Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thermal Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Impacts of an Ammonia Leak on the Cabin Atmosphere of the International Space Station

Toxic chemical release into the cabin atmosphere is one of the three major emergency scenarios identified on the International Space Station (ISS). The release of anhydrous ammonia, the coolant used in the U.S. On-orbit Segment (USOS) External Active Thermal Control Subsystem (EATCS), into the ISS cabin atmosphere is one of the most serious toxic chemical release cases identified on board ISS. The USOS Thermal Control System (TCS) includes an Internal Thermal Control Subsystem (ITCS) water loop and an EATCS ammonia loop that transfer heat at the interface heat exchanger (IFHX). Failure modes exist that could cause a breach within the IFHX. This breach would result in high pressure ammonia from the EATCS flowing into the lower pressure ITCS water loop. As the pressure builds in the ITCS loop, it is likely that the gas trap, which has the lowest maximum design pressure within the ITCS, would burst and cause ammonia to enter the ISS atmosphere. It is crucial to first characterize the release of ammonia into the ISS atmosphere in order to develop methods to properly mitigate the environmental risk. This paper will document the methods used to characterize an ammonia leak into the ISS cabin atmosphere. A mathematical model of the leak was first developed in order to define the flow of ammonia into the ISS cabin atmosphere based on a series of IFHX rupture cases. Computational Fluid Dynamics (CFD) methods were then used to model the dispersion of the ammonia throughout the ISS cabin and determine localized effects and ventilation effects on the dispersion of ammonia. Lastly, the capabilities of the current on-orbit systems to remove ammonia were reviewed and scrubbing rates of the ISS systems were defined based on the ammonia release models. With this full characterization of the release of ammonia from the USOS TCS, an appropriate mitigation strategy that includes crew and system emergency response procedures, personal protection equipment use, and atmosphere monitoring and scrubbing hardware can be established.

Duchesne, Stephanie M.↗

Integrated control of thermally distorted large space antennas

The objective is to develop a control system design method that (1) recognizes the time dependence of the thermal distortion due to orbital motion and (2) controls variables that are directly related to far field performance for earth pointing space antennas. The first objective is accomplished by expanding the distortion into principal components that are orthogonal in space and time. The approach for the second objective is to expand the far zone electric field in a Zernike-Bessel series. The method accommodates tapered feeds and arbitrary polarizations. Simulations are performed for a geosynchronous radiometer to determine the effectiveness of the control system under variations in solar geometry, structure materials and thermal properties.

Tolson, Robert H.↗

An experimental study on the performance of closed loop pulsating heat pipe (CLPHP) with methanol as a working fluid

Thermal control is an important topic for thermal management of small electrical and electronic devices. Closed loop pulsating heat pipe (CLPHP) arises as the best solution for thermal control. The aim of this experimental study is to search a CLPHP of better thermal performance for cooling different electrical and electronic devices. In this experiment, methanol is used as working fluid. The effect of using methanol as a working fluid is studied on thermal performance in different filling ratios and angles of inclination. A copper capillary tube is used where the inner diameter is 2 mm,outer diameter is 2.5 mm and 250 mm long. The CLPHP has 8 loops where the evaporation section is 50 mm, adiabatic section is 120 mm and condensation section is 80 mm. The experiment is done using FR of 40%-70% with 10% of interval and angles of inclination 0° (vertical), 30°, 45°, 60° varying heat input. The results are compared on the basis of evaporator temperature, condenser temperature and their differences, thermal resistance, heat transfer co-efficient, power input and pulsating time. The results demonstrate the effect of methanol in different filling ratios and angles of inclination. M ethanol shows better performance at 30° inclination with 40% FR.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Space environmental effects on LDEF composites: A leading edge coated graphite epoxy panel

