Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “doppler”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Particle flow within a transonic compressor rotor passage with application to laser-Doppler velocimetry

A theoretical analysis was conducted of the dynamic behavior of micron size particles moving in the three-dimensional flow field of a rotating transonic axial-flow air compressor rotor. The particle velocity lag and angular deviation relative to the gas were determined as functions of particle diameter, mass density and radial position. Particle size and density were varied over ranges selected to correspond to typical laser-Doppler velocimeter (LDV) flow field mapping applications. It was found that the particles move essentially on gas stream surfaces and that particle tracking is relatively insensitive to the rotor radial coordinate. Velocity lag and angular deviation increased whenever particle size or mass density increased, and particle tracking was more sensitive to a change in particle diameter than to a corresponding change in mass density. Results indicated that velocity and angular deviations generally less than 1 percent and 1 degree could be achieved with 1 gm/cc tracer particles with diameters of 1 micron or less.

Maxwell, B. R.↗

Dual wavelength scanning Doppler velocimeter

A laser Doppler velocimeter is described simultaneously measuring localized orthogonal velocity components in a fluid stream without perturbation of the flowfield. A first pair of beams of a first common wavelength and a second pair of beams of a second common wavelength are derived from a single laser source, directed along a single optical axis. The respective beams of each pair of beams are disposed parallel to the axis, symmetrically about the axis, and are positioned orthogonally about the axis relative to each other. The four beams are then focused upon a selected test volume within the flowfield. Light scattered at that point is collected by an appropriate optical system and focused onto photodetectors which develop electrical output signals commensurate with the orthogonal velocity components at the test point.

Rloff, K. L.↗

Laser Doppler velocimeter system simulation for sensing aircraft wake vortices. Part 2: Processing and analysis of LDV data (for runs 1023 and 2023)

A data analysis program constructed to assess LDV system performance, to validate the simulation model, and to test various vortex location algorithms is presented. Real or simulated Doppler spectra versus range and elevation is used and the spatial distributions of various spectral moments or other spectral characteristics are calculated and displayed. Each of the real or simulated scans can be processed by one of three different procedures: simple frequency or wavenumber filtering, matched filtering, and deconvolution filtering. The final output is displayed as contour plots in an x-y coordinate system, as well as in the form of vortex tracks deduced from the maxima of the processed data. A detailed analysis of run number 1023 and run number 2023 is presented to demonstrate the data analysis procedure. Vortex tracks and system range resolutions are compared with theoretical predictions.

Meng, J. C. S.↗

Airborne laser Doppler velocimeter

A CO2 laser Doppler detection system has been developed to measure remotely the true airspeed of an aircraft. The system uses a 50-W sealed-off CO2 laser in a homodyne detection system employing a collinear optical telescope, a HgCdTe detector, and a frequency tracking loop. The system was successfully flight-tested on a NASA Convair 990 research aircraft during December 1971 and June 1972. The results indicate that an airspeed measurement under clear weather conditions is feasible up to an altitude of 3000 m with an error of less than 0.5%.-

Munoz, R. M.↗

Flow tracing fidelity of scattering aerosol in laser Doppler velocimetry

An experimental method for the determination of the flow-tracing fidelity of a scattering aerosol used in laser Doppler velocimeters was developed with particular reference to the subsonic turbulence measurements. The method employs the measurement of the dynamic response of a flow-seeding aerosol excited by acoustic waves. The amplitude and frequency of excitation were controlled in order to simulate the corresponding values of fluid turbulence components. Experimental results are presented on the dynamic response of aerosols over the size range from 0.1 to 2.0 microns in diam and over the frequency range 100 Hz to 100 kHz. It was observed that unit-density spherical scatterers with diameters of 0.2 micron followed subsonic air turbulence frequency components up to 100 kHz with 98% fidelity.

Mazumder, M. K.↗

Resonant Doppler velocimeter

Narrow linewidth tunable lasers augur a new kind of laser Doppler velocimetry employing resonant absorption and fluorescence from trace atomic species rather than scattering from particles. This technique may provide better turbulence and small volume information than present velocimetry.

Miles, R. B.↗

Continuous cardiac output measurement - Aspects of Doppler frequency analysis

From the suprasternal notch blood flow velocity in the aorta can be measured non-invasively by a Doppler probe. Integration over systole after frequency analysis gives a measure of stroke volume if a separate diameter observation is incorporated. Frequency analysis by a zero crossing counter or by a set of parallel phaselock loops was less effective than a set of bandpass filters. Observations on dogs, baboons and humans before and after exercise or surgery suggest the indications to be useful. Application to judging heart failure by the effect of introducing a volume load is indicated. Changes in output also are measured in freely moving subjects.

Mackay, R. S.↗

Laser-Doppler measurement of air turbulence

Laser-Doppler system with 10-micron wavelength tracks 1-micron dust particles to measure air turbulence. System is designed for use at airports to measure and track aircraft trailing vortexes.

Huffaker, R. M.↗

Gravitational-wave bursts from the nuclei of distant galaxies and quasars: Proposal for detection using Doppler tracking of interplanetary spacecraft

Supermassive black holes which exist in the nuclei of many quasars and galaxies are examined along with the collapse which forms these holes and subsequent collisions between them which produce strong, broad-band bursts of gravitational waves. Such bursts might arrive at earth as often as 50 times per year--or as rarely as once each 300 years. The detection of such bursts with dual-frequency Doppler tracking of interplanetary spacecraft is considered.

