Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distributed storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Real-time Implementation of Grid Code Compliant Grid Edge Energy Management System

Integrated distributed energy resources (DER) in a distribution system need to follow grid codes to avoid violations that result in DER/circuit segment disconnection. To comply with grid code requirements at the grid edge level, network constrained grid edge energy management system (EMS) can be deployed. The objective of grid edge EMS is to provide economic solution for active and reactive power DER setpoints at each dispatch interval and ensure voltage regulation to support secure interconnection of the grid edge segment to the distribution system with multiple inverter based DER units. In this work, real-time simulation of grid code compliant grid edge EMS is deployed in a realistic feeder circuit segment. For real-time simulation, communication between the grid edge EMS and DERs is done exploiting IEC 61850-7-420. It enables interoperability among different DERs and grid edge EMS. No prior art has deployed IEC 61850-7-420 GOOSE communication protocol for grid edge EMS. Conversion of IEC 61850 GOOSE messages to Modbus communication protocol is also performed to communicate with grid edge EMS in commodity-off the shelf embedded boards in this work. The real-time simulation in OPAL-RT real-time digital simulator shows the out-performance of grid edge EMS by reducing the voltage violation in the distribution circuit.

Energy management system↗

Barriers to Balcony Solar and Plug-In Distributed Energy Resources in the United States

Plug-in distributed energy resources (DERs), such as balcony solar, backfeed power to the home through a standard plug. These systems may represent the future of residential solar and storage, particularly as recent net metering policies have reduced the economic appeal of rooftop solar. While plug-in DERs have seen widespread success in Europe, their U.S. market is stagnant. This paper reviews the technical, interconnection, and regulatory barriers hindering the adoption of plug-in DERs. We first discuss the technical barriers, which include touch safety, breaker masking, and bidirectional ground-fault circuit interrupters. We then examine utility perspectives on plug-in DERs and strategies for navigating interconnection challenges. Finally, we discuss regulatory hurdles related to UL standards and the National Electrical Code.

Gerber, Daniel L. (ORCID:0000000219720679)↗

Carbon cycle extremes accelerate weakening of the land carbon sink in the late 21st century

Increasing surface temperature could lead to enhanced evaporation, reduced soil moisture availability, and more frequent droughts and heat waves. The spatiotemporal co-occurrence of such effects further drives extreme anomalies in vegetation productivity and net land carbon storage. However, the impacts of climate change on extremes in net biospheric production (NBP) over longer time periods are unknown. Using the percentile threshold on the probability distribution curve of NBP anomalies, we computed negative and positive extremes in NBP. Here we show that due to climate warming, about 88% of global regions will experience a larger magnitude of negative NBP extremes than positive NBP extremes toward the end of 2100, which accelerate the weakening of the land carbon sink. Our analysis indicates the frequency of negative extremes associated with declines in biospheric productivity was larger than positive extremes, especially in the tropics. While the overall impact of warming at high latitudes is expected to increase plant productivity and carbon uptake, high-temperature anomalies increasingly induce negative NBP extremes toward the end of the 21st century. Using regression analysis, we found soil moisture anomalies to be the most dominant individual driver of NBP extremes. The compound effect of hotness, dryness, and fire caused extremes at more than 50% of the total grid cells. The larger proportion of negative NBP extremes raises a concern about whether the Earth is capable of increasing vegetation production with a growing human population and rising demand for plant material for food, fiber, fuel, and building materials. The increasing proportion of negative NBP extremes highlights the consequences not only of reduction in total carbon uptake capacity but also of conversion of land to a carbon source.

54 ENVIRONMENTAL SCIENCES↗

Energy Systems Integration Facility (ESIF): World-Class Systems Integration Capabilities and Research

The Energy Systems Integration Facility (ESIF), located at the National Renewable Energy Laboratory (NREL) South Table Mountain campus, is a world-renowned user facility for research and development of modern, advanced, and clean energy technologies. ESIF is distinguished by its continuously evolving, highly integrated systems that span throughout the building, connecting research capabilities across multiple laboratories and test areas. The primary ESIF research systems include: [1] data, cyber, and control networks, [2] research electrical distribution buses (REDB), [3] thermal integration infrastructure, and [4] hydrogen systems. The data, cyber, and control networks provide monitoring, control, communication, automation, visualization, and time series data storage and tagging capabilities for research projects and ESIF systems, including facility safety functions. The REDB system consists of four dedicated AC and DC electrical power networks that can connect devices located across the facility through versatile, automatic circuit configuration to support complex power electronics experiments up to the megawatt-scale. The thermal integration infrastructure consists of three temperature-conditioned water loops that provide heating and cooling interfaces and capabilities for thermal energy research. The hydrogen systems provide megawatt-scale hydrogen production, drying, compression, high-pressure storage, and delivery to laboratory end uses, including hydrogen fuel cell vehicle fueling. The ESIF research systems interconnect and extend throughout the various lab areas of the facility to create elaborate networks composed of diverse technologies for cutting-edge research. The ESIF capabilities are operated and stewarded by the ESIF Research Operations group, who also actively upgrade and advance the systems to ensure they remain ahead of anticipated research - enabling the success of many pioneering energy integration projects. The poster, created by members of the ESIF Research Operations team, highlights and summarizes the four core integrated systems at ESIF. The poster was first presented at the internal NREL Energize Forum on May 13th, 2024, and received the "Best Poster" award.

