothermal scenario pairs. The objective was to identify geothermal scenarios with a lower levelized cost of electricity and lower life cycle burdens. A comparison of reference with improved cases within each pair revealed that the improved cases demonstrated a lower levelized cost of electricity and lower fossil energy consumption and GHG metrics. The scenario pairs covered a range of plant capacities, well numbers and depths, resource temperatures, and plant lifetimes. Finally, we found that compared to fossil-fuel generation of electricity, both flash and dry steam geothermal electricity generation result in fewer GHG emissions: on average, only one-fifth of the GHG emissions per kilowatt-hour from a natural gas combined-cycle plant, and one-tenth of those from a coal-fired plant. Moreover, these fractions were much smaller when the fossil plants were compared with plants that use geothermal binary technology.

Sullivan, J. L.↗

Models for Total-Dose Radiation Effects in Non-Volatile Memory

The objective of this work is to develop models to predict radiation effects in non- volatile memory: flash memory and ferroelectric RAM. In flash memory experiments have found that the internal high-voltage generators (charge pumps) are the most sensitive to radiation damage. Models are presented for radiation effects in charge pumps that demonstrate the experimental results. Floating gate models are developed for the memory cell in two types of flash memory devices by Intel and Samsung. These models utilize Fowler-Nordheim tunneling and hot electron injection to charge and erase the floating gate. Erase times are calculated from the models and compared with experimental results for different radiation doses. FRAM is less sensitive to radiation than flash memory, but measurements show that above 100 Krad FRAM suffers from a large increase in leakage current. A model for this effect is developed which compares closely with the measurements.

97 MATHEMATICS AND COMPUTING↗

In-Situ Measurement of Power Loss for Crystalline Silicon Modules Undergoing Thermal Cycling and Mechanical Loading Stress Testing

An in-situ method is proposed for monitoring and estimating the power degradation of mc-Si photovoltaic (PV) modules undergoing thermo-mechanical degradation tests that primarily manifest through cell cracking, such as mechanical load tests, thermal cycling and humidity freeze tests. The method is based on in-situ measurement of the module’s dark current-voltage (I-V) characteristic curve during the stress test, as well as initial and final module flash testing on a Sun simulator. The method uses superposition of the dark I-V curve with final flash test module short-circuit current to account for shunt and junction recombination losses, as well as series resistance estimation from the in-situ measured dark I-Vs and final flash test measurements. The method is developed based on mc-Si standard modules undergoing several stages of thermo-mechanical stress testing and degradation, for which we investigate the impact of the degradation on the modules light I-V curve parameters, and equivalent solar cell model parameters. Experimental validation of the method on the modules tested shows good agreement between the in-situ estimated power degradation and the flash test measured power loss of the modules, of up to 4.31 % error (RMSE), as the modules experience primarily junction defect recombination and increased series resistance losses. However, the application of the method will be limited for modules experiencing extensive photo-current degradation or delamination, which are not well reflected in the dark I-V characteristic of the PV module.

14 SOLAR ENERGY↗

Conspicuity of target lights: The influence of color

The conspicuity (or attention-getting qualities) were investigated of foveally-equated, colored lights, when seen against a star background. Subjects who were periodically engaged in a distracting cockpit task were required to search a large visual field and report the appearance of a target light as quickly as possible. Targets were red, yellow, white, green, and blue, and appeared either as steady or as flashing lights. Results indicate that red targets were missed more frequently and responded to more slowly than lights of other hues. Yellow targets were acquired more slowly than white, green, or blue targets; responses to white targets were significantly slower than responses to green or blue targets. In general, flashing lights were superior to steady lights, but this was not found for all hues. For red, the 2 Hz flash was superior to all other flash rates and to the steady light, none of which differed significantly from each other. Over all hues, conspicuity was found to peak at 2-3 Hz. Response time was found to be fastest, generally, for targets appearing at between 3 and 8 from the center of the visual field. However, this pattern was not repeated for every hue. Conspicuity response times suggest a complex relationship between hue and position in the visual field that is explained only partially by retinal sensitivity.