Thorne, K. S.↗

A feasibility study for the detection of upper atmospheric winds using a ground based laser Doppler velocimeter

A possible measurement program designed to obtain the information requisite to determining the feasibility of airborne and/or satellite-borne LDV (Laser Doppler Velocimeter) systems is discussed. Measurements made from the ground are favored over an airborne measurement as far as for the purpose of determining feasibility is concerned. The expected signal strengths for scattering at various altitude and elevation angles are examined; it appears that both molecular absorption and ambient turbulence degrade the signal at low elevation angles and effectively constrain the ground based measurement of elevation angles exceeding a critical value. The nature of the wind shear and turbulence to be expected are treated from a linear hydrodynamic model - a mountain lee wave model. The spatial and temporal correlation distances establish requirements on the range resolution, the maximum detectable range and the allowable integration time.

Thomson, J. A. L.↗

Laser Doppler spectrometer method of particle sizing

A spectrometer for the detection of airborne particulate pollution in the submicron size range is described. In this device, airborne particles are accelerated through a supersonic nozzle, with different sizes achieving different velocities in the gas flow. Information about the velocities of the accelerated particles is obtained with a laser-heterodyne optical system through the Doppler shift of light scattered from the particles. Detection is accomplished by means of a photomultiplier. Nozzle design and signal processing techniques are also discussed.

Weber, F. N.↗

Atmospheric transmission of CO2 laser radiation with application to laser Doppler systems

The molecular absorption coefficients of carbon dioxide, water vapor, and nitrous oxide are calculated at the P16, P18, P20, P22, and P24 lines of the CO2 laser for temperatures from 200 to 300 K and for pressures from 100 to 1100 mb. The temperature variation of the continuum absorption coefficient of water vapor is taken into account semi-empirically from Burch's data. The total absorption coefficient from the present calculations falls within + or - 20 percent of the results of McClatchey and Selby. The transmission loss which the CO2 pulsed laser Doppler system experiences was calculated for flight test conditions for the five P-lines. The total transmission loss is approximately 7 percent higher at the P16 line and 10 percent lower at the P24 line compared to the P20 line. Comparison of the CO2 laser with HF and DF laser transmission reveals the P2(8) line at 3.8 micrometers of the DF laser is much better from the transmission point of view for altitudes below 10 km.

Murty, S. S. R.↗

Directional acoustic measurements by laser Doppler velocimeters

Laser Doppler velocimeters (LDVs) were used as velocity microphones to measure sound pressure level in the range of 90-130 db, spectral components, and two-point cross correlation functions for acoustic noise source identification. Close agreement between LDV and microphone data is observed. It was concluded that directional sensitivity and the ability to measure remotely make LDVs useful tools for acoustic measurement where placement of any physical probe is difficult or undesirable, as in the diagnosis of jet aircraft noise.

Mazumder, M. K.↗

Doppler tracking experiment MA-089

The Doppler tracking experiment was designed to test the feasibility of improved mapping of earth gravity field anomalies by means of the low-low satellite-to-satellite tracking method. All prescribed data have been retrieved and are currently being reduced and analyzed. Baseline data taken while the docking module was still attached to the command and service module indicated that the equipment operated satisfactorily. The efficacy of the two frequency ionospheric correction method has been demonstrated, and preliminary reduction of a data sample has successfully removed extraneous signatures down to the 50-millihertz level, where the rotational motion of the docking module is revealed. Photographs of the docking module, taken shortly after jettison, show that its rotation was stable.

Weiffenbach, G. C.↗

On Similarity Transformation and Geodetic Network Distortions Based on Doppler Satellite Observations

Models used in geodesy to transform two sets of coordinates are studied and distortions in geodetic networks are investigated. Commonly used transformation models are first reviewed and most of them are interpreted. Differences between various models are discussed. Pitfalls in partial solutions are then considered. It is shown that only as many chords and/or directional elements can be used in the computation as are needed to completely determine the size or shape of the polyhedron implied in the set of Cartesian coordinates. Each additional element causes the normal matrix to be singular provided that all correlations between the chords are used. A number of tables and maps indicating distortions in the NAD 27, Precise Traverse M-R '72, AUS, and SAD 69 geodetic datums are also included. The residuals of the coordinates are scanned for systematic patterns after transforming each geodetic system to the NWL9D Doppler system. Also, an attempt is made to show scale distortions in the NAD 27.

Leick, Alfred↗

Ultrasonic Doppler measurement of renal artery blood flow

An extensive evaluation of the practical and theoretical limitations encountered in the use of totally implantable CW Doppler flowmeters is provided. Theoretical analyses, computer models, in-vitro and in-vivo calibration studies describe the sources and magnitudes of potential errors in the measurement of blood flow through the renal artery, as well as larger vessels in the circulatory system. The evaluation of new flowmeter/transducer systems and their use in physiological investigations is reported.

Freund, W. R.↗

Velocity surveys in a turbine stator annular-cascade facility using laser Doppler techniques

A laser Doppler velocimeter (LDV) was used to determine the flow conditions downstream of an annular cascade of stator blades operating at an exit critical velocity ratio of 0.87. Two modes of LDV operation (continuous scan and discrete point) were investigated. Conventional pressure probe measurements were also made for comparison with the LDV results. Biasing errors that occur in the LDV measurement of velocity components were also studied. In addition, the effect of pressure probe blockage on the flow conditions was determined with the LDV. Photographs and descriptions of the test equipment used are given.

Goldman, L. J.↗