Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “digital image correlation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

The relationship between anatomic noise and volumetric breast density for digital mammography

Purpose: The appearance of parenchymal/stromal patterns in mammography have been characterized as having a Wiener power spectrum with an inverse power-law shape described by the exponential parameter, {beta}. The amount of fibroglandular tissue, which can be quantified in terms of volumetric breast density (VBD), influences the texture and appearance of the patterns formed in a mammogram. Here, a large study is performed to investigate the variations in {beta} in a clinical population and to indicate the relationship between {beta} and breast density. Methods: From a set of 2686 cranio-caudal normal screening mammograms, the parameter {beta} was extracted from log-log fits to the Wiener spectrum over the range 0.15-1 mm{sup -1}. The Wiener spectrum was calculated from regions of interest in the compression paddle contact region of the breast. An in-house computer program, Cumulus V, was used to extract the volumetric breast density and identify the compression paddle contact regions of the breast. The Wiener spectra were calculated with and without modulation transfer function (MTF) correction to determine the impact of VBD on the intrinsic anatomic noise. Results: The mean volumetric breast density was 25.5% ({+-}12.6%) over all images. The mean {beta} following a MTF correction which decreased the {beta} slightly ( Almost-Equal-To -0.08) was found to be 2.87. Varying the maximum of the spatial frequency range of the fits from 0.7 to 1.0, 1.25 or 1.5 mm{sup -1} showing small decreases in the result, although the effect of the quantum noise power component on reducing {beta} was clearly observed at 1.5 mm{sup -1}. Conclusions: The texture parameter, {beta}, was found to increase with VBD at low volumetric breast densities with an apparent leveling off at higher densities. The relationship between {beta} and VBD measured here can be used to create probabilistic models for computer simulations of detectability. As breast density is a known risk predictor for breast cancer, the correlation between {beta} and VBD suggests that {beta} may provide predictive information and this will be investigated in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

POLYCYCLIC AROMATIC HYDROCARBONS IN GALAXIES AT z approx 0.1: THE EFFECT OF STAR FORMATION AND ACTIVE GALACTIC NUCLEI

We present the analysis of the polycyclic aromatic hydrocarbon (PAH) spectra of a sample of 92 typical star-forming galaxies at 0.03 < z < 0.2 observed with the Spitzer intensified Reticon spectrograph (IRS). We compare the relative strengths of PAH emission features with Sloan Digital Sky Survey optical diagnostics to probe the relationship between PAH grain properties and star formation and active galactic nuclei (AGNs) activity. Short-to-long wavelength PAH ratios, and in particular the 7.7 mum-to-11.3 mum feature ratio, are strongly correlated with the star formation diagnostics D{sub n} (4000) and Halpha equivalent width, increasing with younger stellar populations. This ratio also shows a significant difference between active and non-active galaxies, with the active galaxies exhibiting weaker 7.7 mum emission. A hard radiation field as measured by [O{sub III}]/Hbeta and [Ne{sub III}]{sub 15.6m}u{sub m}/[Ne{sub II}]{sub 12.8m}u{sub m} effects PAH ratios differently depending on whether this field results from starburst activity or an AGN. Our results are consistent with a picture in which larger PAH molecules grow more efficiently in richer media and in which smaller PAH molecules are preferentially destroyed by the AGN.

79 ASTRONOMY AND ASTROPHYSICS↗

LIS Validation at The KSC-ER

Each year, thousands of lightning electric field disturbances are recorded and archived by the ground-based field mill (FM) network at the NASA Kennedy Space Center (KSC) and USAF Eastern Range (ER). The FM network has a range of several tens of kilometers, and a digital accuracy of 4 V/m. It has provided years of continuous lightning warning surveillance to KSC-ER space vehicle launch operations, and has undergone one major hardware upgrade since its inception in the early 1970s. Additional KSC lightning warning data is derived from a multistation radio time-of-arrival system called Lightning Detection and Ranging (LDAR). This system provides the location and space-time mapping of individual lightning channels (for both cloud and ground flashes). Additional lightning information for the KSC region is available from the National Lightning Detection Network (NLDN) and a 5-station local magnetic direction finder network. In this study, all of the above mentioned data are used to ground-validate data derived from the Lightning Imaging Sensor (LIS) onboard the Tropical Rainfall Measuring Mission (TRMM). The FM network can be used to retrieve the charges deposited in a lightning flash, provided the flash is within a few kilometers of the FM Network. Although it is rare to obtain a TRMM overpass of thunderstorms hat occur this close to the FM network, seven such storms have been found and examined in this study. We compare the times and locations of LIS optical pulses with the spatial-temporal character of the FM, LDAR, and magnetic direction finder data. We also inter-compare LIS optical pulse amplitude data with FM-derived charge magnitudes, number of LDAR radio sources, and peak current values from magnetic direction finder data. Generally speaking, LIS lightning locations and times agree favorably with the KSC ground-based systems for most cases, but little correlation appears to exist between optical pulse amplitude and any of charge, # LDAR sources, peak current), owing possibly to the effects of source complexity and/or cloud multiple scattering.