Connors, M. M.↗

Non-thermal processes during the 'build-up' phase of solar flares and in absence of flares

Hard X-ray and radio observations indicate production of non-thermal electrons as a common phenomenon of the active sun. A preliminary analysis of three hard X-ray bursts observed with the OGO-5 satellite and radio observations indicate that non-thermal particles are present in the flare region prior to the impulsive (flash) phase and also during the gradual rise and fall (GRF) bursts which are usually explained in terms of purely 'thermal' radiation. The principal difference between the non-thermal electrons observed before the flash phase and during the flash phase appears to be in their total number rather than in the hardness of their energy spectrum. Basic characteristics of the two acceleration processes are probably similar although the total energy converted into non-thermal electrons is considerably larger in the flash phase. Transient absorbing H-alpha features and filament activations are discussed in terms of their ability to produce energetic particle events and magnetic energy release.

Kane, S. R.↗

RF radiation from lightning

Radiation from lightning in the RF band from 3-300 MHz were monitored. Radiation in this frequency range is of interest as a potential vehicle for monitoring severe storms and for studying the lightning itself. Simultaneous measurements were made of RF radiation and fast and slow field changes. Continuous analogue recordings with a system having 300 kHz of bandwidth were made together with digital records of selected events (principally return strokes) at greater temporal resolution. The data reveal patterns in the RF radiation for the entire flash which are characteristic of flash type and independent of the frequency of observation. Individual events within the flash also have characteristic RF patterns. Strong radiation occurs during the first return strokes, but delayed about 20 micron sec with respect to the begining of the return stroke; whereas, RF radiation from subsequent return strokes tends to be associated with cloud processes preceding the flash with comparatively little radiation occurring during the return stroke itself.

Levine, D. M.↗

An investigation of air solubility in Jet A fuel at high pressures

Problems concerned with the supercritical injection concept are discussed. Supercritical injection involves dissolving air into a fuel prior to injection. A similar effect is obtained by preheating the fuel so that a portion of the fuel flashes when its pressure is reduced. Flashing improves atomization properties and the presence of air in the primary zone of a spray flame reduces the formation of pollutants. The investigation is divided into three phases: (1) measure the solubility and density properties of fuel/gas mixtures, including Jet A/air, at pressures and correlate these results using theory; (2) investigate the atomization properties of flashing liquids, including fuel/dissolved gas systems. Determine and correlate the effect of inlet properties and injector geometry on mass flow rates, Sauter mean diameter and spray angles; (3) examine the combustion properties of flashing injection in an open burner flame, considering flame shape and soot production.

Faeth, G. M.↗

Thermonuclear processes on accreting neutron stars - A systematic study

A series of model calculations for the evolution of the surface layers of an accreting neutron star is carried out. The neutron star mass, radius, core temperature, and surface magnetic field strength are systematically varied, as are the accretion rate onto the neutron star surface and the metallicity of the accreting matter, in order to determine the effects of these parameters on the properties of thermonuclear flashes in the surface layers and the emitted X-ray bursts that result from such flashes. The core temperatures required for thermal equilibrium are found to be approximately a factor of 2 lower than estimated in earlier work. Owing to the effects of the gravitational redshift, the emitted X-ray bursts have lower peak luminosities and longer durations than those calculated in the Newtonian approximation. The entrainment of hydrogen into helium flashes can cause the flashes to exhibit a rather wide range of observable effects and can decrease by a factor of more than 2 the ratio of persistent accretion-driven luminosity to time-averaged burst luminosity emitted by the neutron star.

Ayasli, S.↗

Lightning activity observed in upper and lower portions of storms and its relationship to storm structure from VHF mapping and Doppler radar

Space time mapping of very high frequencies (VHF) sources reveals lightning processes for cloud to ground (CG) and for large intracloud (IC) flashes are confined to an altitude below about 10 km and closely associated with the central high reflectivity region of a storm. Another class of IC flashes was identified that produces a splattering of small sources within the main electrically active volume of a storm and also within a large divergent wind canopy at the top of a storm. There is no apparent temporal association between the small high altitude IC flashes occurring almost continuously and the large IC and CG flashes sporadically occurring in the lower portions of storms.

