Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Comparing range data across the slow-time dimension to correct motion measurement errors beyond the range resolution of a synthetic aperture radar

Motion measurement errors that extend beyond the range resolution of a synthetic aperture radar (SAR) can be corrected by effectively decreasing the range resolution of the SAR in order to permit measurement of the error. Range profiles can be compared across the slow-time dimension of the input data in order to estimate the error. Once the error has been determined, appropriate frequency and phase correction can be applied to the uncompressed input data, after which range and azimuth compression can be performed to produce a desired SAR image.

Doerry, Armin W↗

Ray tracing evaluation of a technique for correcting the refraction errors in satellite tracking data

Errors may be introduced in satellite laser ranging data by atmospheric refractivity. Ray tracing data have indicated that horizontal refractivity gradients may introduce nearly 3-cm rms error when satellites are near 10-degree elevation. A correction formula to compensate for the horizontal gradients has been developed. Its accuracy is evaluated by comparing it to refractivity profiles. It is found that if both spherical and gradient correction formulas are employed in conjunction with meteorological measurements, a range resolution of one cm or less is feasible for satellite elevation angles above 10 degrees.

Gardner, C. S.↗

Error Detection and Correction LDMS Plugin Version 1.0

Sandia's Lightweight Distributed Metric Service (LDMS) is a data collection and transport system used at Livermore Computing to gather performance data across the center. While Sandia has a set of plugins available, they do not include all the data we need to capture. The ECAC plugin that we have developed enables collection of the Error Detection and Correction (EDAC) counters.

Shoga, Kathleen↗

Error Detection and Correction LDMS Plugin Version 1.0

Sandia's Lightweight Distributed Metric Service (LDMS) is a data collection and transport system used at Livermore Computing to gather performance data across the center. While Sandia has a set of plugins available, they do not include all the data we need to capture. The ECAC plugin that we have developed enables collection of the Error Detection and Correction (EDAC) counters.

Shoga, Kathleen↗

Regional Multistation Discriminants: Magnitude, Distance and Amplitude Corrections and Sources of Error

Magnitude, distance and amplitude corrections (MDAC) made to observed regional amplitudes are necessary so that what remains in the corrected amplitude is mostly information about the seismic source-type. Corrected amplitudes can be used in ratios to discriminate between earthquakes and explosions. However, there remain source effects such as those due to depth, focal mechanism, local material property and apparent stress variability that cannot easily be determined and applied as amplitude corrections. We develop a mathematical model to capture such effects as random (unknown) giving an error partition of two sources: model inadequacy and station noise. This mathematical model is the basis for a general multi-station regional discriminant formulation. The standard error of the discriminant includes the variances of model inadequacy and station noise in its formulation. The developed methods are demonstrated for a suite of Nevada Test Site (NTS) events observed at regional stations. Importantly, the proposed formulation includes all corrected amplitude information through the construction of multi-station discriminants. In contrast, previous studies have only computed discriminants from single stations having both P and S amplitudes. The proposed multi-station approach has similarities to the well established mb versus Ms discriminant.

58 GEOSCIENCES↗

Electron Capture into Rydberg States According to the Born Approximation: Correction of an Error

A general expression is derived for the Born amplitude for electron capture into high principal, and arbitrary angular momentum, quantum numbers, n and l, by bare nuclei from hydrogenic atom targets. Cross sections for capture into high n and l = 0,1 are given in analytic forms. The limiting values of the ratios of the Born over OBK cross sections for n >> 1 and l = 0,1 are found, and shown that they confirm the empirical law of Jackson and Schiff only approximately. For high angular momenta, it is shown that the Born cross section approaches the OBK cross section. An error in a previous publication by the author has been corrected.

Omidvar, Kazem↗

Error detection and correction utilizing locally stored parity information

A processing system includes a memory coupled to a processor. The memory stores data blocks, with each data block having a separate associated checksum value stored along with the data block in the memory. The processor has a storage location that stores parity information for the data blocks, with the parity information having a plurality of parity blocks. Each parity block represents a parity of a corresponding set of data blocks. The parity blocks can be accessed for use in error detection and correction schemes used by the processing system.

