Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Test methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

A Model-Reference Adaptive Direct-Power Control Scheme for Grid-Interactive Inverters

This paper develops an adaptive direct power control scheme for grid-interactive inverters while the control parameters are adaptively adjusted as the grid and filter parameters vary under different conditions. To demonstrate the efficacy and robustness of the adaptive operation, the performance of the adaptive controller is compared with a typical direct power controller by estimating the filter and grid impedances using a model reference parameter estimation technique with small signal injection. The simulation results verify that the developed methodology can track the reference power setpoints under output circuit parameter uncertainties while the typical design leads to instability. To improve the performance of the adaptive technique and eliminate the need for filter parameter estimation, a Lyapunov stability criterion-based model-reference adaptive direct power controller is designed to track the filter impedance. The developed method was tested using MATLAB/Simulink software to demonstrate the effectiveness of the proposed method. The results verify that adaptively tuning the control parameter can still maintain stable operation if the control gains are poorly selected while applying the classical method leads to abnormal operation or instability.

Gursoy, Mehmetcan↗

Detection of Local/Regional Events in Kuwait Using Next-Generation Detection Algorithms

Seismic networks around the world use conventional triggering algorithms to detect seismic signals in order to locate local/regional seismic events. Kuwait National Seismological Network (KNSN) of Kuwait Institute of Scientific Research (KISR) is operating seven broad-band and short-period three-component stations in Kuwait. The network is equipped with Nanometrics digitizers and uses Antelope and Guralp acquisition software for processing and archiving the data. In this study, we selected 10 days of archived hourly-segmented continuous data of five stations (Figure 1) and 250 days of continuous recording at MIB. For the temporary deployment our selection criteria was based on KNSN catalog intensity for the period of time we test the method. An autonomous event detection and clustering framework is employed to test a more complete catalog of this short period of time. The goal is to illustrate the effectiveness of the technique and pursue the framework for longer period of time.

58 GEOSCIENCES↗

A Pattern-Recognition-Based Ensemble Data Imputation Framework for Sensors from Building Energy Systems

Building operation data are important for monitoring, analysis, modeling, and control of building energy systems. However, missing data is one of the major data quality issues, making data imputation techniques become increasingly important. There are two key research gaps for missing sensor data imputation in buildings: the lack of customized and automated imputation methodology, and the difficulty of the validation of data imputation methods. In this paper, a framework is developed to address these two gaps. First, a validation data generation module is developed based on pattern recognition to create a validation dataset to quantify the performance of data imputation methods. Second, a pool of data imputation methods is tested under the validation dataset to find an optimal single imputation method for each sensor, which is termed as an ensemble method. The method can reflect the specific mechanism and randomness of missing data from each sensor. The effectiveness of the framework is demonstrated by 18 sensors from a real campus building. The overall accuracy of data imputation for those sensors improves by 18.2% on average compared with the best single data imputation method.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NDMAS

Overview of Current ART-GCR Data: Fuel Fabrication, Irradiation Monitoring (Fuel & Graphite – near real-time for HDG-1), Post-Irradiation Examination (Fuel & Graphite), Graphite Characterization (Baseline and Irradiated), High Temperature Metals Mechanical Tests, Design, Methods, and Validation Data, Japan Atomic Energy Agency’s High Temperature Test Reactor (HTTR), Argonne National Laboratory’s Natural convection Shutdown heat removal Test Facility (NSTF), Oregon State University’s High Temperature Test Facility (HTTF), Generation IV International VHTR Materials Handbook, Additional related data, and Advanced Test Reactor operations (near real-time).

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Laser notching ceramics for reliable fracture toughness testing

A new method for notching ceramics was developed using a picosecond laser for fracture toughness testing of alumina samples. The test geometry incorporated a single-edge-V-notch that was notched using picosecond laser micromachining. This method has been used in the past for cutting ceramics, and is known to remove material with little to no thermal effect on the surrounding material matrix. This study showed that laser-assisted-machining for fracture toughness testing of ceramics was reliable, quick, and cost effective. In order to assess the laser notched single-edge-V-notch beam method, fracture toughness results were compared to results from other more traditional methods, specifically surface-crack in flexure and the chevron notch bend tests. Lastly, the results showed that picosecond laser notching produced precise notches in post-failure measurements, and that the measured fracture toughness results showed improved consistency compared to traditional fracture toughness methods.

