Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cooled”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

High-performance subambient radiative cooling enabled by optically selective and thermally insulating polyethylene aerogel

Recent progress in passive radiative cooling technologies has substantially improved cooling performance under direct sunlight. Yet, experimental demonstrations of daytime radiative cooling still severely underperform in comparison with the theoretical potential due to considerable solar absorption and poor thermal insulation at the emitter. In this work, we developed polyethylene aerogel (PEA)—a solar-reflecting (92.2% solar weighted reflectance at 6 mm thick), infrared-transparent (79.9% transmittance between 8 and 13 μm at 6 mm thick), and low-thermal-conductivity ( k PEA = 28 mW/mK) material that can be integrated with existing emitters to address these challenges. Using an experimental setup that includes the custom-fabricated PEA, we demonstrate a daytime ambient temperature cooling power of 96 W/m 2 and passive cooling up to 13°C below ambient temperature around solar noon. This work could greatly improve the performance of existing passive radiative coolers for air conditioning and portable refrigeration applications.

36 MATERIALS SCIENCE↗

Bulk ultrafine grained/nanocrystalline metals via slow cooling

Cooling, nucleation, and phase growth are ubiquitous processes in nature. Effective control of nucleation and phase growth is of significance to yield refined microstructures with enhanced performance for materials. Recent studies reveal that ultrafine grained (UFG)/nanocrystalline metals exhibit extraordinary properties. However, conventional microstructure refinement methods, such as fast cooling and inoculation, have reached certain fundamental limits. It has been considered impossible to fabricate bulk UFG/nanocrystalline metals via slow cooling. Here, we report a new discovery that nanoparticles can refine metal grains to ultrafine/nanoscale by instilling a continuous nucleation and growth control mechanism during slow cooling. The bulk UFG/nanocrystalline metal with nanoparticles also reveals an unprecedented thermal stability. This method overcomes the grain refinement limits and may be extended to any other processes that involve cooling, nucleation, and phase growth for widespread applications.

36 MATERIALS SCIENCE↗

A Data Driven Pre-cooling Framework for Energy Cost Optimization in Commercial Buildings

Commercial buildings consume significant amount of energy. Facility managers are increasingly grappling with the problem of reducing their buildings’ peak power, overall energy consumption and energy bills. In this paper, we first develop an optimization framework – based on a gray box model for zone thermal dynamics – to determine a pre-cooling strategy that simultaneously shifts the peak power to low energy tariff regimes, and reduces both the peak power and overall energy consumption by exploiting the flexibility in a building’s thermal comfort range. We then evaluate the efficacy of the pre-cooling optimization framework by applying it to building management system data, spanning several days, obtained from a large commercial building located in a tropical region of the world. The results from simulations show that optimal pre-cooling reduces peak power by over 50%, energy consumption by up to 30% and energy bills by up to 37%. Next, to enable ease of use of our framework, we also propose a shortest path based heuristic algorithmfor solving the optimization problemand show that it has comparable erformance with the optimal solution. Finally, we describe an application of the proposed optimization framework for developing countries to reduce the dependency on expensive fossil fuels, which are often used as a source for energy backup.We conclude by highlighting our real world deployment of the optimal pre-cooling framework via a software service on the cloud platform of a major provider. Our pre-cooling methodology, based on the gray box optimization framework, incurs no capital expense and relies on data readily available from a building management system, thus enabling facility managers to take informed decisions for improving the energy and cost footprints of their buildings

Vishwanath, Arun↗

Estimation of Melting-Layer Cooling Rate from Dual-Polarization Radar: Spectral Bin Model Simulations

Diabatic cooling from hydrometeor phase changes in the stratiform melting layer is of great interest to both operational forecasters and modelers for its societal and dynamical consequences. Attempts to estimate the melting-layer cooling rate typically rely on either the budgeting of hydrometeor content estimated from reflectivity Z or model-generated lookup tables scaled by the magnitude of Z in the bright band. Recent advances have been made in developing methods to observe the unique polarimetric characteristics of melting snow and the additional microphysical information they may contain. However, to date no work has looked at the thermodynamic information available from the polarimetric radar brightband signature. In this study, a one-dimensional spectral bin model of melting snow and a coupled polarimetric operator are used to study the relation between the polarimetric radar bright band and the melting-layer cooling rate. Simulations using a fixed particle size distribution (PSD) and variable environmental conditions show that the height and thickness of the bright band and the maximum brightband Z and specific differential phase shift [Formula: see text] are all sensitive to the ambient environment, while the differential reflectivity [Formula: see text] is relatively insensitive. Additional simulations of 2700 PSDs based on in situ observations above the melting layer indicate that the maximum Z, [Formula: see text], and [Formula: see text] within the melting layer are poorly correlated with the maximum cooling rate while [Formula: see text] is strongly correlated. Finally, model simulations suggest that, in addition to riming, concurrent changes in aggregation and precipitation intensity and the associated cooling may plausibly cause observed sagging brightband signatures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Coordinated Abrupt Weakening of the Eurasian and North African Monsoons in the 1960s and Links to Extratropical North Atlantic Cooling

