Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Target tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Small Orbital Stereo Tracking Camera Technology Development

On-Orbit Small Debris Tracking and Characterization is a technical gap in the current National Space Situational Awareness necessary to safeguard orbital assets and crew. This poses a major risk of MOD damage to ISS and Exploration vehicles. In 2015 this technology was added to NASA's Office of Chief Technologist roadmap. For missions flying in or assembled in or staging from LEO, the physical threat to vehicle and crew is needed in order to properly design the proper level of MOD impact shielding and proper mission design restrictions. Need to verify debris flux and size population versus ground RADAR tracking. Use of ISS for In-Situ Orbital Debris Tracking development provides attitude, power, data and orbital access without a dedicated spacecraft or restricted operations on-board a host vehicle as a secondary payload. Sensor Applicable to in-situ measuring orbital debris in flux and population in other orbits or on other vehicles. Could enhance safety on and around ISS. Some technologies extensible to monitoring of extraterrestrial debris as well To help accomplish this, new technologies must be developed quickly. The Small Orbital Stereo Tracking Camera is one such up and coming technology. It consists of flying a pair of intensified megapixel telephoto cameras to evaluate Orbital Debris (OD) monitoring in proximity of International Space Station. It will demonstrate on-orbit optical tracking (in situ) of various sized objects versus ground RADAR tracking and small OD models. The cameras are based on Flight Proven Advanced Video Guidance Sensor pixel to spot algorithms (Orbital Express) and military targeting cameras. And by using twin cameras we can provide Stereo images for ranging & mission redundancy. When pointed into the orbital velocity vector (RAM), objects approaching or near the stereo camera set can be differentiated from the stars moving upward in background.

Bryan, Tom↗

Processing Near-Infrared Imagery of the Orion Heatshield During EFT-1 Hypersonic Reentry

The Scientifically Calibrated In-Flight Imagery (SCIFLI) team captured high-resolution, calibrated, near-infrared imagery of the Orion capsule during atmospheric reentry of the EFT-1 mission. A US Navy NP-3D aircraft equipped with a multi-band optical sensor package, referred to as Cast Glance, acquired imagery of the Orion capsule's heatshield during a period when Orion was slowing from approximately Mach 10 to Mach 7. The line-of-sight distance ranged from approximately 65 to 40 nmi. Global surface temperatures of the capsule's thermal heatshield derived from the near-infrared intensity measurements complemented the in-depth (embedded) thermocouple measurements. Moreover, these derived surface temperatures are essential to the assessment of the thermocouples' reliance on inverse heat transfer methods and material response codes to infer the surface temperature from the in-depth measurements. The paper describes the image processing challenges associated with a manually-tracked, high-angular rate air-to-air observation. Issues included management of significant frame-to-frame motions due to both tracking jerk and jitter as well as distortions due to atmospheric effects. Corrections for changing sky backgrounds (including some cirrus clouds), atmospheric attenuation, and target orientations and ranges also had to be made. The image processing goal is to reduce the detrimental effects due to motion (both sensor and capsule), vibration (jitter), and atmospherics for image quality improvement, without compromising the quantitative integrity of the data, especially local intensity (temperature) variations. The paper will detail the approach of selecting and utilizing only the highest quality images, registering several co-temporal image frames to a single image frame to the extent frame-to-frame distortions would allow, and then co-adding the registered frames to improve image quality and reduce noise. Using preflight calibration data, the registered and averaged infrared intensity images were converted to surface temperatures on the Orion capsule's heatshield. Temperature uncertainties will be discussed relative to uncertainties of surface emissivity and atmospheric transmission loss. Comparison of limited onboard surface thermocouple data to the image derived surface temperature will be presented.