36 MATERIALS SCIENCE↗

Hypothesis tests for the detection of constant speed radiation moving sources

Radiation Portal Monitors are deployed in linear network to detect radiological material in motion. As a complement to single and multichannel detection algorithms, inefficient under too low signal to noise ratios, temporal correlation algorithms have been introduced. Test hypothesis methods based on empirically estimated mean and variance of the signals delivered by the different channels have shown significant gain in terms of a tradeoff between detection sensitivity and false alarm probability. This paper discloses the concept of a new hypothesis test for temporal correlation detection methods, taking advantage of the Poisson nature of the registered counting signals, and establishes a benchmark between this test and its empirical counterpart. The simulation study validates that in the four relevant configurations of a pedestrian source carrier under respectively high and low count rate radioactive background, and a vehicle source carrier under the same respectively high and low count rate radioactive background, the newly introduced hypothesis test ensures a significantly improved compromise between sensitivity and false alarm, while guaranteeing the stability of its optimization parameter regardless of signal to noise ratio variations between 2 to 0.8. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental determination of radiated internal wave power without pressure field data

We present a method to determine, using only velocity field data, the time-averaged energy flux (J) and total radiated power P for two-dimensional internal gravity waves. Both (J) and P are determined from expressions involving only a scalar function, the stream function ψ. We test the method using data from a direct numerical simulation for tidal flow of a stratified fluid past a knife edge. The results for the radiated internal wave power given by the stream function method agree to within 0.5% with results obtained using pressure and velocity data from the numerical simulation. The results for the radiated power computed from the stream function agree well with power computed from the velocity and pressure if the starting point for the stream function computation is on a solid boundary, but if a boundary point is not available, care must be taken to choose an appropriate starting point. We also test the stream function method by applying it to laboratory data for tidal flow past a knife edge, and the results are found to agree with the direct numerical simulation. The supplementary material includes a Matlab code with a graphical user interface that can be used to compute the energy flux and power from two-dimensional velocity field data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Ground Truth Program: Simulations as Test Beds for Social Science Research Methods.

Social systems are uniquely complex and difficult to study, but understanding them is vital to solving the world’s problems. The Ground Truth program developed a new way of testing the research methods that attempt to understand and leverage the Human Domain and its associated complexities. The program developed simulations of social systems as virtual world test beds. Not only were these simulations able to produce data on future states of the system under various circumstances and scenarios, but their causal ground truth was also explicitly known. Research teams studied these virtual worlds, facilitating deep validation of causal inference, prediction, and prescription methods. The Ground Truth program model provides a way to test and validate research methods to an extent previously impossible, and to study the intricacies and interactions of different components of research.

97 MATHEMATICS AND COMPUTING↗

Method for Calculating Delayed Gamma-Ray Response in the ACRR Central Cavity and FREC-II Cavity Using MCNP

This document presents the process for a new method developed for the characterization of the delayed gamma-ray radiation fields in pulse reactors like the Annular Core Research Reactor (ACRR) and the Fueled Ring External Cavity (FREC-II). The environments used to test this method in the ACRR were FF, LB44, PLG and CdPoly, and the environments used in the FREC-II were FF with rods-down, FF with rods-up, CdPoly with rods-down and CdPoly with rods-up. All environment configurations used the same fission product gamma-ray source energy spectrum. This method required the fission sites located in the MCNP KCODE source tapes. A FORTRAN script was written to translate and extract the coordinates for the fission sites. The 10K fission sites were then input it into an MCNP SOURCE mode script. Using a MATLAB script, a parametric analysis was done, and it helped determine that 10K fission sites are an appropriate number of coordinates to converge to the correct answer. The method gave excellent results and was tested in the ACRR, FREC-II and White Sands Missile Range (WSMR). This method can be applied to other pulse research reactors as well.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Method to determine the electron–ion temperature relaxation rate from test particle distributions

Here a method to calculate the electron–ion energy exchange rate from the forces on and velocities of an ensemble of test particles is described. The essence of the method is that the energy exchange rate is related to the covariance between the distribution of velocities of test particles and the forces acting on them. The energy exchange rate is related to the electron–ion temperature relaxation rate in the limit of a low test particle speed. A proof of concept is conducted with first-principles molecular dynamics simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Detection of nuclear testing from surface concentration measurements: Analysis of radioxenon from the February 2013 underground test in North Korea

A method is outlined and tested to detect low level nuclear or chemical sources from time series of concentration measurements. The method uses a mesoscale atmospheric model to simulate the concentration signature from a known or suspected source at a receptor which is then regressed successively against segments of the measurement series to create time series of metrics that measure the goodness of fit between the signatures and the measurement segments. The method was applied to radioxenon data from the Comprehensive Test Ban Treaty (CTBT) collection site in Ussuriysk, Russia (RN58) after the Democratic People's Republic of Korea (North Korea) underground nuclear test on February 12, 2013 near Punggye. The metrics were found to be a good screening tool to locate data segments with a strong likelihood of origin from Punggye, especially when multiplied together to a determine the joint probability. Metrics from RN58 were also used to find the probability that activity measured in February and April of 2013 originated from the Feb 12 test. A detailed analysis of an RN58 data segment from April 3/4, 2013 was also carried out for a grid of source locations around Punggye and identified Punggye as the most likely point of origin. Thus, the results support the strong possibility that radioxenon was emitted from the test site at various times in April and was detected intermittently at RN58, depending on the wind direction. The method does not locate unsuspected sources, but instead, evaluates the probability of a source at a specified location. However, it can be extended to include a set of suspected sources. Extension of the method to higher resolution data sets, arbitrary sampling, and time-varying sources is discussed along with a path to evaluate uncertainty in the calculated probabilities.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Advanced Zonal Infiltration Measurement Method for Multifamily Buildings: A Novel Test Procedure to Determine Air Leakage Through External and Internal Surfaces