capabilities↗

Valuation of Distributed Wind in an Isolated System

Remote communities are increasingly adopting renewable energy, such as wind, as they transition away from diesel energy generation. It is important to understand the benefits and costs of wind energy to isolated systems so that decision-makers can optimize their choices in these communities. There are few examples of valuation of wind energy as a distributed resource and numerous differences in valuation approaches, especially in the inclusion of environmental and economic impacts. We apply a distributed wind valuation framework to calculate the benefits and costs of wind in St. Mary’s, Alaska, to the local electric cooperative and to society, finding that the project does not have a favorable benefit-to-cost ratio unless societal benefits are included, in which case the benefit-to-cost ratio is nearly double. Government funding is important to reducing the initial capital expenditures of this wind project and will likely be the case for projects with similar characteristics. Additional fuel savings benefits are potentially possible for this project through technological additions such as energy storage and advanced controls.

17 WIND ENERGY↗

Fine Root and Soil Organic Carbon Depth Distributions are Inversely Related Across Fertility and Rainfall Gradients in Lowland Tropical Forests

Humid tropical forests contain some of the largest soil organic carbon (SOC) stocks on Earth. Much of this SOC is in subsoil, yet variation in the distribution of SOC through the soil profile remains poorly characterized across tropical forests. We used a correlative approach to quantify relationships among depth distributions of SOC, fine root biomass, nutrients and texture to 1 m depths across 43 lowland tropical forests in Panama. The sites span rainfall and soil fertility gradients, and these are largely uncorrelated for these sites. We used fitted b parameters to characterize depth distributions, where b is a numerical index based on an asymptotic relationship, such that larger b values indicate greater concentrations of root biomass or SOC at depth in the profile. Root b values ranged from 0.82 to 0.95 and were best predicted by soil pH and extractable potassium (K) stocks. For example, the three most acidic (pH < 4) and Kpoor (< 20 g K m -2 ) soils contained 76 ± 5% of fine root biomass from 0 to 10 cm depth, while the three least acidic (pH > 6.0) and most K-rich (> 50 g K m -2 ) soils contained only 41 ± 9% of fine root biomass at this depth. Root b and SOC b values were inversely related, such that a large fine root biomass in surface soils corresponded to large SOC stocks in subsoils (50–100 cm). SOC b values were best predicted by soil pH and base cation stocks, with the three most base-poor soils containing 34 ± 8% of SOC from 50 to 100 cm depth, and the three most base-rich soils containing just 9 ± 2% of SOC at this depth. Nutrient depth distributions were not related to Root b or SOC b values. Here, these data show that large surface root biomass stocks are associated with large subsoil C stocks in strongly weathered tropical soils. Further studies are required to evaluate why this occurs, and whether changes in surface root biomass, as may occur with global change, could in turn influence SOC storage in tropical forest subsoils.

54 ENVIRONMENTAL SCIENCES↗

Hydrogen Dispersion Modeling for Development of Smart Distributed Monitoring

Studying hydrogen dispersion is crucial for ensuring the safe and effective deployment of hydrogen as an energy carrier. This study presents a comprehensive CFD modeling framework for simulating hydrogen dispersion at a real-world hydrogen production, storage, and utilization facility. Utilizing the Hydrogen Research Facility under the Advanced Research on Integrated Energy Systems (ARIES) at the National Renewable Energy Laboratory's (NREL) Flatirons campus, controlled hydrogen releases at 27 kg-H2/hr were simulated. The model incorporated site-specific atmospheric conditions, including hourly wind speeds and temperatures recorded between 8 AM and 8 PM from October to December 2023. To reduce computational demands, a statistical reduction technique was applied to condense the dataset to 100 representative scenarios, validated by statistical tests for wind speeds and power law coefficients. Simulations were conducted using the Reynolds-Averaged Navier-Stokes equations. Results demonstrated that wind speed substantially influences hydrogen dispersion, with low wind conditions forming concentrated clouds and higher wind speeds stretching the plume. Additionally, clustering analysis informed optimal sensor placement at various elevations with up to 10 sensor locations on each elevation. This framework offers a robust approach for understanding hydrogen behavior in ambient conditions and informing detection strategies.