Spisz, Thomas S.↗

Mitigation of Angle Tracking Errors Due to Color Dependent Centroid Shifts in SIM-Lite

The SIM-Lite astrometric interferometer will search for Earth-size planets in the habitable zones of nearby stars. In this search the interferometer will monitor the astrometric position of candidate stars relative to nearby reference stars over the course of a 5 year mission. The elemental measurement is the angle between a target star and a reference star. This is a two-step process, in which the interferometer will each time need to use its controllable optics to align the starlight in the two arms with each other and with the metrology beams. The sensor for this alignment is an angle tracking CCD camera. Various constraints in the design of the camera subject it to systematic alignment errors when observing a star of one spectrum compared with a start of a different spectrum. This effect is called a Color Dependent Centroid Shift (CDCS) and has been studied extensively with SIM-Lite's SCDU testbed. Here we describe results from the simulation and testing of this error in the SCDU testbed, as well as effective ways that it can be reduced to acceptable levels.

Spectral↗

Evaluation of the beam-induced depolarization of the HJET target at the EIC

The Polarized Atomic Hydrogen Gas Jet Target (HJET) has played a central role in the absolute calibration of proton beam polarization at RHIC and is foreseen as a key component of the hadron polarimetry program at the future Electron–Ion Collider (EIC). The substantially higher beam current, reduced bunch spacing, and shorter bunch length planned for EIC operation motivate a careful reassessment of possible beam-induced depolarization of the jet target. In this paper, the depolarization of ground-state hydrogen atoms caused by the time-dependent magnetic field of the circulating polarized proton beam is quantitatively evaluated. The hydrogen atom is treated as a four-level hyperfine system in a holding magnetic field, and transitions driven by harmonic components of the bunch-induced magnetic field are analyzed using time-dependent quantum-mechanical evolution along atomic trajectories. Numerical tracking of hydrogen atoms through the beam region is performed using nominal EIC beam parameters. It is shown that, for a holding field of 120 mT (as used at RHIC), the resulting depolarization of the jet target at the EIC is negligibly small, ≲ 0.01 %, and well below the level relevant for EIC polarization accuracy requirements. The stability of this result with respect to plausible variations of the EIC proton beam parameters is also evaluated. In addition, possible effects under alternative experimental conditions are also examined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MO-FG-BRA-07: Intrafractional Motion Effect Can Be Minimized in Tomotherapy Stereotactic Body Radiotherapy (SBRT)

Purpose: Tomotherapy has unique challenges in handling intrafractional motion compared to conventional LINAC. In this study, we analyzed the impact of intrafractional motion on cumulative dosimetry using actual patient motion data and investigated real time jaw/MLC compensation approaches to minimize the motion-induced dose discrepancy in Tomotherapy SBRT treatment. Methods: Intrafractional motion data recorded in two CyberKnife lung treatment cases through fiducial tracking and two LINAC prostate cases through Calypso tracking were used in this study. For each treatment site, one representative case has an average motion (6mm) and one has a large motion (10mm for lung and 15mm for prostate). The cases were re-planned on Tomotherapy for SBRT. Each case was planned with 3 different jaw settings: 1cm static, 2.5cm dynamic, and 5cm dynamic. 4D dose accumulation software was developed to compute dose with the recorded motions and theoretically compensate motions by modifying original jaw and MLC to track the trajectory of the tumor. Results: PTV coverage in Tomotherapy SBRT for patients with intrafractional motion depends on motion type, amplitude and plan settings. For the prostate patient with large motion, PTV coverage changed from 97.2% (motion-free) to 47.1% (target motion-included), 96.6% to 58.5% and 96.3% to 97.8% for the 1cm static jaw, 2.5cm dynamic jaw and 5cm dynamic jaw setting, respectively. For the lung patient with large motion, PTV coverage discrepancies showed a similar trend of change. When the jaw and MLC compensation program was engaged, the motion compromised PTV coverage was recovered back to >95% for all cases and plans. All organs at risk (OAR) were spared with < 5% increase from original motion-free plans. Conclusion: Tomotherapy SBRT is less motion-impacted when 5cm dynamic jaw is used. Once the motion pattern is known, the jaw and MLC compensation program can largely minimize the compromised target coverage and OAR sparing.

