Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “exchanger”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Analysis of Ion-Exchanged ZSM-5, BEA, and SSZ-13 Zeolite Trapping Materials under Realistic Exhaust Conditions

An industry-defined evaluation protocol was used to evaluate the hydrocarbon trapping (HCT) and passive NOx adsorption (PNA) potential for BEA, ZSM-5, and SSZ-13 zeolites with ion-exchanged Pd or Ag. All materials underwent 700 °C degreening prior to exposure to an industry-derived protocol gas stream, which included NOx, ethylene, toluene, and decane as measured trapping species as well as common exhaust gasses CO, H2O, O2, CO2, and H2. Evaluation showed that BEA and ZSM-5 zeolites were effective at trapping hydrocarbons (HCs), as saturation was not achieved after 30 min of exposure. SSZ-13 also stored HCs but was only able to adsorb 20–25% compared to BEA and ZSM-5. The presence of Ag or Pd did not impact the overall HC uptake, particularly in the first three minutes. Pd/zeolites had significantly lower THC release temperature, and it aided in the conversion of the released HCs; Ag only had a moderate effect in both areas. With respect to NOx adsorption, the level of uptake was much lower than HCs on all samples, and Ag or Pd was necessary with Pd being notably more effective. Additionally, only Pd/ZSM-5 and Pd/SSZ-13 continue to store a portion of the NOx above 200 °C, which is critical for downstream selective catalytic NOx reduction (SCR). Hydrothermal aging (800 °C for 50 h) of a subset of the samples were performed: BEA, Pd/BEA, ZSM-5, Pd/ZSM-5, and Pd/SSZ-13. There was a minimal effect on the HC storage, ~10% reduction in capacity with no effect on release temperature; however, only Pd/SSZ-13 showed significant NOx storage after aging.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimentally Measured Thermal Masses of Adsorption Heat Exchangers

The thermal masses of components influence the performance of many adsorption heat pump systems. However, typically when experimental adsorption systems are reported, data on thermal mass are missing or incomplete. This work provides original measurements of the thermal masses for experimental sorption heat exchanger hardware. Much of this hardware was previously reported in the literature, but without detailed thermal mass data. The data reported in this work are the first values reported in the literature to thoroughly account for all thermal masses, including heat transfer fluid. The impact of thermal mass on system performance is also discussed, with detailed calculation left for future work. The degree to which heat transfer fluid contributes to overall effective thermal mass is also discussed, with detailed calculation left for future work. This work provides a framework for future reporting of experimental thermal masses. The utilization of this framework will enrich the data available for model validation and provide a more thorough accounting of adsorption heat pumps.

30 DIRECT ENERGY CONVERSION↗

Prediction of Performance Variation Caused by Manufacturing Tolerances and Defects in Gas Diffusion Electrodes of Phosphoric Acid (PA)–Doped Polybenzimidazole (PBI)-Based High-Temperature Proton Exchange Membrane Fuel Cells

The automated process of coating catalyst layers on gas diffusion electrodes (GDEs) for high-temperature proton exchange membrane fuel cells results inherently into a number of defects. These defects consist of agglomerates in which the platinum sites cannot be accessed by phosphoric acid and which are the consequence of an inconsistent coating, uncoated regions, scratches, knots, blemishes, folds, or attached fine particles—all ranging from μm to mm size. These electrochemically inactive spots cause a reduction of the effective catalyst area per unit volume (cm2/cm3) and determine a drop in fuel cell performance. A computational fluid dynamics (CFD) model is presented that predicts performance variation caused by manufacturing tolerances and defects of the GDE and which enables the creation of a six-sigma product specification for Advent phosphoric acid (PA)-doped polybenzimidazole (PBI)-based membrane electrode assemblies (MEAs). The model was used to predict the total volume of defects that would cause a 10% drop in performance. It was found that a 10% performance drop at the nominal operating regime would be caused by uniformly distributed defects totaling 39% of the catalyst layer volume (~0.5 defects/μm2). The study provides an upper bound for the estimation of the impact of the defect location on performance drop. It was found that the impact on the local current density is higher when the defect is located closer to the interface with the membrane. The local current density decays less than 2% in the presence of an isolated defect, regardless of its location along the active area of the catalyst layer.