Previous modeling and paleoclimate studies have suggested that cooling originating from the extratropical North Atlantic can abruptly weaken the Eurasian and North African monsoons. The climatic signature includes a widespread cooling over the Eurasian and North African continents and an associated increase to surface pressure. It is explored whether such coordinated changes are similarly exhibited in the observed twentieth-century climate, in particular with the well-documented shift of Sahel rainfall during the 1960s. Surface temperature, sea level pressure, and precipitation changes are analyzed using combined principal component analysis (CPCA). The leading mode exhibits a monotonic shift in the 1960s, and the transition is associated with a relative cooling and pressure increase over the interior Eurasia and North Africa, and rainfall reduction over the Sahel, South Asia, and East Asia. The local circulation changes suggest that the rainfall shift results from the regional response of the summer monsoons to these continental- wide changes. A similar CPCA analysis of atmospheric general circulation model (AGCM) simulations forced by twentieth-century-observed forcings shows similar results, suggesting that origins of the climate shift reside in the sea surface temperature changes, specifically over the extratropical North Atlantic. Finally, an AGCM forced with extratropical North Atlantic cooling appears to simulate these climate impacts, at least qualitatively. The result herein shows that the observed climate signature of the 1960s abrupt shift in Eurasian and North African climate is consistent with the influence of the abrupt highlatitudeNorthAtlantic cooling that occurred in the late 1960s.Adefinitive causal relationship remains to be shown, and mechanisms elucidated.

Climate change↗

Cooling flow regime of a plasma thermal quench

A large class of Laboratory, Space, and Astrophysical plasmas is nearly collisionless. When a localized energy or particle sink, for example, in the form of a radiative cooling spot or a black hole, is introduced into such a plasma, it can trigger a plasma thermal collapse, also known as a thermal quench in tokamak fusion. Here we show that the electron thermal conduction in such a nearly collisionless plasma follows the convective energy transport scaling in itself or in its spatial gradient, due to the constraint of ambipolar transport. As a result, a robust cooling flow aggregates mass toward the cooling spot and the thermal collapse of the surrounding plasma takes the form of four propagating fronts that originate from the radiative cooling spot, along the magnetic field line in a magnetized plasma. The slowest one, which is responsible for deep cooling, is a shock front.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Concentrated radiative cooling and its constraint from reciprocity

Concentrated radiative cooling, an analogous concept of the concentrated solar power technology, has the potential of amplifying both the cooling power and the temperature reduction. However, concentrators have not yet been systematically optimized. Moreover, a widely used theoretical approach to analyze such systems has neglected a fundamental constraint from reciprocity, which can lead to an overestimate of cooling performance and unclarified limits of amplification factors. Here we develop a theoretical framework addressing these shortcomings. Modeling suggests the optimized shape and geometric dimensions of concentrators, as well as the limiting cooling power and temperature reduction. Using an electroplated Al 2 O 3 emitter and an optimized conical concentrator, we experimentally amplify the nighttime radiative cooling by 26%.

Dong, Minghao↗

Radiative cooling textiles using industry-standard particle-free nonporous micro-structured fibers

Abstract Thermal radiation is a major dissipative pathway for heat generated by the human body and offers a significant thermoregulation mechanism over a wide range of conditions. We could use this in garment design to enhance personal cooling, which can improve the wearing comfort of garments or even result in energy savings in buildings. At present, however, radiative cooling has received insufficient attention in commercial design and production of textiles for wearable garments. Textiles that efficiently transmit the radiative heat were recently demonstrated, but either do not utilize standard weaving and knitting processes for wearable garments or require substantial process modifications. Here, we demonstrate the design and implementation of large-scale radiative cooling textiles for localized cooling management and enhanced thermal comfort using industry-standard particle-free nonporous micro-structured fibers that are fully compatible with standard textile materials and production methods. The micro-structured fibers, yarns and fabrics are part of a hierarchical photonic structure design that renders the textiles highly infrared transparent (up to > 0.8) while assuring visual opacity (up to 0.99). We design radiative cooling textiles with first-principles electromagnetic methods and fabricate them using commercial textile materials and formation facilities. Our “fabless” approach is confirmed by very good quantitative agreement between design and measurements. The resulting fabrics exhibit wearability properties expected of wearable textiles, and lower skin temperature by ≥ 3 °C compared to conventional textiles, which offers the potential for > 30 % energy savings in buildings and increases wearing comfort by significantly reducing the reliance on latent heat dissipation for thermoregulation.