08 HYDROGEN↗

Data-Driven Multi-agent Deep Reinforcement Learning for Distribution System Decentralized Voltage Control with High Penetration of PVs

This paper proposes a novel model-free/data-driven centralized training and decentralized execution multi-agent deep reinforcement learning (MADRL) framework for distribution system voltage control with high penetration of PVs. The proposed MADRL can coordinate both the real and reactive power control of PVs with existing static var compensators and battery storage systems. Unlike the existing DRL-based voltage control methods, our proposed method does not rely on a system model during both the training and execution stages. This is achieved by developing a new interaction scheme between the surrogate modeling of the original system and the multi-agent soft actor critic (MASAC) MADRL algorithm. In particular, the sparse pseudo-Gaussian process with a few-shots of measurements is utilized to construct the surrogate model of the original environment, i.e., power flow model. This is a data-driven process and no model parameters are needed. Furthermore, the MASAC enabled MADRL allows to achieve better scalability by dividing the original system into different voltage control regions with the aid of real and reactive power sensitivities to voltage, where each region is treated as an agent. This also serves as the foundation for the centralized training and decentralized execution, thus significantly reducing the communication requirements as only local measurements are required for control. Comparative results with other alternatives on the IEEE 123-nodes and 342-nodes systems demonstrate the superiority of the proposed method.

14 SOLAR ENERGY↗

High-resolution Compton spectroscopy using x-ray microcalorimeters

X-ray Compton spectroscopy is one of the few direct probes of the electron momentum distribution of bulk materials in ambient and operando environments. Herein, we report high-resolution inelastic x-ray scattering experiments with high momentum and energy transfer performed at a storage-ring-based high-energy x-ray light source facility using an x-ray transition-edge sensor (TES) microcalorimeter detector. The performance was compared with a silicon drift detector (SDD), an energy-resolving semiconductor detector, and Compton profiles were measured for lithium and cobalt oxide powders relevant to lithium-ion battery research. Spectroscopic analysis of the measured Compton profiles demonstrates the high-sensitivity to the low- Z elements and oxidation states. The line shape analysis of the measured Compton profiles in comparison with computed Hartree–Fock profiles is usually limited by the resolution of the semiconductor detector. We have characterized an x-ray TES microcalorimeter detector for high-resolution Compton scattering experiments using a bending magnet source at the Advanced Photon Source with a double crystal monochromator, providing monochromatic photon energies near 27.5 keV. The momentum resolution below 0.16 atomic units (a.u.) was measured, yielding an improvement of more than a factor of 7 over a state-of-the-art SDD for the same scattering geometry. Furthermore, the lineshapes of narrow valence and broad core electron profiles of sealed lithium metal were clearly resolved using an x-ray TES compared to smeared and broadened lineshapes observed when using the SDD. High-resolution Compton scattering using the energy-resolving area detector shown here presents new opportunities for spatial imaging of electron momentum distributions for a wide class of materials with applications ranging from electrochemistry to condensed matter physics.

47 OTHER INSTRUMENTATION↗

Hybrid Energy Management with Real-Time Control of a High-Power EV Charging Site

Decarbonization of transportation systems is driving higher capacity energy storage and faster charging power requirements in electric vehicles (EVs). Given the potential advantages - such as increased efficiency, reduced inverter capacity, and less total cable mass - there is a demand in the industry for more DC distribution for high-power charging (HPC) hubs. However, the cost-effective, adaptive, and robust operation of the DC-coupled HPC hub necessitates a robust site energy management system (SEMS). Validating SEMS operation using a digital twin of an HPC hub in a real-time simulator (RTS) platform is crucial before field deployment. In this study, we propose a hybrid energy management site controller designed to achieve high-level, long-term operational objectives while managing low-level power sharing control between hub assets. We develop a centralized model predictive controller (MPC) to optimize hub operating points and use these points to update the droop parameters of the site energy storage system (ESS). This approach ensures the hub follows an optimal operating point while maintaining the flexibility to respond to load surges. We tested and verified our proposed approach both offline and on a Controller Hardware-in-the-loop (C-HIL) simulation platform integrated with a SEMS framework, demonstrating real-time site operation and validating a cost-effective and robust site controller.