Gurau, Vladimir (ORCID:0000000327429061)↗

Uncovering Structure–Conductivity Relationships in Anion Exchange Membranes (AEMs) Using Interpretable Machine Learning

Anion exchange membranes (AEMs) play a vital role in the performance of water electrolyzers and fuel cells, yet their discovery and optimization remain challenging due to the complexity of structure–property relationships. In this study, we introduce a machine learning framework that leverages conditional graph neural networks (cGNNs) and descriptor-based models and a hybrid graph neural network (HGARE) to predict and interpret ionic conductivity. The descriptor-based pipeline employs principal component analysis (PCA), ablation, and SHAP analysis to identify factors governing anion conductivity, revealing electronic, topological, and compositional descriptors as key contributors. Beyond prediction, dimensionality reduction and clustering are performed by employing t-SNE and KMeans as well as SOM, which reveal distinct membranes clusters, some of which were enriched with high anion conductivity. Among graph-based approaches, the graph convolutional (GCN) achieved strong predictive performance, while the Hybrid Graph Autoencoder-Regressor Ensemble (HGARE) achieved the highest accuracy. Additionally, atom-level saliency maps from GCN provide spatial explanations for conductive behavior, revealing the importance of polarizable and flexible regions. This work contributes to the accelerated and data-driven design of high-performance AEMs.

Naghshnejad, Pegah [Department of Chemical Enginee↗

Structural, Thermal, and Mechanical Characterization of a Thermally Conductive Polymer Composite for Heat Exchanger Applications

Polymer composites are being considered for numerous thermal applications because of their inherent benefits, such as light weight, corrosion resistance, and reduced cost. In this work, the microstructural, thermal, and mechanical properties of a 3D printed polymer composite with high thermal conductivity are examined using multiple characterization techniques. Infrared spectroscopy and X-ray diffraction reveal that the composite contains a polyphenylene sulfide matrix with graphitic fillers, which is responsible for the high thermal conductivity. Furthermore, differential scanning calorimetry determines that the glass transition and melting point of the composite are 87.6 °C and 285.6 °C, respectively. Thermogravimetric analysis reveals that the composite is thermally stable up to ~400 °C. Creep tests are performed at different isotherms to evaluate the long-term performance of the composite. The creep result indicates that the composite can maintain mechanical integrity when used below its glass transition temperature. Nanoindentation tests reveal that modulus and hardness of the composite is not significantly influenced by heating or creep conditions. These findings indicate that the composite is potentially suitable for heat exchanger applications.

36 MATERIALS SCIENCE↗

Magnetogenesis by Wave-driven Momentum Exchange

When multiple species interact with an electrostatic ion acoustic wave, they can exchange momentum, despite the lack of momentum in the field itself. Furthermore, the resulting force on the electrons can have a curl, and thus give rise to compensating electric fields with curl on magnetohydrodynamic timescales. As a result, a magnetic field can be generated. Surprisingly, in some astrophysical settings, this mechanism can seed magnetic fields with growth rates even larger than through the traditional Biermann battery.

79 ASTRONOMY AND ASTROPHYSICS↗

Ion-exchange membrane with molecular barrier

Disclosed is an ion-exchange membrane that includes a molecular barrier for influencing permeation selectivity through the membrane. The membrane includes fluorinated carbon backbone chains and fluorinated side chains that extend off of the fluorinated carbon backbone chains. The fluorinated side chains include acid groups for ionic conductivity. The acid groups surround and define permeable domains that are free of the fluorinated carbon backbone chains. Molecular barriers are located in the permeable domains and influence permeability through the domains.

25 ENERGY STORAGE↗

Hybrid metal-polymer heat exchanger

A heat exchanger includes a metal tube and a composite polymer fin in thermal contact with the metal tube. The fin is formed of a polymer and a thermally conductive filler such that the fin has a thermal conductivity greater than or equal to 0.5 Watts per meter Kelvin.

42 ENGINEERING↗

Bi-directional porous media phase change heat exchanger

Heat exchange structure. A hydrophilic, thermally conductive porous medium includes nanostructures formed substantially uniformly throughout the porous medium providing a balance of capillary and viscous forces to self-regulate a liquid-vapor contact line. A suitable porous medium is copper. A method for making the structure is also disclosed.

42 ENGINEERING↗

Air bearing heat exchanger methods

The various technologies presented herein relate to fabrication and operation of a heat exchanger that is configured to extract heat from an underlying substrate. Heat can be extracted by way of an air gap formed between an impeller and a baseplate. By utilizing a pump to create an initial air gap that is further maintained by rotation of the impeller relative to the baseplate, a spring can be utilized that can apply a force of greater magnitude to the impeller than is used in a conventional approach, thus enabling the weight of the impeller to be negligible with respect to a width of the air gap, thereby conferring the desirable feature of orientation independence with respect to gravity with no performance degradation.