The electronics module cover for the leading edge (Row D 9) experiment M0003-8 was fabricated from T300 graphite/934 epoxy unidirectional prepreg tape in a (O(sub 2), +/- 45, O(sub 2), +/- 45, 90, 0)(sub s) layup. This 11.75 in x 16.75 in panel was covered with thermal control coatings in three of the four quadrants with the fourth quadrant uncoated. The composite panel experienced different thermal cycling extremes in each quadrant due to the different optical properties of the coatings and bare composite. The panel also experienced ultraviolet (UV) and atomic oxygen (AO) attack as well as micrometeoroid and space debris impacts. An AO reactivity of 0.99 x 10(exp -24) cm(sup 3)/atom was calculated for the bare composite based on thickness loss. The white urethane thermal control coatings (A276 and BMS 1060) prevented AO attack of the composite substrate. However, the black urethane thermal control coating (Z306) was severely eroded by AO, allowing some AO attack of the composite substrate. An interesting banding pattern on the AO eroded bare composite surface was investigated and found to match the dimensions of the graphite fiber tow widths as prepregged. Also, erosion depths were greater in the darker bands. Five micrometeoroid/space debris impacts were cross sectioned to investigate possible structural damage as well as impact/AO interactions. Local crushing and delaminations were found to some extent in all of the impacts. No signs of coating undercutting were observed despite the extensive AO erosion patterns seen in the exposed composite material at the impact sites. An extensive microcrack study was performed on the panel along with modeling of the thermal environment to estimate temperature extremes and thermal shock. The white coated composite substrate displayed almost no microcracking while the black coated and bare composite showed extensive microcracking. Significant AO erosion was seen in many of the cracks in the bare composite.

George, Pete E.↗

Contamination control engineering design guidelines for the aerospace community

Thermal control surfaces, solar arrays, and optical devices may be adversely affected by a small quantity of molecular and/or particulate contamination. What is rarely discussed is how one: (1) quantifies the level of contamination that must be maintained in order for the system to function properly, and (2) enforces contamination control to ensure compliance with requirements. This document is designed to address these specific issues and is intended to serve as a handbook on contamination control for the reader, illustrating process and methodology while providing direction to more detailed references when needed. The effects of molecular contamination on reflecting and transmitting surfaces are examined and quantified in accordance with MIL STD 1246C. The generation, transportation, and deposition of molecular contamination is reviewed and specific examples are worked to illustrate the process a design engineer can use to estimate end of life cleanliness levels required by solar arrays, thermal control surfaces, and optical surfaces. A similar process is used to describe the effect of particulate contamination as related to percent area coverage (PAC) and bi-directional reflectance distribution function (BRDF). Relationships between PAC and surface cleanliness, which include the effects of submicron sized particles, are developed and BRDF is related to specific sensor design parameters such as Point Source Transmittance (PST). The pros and cons of various methods of preventing, monitoring, and cleaning surfaces are examined and discussed.

Tribble, A. C.↗

Control of thermal balance by a liquid circulating garment based on a mathematical representation of the human thermoregulatory system

Test data and a mathematical model of the human thermoregulatory system were used to investigate control of thermal balance by means of a liquid circulating garment (LCG). The test data were derived from five series of experiments in which environmental and metabolic conditions were varied parametrically as a function of several independent variables, including LCG flowrate, LCG inlet temperature, net environmental heat exchange, surrounding gas ventilation rate, ambient pressure, metabolic rate, and subjective/obligatory cooling control. The resultant data were used to relate skin temperature to LCG water temperature and flowrate, to assess a thermal comfort band, to demonstrate the relationship between metabolic rate and LCG heat dissipation, and so forth. The usefulness of the mathematical model as a tool for data interpretation and for generation of trends and relationships among the various physiological parameters was also investigated and verified.