ADVANCED PROPULSION SYSTEMS↗

Commercial PV Inverter IEEE 1547.1 Ride-Through Assessments Using an Automated PHIL Test Platform

As more countries seek solutions to their de-carbonization targets using renewable energy (RE) technologies, interconnection standards and national grid codes for distributed energy resources (DER) are being updated to support higher penetrations of RE and improve grid stability. Common grid-code revisions mandate DER devices, such as solar inverters and energy storage systems, ride-through (RT) voltage and frequency disturbances. This is necessary because as the percentage of generation from DER increases, there is a greater risk power system faults will cause many or all DER to trip, triggering a substantial load-generation imbalance and possible cascading blackout. This paper demonstrates for the first time a methodology to verify commercial DER devices are compliant to new voltage, frequency, and rate of change of frequency (ROCOF) RT requirements established in IEEE Std. 1547-2018. The methodology incorporates a software automation tool, called the SunSpec System Validation Platform (SVP), in combination with a hardware-in-the-loop (HIL) system to execute the IEEE Std. 1547.1-2020 RT test protocols. In this paper, the approach is validated with two commercial photovoltaic inverters, the test results are analyzed for compliance, and improvements to the test procedure are suggested.

14 SOLAR ENERGY↗

Thermal energy grid storage: Liquid containment and pumping above 2000 °C

As the cost of renewable energy falls below fossil fuels, the key barrier to widespread sustainable electricity has become availability on demand. Energy storage can enable dispatchable renewables, but only with drastic cost reductions compared to current battery technologies. One electricity storage concept that could enable these cost reductions stores electricity as sensible heat in an extremely hot liquid (>2000°C) and uses multi-junction photovoltaics (MPV) as a heat engine to convert it back to electricity on demand hours, or days, later. Furthermore, this paper reports the first containment of silicon in a multipart graphite tank above 2000°C, using material grades that are affordable for energy storage at GWh scales. Low cost molded graphite with particle sizes as large as 10 μm successfully contained metallurgical grade silicon, even with as much as twothirds iron by mass for up to 10 hours and temperatures as high as 2300°C, in tanks as large as two gallons.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effects of water-based binders on electrochemical performance of manganese dioxide cathode in mild aqueous zinc batteries

In the majority of rechargeable batteries including lithium ion batteries (LIBs), polyvinylidene fluoride (PVdF) binders are the most commonly used binder for both anode and cathode. However, using PVdF binder requires the organic solvent of N-methyl-2-pyrrolidone (NMP) which is expensive, volatile, combustible, toxic, and has poor recyclability. Therefore, switching to aqueous electrode processing routes with non-toxic binders would provide a great leap forward towards the realization of ideally fully sustainable and environmentally friendly electrochemical energy storage devices. Various water-soluble binders (aqueous binders) were characterized and compared to the performance of conventional PVDF. Our study demonstrates that the electrochemical performance of Zn/MnO2 aqueous batteries is significantly improved by using sodium carboxymethyl cellulose (CMC) binder. Additionally, CMC binders offers desirable adhesion, good wettability, homogeneous material distribution, and strong chemical stability at certain pH levels (3.5~5) without any decomposition for long-cycle life.

25 ENERGY STORAGE↗

Cross-Scale Catalyst Modeling Applied to H 2 Storage and Release via Formic Acid

Here, we propose the Systems-to-Atoms (S2A) modeling framework that integrates the kinetics of reaction chemistry and structural configurations across various length scales with the aim of establishing a versatile template for multiscale modeling of reactive flow problems and to predict the operando activity of catalyst materials. The approach encompasses a microkinetic model to analyze surface reactions on individual facets of catalyst nanoparticles coupled with the computation of average surface reaction rates for catalyst nanoparticles of specific size distributions. Macro-homogeneous surface reaction kinetics are derived as a function of catalyst loading and used as input parameters for the continuum-scale reactor model. The cross-scale framework enables the optimization of catalyst utilization through reactor design and operating strategy. To demonstrate the framework, we studied the storage and release of hydrogen from formic acid, a promising liquid organic hydrogen carrier (LOHC), over Pd, Pt, and Cu catalysts. The framework predicts observed trends in formic acid dehydrogenation activity for catalysts with comparable weight loadings and metal particle diameters, demonstrating satisfactory quantitative alignment. Finally, the seamless transmission of parameter uncertainties between scales is also discussed.