Koshak, William J.↗

Monitoring system for the quality assessment in additive manufacturing

Additive Manufacturing (AM) refers to a process by which a set of digital data -representing a certain complex 3dim design - is used to grow the respective 3dim real structure equal to the corresponding design. For the powder-based EOS manufacturing process a variety of plastic and metal materials can be used. Thereby, AM is in many aspects a very powerful tool as it can help to overcome particular limitations in conventional manufacturing. AM enables more freedom of design, complex, hollow and/or lightweight structures as well as product individualisation and functional integration. As such it is a promising approach with respect to the future design and manufacturing of complex 3dim structures. On the other hand, it certainly calls for new methods and standards in view of quality assessment. In particular, when utilizing AM for the design of complex parts used in aviation and aerospace technologies, appropriate monitoring systems are mandatory. In this respect, recently, sustainable progress has been accomplished by joining the common efforts and concerns of a manufacturer Additive Manufacturing systems and respective materials (EOS), along with those of an operator of such systems (MTU Aero Engines) and experienced application engineers (Carl Metrology), using decent know how in the field of optical and infrared methods regarding non-destructive-examination (NDE). The newly developed technology is best described by a high-resolution layer by layer inspection technique, which allows for a 3D tomography-analysis of the complex part at any time during the manufacturing process. Thereby, inspection costs are kept rather low by using smart image-processing methods as well as CMOS sensors instead of infrared detectors. Moreover, results from conventional physical metallurgy may easily be correlated with the predictive results of the monitoring system which not only allows for improvements of the AM monitoring system, but finally leads to an optimisation of the quality and insurance of material security of the complex structure being manufactured. Both, our poster and our oral presentation will explain the data flow between the above mentioned parties involved. A suitable monitoring system for Additive Manufacturing will be introduced, along with a presentation of the respective high resolution data acquisition, as well as the image processing and the data analysis allowing for a precise control of the 3dim growth-process.

36 MATERIALS SCIENCE↗

Tracker: Image-Processing and Object-Tracking System Developed

Tracker is an object-tracking and image-processing program designed and developed at the NASA Lewis Research Center to help with the analysis of images generated by microgravity combustion and fluid physics experiments. Experiments are often recorded on film or videotape for analysis later. Tracker automates the process of examining each frame of the recorded experiment, performing image-processing operations to bring out the desired detail, and recording the positions of the objects of interest. It can load sequences of images from disk files or acquire images (via a frame grabber) from film transports, videotape, laser disks, or a live camera. Tracker controls the image source to automatically advance to the next frame. It can employ a large array of image-processing operations to enhance the detail of the acquired images and can analyze an arbitrarily large number of objects simultaneously. Several different tracking algorithms are available, including conventional threshold and correlation-based techniques, and more esoteric procedures such as "snake" tracking and automated recognition of character data in the image. The Tracker software was written to be operated by researchers, thus every attempt was made to make the software as user friendly and self-explanatory as possible. Tracker is used by most of the microgravity combustion and fluid physics experiments performed by Lewis, and by visiting researchers. This includes experiments performed on the space shuttles, Mir, sounding rockets, zero-g research airplanes, drop towers, and ground-based laboratories. This software automates the analysis of the flame or liquid s physical parameters such as position, velocity, acceleration, size, shape, intensity characteristics, color, and centroid, as well as a number of other measurements. It can perform these operations on multiple objects simultaneously. Another key feature of Tracker is that it performs optical character recognition (OCR). This feature is useful in extracting numerical instrumentation data that are embedded in images. All the results are saved in files for further data reduction and graphing. There are currently three Tracking Systems (workstations) operating near the laboratories and offices of Lewis Microgravity Science Division researchers. These systems are used independently by students, scientists, and university-based principal investigators. The researchers bring their tapes or films to the workstation and perform the tracking analysis. The resultant data files generated by the tracking process can then be analyzed on the spot, although most of the time researchers prefer to transfer them via the network to their offices for further analysis or plotting. In addition, many researchers have installed Tracker on computers in their office for desktop analysis of digital image sequences, which can be digitized by the Tracking System or some other means. Tracker has not only provided a capability to efficiently and automatically analyze large volumes of data, saving many hours of tedious work, but has also provided new capabilities to extract valuable information and phenomena that was heretofore undetected and unexploited.