60 APPLIED LIFE SCIENCES↗

Tracking 3-D body motion for docking and robot control

An advanced method of tracking three-dimensional motion of bodies has been developed. This system has the potential to dynamically characterize machine and other structural motion, even in the presence of structural flexibility, thus facilitating closed loop structural motion control. The system's operation is based on the concept that the intersection of three planes defines a point. Three rotating planes of laser light, fixed and moving photovoltaic diode targets, and a pipe-lined architecture of analog and digital electronics are used to locate multiple targets whose number is only limited by available computer memory. Data collection rates are a function of the laser scan rotation speed and are currently selectable up to 480 Hz. The tested performance on a preliminary prototype designed for 0.1 in accuracy (for tracking human motion) at a 480 Hz data rate includes a worst case resolution of 0.8 mm (0.03 inches), a repeatability of plus or minus 0.635 mm (plus or minus 0.025 inches), and an absolute accuracy of plus or minus 2.0 mm (plus or minus 0.08 inches) within an eight cubic meter volume with all results applicable at the 95 percent level of confidence along each coordinate region. The full six degrees of freedom of a body can be computed by attaching three or more target detectors to the body of interest.

Donath, M.↗

Quantitative modeling of the accuracy in registering preoperative patient-specific anatomic models into left atrial cardiac ablation procedures

Purpose: In cardiac ablation therapy, accurate anatomic guidance is necessary to create effective tissue lesions for elimination of left atrial fibrillation. While fluoroscopy, ultrasound, and electroanatomic maps are important guidance tools, they lack information regarding detailed patient anatomy which can be obtained from high resolution imaging techniques. For this reason, there has been significant effort in incorporating detailed, patient-specific models generated from preoperative imaging datasets into the procedure. Both clinical and animal studies have investigated registration and targeting accuracy when using preoperative models; however, the effect of various error sources on registration accuracy has not been quantitatively evaluated. Methods: Data from phantom, canine, and patient studies are used to model and evaluate registration accuracy. In the phantom studies, data are collected using a magnetically tracked catheter on a static phantom model. Monte Carlo simulation studies were run to evaluate both baseline errors as well as the effect of different sources of error that would be present in a dynamicin vivo setting. Error is simulated by varying the variance parameters on the landmark fiducial, physical target, and surface point locations in the phantom simulation studies. In vivo validation studies were undertaken in six canines in which metal clips were placed in the left atrium to serve as ground truth points. A small clinical evaluation was completed in three patients. Landmark-based and combined landmark and surface-based registration algorithms were evaluated in all studies. In the phantom and canine studies, both target registration error and point-to-surface error are used to assess accuracy. In the patient studies, no ground truth is available and registration accuracy is quantified using point-to-surface error only. Results: The phantom simulation studies demonstrated that combined landmark and surface-based registration improved landmark-only registration provided the noise in the surface points is not excessively high. Increased variability on the landmark fiducials resulted in increased registration errors; however, refinement of the initial landmark registration by the surface-based algorithm can compensate for small initial misalignments. The surface-based registration algorithm is quite robust to noise on the surface points and continues to improve landmark registration even at high levels of noise on the surface points. Both the canine and patient studies also demonstrate that combined landmark and surface registration has lower errors than landmark registration alone. Conclusions: In this work, we describe a model for evaluating the impact of noise variability on the input parameters of a registration algorithm in the context of cardiac ablation therapy. The model can be used to predict both registration error as well as assess which inputs have the largest effect on registration accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An in-vacuo optical levitation trap for high-intensity laser interaction experiments with isolated microtargets