Kuznetz, L. H.↗

Arbitrage and Capacity Firming in Coordination with Day-Ahead Bidding of a Hybrid PV Plant

A hybrid PV plant (HPP) combines a photovoltaic (PV) plant with a battery energy storage system (BESS), which is considered a promising step towards the future of renewable power plants by the U.S. Department of Energy. When the renewable penetration reaches a significant level, a hybrid PV plant can bid in as a controllable thermal plant in the future electricity market. In this study, a bidding and BESS scheduling model is proposed for the HPP. The robust optimization (RO) technique has been utilized to identify the worst-case scenario of uncertainties during the bidding process. To address the overly conservative issue of the single-stage RO, we have decoupled the BESS schedule for arbitrage and PV capacity firming by a two-stage RO formulation. By comparing the output of single-stage RO and two-stage RO, the two-stage RO bids and schedules in a more aggressive manner, which increases the income of HPP. Also, the penalty of under-generation is considered in our model so that the day-ahead bidding decision and arbitrage schedules can be adjusted based on the potential UNDER-GENERATION penalty. Because the proposed model is non-convex and contains multi-stages, the Column-and-Constraint Generation (C&CG) algorithm is applied to the model as the solution. The proposed model has shown better economic performance compared to a state-of-art single-stage bidding method in case studies.

BESS scheduling↗

Program to design, fabricate, test, and deliver a thermal control-mixing control device for the George C. Marshall Space Flight Center

The development and testing of a temperature sensor and pulse duration modulation (PDM) diverter valve for a thermal control-mixing control device are described. The temperature sensor selected for use uses a fluidic pin amplifier in conjunction with an expansion device. This device can sense changes of less than 0.25 F with greater than 15:1 signal to noise ratio when operating with a typical Freon pump supplied pressure. The pressure sensitivity of the sensor is approximately 0.0019 F/kPa. The valve which was selected was tested and performed with 100% flow diversion. In addition, the valve operates with a flow efficiency of at least 95%, with the possibility of attaining 100% if the vent flow of the PDM can be channeled through the last stage of the diverter valve. A temperature sensor which utilized an orifice bridge circuit and proportional-vortex combination mixing valve were also evaluated, but the concepts were rejected due to various problems.

Thurston, T. S.↗

An Active Broad Area Cooling Model of a Cryogenic Propellant Tank with a Single Stage Reverse Turbo-Brayton Cycle Cryocooler

As focus shifts towards long-duration space exploration missions, an increased interest in active thermal control of cryogenic propellants to achieve zero boil-off of cryogens has emerged. An active thermal control concept of considerable merit is the integration of a broad area cooling system for a cryogenic propellant tank with a combined cryocooler and circulator system that can be used to reduce or even eliminate liquid cryogen boil-off. One prospective cryocooler and circulator combination is the reverse turbo-Brayton cycle cryocooler. This system is unique in that it has the ability to both cool and circulate the coolant gas efficiently in the same loop as the broad area cooling lines, allowing for a single cooling gas loop, with the primary heat rejection occurring by way of a radiator and/or aftercooler. Currently few modeling tools exist that can size and characterize an integrated reverse turbo-Brayton cycle cryocooler in combination with a broad area cooling design. This paper addresses efforts to create such a tool to assist in gaining a broader understanding of these systems, and investigate their performance in potential space missions. The model uses conventional engineering and thermodynamic relationships to predict the preliminary design parameters, including input power requirements, pressure drops, flow rate, cycle performance, cooling lift, broad area cooler line sizing, and component operating temperatures and pressures given the cooling load operating temperature, heat rejection temperature, compressor inlet pressure, compressor rotational speed, and cryogenic tank geometry. In addition, the model allows for the preliminary design analysis of the broad area cooling tubing, to determine the effect of tube sizing on the reverse turbo-Brayton cycle system performance. At the time this paper was written, the model was verified to match existing theoretical documentation within a reasonable margin. While further experimental data is needed for full validation, this tool has already made significant steps towards giving a clearer understanding of the performance of a reverse turbo-Brayton cycle cryocooler integrated with broad area cooling technology for zero boil-off active thermal control.

Guzik, Monica C.↗

Thermal design and development of a planetary probe - Pioneer Venus large probe

The thermal control system developed for the Large Atmospheric Probe of the Pioneer Venus Multiprobe Mission is described. The scope of the thermal control task requires maintaining the probe internal equipment shelf temperatures within a nonoperating range of -40 to 122 F and an operating range of -4 to 122 F during three different mission phases: (1) preseparation, the transit phase of the mission when the probe is attached to the Multiprobe Spacecraft Bus, (2) postseparation, the free-flight cruise phase of the mission following release from the Bus, and (3) descent, the phase of the mission from preentry equipment turn-on to impact on the Venus surface. Thermal control for these phases is achieved by a combination of passive thermal finishes on the probe exterior surfaces and heaters mounted on the equipment shelves. Verification of the adequacy of the total thermal design to meet all mission requirements has been completed.