Klimek, Robert B.↗

Quantitative Assessment of Breast Cosmetic Outcome After Whole-Breast Irradiation

Purpose: To measure, by quantitative analysis of digital photographs, breast cosmetic outcome within the setting of a randomized trial of conventionally fractionated (CF) and hypofractionated (HF) whole-breast irradiation (WBI), to identify how quantitative cosmesis metrics were associated with patient- and physician-reported cosmesis and whether they differed by treatment arm. Methods and Materials: From 2011 to 2014, 287 women aged ≥40 with ductal carcinoma in situ or early invasive breast cancer were randomized to HF-WBI (42.56 Gy/16 fractions [fx] + 10-12.5 Gy/4-5 fx boost) or CF-WBI (50 Gy/25 fx + 10-14 Gy/5-7 fx). At 1 year after treatment we collected digital photographs, patient-reported cosmesis using the Breast Cancer Treatment and Outcomes Scale, and physician-reported cosmesis using the Radiation Therapy Oncology Group scale. Six quantitative measures of breast symmetry, labeled M1-M6, were calculated from anteroposterior digital photographs. For each measure, values closer to 1 imply greater symmetry, and values closer to 0 imply greater asymmetry. Associations between M1-M6 and patient- and physician-reported cosmesis and treatment arm were evaluated using the Kruskal-Wallis test. Results: Among 245 evaluable patients, patient-reported cosmesis was strongly associated with M1 (vertical symmetry measure) (P<.01). Physician-reported cosmesis was similarly correlated with M1 (P<.01) and also with M2 (vertical symmetry, P=.01) and M4 (horizontal symmetry, P=.03). At 1 year after treatment, HF-WBI resulted in better values of M2 (P=.02) and M3 (P<.01) than CF-WBI; treatment arm was not significantly associated with M1, M4, M5, or M6 (P≥.12). Conclusions: Quantitative assessment of breast photographs reveals similar to improved cosmetic outcome with HF-WBI compared with CF-WBI 1 year after treatment. Assessing cosmetic outcome using these measures could be useful for future comparative effectiveness studies and outcome reporting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accuracy and Consistency of Respiratory Gating in Abdominal Cancer Patients

Purpose: To evaluate respiratory gating accuracy and intrafractional consistency for abdominal cancer patients treated with respiratory gated treatment on a regular linear accelerator system. Methods and Materials: Twelve abdominal patients implanted with fiducials were treated with amplitude-based respiratory-gated radiation therapy. On the basis of daily orthogonal fluoroscopy, the operator readjusted the couch position and gating window such that the fiducial was within a setup margin (fiducial-planning target volume [f-PTV]) when RPM indicated “beam-ON.” Fifty-five pre- and post-treatment fluoroscopic movie pairs with synchronized respiratory gating signal were recorded. Fiducial motion traces were extracted from the fluoroscopic movies using a template matching algorithm and correlated with f-PTV by registering the digitally reconstructed radiographs with the fluoroscopic movies. Treatment was determined to be “accurate” if 50% of the fiducial area stayed within f-PTV while beam-ON. For movie pairs that lost gating accuracy, a MATLAB program was used to assess whether the gating window was optimized, the external-internal correlation (EIC) changed, or the patient moved between movies. A series of safety margins from 0.5 mm to 3 mm was added to f-PTV for reassessing gating accuracy. Results: A decrease in gating accuracy was observed in 44% of movie pairs from daily fluoroscopic movies of 12 abdominal patients. Three main causes for inaccurate gating were identified as change of global EIC over time (∼43%), suboptimal gating setup (∼37%), and imperfect EIC within movie (∼13%). Conclusions: Inconsistent respiratory gating accuracy may occur within 1 treatment session even with a daily adjusted gating window. To improve or maintain gating accuracy during treatment, we suggest using at least a 2.5-mm safety margin to account for gating and setup uncertainties.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Structural Anomalies Detected in Ceramic Matrix Composites Using Combined Nondestructive Evaluation and Finite Element Analysis (NDE and FEA)