We report on the design, construction, and characterisation of a new class of in-vacuo optical levitation trap optimised for use in high-intensity, high-energy laser interaction experiments. The system uses a focused, vertically propagating continuous wave laser beam to capture and manipulate micro-targets by photon momentum transfer at much longer working distances than commonly used by optical tweezer systems. A high speed (10 kHz) optical imaging and signal acquisition system was implemented for tracking the levitated droplets position and dynamic behaviour under atmospheric and vacuum conditions, with ±5 μm spatial resolution. Optical trapping of 10 ± 4 μm oil droplets in vacuum was demonstrated, over timescales of >1 h at extended distances of ∼40 mm from the final focusing optic. The stability of the levitated droplet was such that it would stay in alignment with a ∼7 μm irradiating beam focal spot for up to 5 min without the need for re-adjustment. The performance of the trap was assessed in a series of high-intensity (10{sup 17} W cm{sup −2}) laser experiments that measured the X-ray source size and inferred free-electron temperature of a single isolated droplet target, along with a measurement of the emitted radio-frequency pulse. These initial tests demonstrated the use of optically levitated microdroplets as a robust target platform for further high-intensity laser interaction and point source studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dosimetric Implications of Residual Tracking Errors During Robotic SBRT of Liver Metastases

Purpose: Although the metric precision of robotic stereotactic body radiation therapy in the presence of breathing motion is widely known, we investigated the dosimetric implications of breathing phase–related residual tracking errors. Methods and Materials: In 24 patients (28 liver metastases) treated with the CyberKnife, we recorded the residual correlation, prediction, and rotational tracking errors from 90 fractions and binned them into 10 breathing phases. The average breathing phase errors were used to shift and rotate the clinical tumor volume (CTV) and planning target volume (PTV) for each phase to calculate a pseudo 4-dimensional error dose distribution for comparison with the original planned dose distribution. Results: The median systematic directional correlation, prediction, and absolute aggregate rotation errors were 0.3 mm (range, 0.1-1.3 mm), 0.01 mm (range, 0.00-0.05 mm), and 1.5° (range, 0.4°-2.7°), respectively. Dosimetrically, 44%, 81%, and 92% of all voxels differed by less than 1%, 3%, and 5% of the planned local dose, respectively. The median coverage reduction for the PTV was 1.1% (range in coverage difference, −7.8% to +0.8%), significantly depending on correlation (P=.026) and rotational (P=.005) error. With a 3-mm PTV margin, the median coverage change for the CTV was 0.0% (range, −1.0% to +5.4%), not significantly depending on any investigated parameter. In 42% of patients, the 3-mm margin did not fully compensate for the residual tracking errors, resulting in a CTV coverage reduction of 0.1% to 1.0%. Conclusions: For liver tumors treated with robotic stereotactic body radiation therapy, a safety margin of 3 mm is not always sufficient to cover all residual tracking errors. Dosimetrically, this translates into only small CTV coverage reductions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of the Feasibility of UAS-Based EMI Sensing for Underground Utilities Detection and Mapping

This paper investigates the feasibility of using a linear current sensing (LCS) technique integrated on an unmanned aerial system (UAS) for detecting and mapping underground infrastructure rapidly and cost-effectively. The LCS technique is based on data from a wide band of electromagnetic induction frequencies (50 kHz to 2 MHz) using a vector magnetic field gradiometer. This technique takes advantage of a slowly decaying secondary magnetic field in order to achieve greater standoff detection distance ($\frac{1}{R^2}$ vs. $\frac{1}{R^6}$ for compact metallic targets during EMI sensing, where R is the distance from a target to the sensor). These secondary magnetic fields are produced by the excite current on long conductors, allowing detection at a distance of 10 meters or more. The system operates between tens of kHz to a few MHz and uses either an active EMI source or existing EM fields to excite this linear current on a long metallic subsurface target. Once excited, these linear currents produce a secondary magnetic field that is detected with an above ground triaxial magnetic field gradiometer. By moving and tracking its geolocation, the system outputs rich datasets sufficient to support high-fidelity forward and inverse EMI models for estimating the depth and orientation of deep underground long linear metallic infrastructure. The system’s hardware and its integration to a UAS system are outlined, along with the formulation of LCS theory, and numerical and experimental data are presented. The results illustrate that the LCS technique offers large standoff detection, is adaptable to UAS, and could be used effectively for detecting deep underground infrastructure such as wires and pipes.