97 MATHEMATICS AND COMPUTING↗

Leveraging Qubit Loss Detection in Fault-Tolerant Quantum Algorithms

Qubit loss errors constitute a dominant source of noise in many quantum hardware systems, particularly in neutral-atom quantum computers. We develop a theoretical framework to effectively detect and correct loss errors in logical algorithms and leverage such loss information in decoding. Considering general quantum error correction codes and logical circuits, we introduce a delayed-erasure decoder for experimentally motivated error models which leverages information from delayed loss detection to accurately correct loss errors, even when the precise moment of the error is unknown. Using this decoder, we identify strategies for detecting and correcting loss errors based on the logical circuit structure. For deep circuits prior to logical measurement, we explore methods to integrate loss detection into syndrome extraction with minimal overhead, identifying optimal strategies depending on the qubit loss fraction in the noise and hardware capabilities. In contrast, we find that many key algorithmic subroutines involve frequent gate teleportation, shortening the circuit depth before logical measurement and naturally replacing qubits with no additional experimental overhead. We simulate this setting using a toy model algorithm for small-angle synthesis and find a significant performance improvement as the loss fraction increases. These results provide a path forward for advancing large-scale fault-tolerant quantum computation in systems with loss error detection.

atoms↗

A Nucleotide-Analogue-Induced Gain of Function Corrects the Error-Prone Nature of Human DNA Polymerase iota

Y-family DNA polymerases participate in replication stress and DNA damage tolerance mechanisms. The properties that allow these enzymes to copy past bulky adducts or distorted template DNA can result in a greater propensity for them to make mistakes. Of the four human Y-family members, human DNA polymerase iota (hpol{iota}) is the most error-prone. In the current study, we elucidate the molecular basis for improving the fidelity of hpol{iota} through use of the fixed-conformation nucleotide North-methanocarba-2{prime}-deoxyadenosine triphosphate (N-MC-dATP). Three crystal structures were solved of hpol{iota} in complex with DNA containing a template 2{prime}-deoxythymidine (dT) paired with an incoming dNTP or modified nucleotide triphosphate. The ternary complex of hpol{iota} inserting N-MC-dATP opposite dT reveals that the adenine ring is stabilized in the anti orientation about the pseudo-glycosyl torsion angle, which mimics precisely the mutagenic arrangement of dGTP:dT normally preferred by hpol{iota}. The stabilized anti conformation occurs without notable contacts from the protein but likely results from constraints imposed by the bicyclo[3.1.0]hexane scaffold of the modified nucleotide. Unmodified dATP and South-MC-dATP each adopt syn glycosyl orientations to form Hoogsteen base pairs with dT. The Hoogsteen orientation exhibits weaker base-stacking interactions and is less catalytically favorable than anti N-MC-dATP. Thus, N-MC-dATP corrects the error-prone nature of hpol{iota} by preventing the Hoogsteen base-pairing mode normally observed for hpol{iota}-catalyzed insertion of dATP opposite dT. These results provide a previously unrecognized means of altering the efficiency and the fidelity of a human translesion DNA polymerase.

59 BASIC BIOLOGICAL SCIENCES↗

Test results of an ITER relevant FPGA when irradiated with neutrons

The data acquisition and control instrumentation cubicles room of the ITER tokamak will be irradiated with neutrons during the fusion reactor operation. A Virtex-6 FPGA from Xilinx (XC6VLX365T-1FFG1156C) is used on the ATCA-IO-PROCESSOR board, included in the ITER Catalog of I and C products - Fast Controllers. The Virtex-6 is a re-programmable logic device where the configuration is stored in Static RAM (SRAM), functional data stored in dedicated Block RAM (BRAM) and functional state logic in Flip-Flops. Single Event Upsets (SEU) due to the ionizing radiation of neutrons causes soft errors, unintended changes (bit-flips) to the values stored in state elements of the FPGA. The SEU monitoring and soft errors repairing, when possible, were explored in this work. An FPGA built-in Soft Error Mitigation (SEM) controller detects and corrects soft errors in the FPGA configuration memory. Novel SEU sensors with Error Correction Code (ECC) detect and repair the BRAM memories. Proper management of SEU can increase reliability and availability of control instrumentation hardware for nuclear applications. The results of the tests performed using the SEM controller and the BRAM SEU sensors are presented for a Virtex-6 FPGA (XC6VLX240T-1FFG1156C) when irradiated with neutrons from the Portuguese Research Reactor (RPI), a 1 MW nuclear fission reactor operated by IST in the neighborhood of Lisbon. Results show that the proposed SEU mitigation technique is able to repair the majority of the detected SEU errors in the configuration and BRAM memories. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Tunable, Software-based DRAM Error Detection and Correction Library for HPC