Measuring air infiltration through the external building envelope as well as between adjacent zones within a building is important since air leakage is related to increased energy use and poor indoor air quality (IAQ). State of the art methods can determine both leakages, however it can be both time consuming and labor intensive as it requires running both guarded and compartmentalization tests. This paper presents our work on developing a simplified testing procedure to determine power law flow equation leakage parameters of both external and internal boundaries of tested zones. The proposed Zonal Multipoint Pressure Test (ZMPT) method modulates airflow in the zone using a variable airflow measurement panel (mounted in either a window or the door), and solving the mass balance equations for the leakage parameters. ZMPT results were compared to conventional test results and found to correlate to within +/-7%.

Jayarathne, Tharanga↗

Characterization and integration of the singular test integrals in the method-of-moments implementation of the electric-field integral equation

In this paper, we characterize the logarithmic singularities arising in the method of moments from the Green’s function in integrals over the test domain, and we use two approaches for designing geometrically symmetric quadrature rules to integrate these singular integrands. These rules exhibit better convergence properties than quadrature rules for polynomials and, in general, lead to better accuracy with a lower number of quadrature points. In this work, we demonstrate their effectiveness for several examples encountered in both the scalar and vector potentials of the electric-field integral equation (singular, near-singular, and far interactions) as compared to the commonly employed polynomial scheme and the double Ma–Rokhlin–Wandzura (DMRW) rules, whose sample points are located asymmetrically within triangles.

42 ENGINEERING↗

Accuracy of HVAC Load Predictions: Validation of EnergyPlus and DOE-2 using FLEXLAB Measurements

The aim of the project reported here was to better understand the level of accuracy of three building energy simulation (BES) engines (‘engines’) — EnergyPlus™, DOE-2.1e, and DOE-2.2 — by identifying and investigating significant deviations between the performance predicted by these engines and actual performance as measured in the FLEXLAB® test facility at Lawrence Berkeley National Laboratory (LBNL). The specific test conditions included some of those prescribed in ANSI/ASHRAE Standard 140 - Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs. Detailed measurements of FLEXLAB performance, including indoor temperatures and heat fluxes and air-flow and water flow rates and temperatures in the Heating, Ventilating and Air Conditioning (HVAC) system, together with hourly weather data, were recorded and used in analyzing the simulation results from EnergyPlus v8.8, DOE-2.2 v3.65 and DOE-2.1e v127. These engines are commonly used in the United States for building energy code compliance, federal, state, and utility incentives programs, as well as energy efficient design of new buildings and energy retrofit of existing buildings. Seven conventional overhead mixing ventilation scenarios were tested and each engine was found to have a similar level of agreement with the measurements of space-level heating and sensible cooling loads. These results provide useful information regarding the accuracy of these engines in predicting the cooling and heating load elements of whole building energy performance. This information is intended for practitioners who are concerned about transitioning between simulation tools with different engines and for managers of utility programs leveraging these tools for evaluating and/or projecting measure savings to be incentivized under their programs. The results of the comparisons of simulated and measured performance indicate that the predictions from all three engines are not significantly different. The 24-hour average value of the absolute mean bias indicates the likely magnitude of the error in any particular case. The average mean bias is reduced by cancelation of overprediction in one case by underprediction in another. The daytime absolute mean biases, which may be more important for both energy performance and occupant comfort, are ~6%, presumably because of the greater complexity involved in simulating in the presence of solar radiation. EnergyPlus typically overpredicts the cooling load and/or underpredicts the heating load by ~1.5% and the DOE-2 engines typically underpredict the cooling load by approximately the same amount. The Root Mean Square Error is relatively more sensitive to shorter term variations in the difference between predicted and measured loads; the three engines have similar values, ~10%, suggesting that the uncertainties in their predictions of peak loads may also be similar in magnitude. The implication of these results is that users, both designers and program analysts, can use EnergyPlus, DOE-2.1e, or DOE-2.2 to model conventional commercial buildings equipped with overhead mixing ventilation with a similar level of confidence. Further work is required to better understand the variability in the level of agreement between the engine predictions and FLEXLAB measurements, where a particular engine will agree well with FLEXLAB in some cases and not so well in others and another engine will agree or disagree in different cases. As the sources of this variability are identified and eliminated or reduced significantly, it is recommended that the experimental capabilities and methods developed in the study reported here should be applied to validating heating and cooling load calculations for spaces with different types of furniture and miscellaneous loads. These methods should then be applied to low energy space conditioning systems in EnergyPlus including, in particular, radiant slab and radiant ceiling panel cooling and heating systems and ‘mixed mode’ systems that combine mechanical cooling and natural ventilation systems, focusing on controls, including control of thermal mass. The work reported here addresses the conventional method of heating and cooling occupied spaces; other methods, such as the use of radiant heating and cooling systems have the potential to provide equivalent occupant comfort, or better, with lower energy consumption. These systems are addressed more explicitly in EnergyPlus but there is a need for empirical validation to give users the same level of confidence in modeling these systems that they have, or should have, in modeling conventional systems, based on the results presented here.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Strong Stability Preserving Analysis for Explicit Multistage Two-Derivative Time-Stepping Schemes Based on Taylor Series Conditions