54 ENVIRONMENTAL SCIENCES↗

Signal Processor Development by Personnel of the JSC Signal Processing Section

The purpose of this paper is to describe systems and components of systems developed by personnel in the Signal Processing Section of the Tracking and Communications Division. The scope of this includes past developments which are in current use in NASA flight operations and future developments which are targeted for upcoming NASA applications. These projects specifically are: (1) NASA High Definition Television (HDTV) Project, (2) Video Codecs, (3) NASA Electronic Still Camera (ESC) Project, (4) Hercules Payload, (5) Ku-band Communications Adapter (KCA), (6) Windows Drivers for Satellite Interfacing to Commercial Equipment, and (7) Advanced Statistical Multiplexers. The methods used to determine what projects should be done in-house as opposed to which should not is based in NASA applications versus commercially available systems to meet those applications. If a commercial-off-the-shelf (COTS) component or system is available which meets the need, the first choice is to use COTS equipment. If it is not, and there is a NASA requirement, it is developed in-house. This results in technology which is being developed which otherwise was not available. Personnel involved in these projects have been contacted by many commercial companies interested in licensing or obtaining the NASA design.

Holland, S. Douglas↗

Gas Sensor Evaluations in Polymer Combustion Product Atmospheres

Toxic gases produced by the combustion or thermo-oxidative degradation of materials such as wire insulation, foam, plastics, or electronic circuit boards in space shuttle or space station crew cabins may pose a significant hazard to the flight crew. Toxic gas sensors are routinely evaluated in pure gas standard mixtures, but the possible interferences from polymer combustion products are not routinely evaluated. The NASA White Sands Test Facility (WSTF) has developed a test system that provides atmospheres containing predetermined quantities of target gases combined with the coincidental combustion products of common spacecraft materials. The target gases are quantitated in real time by infrared (IR) spectroscopy and verified by grab samples. The sensor responses are recorded in real time and are compared to the IR and validation analyses. Target gases such as carbon monoxide, hydrogen cyanide, hydrogen chloride, and hydrogen fluoride can be generated by the combustion of poly(vinyl chloride), polyimide-fluoropolymer wire insulation, polyurethane foam, or electronic circuit board materials. The kinetics and product identifications for the combustion of the various materials were determined by thermogravimetric-IR spectroscopic studies. These data were then scaled to provide the required levels of target gases in the sensor evaluation system. Multisensor toxic gas monitors from two manufacturers were evaluated using this system. In general, the sensor responses satisfactorily tracked the real-time concentrations of toxic gases in a dynamic mixture. Interferences from a number of organic combustion products including acetaldehyde and bisphenol-A were minimal. Hydrogen bromide in the products of circuit board combustion registered as hydrogen chloride. The use of actual polymer combustion atmospheres for the evaluation of sensors can provide additional confidence in the reliability of the sensor response.

Delgado, Rafael H.↗

Relative Abundances and Energy Spectra of C, N, and 0 as Measured by the Advanced Thin Ionization Calorimeter Balloon Experiment

We present results on the spectra and the relative abundances of C, N, and 0 nuclei in the cosmic radiation as measured from the Advanced Thin Ionization Calorimeter Balloon Experiment (ATIC) . The ATIC detector has completed two successful balloon flights from McMurdo, Antarctica lasting a total of more than 35 days. ATIC is designed as a multiple, long duration balloon flight, investigation of the cosmic ray spectra from below 50 GeV to near 100 TeV total energy, using a fully active Bismuth Germanate calorimeter. It is equipped with a large area mosaic of silicon detector pixels capable of charge identification from H to Fe. As a redundancy check for the charge identification and a particle tracking system, three projective layers of x-y scintillator hodoscopes were employed, above, in the middle and below a 0.75 nuclear interaction length graphite target.