Catrysse, Peter B.↗

Feasibility of Process Intensification of Water-Gas Shift Reaction Using a Microreactor with Integrated Cooling

Hydrogen is an increasingly attractive low-carbon energy carrier for a variety of stationary and mobile applications. The water-gas shift (WGS) reaction is a key processing step used for large-scale hydrogen production via the steam methane reforming process. However, the thermodynamics and kinetics of the reaction are such that standard two-stage adiabatic reactors used in these systems are large, increasing catalyst volume and cost. To intensify the process and realize the economical distributed production of hydrogen, adiabatic WGS microreactors with integrated cooling directly regulate the reaction temperature via integrated coolant channels to promote higher conversion within a smaller reactor volume. This study investigates the conversion efficiency of a single WGS microchannel operating under such cooling conditions. A COMSOL Multiphysics model is developed and validated with isothermal experimental data from the literature. The model is then used to evaluate improvements in conversion efficiency when the reaction is cooled via a specified wall temperature profile. Lastly, the model is modified to include cooling channels with a secondary fluid that can practically achieve a similar conversion profile as the specified wall temperature profile previously applied. Initial results show that reactor conversion can be significantly increased by the inclusion of appropriate cooling and that there is a potential for the recovery of energy from the reaction stream that can be used for other applications within the overall process.

energy recovery↗

Development of an ERL for Coherent Electron Cooling at the Electron-Ion Collider

The Electron-Ion Collider (EIC) is currently under development of to be built at Brookhaven National Lab and requires cooling during collisions in order to preserve the quality of the hadron beam despite degradation due to intra-beam scattering and beam-beam effect. An Energy Recovery Linac (ERL) is being designed to deliver the necessary electron beam for the Coherent electron Cooling (CeC) of the hadron beam, with an electron bunch charge of 1 nC and an average current of 100 mA; two modes of operation are being developed for 150 and 55 MeV electrons, corresponding to 275 and 100 GeV protons. The injector of this SHC-ERL is shared with the Precooler ERL, which cools lower energy proton beams via bunched-beam cooling, as used in Low Energy RHIC electron Cooling (LEReC). This paper reviews the current state of the design.

Accelerator Physics↗

Beam Test of a Dielectric Loaded High Pressure RF Cavity for Use in Muon Cooling Channels

Bright muon sources require six dimensional cooling to achieve acceptable luminosities. Ionization cooling is the only known method able to do so within the muon lifetime. One proposed cooling channel, the Helical Cooling Channel, utilizes gas filled radio frequency cavities to both mitigate RF breakdown in the presence of strong, external magnetic fields, and provide the cooling medium. Engineering constraints on the diameter of the magnets within which these cavities operate dictate the radius of the cavities be decreased at their nominal operating frequency. To accomplish this, one may load the cavities with a larger dielectric material. A 99.5% alumina ring was inserted in a high pressure RF test cell and subjected to an intense proton beam at the MuCool Test Area at Fermilab. The results of the performance of this dielectric loaded high pressure RF cavity will be presented.

43 PARTICLE ACCELERATORS↗

Multi-Stage Electron Cooling Scheme for JLEIC

JLEIC is the future electron ion collider under design at Jefferson Lab, which will provide a luminosity up to 1034 cm-2s-1. Electron cooling is essential for JLEIC to overcome the intrabeam scattering effect, reduce the ion beam emittance and thus achieve the high luminosity. The cooling time is approximately in proportion to the square of the energy and the 6D emittance. To avoid the difficulty of cooling the ion beam with large emittance at high energy, a multi-stage cooing scheme was designed for JLEIC. The ion beam was cooled at the low energy to reduce the emittance. Then it was ramped up to the collision energy. During the collision, electron cooling is implemented to maintain the emittance and the luminosity. Simulations for proton beam and lead ion beam at various stages are presented in this paper.