High-order strong stability preserving (SSP) time discretizations are usually needed to ensure the nonlinear (and sometimes non-inner-product) strong stability properties of spatial discretizations specially designed for the solution of hyperbolic PDEs. Multi-derivative time-stepping methods have recently been increasingly used for evolving hyperbolic PDEs, and the strong stability properties of these methods are of interest. In our prior work we explored time discretizations that preserve the strong stability properties of spatial discretizations coupled with forward Euler and a second-derivative formulation. Yet, many spatial discretizations do not satisfy strong stability properties when coupled with this second-derivative formulation, but rather with a more natural Taylor series formulation. Here, we demonstrate sufficient conditions for an explicit two-derivative multistage method to preserve the strong stability properties of spatial discretizations in a forward Euler and Taylor series formulation. We call these strong stability preserving Taylor series (SSP-TS) methods. We also prove that the maximal order of SSP-TS methods is p=6, and define an optimization procedure that allows us to find such SSP methods. Several types of these methods are presented and their efficiency compared. Finally, these methods are tested on several PDEs to demonstrate the benefit of SSP-TS methods, the need for the SSP property, and the sharpness of the SSP time-step in many cases.

97 MATHEMATICS AND COMPUTING↗

R-matrix approach with proper boundary conditions for dissipative and nondissipative collision processes

We develop an R-matrix approach to treating collision processes which explicitly takes into account, by means of a simple energy-dependent analytic function, the out-of-phase oscillations of the incident and scattered standing waves in the interior region. Thereby we avoid the use of the Bloch operator. In place of the Bloch operator the incident wave provides the source term in an inhomogeneous equation for the scattered wave. We take those subchannels not treated exactly into account via the optical potential, which is generally non-Hermitian due to dissipation at the boundary. The optical potential is constructed on a real analytic basis using a resolvent that satisfies outgoing-wave boundary conditions. The use of an analytic basis together with the direct determination of the K matrix, rather than the R matrix, at the boundary (this is done by matching the interior wave function to the nearly exact analytic solution beyond the boundary) makes the method particularly well suited to the treatment of ultracold collisions. We have tested our method by applying it to one-photon single-ionization of (He1s{sup 2}) accompanied by excitation to He{sup +}(2s) or He{sup +}(2p) for photon energies above the complete breakup threshold, where the optical potential is non-Hermitian. Excellent agreement with experiment is obtained for the cross sections for photoionization to both He{sup +} (n=1) and to He{sup +} (n=2). The 2s-to-2p branching ratio is strongly influenced by both the optical potential and, at photon energies less than a few tens of eV above the breakup threshold, the nonadiabatic dipole mixing of the 2s and 2p states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Material Analysis for a Fire Assessment.

This report consolidates technical information on several materials and material classes for a fire assessment. The materials include three polymeric materials, wood, and hydraulic oil. The polymers are polystyrene, polyurethane, and melamine- formaldehyde foams. Samples of two of the specific materials were tested for their behavior in a fire - like environment. Test data and the methods used to test the materials are presented. Much of the remaining data are taken from a literature survey. This report serves as a reference source of properties necessary to predict the behavior of these materials in a fire.

Brown, Alexander↗

Applied Controls for sCO 2 Brayton Cycles

Sandia has a history of testing supercritical CO 2 Brayton Cycles to explore operation fundamentals and provide validation data for computer models. These systems have always had data acquisition and controls features. The Development Platform (DP) has been a flagship system for loop testing and operation but has been limited to manual control of many systems. Manual operation has increased operating complexity and reduced stability and repeatability. This work documents automated control development by linearizing otherwise non-linear valves, addition of closed-loop proportional-integral control software that has been tuned to the Sandia DP. It also describes testing of control methods that have improved test quality and reliability as shown in actual test data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