Epsilon substituted lysinol derivatives as HIV-1 protease inhibitors
Abstract not provided
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided
Abstract not provided
For over 10 years, various studies have attempted to increase the recovery of DNA from ammunition by modifying the DNA collection, extraction, purification, and amplification procedures, with varying levels of success. This study focused on the “soaking” method of Montpetit & O’Donnell [1] and the “rinse-and-swab" method of Bille et al. [2]. First, testing for the presence of exogenous DNA, 210 boxed cartridges (brass, steel, and nickel-plated) from nine manufacturers were swabbed and DNA was extracted, concentrated, and quantified. Extracts that quantified > 0 ng/µL (44 of 210) were amplified and genotyped with GlobalFiler™. Of those, only one extract yielded two alleles indicating that the manufacturing and packaging of ammunition was virtually DNA free. Next, to obtain a baseline comparison of two DNA collection methods on a non-metallic substrate and identify a suitable number of cells to spot on cartridges, different DNA input amounts of primary human adult epidermal keratinocytes (HEKa) were tested. Thereafter, 300 brass and 300 nickel-plated, cartridges were spotted with HEKa cells containing ~5 ng of DNA, fired or unfired, and processed with either method. Finally, five methods representing hybrids of the soaking and rinse-and-swab methods were tested to determine if variations of those methods could be used to increase DNA yield and recovery. The results show that the soaking method consistently yielded more DNA than the rinse-and-swab method from a non-metallic substrate. However, the comparison study demonstrated that both methods performed comparably for cartridges. On average, the soaking method recovered 0.25 ng of DNA (5.1% recovery) and the rinse-and-swab method recovered 0.28 ng (5.8% recovery). However, average recoveries were significantly different among three analysts and considerable variation in yields were observed, possibly due to storage time. Furthermore, consistent with prior reports, the DNA recovered from brass casings was only 16% of that recovered from nickel-plated casings and the average yield of DNA from fired casings was reduced to 67% of unfired casings. Moreover, DNA extracts from brass or nickel-plated casings did not appear to contain amplification inhibitors and only 30/596 appeared severely degraded. Finally, both the published rinse-and-swab and soaking methods yielded more DNA than all modifications of the two methods. Overall, both methods yielded equivalent DNA quantities. Additionally, recovery of DNA from any given cartridge casing may be dependent on storage time as well as the skill, proficiency, and experience of the analyst and may reflect stochastic effects, particularly for casings containing low copy and/or degraded DNA.
Machining performance of cutting tools and part quality are affected by the geometric condition of the cutting edge, which is influenced by thermomechanical loads experienced during the process. Tool condition monitoring (TCM) systems provide insight for timely replacement of cutting tools. However, existing TCM systems are expensive and require specialized equipment or sensors, hindering widespread adoption. A novel TCM system is developed herein using an elastomeric tactile sensor. Sensor images of the cutting edge are used to quantify wear using two distinct algorithms. In the first algorithm, the unworn and worn edges are identified based on Canny edge detect. In the second, the unworn edge is identified using edge detection while the region of wear is identified using a relative intensity method. In both cases, the maximum wear width is calculated based on an experimentally determined pixel to-physical distance scale. The TCM system is first used to estimate flank wear on a solid carbide helical end mill before evaluating its robustness by employing it to estimate insert wear of an indexable helical end mill. Measurements are also performed manually using an optical microscope and a high-resolution focus variation microscope for verification. The novel technique estimates flank wear in the solid carbide tool with a high accuracy of 98%. Larger discrepancies are observed for the inserts, however, with overlapping uncertainties. In conclusion, the technique shows promise in adaptability, automation, and closed loop control of machine tools.
Purpose: To study the effect of number of pinholes for a novel Single Photon Emission Computed Tomography (SPECT) system for onboard molecular and functional imaging. Methods: Comparison studies were performed using simulation for the 49-pinhole SPECT system and a series of reductions in number of pinholes. Trajectories about the breast of a supine patient were considered. Minimum distances, radii of rotation (RORs), were determined by requirements to fully view the region of interest (ROI) and to avoid collision between the detector and the patient. Reductions in RORs translate into improvements in sensitivity. Starting from the 49-pinhole system, pinholes were removed pod by pod. The furthest two end pods in the Sup-Inf direction were removed first for their higher likelihood of alleviating the collision avoidance criteria. After iterating through different combinations of pinhole pods, and selecting three combinations, the corresponding RORs were used to analytically calculate sensitivities. Results: Based on the Methods procedure, 3 combination of pods removal were identified: 1) Superior peripheral pod 2) Inferior peripheral pod 3) both pods. RORs were reduced at only one multi-pinhole stop. Analytic calculation showed that sensitivities were reduced from 0.032 for the 49-pinhole system to 0.028 for 42-pinhole and to 0.023 for 39-pinhole system respectively. The sensitivity per pinhole detector was approximately the same for all three cases. Conclusion: For the trajectories considered, only minimal improvements in RORs were identified by removing pinhole pods. Consequently, sensitivities decreased in proportion to the number of pinholes. Studies of other anatomical sites are needed to determine if in some cases sensitivity per pinhole can be improved by removing some pinholes. PHS/NIH/NCI grant R21-CA156390-01A1.