Hennis, L. A.↗

Passive Cooling for Mercury Surface Lander Electronics

A significant barrier to operation of a mission on the surface of Mercury is the temperature. At Mercury’s perihelion distance of 0.313 AU, the solar intensity is 10.6 times the solar flux at Earth orbit, and at the subsolar point, the maximum surface temperature reaches 427°C. For a mission landing on the surface of Mercury at latitude of 40°S, we analyzed using passive thermal control to reduce the temperature of the critical electronics to within the operation temperature limits of silicon devices. The thermal control requires reducing the thermal conductance and infrared flux from the high temperature surface and surrounding spacecraft, and moderating the solar heat input using a surface coating with high solar reflectivity, and maximizing thermal cooling with high infrared emissivity. Using this approach, we find that we can passively cool an electronics box to a temperature of 393K (120°C) using a radiator-white surface with solar absorptivity 0.11 and infrared emissivity 0.91. This temperature is well under 175C target we use for the limits of high-temperature silicon integrated circuits, including RAM and microcontrollers. We could further reduce this operating temperature to as low as 321K (48°C) with an advanced thermal coating, a temperature well within the operational limits of conventional electronics.

Mercury↗

Passive Cooling for Mercury Surface Lander Electronics

A significant barrier to operation of a mission on the surface of Mercury is the temperature. At Mercury’s perihelion distance of 0.313 AU, the solar intensity is 10.6 times the solar flux at Earth orbit, and at the subsolar point, the maximum surface temperature reaches 427°C. For a mission landing on the surface of Mercury at latitude of 40°S, we analyzed using passive thermal control to reduce the temperature of the critical electronics to within the operation temperature limits of silicon devices. The thermal control requires reducing the thermal conductance and infrared flux from the high temperature surface and surrounding spacecraft, and moderating the solar heat input using a surface coating with high solar reflectivity, and maximizing thermal cooling with high infrared emissivity. Using this approach, we find that we can passively cool an electronics box to a temperature of 393K (120°C) using a radiator-white surface with solar absorptivity 0.11 and infrared emissivity 0.91. This temperature is well under 175C target we use for the limits of high-temperature silicon integrated circuits, including RAM and microcontrollers. We could further reduce this operating temperature to as low as 321K (48°C) with an advanced thermal coating, a temperature well within the operational limits of conventional electronics

Mercury↗

James Webb Space Telescope Integrated Science Instrument Module Thermal Balance/Thermal Vacuum Test Configuration and Test Planning at NASA's Goddard Space Flight Center

The James Webb Space Telescope (JWST) is the next of the great observatories , scheduled to be launched in 2014. Three of the four science instruments are passively cooled to their operational temperature range of 36K to 40K, and the fourth instrument is actively cooled to its operational temperature of approximately 6K. Thermal-vacuum testing of the flight science instruments at the Integrated Science Instrument Module (ISIM) element level will take place within a newly constructed shroud cooled by gaseous helium inside Goddard Space Flight Center s (GSFC) Space Environment Simulator (SES). The test enclosure surrounding the instruments during the integrated ISIM-level thermal balance testing is complex, and is designed to simulate as closely as possible the in-flight conductive and radiative thermal environment around the ISIM. Thermal control and measurement of parasitic sources of heat leak into the test volume is critical, as the dissipation plus known parasitics in the flight ISIM is approximately 454 mW, and additional parasitics attributed to the flight enclosure itself are nearly equal to this, resulting in the energy balance of the inflight ISIM being less than 1.0 W. Sources of test-induced parasitics must be carefully controlled and measured, and the ability to thermally control the test environment is critical to enable accurate thermal balance testing and thermal model correlation. This paper describes the test configuration and plans for the ISIM-level thermal vacuum/thermal balance testing at GSFC.

