Preliminary results of buffet tests in a cryogenic wind tunnel

Buffet tests of two wings with different leading-edge sweep show that it is feasible to use the standards wing root bending moment technique in a cryogenic wing tunnel. The results for the 65 deg sweep delta wing indicate the importance of matching the reduced frequency parameter in model tests for planforms which are sensitive to reduced frequency parameter if quantitative buffet measurements are required. The unique ability of a pressurized cryogenic wind tunnel to separate the effects of Reynolds number and of aeroelastic distortion by variations in the tunnel stagnation temperature and pressure was demonstrated.

Boyden, R. P.↗

Model experience in the Langley 0.3-m transonic cryogenic tunnel

The model building, development, and testing experience gained during 8 years of operation of the 0.3-m Transonic Cryogenic Tunnel (TCT) is summarized. The summary is divided into four portions: (1) models tested in the 0.3-m TCT's original octagonal test section; (2) models tested in the present two dimensional test section; (3) models tested as a part of tunnel calibration and the development of advanced technology airfoils; and (4) development of a new way to construct two dimensional airfoil models. Design requirements imposed on the models by high Reynolds number testing at cryogenic temperatures are reviewed.

Lawing, P. L.↗

Instrumentation for calibration and control of a continuous-flow cryogenic tunnel

Aspects of selection and application of calibration and control instrumentation that are influenced by the extremes in the temperature environment to be found in cryogenic tunnels are described. The instrumentation and data acquisition system used in the 0.3-m transonic cryogenic tunnel along with typical calibration data obtained in a 20 by 60 cm two dimensional test section are described.

Ladson, C. L.↗

Cryogenic fluid management experiment

The cryogenic fluid management experiment (CFME), designed to characterize subcritical liquid hydrogen storage and expulsion in the low-q space environment, is discussed. The experiment utilizes a fine mesh screen fluid management device to accomplish gas-free liquid expulsion and a thermodynamic vent system to intercept heat leak and control tank pressure. The experiment design evolved from a single flight prototype to provision for a multimission (up to 7) capability. A detailed design of the CFME, a dynamic test article, and dedicated ground support equipment were generated. All materials and parts were identified, and components were selected and specifications prepared. Long lead titanium pressurant spheres and the flight tape recorder and ground reproduce unit were procured. Experiment integration with the shuttle orbiter, Spacelab, and KSC ground operations was coordinated with the appropriate NASA centers, and experiment interfaces were defined. Phase 1 ground and flight safety reviews were conducted. Costs were estimated for fabrication and assembly of the CFME, which will become the storage and supply tank for a cryogenic fluid management facility to investigate fluid management in space.

Eberhardt, R. N.↗

Cryogenic Technology, part 1

Different engineering problems associated with the design of mechanisms and systems to operate in a cryogenic environment are discussed. The focal point for the entire engineering effort was the design of the National Transonic Facility, which is a closed-circuit cryogenic wind tunnel. The papers covered a variety of mechanical, structural, and systems design subjects including thermal structures insulation systems, noise, seals, and materials.

Source record↗

The metallurgical structure and mechanical properties at low temperature of Nitronic 40 with particular reference to its use in the construction of models for cryogenic wind tunnels

Nitronic 40 was chosen for the construction of Pathfinder I, an R & D model for use in the National Transonic Facility, because of its good mechanical properties at cryogenic temperatures. Nitronic 40 contains delta ferrite and is in a sensitized condition. Heat treatments carried out to remove residual stresses also caused further sensitization. Experiments showed that heat treatment followed by cryoquenching removed the sensitization without creating residual stresses. Heat treatment at temperatures of 2200 F was used to remove the delta ferrite but with little success and at the cost of massive grain growth. The implications of using degraded Nitronic 40 for cryogenic wind tunnel models are discussed, together with possible acceptance criteria.

Wigley, D. A.↗

Seeing through flows in Langley's 0.3-meter Transonic Cryogenic Tunnel

Viewing problems associated with the measurement of model deformation in cryogenic wind tunnels are discussed. Tests were conducted in the Langley 0.3-Meter Transonic Cryogenic Tunnel to assess viewing capabilities thru the flow field. The effects of condensation and turbulent boundary layers are discussed and a modelling procedure for image degradation is described.