Purpose: To demonstrate an embedded tissue equivalent presage dosimeter for measuring 3D doses in moving tumors and to study the interplay effect between the tumor motion and intensity modulation in hypofractioned Volumetric Modulated Arc Therapy(VMAT) lung treatment. Methods: Motion experiments were performed using cylindrical Presage dosimeters (5cm diameter by 7cm length) mounted inside the lung insert of a CIRS thorax phantom. Two different VMAT treatment plans were created and delivered in three different scenarios with the same prescribed dose of 18 Gy. Plan1, containing a 2 centimeter spherical CTV with an additional 2mm setup margin, was delivered on a stationary phantom. Plan2 used the same CTV except expanded by 1 cm in the Sup-Inf direction to generate ITV and PTV respectively. The dosimeters were irradiated in static and variable motion scenarios on a Truebeam system. After irradiation, high resolution 3D dosimetry was performed using the Duke Large Field-of-view Optical-CT Scanner, and compared to the calculated dose from Eclipse. Results: In the control case (no motion), good agreement was observed between the planned and delivered dose distributions as indicated by 100% 3D Gamma (3% of maximum planned dose and 3mm DTA) passing rates in the CTV. In motion cases gamma passing rates was 99% in CTV. DVH comparisons also showed good agreement between the planned and delivered dose in CTV for both control and motion cases. However, differences of 15% and 5% in dose to PTV were observed in the motion and control cases respectively. Conclusion: With very high dose nature of a hypofraction treatment, significant effect was observed only motion is introduced to the target. This can be resulted from the motion of the moving target and the modulation of the MLC. 3D optical dosimetry can be of great advantage in hypofraction treatment dose validation studies.
Purpose: To construct a robotic SPECT system and demonstrate its capability to image a thorax phantom on a radiation therapy flat-top couch. The system has potential for on-board functional and molecular imaging in radiation therapy. Methods: A robotic SPECT imaging system was developed utilizing a Digirad 2020tc detector and a KUKA KR150-L110 robot. An imaging study was performed with the PET CT Phantom, which includes 5 spheres: 10, 13, 17, 22 and 28 mm in diameter. Sphere-tobackground concentration ratio was 6:1 of Tc99m. The phantom was placed on a flat-top couch. SPECT projections were acquired with a parallel-hole collimator and a single pinhole collimator. The robotic system navigated the detector tracing the flat-top table to maintain the closest possible proximity to the phantom. For image reconstruction, detector trajectories were described by six parameters: radius-of-rotation, x and z detector shifts, and detector rotation θ, tilt ϕ and twist γ. These six parameters were obtained from the robotic system by calibrating the robot base and tool coordinates. Results: The robotic SPECT system was able to maneuver parallel-hole and pinhole collimated SPECT detectors in close proximity to the phantom, minimizing impact of the flat-top couch on detector-to-COR (center-ofrotation) distance. In acquisitions with background at 1/6th sphere activity concentration, photopeak contamination was heavy, yet the 17, 22, and 28 mm diameter spheres were readily observed with the parallel hole imaging, and the single, targeted sphere (28 mm diameter) was readily observed in the pinhole region-of-interest (ROI) imaging. Conclusion: Onboard SPECT could be achieved by a robot maneuvering a SPECT detector about patients in position for radiation therapy on a flat-top couch. The robot inherent coordinate frame could be an effective means to estimate detector pose for use in SPECT image reconstruction. PHS/NIH/NCI grant R21-CA156390-01A1.
Insulated end caps installed on DC pins of Combined Charging System (CCS) inlets have been identified as potential debris sources within electric vehicle supply equipment (EVSE) connectors, increasing the risk of electric shock and fire hazards. Although standards such as IEC 62196-1:2022 specify mechanical pull-force requirements for these end caps, it remains unclear whether these requirements provide adequate robustness under real-world conditions. To address this concern, the National Charging Experience (ChargeX) Consortium's Hardware Task Force conducted evaluations of insulated end caps used in OEM CCS inlets. This study assesses the performance of insulated end caps used in OEM CCS inlets, specifically those installed on DC pins, using the procedures defined in IEC 62196-1:2022 (Section Sign) 26.7 and SAE J3400, supplemented by additional experimental conditioning. To ensure relevance to real-world conditions, NLR collaborated with charging network operators (CNOs) to guide the selection of charging inlet samples. Material analyses of the insulated end cap samples were conducted to confirm that the tested materials reflected the types and properties commonly observed in the field. The selected samples underwent temperature and humidity conditioning followed by pull-force testing to evaluate the end-cap integrity. Although SAE J3400 inlets were not directly tested due to limited diversity in available field data, the underlying end-cap principles between CCS and SAE J3400 are comparable, allowing the study's insights to be relevant to both technologies. Overall, this study provides a structured evaluation framework to inform potential refinements to mechanical pull-force requirements in charging standards.