Glazer, Stuart↗

Numerical Study of Ammonia Leak and Dispersion in the International Space Station

Management of off-nominal situations on-board the International Space Station (ISS) is important to its continuous operation. One situation of concern is an accidental release of a chemical into the ISS atmosphere. In particular, introduction of ammonia into the cabin atmosphere can occur via the interface heat exchangers (IFHX) between the external thermal control system containing ammonia and internal thermal control system that uses water as a coolant to remove heat from ISS subsystems. Breach of the water/ammonia barrier of the IFHX can lead to a catastrophic rupture. Once the liquid water/ammonia mixture exits the ITCS, it instantly vaporizes and mixes with the U.S. Laboratory cabin atmosphere that results in rapid contamination of the cabin. The goal of the study is to assess the amount of ammonia in the Russian Segment by the time the crew is able to isolate the U.S. Segment. A Computational Fluid Dynamics (CFD) model for an accurate prediction of airflow and ammonia transport in the frozen flow field within the assembly complete ISS cabin was developed. The localized effects of ammonia dispersion are examined and discussed.

Son, Chang H.↗

Precision control of thermal transport in cryogenic single-crystal silicon devices

We report on the diffusive-ballistic thermal conductance of multi-moded single-crystal silicon beams measured below 1 K. It is shown that the phonon mean-free-path ℓ is a strong function of the surface roughness characteristics of the beams. This effect is enhanced in diffuse beams with lengths much larger than ℓ, even when the surface is fairly smooth, 5–10 nm rms, and the peak thermal wavelength is 0.6 μm. Resonant phonon scattering has been observed in beams with a pitted surface morphology and characteristic pit depth of 30 nm. Hence, if the surface roughness is not adequately controlled, the thermal conductance can vary significantly for diffuse beams fabricated across a wafer. In contrast, when the beam length is of order ℓ, the conductance is dominated by ballistic transport and is effectively set by the beam cross-sectional area. We have demonstrated a uniformity of ±8% in fractional deviation for ballistic beams, and this deviation is largely set by the thermal conductance of diffuse beams that support the micro-electro-mechanical device and electrical leads. In addition, we have found no evidence for excess specific heat in single-crystal silicon membranes. This allows for the precise control of the device heat capacity with normal metal films. We discuss the results in the context of the design and fabrication of large-format arrays of far-infrared and millimeter wavelength cryogenic detectors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

ITCS Test Strip Development and Certification

Internal coolant loops used for International Space Station thermal control must be periodically monitored for system health, including pH, biocide levels and any indication of ammonia. The presence of ammonia, possible via a microleak in the interface between the internal and external thermal control systems, could be a danger to the crew. The Internal Thermal Control System (ITCS) Sampling Kit uses test strips as a colorimetric indicator of pH and concentrations of biocide and free ammonia. This paper describes the challenges in designing an ammonia colorimetric indicator in a variable pH environment, as well as lessons learned, ultimately resulting in a robust test strip to indicate a hazardous ammonia leak.

Carrigan, Caitlin↗

Potential for improved silicon ribbon growth through thermal environment control

The Ribbon-to-Ribbon (RTR) process for growth of silicon ribbon is described. This process involves the fabrication of a microcrystalline ribbon of silicon and subsequent grain size enhancement through a laser recrystallization process. The microribbon is obtained from a Thermal Expansion Shear Separation (TESS) process which allows a CVD layer of silicon to be separated from a temporary molybdenum substrate. Efforts to achieve increased solar cell efficiencies and higher area production rates have been problematical. Furnaces, which are necessary for thermal stress control, have been shown to contribute contamination to substrates resulting in degraded efficiencies. Recent results with a new furnace design indicate efficiencies in excess of 9% will be routine. Limitations to area throughput arise due to fundamental linear velocity limitations and width limitations necessary to prevent the occurrence of thermal buckling. Calculations are reported which show the influence of thermal profile on buckling tendencies, and a proposed electron beam technique is considered which promises high throughput with minimal buckling.

Gurtler, R. W.↗