Most reverse engineering approaches involve imaging or digitizing an object and then creating a computerized reconstruction that can be integrated, in three dimensions, into a particular design environment. The rapid prototyping technique builds high-quality physical prototypes directly from computer-aided design files. This fundamental technique for interpreting and interacting with large data sets is being used here via Velocity2 (an integrated image-processing software, ref. 1) using computed tomography (CT) data to produce a prototype three-dimensional test specimen model for analyses. A study at the NASA Glenn Research Center proposes to use these capabilities to conduct a combined nondestructive evaluation (NDE) and finite element analysis (FEA) to screen pretest and posttest structural anomalies in structural components. A tensile specimen made of silicon nitrite (Si3N4) ceramic matrix composite was considered to evaluate structural durability and deformity. Ceramic matrix composites are being sought as candidate materials to replace nickel-base superalloys for turbine engine applications. They have the unique characteristics of being able to withstand higher operating temperatures and harsh combustion environments. In addition, their low densities relative to metals help reduce component mass (ref. 2). Detailed three-dimensional volume rendering of the tensile test specimen was successfully carried out with Velocity2 (ref. 1) using two-dimensional images that were generated via computed tomography. Subsequent, three-dimensional finite element analyses were performed, and the results obtained were compared with those predicted by NDE-based calculations and experimental tests. It was shown that Velocity2 software can be used to render a three-dimensional object from a series of CT scan images with a minimum level of complexity. The analytical results (ref. 3) show that the high-stress regions correlated well with the damage sites identified by the CT scans and the experimental data. Furthermore, modeling of the voids collected via NDE offered an analytical advantage that resulted in more accurate assessments of the material s structural strength. The top figure shows a CT scan image of the specimen test section illustrating various hidden structural entities in the material and an optical image of the test specimen considered in this study. The bottom figure represents the stress response predicted from the finite element analyses (ref .3 ) for a selected CT slice where it clearly illustrates the correspondence of the high stress risers due to voids in the material with those predicted by the NDE. This study is continuing, and efforts are concentrated on improving the modeling capabilities to imitate the structural anomalies as detected.

Abdul-Aziz, Ali↗

THE LOCAL HOSTS OF TYPE Ia SUPERNOVAE

We use multi-wavelength, matched aperture, integrated photometry from the Galaxy Evolution Explorer (GALEX), the Sloan Digital Sky Survey, and the RC3 to estimate the physical properties of 166 nearby galaxies hosting 168 well-observed Type Ia supernovae (SNe Ia). The ultraviolet (UV) imaging of local SN Ia hosts from GALEX allows a direct comparison with higher-redshift hosts measured at optical wavelengths that correspond to the rest-frame UV. Our data corroborate well-known features that have been seen in other SN Ia samples. Specifically, hosts with active star formation produce brighter and slower SNe Ia on average, and hosts with luminosity-weighted ages older than 1 Gyr produce on average more faint, fast, and fewer bright, slow SNe Ia than younger hosts. New results include that in our sample, the faintest and fastest SNe Ia occur only in galaxies exceeding a stellar mass threshold of approx10{sup 10} M{sub sun}, leading us to conclude that their progenitors must arise in populations that are older and/or more metal rich than the general SN Ia population. A low host extinction subsample hints at a residual trend in peak luminosity with host age, after correcting for light-curve shape, giving the appearance that older hosts produce less-extincted SNe Ia on average. This has implications for cosmological fitting of SNe Ia, and suggests that host age could be useful as a parameter in the fitting. Converting host mass to metallicity and computing {sup 56}Ni mass from the supernova light curves, we find that our local sample is consistent with a model that predicts a shallow trend between stellar metallicity and the {sup 56}Ni mass that powers the explosion, but we cannot rule out the absence of a trend. We measure a correlation between {sup 56}Ni mass and host age in the local universe that is shallower and not as significant as that seen at higher redshifts. The details of the age-{sup 56}Ni mass correlations at low and higher redshift imply a luminosity-weighted age threshold of approx3 Gyr for SN Ia hosts, above which they are less likely to produce SNe Ia with {sup 56}Ni masses above approx0.5 M{sub sun}.