Snow, W. L.↗

Results of buffet tests in a cryogenic wind tunnel

Buffet tests on two semispan wing models with different leading edge sweep show that it is feasibile to use the standard dynamic wing root bending moment technique in a cryogenic wind tunnel. One model was a slender 65 deg swept delta wing with sharp leading edges. The other model was an unswept wing of aspect ratio 1.5 with a British NPL 9510 airfoil section. The results for the 65 deg swept delta wing indicate the importance of matching the reduced frequency parameter in model tests for planforms which are sensitive to reduced frequency parameter if quantitative buffet measurements are required. The unique ability of a pressurized cryogenic wind tunnel to separate the effects of Reynolds number and of static aeroelastic distortion by variations in the tunnel stagnation temperature and pressure were demonstrated.

Boyden, R. P.↗

A cryogenic valve for spacecraft applications

Space-compatible cryogenic valves are now required to operate between room and liquid helium temperatures. A remotely controllable cryogenic valve is described, which is made of bellows-type stainless steel and is operated by a miniature dc motor with integral gearset (485:1) at a nominal voltage of 28 Vdc. The power transmission provides a further reduction of 7.2:1 to give an overall gear ratio of nearly 3500:1, assuring reliability of operation at low temperatures. Valve performance (leak rate) data are presented at LN2, LHe, and SfHe temperatures at delivered torques of 18, 27, 31, and 35 N-m. At a closing torque of 31 N-m, a leak rate of 0.028 scc/sec was achieved at 2 K, while at a torque of 18 N-m the leak rate at 300 K was less than 3 x 10 to the -9th scc/sec.

Salerno, L. J.↗

The cryogenic wind tunnel for high Reynolds number testing

An improved way to increase the Reynolds numbers capability of wind tunnels has been developed at the Langley Research Center. Cooling the test gas to cryogenic temperatures by spraying liquid nitrogen into the tunnel circuit increases Reynolds number with no increase in dynamic pressure and a reduction in drive power. In addition, the ability to vary the temperature of the test gas independently of pressure and Mach number allows for the first time the independent determination of Reynolds number, Mach number, and aeroelastic effects. A new fan-driven transonic cryogenic tunnel being built at the Langley Research Center will provide an order of magnitude increase in Reynolds number capability over existing transonic tunnels in the United States when it is completed later this year.

Kilgore, R. A.↗

Force instrumentation for cryogenic wind tunnels using one-piece strain-gage balances

Materials and techniques for a transducer capable of obtaining accurate force measurements at cryogenic temperatures (down to 77 K) and high pressures (up to 9 atm) have been determined. Areas of high stress concentration are minimized by balance design, and model and sting attachment methods able to withstand cryogenic temperatures are used. Maraging 200 is the material used for the balances, due to its high impact strength and simple heat treatment procedure. Test results verify that the balances produce reliable, repeatable, and predictable data from 300 K to 110 K under steady state conditions. Techniques have been developed to reduce the temperature-induced bridge output, such as the use of bridges with two gages mounted transverse to the principal stress direction. Under these conditions, the results given by the balances should be equally good during transient temperatures on five of the six components. The work will be used at the National Transonic Facility (NTF) at NASA Langley.

Ferris, A. T.↗

Continuous-Reading Cryogen Level Sensor

Two pressure transducers used in system for measuring amount of cryogenic liquid in tank. System provides continuous measurements accurate within 0.03 percent. Sensors determine pressure in liquid and vapor in tank. Microprocessor uses pressure difference to compute mass of cryogenic liquid in tank. New system allows continuous sensing; unaffected by localized variations in composition and density as are capacitance-sensing schemes.

Barone, F. E.↗

Sensitivity analysis of cool-down strategies for a transonic cryogenic tunnel

Guidelines and suggestions substantiated by real-time simulation data to ensure optimum time and energy use of injected liquid nitrogen for cooling the Langley 0.3-Meter Transonic Cryogenic Tunnel (TCT) are presented. It is directed toward enabling operators and researchers to become cognizant of criteria for using the 0.3-m TCT in an energy- or time-efficient manner. Operational recommendations were developed based on information collected from a validated simulator of the 0.3-m TCT and experimental data from the tunnel. Results and trends, however, can be extrapolated to other similarly constructed cryogenic wind tunnels.