It has been proposed that Tonle Sap, a lake in Cambodia, 100 km long and 30 km wide, marks the location of an elongate basin formed by the oblique impact of a comet or asteroid. The impact is considered to have produced melted ejecta found now as tektites over much of southeast Asia and Australia. The location of the lake, its approximate age, its size, and the orientation of its long axis (toward Australia) are consistent with this hypothesis. Our scientific objectives were to find impact or shock metamorphosed rocks unambiguously related to the Tonle Sap basin, to collect samples of rocks that may represent those melted to produce Australasian tektites, and to learn as much as possible about Cambodian geology. Using 1:200,000-scale geologic maps with fairly detailed descriptions of the rock units, we selected a number of acceptable 'phnoms' (hills that rise abruptly out of the surrounding plain) that may contain rocks affected by the postulated Tonle Sap impact. A map of central Cambodia is shown, and the locations of sites where samples were collected are indicated. A list of those sites, together with a description of the rocks reported to be present at each site, is given. No obviously shock-metamorphosed or suevite-like rocks were observed. Recent alluvium surrounding Tonle Sap is judged to be lake sediment deposited when the lake surface was at a higher elevation.
Future NASA earth science missions, including the Earth Observing System (EOS), will be generating vast amounts of data that must be processed and stored at various locations around the world. Here we present a stepwise-refinement of the intelligent database management (IDM) of the distributed active archive center (DAAC - one of seven regionally-located EOSDIS archive sites) architecture, to showcase the telecommunications issues involved. We develop this architecture into a general overall design. We show that the current evolution of protocols is sufficient to support IDM at Gbps rates over large distances. We also show that network design can accommodate a flexible data ingestion storage pipeline and a user extraction and visualization engine, without interference between the two.
Two experiments examined perceived spatial orientation in a small environment as a function of experiencing that environment under three conditions: real-world, desktop-display (DD), and head-mounted display (HMD). Across the three conditions, participants acquired two targets located on a perimeter surrounding them, and attempted to remember the relative locations of the targets. Subsequently, participants were tested on how accurately and consistently they could point in the remembered direction of a previously seen target. Results showed that participants were significantly more consistent in the real-world and HMD conditions than in the DD condition. Further, it is shown that the advantages observed in the HMD and real-world conditions were not simply due to nonspatial response strategies. These results suggest that the additional idiothetic information afforded in the real-world and HMD conditions is useful for orientation purposes in our presented task domain. Our results are relevant to interface design issues concerning tasks that require spatial search, navigation, and visualization.
Space sickness symptoms were observed by 4 specially trained observers on Spacelab-1. Three reported persistent symptoms, and vomited repeatedly during the first and/or second day of flight. Head movements on all axes were provocative, particularly in pitch and roll. Head acceleration data recorded from 2 symptomatic crewmen showed that after several hours of physical activity in orbit, symptoms appeared, and thereafter both crewmen were compelled to limit head movements. Firm body contact with motionless surfaces helped alleviate symptoms. When crewmembers floated into unfamiliar body orientations in the cabin, inherent ambiguities in static visual orientation cues sometimes produced spatial reorientation episodes which were also provocative. Symptoms largely resembled those of other forms of prolonged motion sickness, superimposed upon other symptoms attributable to fluid shift. All 4 eventually used anti-motion sickness drugs. When they did, vomiting frequency was reduced. By the 4th day, symptoms subsided, and head accelerations again increased in magnitude and variability. Sickness intensity in orbit was not predicted by statistically concordant results of 6 acute preflight susceptibility tests. However, results from a longer duration preflight prism goggles test showed an apparent correlation. All subjects were asymptomatic making head movements in parabolic flight 4 days after the mission, but not 1 year later. Overall, results support the view that space sickness is a motion sickness.
We present schemes for real-time generalized mesh cutting. Starting with the a basic example, we describe the details of implementing cutting on single and multiple surface objects as well as hybrid and volumetric meshes using virtual tools with single and multiple cutting surfaces. These methods have been implemented in a robust surgical simulation environment allowing us to model procedures ranging from animal dissection to cleft lip correction.
We present schemes for real-time generalized interactions such as probing, piercing, cauterizing and ablating virtual tissues. These methods have been implemented in a robust, real-time (haptic rate) surgical simulation environment allowing us to model procedures including animal dissection, microsurgery, hysteroscopy, and cleft lip repair.