08 HYDROGEN↗

Multi-Functional Distributed Fiber Sensors for Pipeline Monitoring and Methane Detections. Final Report

As an abundant and cheap fossil energy source, natural gas has become a significant energy supply to support the United States’ economy. However, the large-scale extraction and utilization of natural gas also impose significant challenges on methane leakage. This problem is exacerbated by aging gas utility delivery systems, including interstate high-pressure pipelines, storage, and transmission facilities. This project aims to develop a cost-effective fiber optical sensing method that can perform multi-parameter real-time measurements of natural gas pipelines across long interrogation distances up to 100 km with 1-meter spatial resolution. This sensing tool can evaluate overall pipeline efficiency and reduce methane emissions for mid-stream methane infrastructures. To accomplish this objective, research and development efforts funded by this project have resulted in the following accomplishments: This project successfully has developed new functional sensory polymer materials using Metal-Organic Frameworks (MOFs) that can be coated on optical fiber through the reel-to-reel coating process. Functional polymer-coated optical fibers can perform sensitive methane detection through evanescence wave interaction and strain-based measurements to achieve 1% detection sensitivities. The new sensors fibers support both distributed measurements and multiplexed fiber sensors array for multi-point measurements. This project developed and optimized a new multi-core optical fiber that supports simultaneous and distributed measurements of strain and temperatures with 1-meter spatial resolutions across up to 100-km interrogation distance. This new fiber, combined with sensory polymercoated fiber, could perform both distributed temperature and methane detections. This project developed a new artificial intelligence big data algorithm approach that can effectively analyze high-resolution data harnessed by distributed fiber sensors to protect natural gas pipelines against external threats and detect internal defects induced by corrosion. Working with our industry partner, this project developed new optical fibers that support fiber sensor fabrications through polymer coating after the fibers are drawn. These new fibers eliminate the need for direct sensor fabrication when the fiber is fabricated on a fiber draw tower, which drastically expands fiber sensors' applicability. This research project has significantly advanced the distributed fiber sensing technology. It will dramatically increase the applicability and adaptability of distributed fiber sensors for a wide array of applications in energy, sustainability, and environmental science, including structural health monitoring of natural gas pipelines, oil infrastructures, hydrogen facilities, and environmental monitoring of carbon storage sites, water supply systems, and others.

03 NATURAL GAS↗

Statistical Properties of Undulator Radiation

Two experiments were carried out to study the statistical properties of undulator radiation in the Integrable Optics Test Accelerator (IOTA) storage ring at Fermilab. The first experiment studied the turn-to-turn fluctuations in the power of the radiation generated by an electron bunch. The magnitude of these fluctuations depends on the 6D phase-space distribution of the electron bunch. In IOTA, we demonstrated that this effect can be used to measure some electron bunch parameters, small transverse emittances in particular. In the second experiment, a single electron was stored in the ring, emitting a photon only once per several hundred turns. In this regime, any classical interference-related collective effects were eliminated, and the quantum fluctuations could be studied in detail to search for possible deviations from the expected Poissonian photon statistics. In addition, the photocount arrival times were used to track the longitudinal motion of a single electron and to compare it with simulations. This allowed us to determine several dynamical parameters of the storage ring such as the rf cavity phase jitter and the dependence of the synchrotron motion period on amplitude.

43 PARTICLE ACCELERATORS↗

Optimizing design and dispatch of a resilient renewable energy microgrid for a South African hospital

Lack of access to reliable energy is a major concern for countries in sub-Saharan Africa. The national grids are unable to consistently satisfy demand. Therefore, users turn to distributed generation systems in the form of back-up generators. However, such systems are usually designed based on a rule of thumb. We employ a mixed-integer linear programming model that considers several options such as renewable energy, combined heat and power, and storage technologies, in addition to those on-site, to provide optimal design and dispatch decisions that minimize total cost. We apply this model to a case study for a hospital in South Africa, considering its need for reliable electricity in light of multiple outages that might occur over the course of a year, as well as its high heating and cooling loads. Our results show that optimal design and dispatch decisions for the distributed generation system address reliability challenges, regardless of the time at which they occur. And, these solutions yield millions of dollars in savings, suggesting that technologies such as the absorption chiller may be overlooked in typical designs; its integration can reduce demand charges even in the absence of combined heat and power. We show that total cost is most sensitive to changes in site electrical demand, followed by capital cost, fuel cost, photovoltaic production, and monthly demand charges; changes in fuel cost primarily affect system sizes of combined heat and power and the absorption chiller, while photovoltaic system size is more sensitive to the changes in capital and fuel costs, photovoltaic resource availability, and hourly electrical demand. Finally, an outage simulator demonstrates the ability of our optimized system to sustain with no interruptions in power five-hour outages with probability 1.0 and ten-hour outages with probability 0.65, significant improvements over 0.5 and 0.0, respectively, under a business-as-usual case.

24 POWER TRANSMISSION AND DISTRIBUTION↗