Thibodeaux, J. J.↗

Characterization of particles in the Langley 0.3 meter transonic cryogenic tunnel using hot wire anemometry

Hot wire anemometry was used to identify the nature of particles reportedly observed during free stream velocity measurements in the Langley 0.3-meter transonic cryogenic tunnel using a Laser Doppler Velocimeter. Since the heat-transfer process from the hot wire depends on the thermal conductivity and sticking capability of the particles, it was anticipated that the hot wire anemometer response would be affected differently upon impaction by liquid droplets and solid aerosols in the test gas stream. Based on the measured time response of the hot-wire anemometer in the cryogenic tunnel operated in the 0.3-0.8 Mach number range, it is concluded that the particles impacting the hot wire are liquid in nature rather than solid aerosols. It is further surmised that the liquid aerosols are unevaporated liquid nitrogen droplets used for cooling the tunnel test gas.

Singh, J. J.↗

The problem of dimensional instability in airfoil models for cryogenic wind tunnels

The problem of dimensional instability in airfoil models for cryogenic wind tunnels is discussed in terms of the various mechanisms that can be responsible. The interrelationship between metallurgical structure and possible dimensional instability in cryogenic usage is discussed for those steel alloys of most interest for wind tunnel model construction at this time. Other basic mechanisms responsible for setting up residual stress systems are discussed, together with ways in which their magnitude may be reduced by various elevated or low temperature thermal cycles. A standard specimen configuration is proposed for use in experimental investigations into the effects of machining, heat treatment, and other variables that influence the dimensional stability of the materials of interest. A brief classification of various materials in terms of their metallurgical structure and susceptability to dimensional instability is presented.

Wigley, D. A.↗

Image degradation in Langley 0.3-meter transonic cryogenic tunnel

The optical quality of gas in a cryogenic wind tunnel was determined by observing Sayce targets through different pathlengths of the medium. The data were used to determine the square wave response of the test gas. At conditions corresponding to 15 times ambient density, considerable decrease in response to higher spatial frequencies was noted even in the absence of flow. Under flow conditions, vibrations further degraded the response. The results are interpreted in terms of possible photogrammetric approaches to measure model deformation in large cryogenic facilities such as the National Transonic Facility.

Snow, W. L.↗

Engineering and fabrication cost considerations for cryogenic wind tunnel models

Design and fabrication cost drivers for cryogenic transonic wind tunnel models are defined. The major cost factors for wind tunnel models are model complexity, tolerances, surface finishes, materials, material validation, and model inspection. The cryogenic temperatures require the use of materials with relatively high fracture toughness but at the same time high strength. Some of these materials are very difficult to machine, requiring extensive machine hours which can add significantly to the manufacturing costs. Some additional engineering costs are incurred to certify the materials through mechanical tests and nondestructive evaluation techniques, which are not normally required with conventional models. When instrumentation such as accelerometers and electronically scanned pressure modules is required, temperature control of these devices needs to be incorporated into the design, which requires added effort. Additional thermal analyses and subsystem tests may be necessary, which also adds to the design costs. The largest driver to the design costs is potentially the additional static and dynamic analyses required to insure structural integrity of the model and support system.

Boykin, R. M., Jr.↗

Stirling cycle cryogenic cooler

A long lifetime Stirling cycle cryogenic cooler particularly adapted for space applications is described. It consists of a compressor section centrally aligned end to end with an expansion section, and respectively includes a reciprocating compressor piston and displacer radially suspended in interconnecting cylindrical housings by active magnetic bearings and has adjacent reduced clearance regions so as to be in noncontacting relationship therewith and wherein one or more of these regions operate as clearance seals. The piston and displacer are reciprocated in their housings by linear drive motors to vary the volume of respectively adjacent compression and expansion spaces which contain a gaseous working fluid and a thermal regenerator to effect Stirling cycle cryogenic cooling.

Gasser, M. G.↗