79 ASTRONOMY AND ASTROPHYSICS↗

Sloan Digital Sky Survey III photometric quasar clustering: Probing the initial conditions of the Universe

Here, the Sloan Digital Sky Survey has surveyed 14,555 square degrees of the sky, and delivered over a trillion pixels of imaging data. We present the large-scale clustering of 1.6 million quasars between z=0.5 and z=2.5 that have been classified from this imaging, representing the highest density of quasars ever studied for clustering measurements. This data set spans 0~ 11,00 square degrees and probes a volume of 80 h –3 Gpc 3 . In principle, such a large volume and medium density of tracers should facilitate high-precision cosmological constraints. We measure the angular clustering of photometrically classified quasars using an optimal quadratic estimator in four redshift slices with an accuracy of ~ 25% over a bin width of δ l ~ 10–15 on scales corresponding to matter-radiation equality and larger (0ℓ ~ 2–3).

79 ASTRONOMY AND ASTROPHYSICS↗

Hierarchical reconstruction of 3D well-connected porous media from 2D exemplars using statistics-informed neural network

The relationships between porous microstructures and transport properties are of fundamental importance in various scientific and engineering applications. Due to the intricacy, stochasticity and heterogeneity of porous media, reliable characterization and modeling of transport properties often require a complete dataset of internal microstructure samples. However, it is often an unbearable cost to acquire sufficient 3D digital microstructures by purely using microscopic imaging systems. Herein this paper presents a machine learning-based technique to hierarchically reconstruct 3D well-connected porous microstructures from one isotropic or several anisotropic low-cost 2D exemplar(s). To compactly characterize the large-scale microstructural features, a Gaussian image pyramid is built for each 2D exemplar. Local morphology patterns are collected from the Gaussian image pyramids, and then they serve as the training data to embed the 2D morphological statistics into feed-forward neural networks at multiple length levels. By using a specially-developed morphology integration scheme, the 3D morphological statistics at different levels can be inferred from the statistics-informed neural networks. Gibbs sampling is adopted to hierarchically reconstruct 3D microstructures by using multi-level 3D morphological statistics, where the large-scale, regional and local morphological patterns are statistically generated and successively added to the same 3D random field. The proposed method is tested on a series of porous media with distinct morphologies, and the statistical equivalence between the reconstructed and the real microstructures is systematically evaluated by comparing morphological descriptors and transport properties. The results demonstrate that the proposed 2D-to-3D microstructure reconstruction method is a universal and efficient approach to generating morphologically and physically realistic samples of porous media.

42 ENGINEERING↗

CubeSat constellations provide enhanced crop phenology and digital agricultural insights using daily leaf area index retrievals

Satellite remote sensing has great potential to deliver on the promise of a data-driven agricultural revolution, with emerging space-based platforms providing spatiotemporal insights into precision-level attributes such as crop water use, vegetation health and condition and crop response to management practices. Using a harmonized collection of high-resolution Planet CubeSat, Sentinel-2, Landsat-8 and additional coarser resolution imagery from MODIS and VIIRS, we exploit a multi-satellite data fusion and machine learning approach to deliver a radiometrically calibrated and gap-filled time-series of daily leaf area index (LAI) at an unprecedented spatial resolution of 3 m. The insights available from such high-resolution CubeSat-based LAI data are demonstrated through tracking the growth cycle of a maize crop and identifying observable within-field spatial and temporal variations across key phenological stages. Daily LAI retrievals peaked at the tasseling stage, demonstrating their value for fertilizer and irrigation scheduling. An evaluation of satellite-based retrievals against field-measured LAI data collected from both rain-fed and irrigated fields shows high correlation and captures the spatiotemporal development of intra- and inter-field variations. Novel agricultural insights related to individual vegetative and reproductive growth stages were obtained, showcasing the capacity for new high-resolution CubeSat platforms to deliver actionable intelligence for precision agricultural and related applications.