42 ENGINEERING↗

A Study on Computational Cost Reduction of Simulations of Phase-Change Material (PCM) Embedded Heat Exchangers

Thermal storage can be implemented using Phase-Change Materials (PCM), which absorb significant latent heat with a relatively small temperature change. PCM phase-change processes are transient and are driven by thermal diffusion and natural convection – the latter, especially for melting process. Modeling and simulation of PCM heat exchangers (HX’s) is typically computationally intensive due to the relatively complex time-dependent physics. Most of the PCM modeling work in the literature uses high-order modeling tools such as Computational Fluid Dynamics (CFD) and Lattice-Boltzmann Method (LBM). For design purposes, the existing PCM modeling approaches are not practical, limiting researchers in their ability to investigate new ideas and different PCM’s with faster turnarounds. This paper presents a study investigating the reduction of computational cost of PCM embedded HX’s CFD models by evaluating the feasibility of spatial reduction without losing accuracy. The analysis consists of comparing full and partial domain under full melting conditions. The subject of this study is a single straight tube with circular transverse fins in the vertical orientation, using PCM’s with 35oC nominal melting temperature. Different tube and fin dimensions are investigated. Results indicate that the reduced domain reproduces - in half the run time - the same behavior as the full domain since the buoyancy effects are localized and patterned. The outputs from the partial domain simulation were used to build a non-general correlation for the PCM heat transfer characteristics and demonstrated how it can be implemented in a Finite Control Volume Reduced Order Model (ROM). The ROM can accurately reproduce the CFD simulations at 4 to 5 orders of magnitude faster.

25 ENERGY STORAGE↗

Automated Parameterized CFD Simulations of Phase-Change Material Embedded Heat Exchangers

Thermal storage can be implemented using Phase-Change Materials (PCM), which absorb significant latent heat with a relatively small temperature change. PCM phase-change processes are transient and are driven by thermal diffusion and natural convection – the latter, especially for melting process. Modeling and simulation of PCM heat exchangers is typically computationally intensive due to the relative complex time-dependent underlying physics. This paper presents a study investigating a single straight tube with circular transverse fins in the vertical orientation, using PCM’s with 37oC nominal melting temperature, leveraging automated parametric CFD simulations. The computational domain is reduced to 2D axisymmetric for a segment of the HX comprising a region in between two fins with constant wall temperature as boundary condition. This approach allows for faster evaluations of the transient thermal characteristics for a given design space of interest. Correlations and reduced order models (ROM’s) are developed. Results indicate that the ROM’s reproduce the CFD simulations with high accuracy for designs from the training data set, however, designs from cross-validation and test sets do not always have good agreement. The limited number of designs in the training set is a possible cause for the lack of robustness of the ROM’s and thus additional training designs will be added in future work. The ROM’s solve the simulations on average 500,000 times faster than CFD.

25 ENERGY STORAGE↗

Effectiveness of Advanced Three Fluid Heat and Mass Exchanger

Advanced internally-cooled membraned-based heat and mass exchangers (HMX), which accounts for three separate fluid streams, are capable of utilizing the sensible and latent heat removed from spacecooling to heat water. The technology provides a unique approach of enhancing the efficiency and cost effectiveness of future HVAC equipment. This paper aims to numerically identify and understand the impact of geometric size, operation conditions, and membrane properties on the overall effectiveness of three-fluid HMXs. The simulations are based on an ORNL in-house open-source HMX model which is capable of simulating such three-fluid HMX components for various flow patterns. The results are expected to enable detailed configuration evaluation and provide in-depth understanding of optimal three-fluid HMX performance at cost effectiveness.

Gao, Zhiming↗

AMS INTERNATIONAL TECHNICAL EXCHANGES - IAEA-CN293-047

The IAEA Conference on the Development of Preparedness for National and International Emergency Response 2021. The purpose of the event is to foster the exchange of information and enhance global awareness on various EPR topics through the discussion of both the progress made at national and international levels and the challenges encountered, by sharing experiences, evaluating current trends, technologies and lessons in EPR

99 GENERAL AND MISCELLANEOUS↗

Branching heat exchangers

A heat exchanger includes an external casing and a core. The external casing includes a first inlet, a first outlet, a second inlet, and a second outlet. The core includes an array of branched channels connecting the first inlet and first outlet, an inlet header, and an outlet header. The inlet header is integrally formed with and fluidly connected to the first inlet. The outlet header is integrally formed with and fluidly connected to the first outlet. The branched channels and the external casing define a fluidic passage. The array of branched channels includes a first split, a first juncture, a secondary split, a secondary juncture, and a subset of splits and junctures. The first split and first juncture are common to an entirety of the array of branched channels. The subset of splits and junctures route fluid through interconnections between fluidly parallel branched channels.

Ranjan, Ram↗