Proposed exascale systems will present a number of considerable resiliency challenges. In particular, DRAM soft-errors, or bit-flips, are expected to greatly increase due to the increased memory density of these systems. Current hardware-based fault-tolerance methods will be unsuitable for addressing the expected soft error frequency rate. As a result, additional software will be needed to address this challenge. In this paper we introduce LIBSDC, a tunable, transparent silent data corruption detection and correction library for HPC applications. LIBSDC provides comprehensive SDC protection for program memory by implementing on-demand page integrity verification. Experimental benchmarks with Mantevo HPCCG show that once tuned, LIBSDC is able to achieve SDC protection with 50\% overhead of resources, less than the 100\% needed for double modular redundancy.

99 GENERAL AND MISCELLANEOUS↗

Bias Correction and Random Error Characterization for the Assimilation of HRDI Line-of-Sight Wind Measurements

A new approach to the analysis of systematic and random observation errors is presented in which the error statistics are obtained using forecast data rather than observations from a different instrument type. The analysis is carried out at an intermediate retrieval level, instead of the more typical state variable space. This method is carried out on measurements made by the High Resolution Doppler Imager (HRDI) on board the Upper Atmosphere Research Satellite (UARS). HRDI, a limb sounder, is the only satellite instrument measuring winds in the stratosphere, and the only instrument of any kind making global wind measurements in the upper atmosphere. HRDI measures doppler shifts in the two different O2 absorption bands (alpha and B) and the retrieved products are tangent point Line-of-Sight wind component (level 2 retrieval) and UV winds (level 3 retrieval). This analysis is carried out on a level 1.9 retrieval, in which the contributions from different points along the line-of-sight have not been removed. Biases are calculated from O-F (observed minus forecast) LOS wind components and are separated into a measurement parameter space consisting of 16 different values. The bias dependence on these parameters (plus an altitude dependence) is used to create a bias correction scheme carried out on the level 1.9 retrieval. The random error component is analyzed by separating the gamma and B band observations and locating observation pairs where both bands are very nearly looking at the same location at the same time. It is shown that the two observation streams are uncorrelated and that this allows the forecast error variance to be estimated. The bias correction is found to cut the effective observation error variance in half.

Tangborn, Andrew↗

Quantum error thresholds for gauge-redundant digitizations of lattice field theories

In the quantum simulation of lattice gauge theories, gauge symmetry can be either fixed or encoded as a redundancy of the Hilbert space. While gauge-fixing reduces the number of qubits, keeping the gauge redundancy can provide code space to mitigate and correct quantum errors by checking and restoring Gauss’s law. In this work, we consider the correctable errors for generic finite gauge groups and design the quantum circuits to detect and correct them. We calculate the error thresholds below which the gauge-redundant digitization with Gauss’s law error correction has better fidelity than the gauge-fixed digitization involving only gauge-invariant states. Our results provide guidance for fault-tolerant quantum simulations of lattice gauge theories. Published by the American Physical Society 2024

97 MATHEMATICS AND COMPUTING↗

Physically based correction of systematic errors of Rotating Shadowband Irradiometers