Taylor, W. L.↗

Lightning activity on Jupiter

Photographic observations of the nightside of Jupiter by the Voyager 1 spacecraft show the presence of extensive lightning activity. Detection of whistlers by the plasma wave analyzer confirms the optical observations and implies that many flashes were not recorded by the Voyager camera because the intensity of the flashes was below the threshold sensitivity of the camera. Measurements of the optical energy radiated per flash indicate that the observed flashes had energies similar to that for terrestrial superbolts. The best estimate of the lightning energy dissipation rate of 0.0004 W/sq m was derived from a consideration of the optical and radiofrequency measurements. The ratio of the energy dissipated by lightning compared to the convective energy flux is estimated to be between 0.000027 and 0.00005. The terrestrial value is 0.0001.

Borucki, W. J.↗

Hy-wire and fast electric field change measurements near an isolated thunderstorm, appendix C

Electric field measurements near an isolated thunderstorm at 6.4 km distance are presented from both a tethered balloon experiment called Hy-wire and also from ground based fast and slow electric field change systems. Simultaneous measurements were made of the electric fields during several lightning flashes at the beginning of the storm which the data clearly indicate were cloud-to-ground flashes. In addition to providing a comparison between the Hy-wire technique for measuring electric fields and more traditional methods, these data are interesting because the lightning flashes occurred prior to changes in the dc electric field, although Hy-wire measured changes in the dc field of up to 750 V/m in the direction opposite to the fair weather field a short time later. Also, the dc electric field was observed to decay back to its preflash value after each flash. The data suggest that Hy-wire was at the field reversal distance from this storm and suggest the charge realignment was taking place in the cloud with a time constant on the order of 20 seconds.

Holzworth, R. H.↗

Lightning Observations above and below clouds

The quantitative optical characteristics of cloud to ground (CG) and intracloud (IC) lightning above clouds were studied. A data base of a number of pulse paramaters such as energy, rise times, pulse widths and pulse intervals was complied and categorized for first return strokes, subsequent strokes, the intracloud part of CG flashes and IC flashes. It is found that: (1) single stroke CG's are more readily distinguishable from IC flashes than multiple stroke CG's; (2) there is no significant difference between the energy of first and subsequent return stroke pulses; and (3) the pulse rise times and pulse widths are time broadened. Lightning activity in a mesoscale convective weather system (MCS) was examined. The CG flash rates average almost 50 per minute for 7 hours. It is shown that lightning above storms embedded within the MCS IC lightning activity can be much greater than CG activity at certain times in the MCS lifecycle.

Goodman, S. J.↗

Lightning and related phenomena in thunderstorms and squall lines

During the past few years, cooperative research on storm electricity has yielded the following results of both basic and applied interest: (1) the intracloud to cloud-to-ground flashing ratio can be as great as 40:1; (2) as storm cells in a squall line dissipate, longer flashes become predominant; (3) there are two centers of lightning activity maxima that are vertically separated, the lower maximum at about 5 km and the upper at about 12 km. In addition, (4) storms produce lightning in their upper regions at a high rate; (5) lightning appears to be related in time to convective motions; (6) positive cloud-to-ground flashes occur in the severe stage of storms and in the later, well-developed stage of squall line storms; (7) mesoscale convective complexes have been observed to have cloud-to-ground flashing rates of more than 48/min; and (8) the electric field in anvils well away from the main storm core (more than 60 km) can be very high, more than 94 kV/m.

Rust, W. D.↗

Conditions for lightning strikes to an airplane in a thunderstorm

Conditions conducive to lightning strikes on aircraft were determined through the 1982 Storm Hazards Program. UHF-radar and SPANDAR were used to guide a NASA F-106B research aircraft through the upper regions of active thunderstorms to facilitate direct lightning strikes to the aircraft. Analysis of radar echoes from lightning at the moments of the strikes suggests that the aircraft itself triggers the lightning, in both stormy and nonstormy clouds, and that the induced flashes are not much different from naturally occurring intra-cloud flashes. The highest risk for a direct strike in the upper portions of a thunderstorm occurred where the ambient temperature was -40 C or colder, where turbulence and precipitation were negligible to light, and where the lightning flash rate was no greater than 5 flashes per minute.

Mazur, V.↗