54 ENVIRONMENTAL SCIENCES↗

SILICON CARBIDE CERAMICS FOR COMPACT HEAT EXCHANGERS

Silicon carbide (SiC) materials are prime candidates for high temperature heat exchangers for next generation nuclear reactors due to their refractory nature and high thermal conductivity at elevated temperatures. This research has focused on demonstrating the potential of liquid silicon infiltration (LSI) for making SiC to achieve this goal. The major advantage of this method over other ceramic processing techniques is the enhanced capability of making high dense, high purity SiC materials in complex net shapes. For successful formation of net shape SiC using LSI techniques, the carbon preform reactivity and pore structure must be controlled to allow the complete infiltration of the porous carbon structure which allows complete conversion of the carbon to SiC. We have established a procedure for achieving desirable carbon properties by using carbon precursors consisting of two readily available high purity organic materials, crystalline cellulose and phenolic resin. Phenolic resin yields a glassy carbon with low chemical reactivity and porosity while the cellulose carbon is highly reactive and porous. By adjusting the ratio of these two materials in the precursor mixtures, the properties of the carbons produced can be controlled. We have identified the most favorable carbon precursor composition to be a cellulose resin mass ratio of 6:4 for LSI formation of SiC. The optimum reaction conditions are a temperature of 1800 C, a pressure of 0.5 Torr of argon, and a time of 120 minutes. The fully dense net shape SiC material produced has a density of 2.96 g cm{sup -3} (about 92% of pure SiC) and a SiC volume fraction of over 0.82. Kinetics of the LSI SiC formation process was studied by optical microscopy and quantitative digital image analysis. This study identified six reaction stages and provided important understanding of the process. Although the thermal conductivity of pure SiC at elevated temperatures is very high, thermal conductivities of most commercial SiC materials are much lower due to phonon scattering by impurities (e.g., sintering aids located at the grain boundaries of these materials). The thermal conductivity of our SiC was determined using the laser flash method and it is 214 W/mK at 373 K and 64 W/mK at 1273 K. These values are very close to those of pure SiC and are much higher than those of SiC materials made by industrial processes. This SiC made by our LSI process meets the thermal properties required for use in high temperature heat exchanger. Cellulose and phenolic resin carbons lack the well-defined atomic structures associated with common carbon allotropes. Atomic-scale structure was studied using high resolution transmission electron microscopy (HRTEM), nitrogen gas adsorption and helium gas pycnometry. These studies revealed that cellulose carbon exhibits a very high degree of atomic disorder and angstrom-scale porosity. It has a density of only 93% of that of pure graphite, with primarily sp2 bonding character and a low concentration of graphene clusters. Phenolic resin carbon shows more structural order and substantially less angstrom-scale porosity. Its density is 98% of that of pure graphite, and Fourier transform analysis of its TEM micrographs has revealed high concentrations of sp3 diamond and sp2 graphene nano-clusters. This is the first time that diamond nano-clusters have been observed in carbons produced from phenolic resin. AC and DC electrical measurements were made to follow the thermal conversion of microcrystalline cellulose to carbon. This study identifies five regions of electrical conductivity that can be directly correlated to the chemical decomposition and microstructural evolution during carbonization. In Region I, a decrease in overall AC conductivity occurs due to the initial loss of the polar groups from cellulose molecules. In Region II, the AC conductivity starts to increase with heat treatment temperature due to the formation and growth of conducting carbon clusters. In Region III, a further increase of AC conductivity with increasing heat treatment temperature is observed. In addition, the AC conductivity demonstrates a non-linear frequency dependency due to electron hopping, interfacial polarization, and onset of a percolation threshold. In Region IV, the DC conductivity continues to increase with heat treatment due to the growth and percolation of carbon clusters. Finally in Region V, the DC conductivity reaches a plateau with increasing heat treatment temperature as the system reaches a fully percolated state. Thermophysical properties of carbon materials derived from microcrystalline cellulose have been measured under vacuum and compared with earlier measurements conducted under nitrogen to better understand the influence of porosity, composition, and atmosphere effects. The effective thermal conductivity in vacuum is lower than that observed in nitrogen primarily due to the conductivity of nitrogen gas.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-F-P-06: Moving From Computed Radiography to Digital Radiography: A Collaborative Approach to Improve Image Quality