Accurate measurements of direct normal, diffuse horizontal and global horizontal irradiance (DNI, DHI and GHI) are needed for meteorological studies and are essential for the solar resource assessment at potential solar power plant sites. Often, these potential sites are remote and hence require robust sensors that require minimal maintenance that are not affected strongly by soiling. Therefore, Rotating Shadowband Irradiometers (RSI) are widely used for resource assessment. To achieve the required accuracy, corrections for the raw values of RSIs depending on systematic temperature, incidence angle and spectral errors must be used, and a thorough calibration of the sensor head must be applied. The existing correction functions are derived from comparisons of RSIs to thermopile radiometers at selected sites and therefore empirical. Their accuracy is considered to be site dependent. In this work a new correction and calibration method is presented that removes the systematic errors using a physical approach. It is based on information of the sensor properties as well as measurements of its directional response, and incorporates the atmospheric conditions at the measurement site. In this case, no empiric relations obtained from a specific site are required. The method requires estimates of the current DHI and GHI spectra during each measurement of the RSI. Based on these spectra, a spectral correction, which includes a spectrum dependent temperature correction, can be made without employing empirical relationships. The new physical calibration and correction method is tested at three sites and reaches similar results compared to the empirical functions. This is already achieved with rudimentary estimations of the GHI and DHI spectra and we expect that these estimations can be improved in the future. The results indicate that the physical approach reduces the problematic location dependence of the current calibration and correction methods. The physical correction and calibration method show promise for a further improvement of the RSI accuracy.

47 OTHER INSTRUMENTATION↗

Correction of quantification errors in pelvic and spinal lesions caused by ignoring higher photon attenuation of bone in [{sup 18}F]NaF PET/MR

Purpose: MR-based attenuation correction (MRAC) in routine clinical whole-body positron emission tomography and magnetic resonance imaging (PET/MRI) is based on tissue type segmentation. Due to lack of MR signal in cortical bone and the varying signal of spongeous bone, standard whole-body segmentation-based MRAC ignores the higher attenuation of bone compared to the one of soft tissue (MRAC{sub nobone}). The authors aim to quantify and reduce the bias introduced by MRAC{sub nobone} in the standard uptake value (SUV) of spinal and pelvic lesions in 20 PET/MRI examinations with [{sup 18}F]NaF. Methods: The authors reconstructed 20 PET/MR [{sup 18}F]NaF patient data sets acquired with a Philips Ingenuity TF PET/MRI. The PET raw data were reconstructed with two different attenuation images. First, the authors used the vendor-provided MRAC algorithm that ignores the higher attenuation of bone to reconstruct PET{sub nobone}. Second, the authors used a threshold-based algorithm developed in their group to automatically segment bone structures in the [{sup 18}F]NaF PET images. Subsequently, an attenuation coefficient of 0.11 cm{sup −1} was assigned to the segmented bone regions in the MRI-based attenuation image (MRAC{sub bone}) which was used to reconstruct PET{sub bone}. The automatic bone segmentation algorithm was validated in six PET/CT [{sup 18}F]NaF examinations. Relative SUV{sub mean} and SUV{sub max} differences between PET{sub bone} and PET{sub nobone} of 8 pelvic and 41 spinal lesions, and of other regions such as lung, liver, and bladder, were calculated. By varying the assigned bone attenuation coefficient from 0.11 to 0.13 cm{sup −1}, the authors investigated its influence on the reconstructed SUVs of the lesions. Results: The comparison of [{sup 18}F]NaF-based and CT-based bone segmentation in the six PET/CT patients showed a Dice similarity of 0.7 with a true positive rate of 0.72 and a false discovery rate of 0.33. The [{sup 18}F]NaF-based bone segmentation worked well in the pelvis and spine. However, it showed artifacts in the skull and in the extremities. The analysis of the 20 [{sup 18}F]NaF PET/MRI examinations revealed relative SUV{sub max} differences between PET{sub nobone} and PET{sub bone} of (−8.8% ± 2.7%, p = 0.01) and (−8.1% ± 1.9%, p = 2.4 × 10{sup −8}) in pelvic and spinal lesions, respectively. A maximum SUV{sub max} underestimation of −13.7% was found in lesion in the third cervical spine. The averaged SUV{sub mean} differences in volumes of interests in lung, liver, and bladder were below 3%. The average SUV{sub max} differences in pelvic and spinal lesions increased from −9% to −18% and −8% to −17%, respectively, when increasing the assigned bone attenuation coefficient from 0.11 to 0.13 cm{sup −1}. Conclusions: The developed automatic [{sup 18}F]NaF PET-based bone segmentation allows to include higher bone attenuation in whole-body MRAC and thus improves quantification accuracy for pelvic and spinal lesions in [{sup 18}F]NaF PET/MRI examinations. In nonbone structures (e.g., lung, liver, and bladder), MRAC{sub nobone} yields clinically acceptable accuracy.

60 APPLIED LIFE SCIENCES↗