Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Technique for an improved and time-resolved carbon areal density measurement with a single channel diagnostic for inertial confinement fusion

Measurement of the areal density and velocity of the carbon ablator shell during peak burn in inertial confinement fusion give powerful information on the state of the ablator and where in the trajectory of implosion it reaches peak burn. Detailed comparison of the absolute densities and velocities of the carbon in implosions has been prevented by the limited ability to resolve shot-to-shot variation within a shot series or within a campaign. Here, a new approach using a single, ultra fast (~10 ps) gamma ray channel can massively reduce uncertainties and will provide insights on improvements to target and drive variables. Small improvements in these experimental design parameters may result in much greater yields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Model-driven prediction for accelerator magnet diagnostics to improve operation reliability

Reliability is one of the most critical metrics for accelerator operation, especially in user facilities. To reduce costly facility downtime and provide an operational environment where system performance can be reliably predicted in support of scientific studies, we are developing a model-driven approach for prediction and anomaly detection. Here, in this study, we present the application of a model-driven method that employs a linear regression model to predict the future temperature, in real time, of accelerator magnets at the NSLS-II light source. This approach enables proactive identification of magnet-heating issues, facilitating magnet flushing prior to the occurrence of permanent damage without interrupting machine operation. The implementation of this method in the NSLS-II control room is described and the analysis of the online results is presented. The results demonstrate the model’s effectiveness in providing early alerts to engineers and improving the reliability of accelerator operations.

36 MATERIALS SCIENCE↗

Optimizing aluminum oxide passivation layers—Laser-induced plasmas for layer formation, real-time diagnostics, and layer evaluation

Molten salts have beneficial thermophysical and electrolytic properties, but the aggressive nature of molten salts requires corrosion mitigation strategies, such as structural material surface treatment. In this study, a laser-induced breakdown spectroscopy (LIBS) system was used to simultaneously ablate and monitor de-excitation spectra to form and identify dense alumina passivation layers. Additionally, high-frequency (kHz) LIBS imaging allowed rapid elemental mapping and depth profiling for surface O/Al ratios via minimally destructive analysis. The paired t-test rejected the null hypothesis that air and Ar cover gases were equivalent (p = 0.00012), and the analysis of variance (ANOVA) showed that overlap between shots (p = 0.03112) and cover gas flow rate (p = 0.02729) were statistically significant. At 75% overlap, the O/Al ratio increased to 10% ± 2%, and 90% overlap rose further to 31% ± 2%. Regardless of overlap, tuning the gas flow from 0.5 to 2.5 L min −1 enhanced the O/Al ratio by 24% ± 4%. LIBS depth profiling showed a 3× increase in layer thickness from 75% to 90% overlap. Molecular band peaks of AlO, a precursor to Al 2 O 3 found during treatment, suggest that band intensity could be used for real-time Al 2 O 3 optimization. Ultimately, by adjusting laser spot overlap and cover gas flow rate, a 266 nm laser was shown to form Al 2 O 3 layers on an Al6061 sample, with cover gas flow rate primarily affecting the O/Al ratio and layer thickness correlating with laser spot overlap. This combination of molecular spectra collection, imaging, and depth profiling demonstrated the robust layer analysis capabilities of LIBS.

Corrosion↗

Long-Term Cyclability of NCM-811 at High Voltages in Lithium-Ion Batteries: an In-Depth Diagnostic Study

High-nickel layered oxides, such as LiNi 0.8 Co 0.1 Mn 0.1 O 2 (NCM-811), offer higher energy density than their low-nickel counterparts at a given voltage and are gaining major traction in automotive lithium-ion batteries for electric vehicles. Besides high-Ni content, higher charging voltages above 4.3 V vs Li + /Li boost the energy and represent another focus in battery development. Here, we investigate the long-term cyclability of NCM-811 in graphite pouch cells over 1000 deep cycles between 2.5–4.2, 2.5–4.4, and 2.5–4.5 V through a suite of sensitive characterization techniques. The NCM-811 full cells show severely deteriorated cyclability with higher charging voltages, from 78% at 4.2 V to 52 and 32% at 4.4 and 4.5 V, respectively. At 4.2 V, minor parasitic electrolyte oxidation as well as cathode Li/Ni mixing and cracking are revealed after cycling, while transition-metal dissolution and surface reconstruction into rock-salt NiO are virtually undetectable. At 4.4 and 4.5 V, transition-metal dissolution and crossover to the anode become much more pronounced and a primary contributor to the capacity fade, while significant surface NiO formation causes substantial voltage polarization, which is less noticeable at 4.2 V. Meanwhile, more severe electrolyte oxidation, Li/Ni mixing, and particle pulverization exacerbate the voltage and capacity fade. Finally, these results outline distinct challenges for stable high-Ni layered oxide cathodes in high-voltage Li-ion batteries.

25 ENERGY STORAGE↗

Revealing Hidden Quinones Through Diagnostic MS² Fragmentation of Peptide–Quinone Adducts

Quinones are redox-active components of natural organic matter that mediate electron transfer and influence biogeochemical processes, but many quinones in pyrogenic organic matter (PyOM) remain unresolved because they ionize poorly by mass spectrometry. Here, we present a peptide-tagging approach to improve detection of cysteine-reactive electrophiles in PyOM, with quinones expected to be a dominant subset based on reaction chemistry and selectivity experiments. A cysteine-containing peptide was used to form Michael-addition adducts, enhancing electrospray ionization and enabling untargeted screening by high-performance liquid chromatography-high-resolution tandem mass spectrometry. The method was benchmarked with five quinone standards and applied to extracts from charred plant material as a discovery-level screen for cysteine-reactive targets. We identified 98 quinone-candidate adducts (mean neutral mass ~603 Da), of which more than 70% were not detectable in native MS1 data. Among formula-assigned features, hidden quinone candidates had median (O+N)/C of 0.391 and normalized oxidation state of carbon of -0.281, consistent with relatively low polarity and low oxidation state. These results reveal a previously inaccessible pool of hidden redox-active compounds in PyOM and provide a framework for prioritizing quinone-like electrophiles for confirmation and incorporation into models of fire-driven biogeochemical cycling.

LC-MS/MS↗