Purpose: To bring together radiologists, technologists, and physicists to utilize post-processing techniques in digital radiography (DR) in order to optimize image acquisition and improve image quality. Methods: Sub-optimal images acquired on a new General Electric (GE) DR system were flagged for follow-up by radiologists and reviewed by technologists and medical physicists. Various exam types from adult musculoskeletal (n=35), adult chest (n=4), and pediatric (n=7) were chosen for review. 673 total images were reviewed. These images were processed using five customized algorithms provided by GE. An image score sheet was created allowing the radiologist to assign a numeric score to each of the processed images, this allowed for objective comparison to the original images. Each image was scored based on seven properties: 1) overall image look, 2) soft tissue contrast, 3) high contrast, 4) latitude, 5) tissue equalization, 6) edge enhancement, 7) visualization of structures. Additional space allowed for additional comments not captured in scoring categories. Radiologists scored the images from 1 – 10 with 1 being non-diagnostic quality and 10 being superior diagnostic quality. Scores for each custom algorithm for each image set were summed. The algorithm with the highest score for each image set was then set as the default processing. Results: Images placed into the PACS “QC folder” for image processing reasons decreased. Feedback from radiologists was, overall, that image quality for these studies had improved. All default processing for these image types was changed to the new algorithm. Conclusion: This work is an example of the collaboration between radiologists, technologists, and physicists at the University of New Mexico to add value to the radiology department. The significant amount of work required to prepare the processing algorithms, reprocessing and scoring of the images was eagerly taken on by all team members in order to produce better quality images and improve patient care.

60 APPLIED LIFE SCIENCES↗

Petrophysical Analysis and Geographic Information System for San Juan Basin Tight Gas Reservoirs

The primary goal of this project is to increase the availability and ease of access to critical data on the Mesaverde and Dakota tight gas reservoirs of the San Juan Basin. Secondary goals include tuning well log interpretations through integration of core, water chemistry and production analysis data to help identify bypassed pay zones; increased knowledge of permeability ratios and how they affect well drainage and thus infill drilling plans; improved time-depth correlations through regional mapping of sonic logs; and improved understanding of the variability of formation waters within the basin through spatial analysis of water chemistry data. The project will collect, integrate, and analyze a variety of petrophysical and well data concerning the Mesaverde and Dakota reservoirs of the San Juan Basin, with particular emphasis on data available in the areas defined as tight gas areas for purpose of FERC. A relational, geo-referenced database (a geographic information system, or GIS) will be created to archive this data. The information will be analyzed using neural networks, kriging, and other statistical interpolation/extrapolation techniques to fine-tune regional well log interpretations, improve pay zone recognition from old logs or cased-hole logs, determine permeability ratios, and also to analyze water chemistries and compatibilities within the study area. This single-phase project will be accomplished through four major tasks: Data Collection, Data Integration, Data Analysis, and User Interface Design. Data will be extracted from existing databases as well as paper records, then cleaned and integrated into a single GIS database. Once the data warehouse is built, several methods of data analysis will be used both to improve pay zone recognition in single wells, and to extrapolate a variety of petrophysical properties on a regional basis. A user interface will provide tools to make the data and results of the study accessible and useful. The final deliverable for this project will be a web-based GIS providing data, interpretations, and user tools that will be accessible to anyone with Internet access. During this project, the following work has been performed: (1) Assimilation of most special core analysis data into a GIS database; (2) Inventorying of additional data, such as log images or LAS files that may exist for this area; (3) Analysis of geographic distribution of that data to pinpoint regional gaps in coverage; (4) Assessment of the data within both public and proprietary data sets to begin tuning of regional well logging analyses and improve payzone recognition; (5) Development of an integrated web and GIS interface for all the information collected in this effort, including data from northwest New Mexico; (6) Acquisition and digitization of logs to create LAS files for a subset of the wells in the special core analysis data set; and (7) Petrophysical analysis of the final set of well logs.

03 NATURAL GAS↗

Predicting Treatment Response of Colorectal Cancer Liver Metastases to Conventional Lipiodol-Based Transarterial Chemoembolization Using Diffusion-Weighted MR Imaging: Value of Pretreatment Apparent Diffusion Coefficients (ADC) and ADC Changes Under Therapy