Zhang, He↗

JSPEC: A Program for IBS and Electron Cooling Simulation

Intrabeam scattering is an important collective effect that can deteriorate the properties of a high-intensity beam, and electron cooling is a method to mitigate the IBS effect. JSPEC (JLab Simulation Package for Electron Cooling) is an open-source program developed at Jefferson Lab, which simulates the evolution of the ion beam under the IBS and/or the electron cooling effect. JSPEC has been benchmarked with BETACOOL and experimental data. In this report, we will introduce the features of JSPEC, including the friction force calculation, the IBS expansion rate and electron cooling rate calculation, and the beam-dynamic simulations for the electron cooling process; explain how to set up the simulations in JSPEC; and demonstrate the benchmarking results.

Zhang, He↗

DESIGN AND OPTIMIZATION OF AN ERL FOR COOLING EIC HADRON BEAMS

The baseline scheme for hadron beam cooling in the Electron Ion Collider (EIC) calls for Coherent electron Cooling (CeC) of the hadrons with non-magnetized electrons at high energy (150 MeV electrons) and additional cooling via conventional bunched beam cooling using a precooler system. The electron beam parameters for these concepts are at or beyond the current state of the art, with electron bunch charges on the order of 1 nC and average currents on the order of 100 mA and requiring an Energy Recovery Linac (ERL) to produce such beams. Using specifications provided by BNL and JLab, physicists and engineers at Xelera Research are working on a complete design of an ERL system capable of cooling EIC hadrons.

Gulliford, C.↗

Latest Updates on JSPEC - An IBS and Electron Cooling Simulation Program

JSPEC (JLab Simulation Package on Electron Cooling) is an open-source C++ program developed at Jefferson Lab, which simulates the evolution of the ion beam under the influence of both IBS and electron cooling effects. In this paper, we will report the latest updates to JSPEC. Firstly, we have added theoretical and numerical models that simulate the effect of the electron beam dispersion on non-magnetized cooling. Secondly, the cooler can now be treated as an element with length, rather than a thin lens. This change will impact the modelling of the ions and the electrons in the cooling rate calculation for both magnetized and non-magnetized cooling. Numeri-cal results will be provided to demonstrate the perfor-mance of the new models.

Zhang, H.↗

Development of an ERL for Coherent Electron Cooling at the Electron-Ion Collider

The Electron-Ion Collider (EIC) is currently under development to be built at Brookhaven National Lab and requires cooling during collisions in order to mitigate the hadron beam emittance degradation due to intra-beam scattering and beam-beam effects. An Energy Recovery Linac (ERL) is being designed to deliver the necessary electron beam for Coherent electron Cooling (CeC) of the hadron beam, with an electron bunch charge of 1 nC and an average current of 100 mA; two modes of operation are being developed for 150 and 55 MeV electrons, corresponding to 275 and 100 GeV protons. The injector of this Strong Hadron Cooler ERL (SHC-ERL) is shared with the Pre-cooler ERL, which cools lower energy proton beams via bunched beam cooling, as used in the Low Energy RHIC electron Cooling (LEReC). This paper reviews the current state of the design.

Deitrick, K.↗

Electron Ion Collider Strong Hadron Cooling Injector and ERL

Intra-beam Scattering (IBS) and other diffusion mechanisms in the EIC Hadron Storage Ring (HSR) degrade the beam emittances during a store, with growth times of about 2 hours at the nominal proton energies of 275GeV, 100 GeV, and 41 GeV. Strong Hadron Cooling (SHC) can maintain good hadron beam quality and high luminosity during long collision stores. A novel cooling method ’ Coherent electron Cooling (CeC) ’ is chosen as the baseline SHC method, due to its high cooling rates. An Energy Recovery Linac (ERL) is used to deliver an intense high-quality electron beam for cooling. In this paper, we discuss the beam requirements for SHC-CeC and describe the current status of the injector and ERL designs. Two designs of injector and ERL will be presented: one for dedicated SHC and another one for SHC with precooler.

Wang, E.↗

Improvement to Air2Air™ Technology to Reduce Fresh-Water Evaporative Cooling Loss at Coal-Based Thermoelectric Power Plants

This program was undertaken to enhance the manufacturability, constructability, and cost of the Air2Air™ Water Conservation and Plume Abatement Cooling Tower, giving a validated cost basis and capability. Air2Air™ water conservation technology recovers a portion of the traditional cooling tower evaporate. The Condensing Module provides an air-to-air heat exchanger above the wet fill media, extracting the heat from the hot saturated moist air leaving in the cooling tower and condensing water. The rate of evaporate water recovery is typically 10% - 25% annually, depending on the cooling tower location (climate). This program improved the efficiency and cost of the Air2Air™ Water Conservation Cooling Tower capability, and led to the first commercial sale of the product, as described.

20 FOSSIL-FUELED POWER PLANTS↗