PurposeTo use absolute pretreatment apparent diffusion coefficients (ADC) derived from diffusion-weighted MR imaging (DWI) to predict response to repetitive cTACE for unresectable liver metastases of colorectal carcinoma (CRLM) at 1 and 3 months after start of treatment.Materials and MethodsFifty-five metastases in 34 patients were examined with DWI prior to treatment and 1 month after initial cTACE. Treatment was performed in 4-week intervals. Response was evaluated at 1 and 3 months after start of therapy. Metastases showing a decrease of ≥30% in axial diameter were classified as responding lesions.ResultsOne month after initial cTACE, seven lesions showed early response. There was no significant difference in absolute pretreatment ADC values between responding and non-responding lesions (p = 0.94). Three months after initial cTACE, 17 metastases showed response. There was a significant difference (p = 0.021) between absolute pretreatment ADC values of lesions showing response (median 1.08 × 10{sup −3} mm{sup 2}/s) and no response (median 1.30 × 10{sup −3} mm{sup 2}/s). Pretreatment ADC showed fair diagnostic value to predict response (AUC 0.7). Lesions showing response at 3 months also revealed a significant increase in ADC between measurements before treatment and at one month after initial cTACE (p < 0.001). Applying an increase in ADC of 12.17%, response at 3 months after initial cTACE could be predicted with a sensitivity and specificity of 77 and 74%, respectively (AUC 0.817). Furthermore, there was a strong and significant correlation (r = 0.651, p < 0.001) between percentage change in size after third cTACE and percentage change in ADC.ConclusionIn patients with CRLM, ADC measurements are potential biomarkers for assessing response to cTACE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A comparative contrast-detail study of five medical displays

The objective of this study was to compare the contrast-detail performance of five different commercial liquid crystal displays (LCDs) to other LCD and cathode-ray tube (CRT) displays for medical applications. A contrast-detail phantom, supplemented with 5 in. of acrylic, was imaged on a commercial digital radiographic system using techniques comparable to chest radiography. The phantom design enabled observer evaluation by a four-alternative forced choice paradigm. The acquired images were independently scored by five observers on five medical display devices: a 5 megapixel monochrome LCD, a 3 megapixel monochrome LCD, a 9 megapixel color LCD, a 5 megapixel monochrome CRT, and a mammographic-grade monochrome CRT. The data were analyzed using the method suggested by the manufacturer based on a nearest neighbor correction technique. They were further analyzed using a logistic regression response model with a natural threshold using an overall chi-square test for display type followed by pairwise comparisons for individual display performance. The differences between the display devices were small. The standard analysis of the results based on the manufacturer-recommended method did not yield any statistically discernible trend among displays. The logistic regression analysis, however, indicated that the 5 megapixel monochrome LCD was statistically significantly (p<0.0001) superior to the others, followed by the 3 megapixel monochrome LCD (p<0.0001). The three other displays exhibited lower but generally similar performance characteristics. The findings suggest that 5 and 3 megapixel monochrome LCDs provide comparable but subtly superior contrast detectability than other tested displays, with the former performing slightly better in the detection of subtle and fine details.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A digitally reconstructed radiograph algorithm calculated from first principles

Purpose: To develop an algorithm for computing realistic digitally reconstructed radiographs (DRRs) that match real cone-beam CT (CBCT) projections with no artificial adjustments. Methods: The authors used measured attenuation data from cone-beam CT projection radiographs of different materials to obtain a function to convert CT number to linear attenuation coefficient (LAC). The effects of scatter, beam hardening, and veiling glare were first removed from the attenuation data. Using this conversion function the authors calculated the line integral of LAC through a CT along rays connecting the radiation source and detector pixels with a ray-tracing algorithm, producing raw DRRs. The effects of scatter, beam hardening, and veiling glare were then included in the DRRs through postprocessing. Results: The authors compared actual CBCT projections to DRRs produced with all corrections (scatter, beam hardening, and veiling glare) and to uncorrected DRRs. Algorithm accuracy was assessed through visual comparison of projections and DRRs, pixel intensity comparisons, intensity histogram comparisons, and correlation plots of DRR-to-projection pixel intensities. In general, the fully corrected algorithm provided a small but nontrivial improvement in accuracy over the uncorrected algorithm. The authors also investigated both measurement- and computation-based methods for determining the beam hardening correction, and found the computation-based method to be superior, as it accounted for nonuniform bowtie filter thickness. The authors benchmarked the algorithm for speed and found that it produced DRRs in about 0.35 s for full detector and CT resolution at a ray step-size of 0.5 mm. Conclusions: The authors have demonstrated a DRR algorithm calculated from first principles that accounts for scatter, beam hardening, and veiling glare in order to produce accurate DRRs. The algorithm is computationally efficient, making it a good candidate for iterative CT reconstruction techniques that require a data fidelity term based on the matching of DRRs and projections.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