Fazely, A. R.↗

A Detailed FLUKA-2005 Monte Carlo Simulation for the ATIC Detector

We have performed a detailed Monte Carlo (MC) calculation for the Advanced thin Ionization Calorimeter (ATIC) detector using the MC code FLUKA-2005 which is capable of simulating particles up to 10 PeV. The ATIC detector has completed two successful balloon flights from McMurdo, Antarctica lasting a total of more than 35 days. ATIC is designed as a multiple, long duration balloon Bight, investigation of the cosmic ray spectra from below 50 GeV to near 100 TeV total energy; using a fully active Bismuth Germanate @GO) calorimeter. It is equipped with a large mosaic of silicon detector pixels capable of charge identification and as a particle tracking system, three projective layers of x-y scintillator hodoscopes were employed, above, in the middle and below a 0.75 nuclear interaction length graphite target. Our calculations are part of an analysis package of both A- and energy-dependences of different nuclei interacting with the ATIC detector. The MC simulates the responses of different components of the detector such as the Simatrix, the scintillator hodoscopes and the BGO calorimeter to various nuclei. We also show comparisons of the FLUKA-2005 MC calculations with a GEANT calculation and data for protons, He and CNO.

Gunasingha, R. M.↗

Image-Driven Hybrid Structural Analysis Based on Continuum Point Cloud Method with Boundary Capturing Technique

Conventional approaches for the structural health monitoring of infrastructures often rely on physical sensors or targets attached to structural members, which require considerable preparation, maintenance, and operational effort, including continuous on-site adjustments. This paper presents an image-driven hybrid structural analysis technique that combines digital image processing (DIP) and regression analysis with a continuum point cloud method (CPCM) built on a particle-based strong formulation. Polynomial regressions capture the boundary shape change due to the structural loading and precisely identify the edge and corner coordinates of the deformed structure. The captured edge profiles are transformed into essential boundary conditions. This allows the construction of a strongly formulated boundary value problem (BVP), classified as the Dirichlet problem. Capturing boundary conditions from the digital image is novel, although a similar approach was applied to the point cloud data. It was shown that the CPCM is more efficient in this hybrid simulation framework than the weak-form-based numerical schemes. Unlike the finite element method (FEM), it can avoid aligning boundary nodes with regression points. A three-point bending test of a rubber beam was simulated to validate the developed technique. The simulation results were benchmarked against numerical results by ANSYS and various relevant numerical schemes. The technique can effectively solve the Dirichlet-type BVP, yielding accurate deformation, stress, and strain values across the entire problem domain when employing a linear strain model and increasing the number of CPCM nodes. In addition, comparative analysis with conventional displacement tracking techniques verifies the developed technique’s robustness. The proposed technique effectively circumvents the inherent limitations of traditional monitoring methods resulting from the reliance on physical gauges or target markers so that a robust and non-contact solution for remote structural health monitoring in real-scale infrastructures can be provided, even in unfavorable experimental environments.

Chemistry↗

Search for higgsinos in compressed mass spectra using low-momentum tracks in pp collisions at s=13 TeV with the ATLAS detector

This paper presents two searches for the electroweak production of higgsinos with compressed mass spectra using 140 fb−1 of s=13$$ \sqrt{s}=13 $$ TeV proton-proton collision data collected by the ATLAS experiment at the Large Hadron Collider. Events are required to feature an energetic jet, large missing transverse momentum, and at least one low-momentum charged particle that serves as a candidate higgsino decay product. In the first search, targeting higgsino mass splittings in the range of 0.3–1 GeV, the higgsinos are expected to predominantly decay into pions that are identified as low-momentum charged particles with large transverse impact parameters due to the long higgsino lifetime (cτ ≈ ?(0.1–10 mm)), and neural networks are used to discriminate between signal and background processes. The second search targets larger mass splittings in the range of 1–3 GeV, where the higgsinos are expected to decay promptly into low-momentum leptons, one of which is identified by dedicated low-momentum electron or muon taggers based on neural networks utilising tracking and calorimeter information. No significant excess above the Standard Model prediction is observed in either search and the results are interpreted within simplified models, to set lower limits on the masses of the higgsino-like charginos and neutralinos. Together, these searches exclude chargino masses below 126 GeV at 95% confidence level for mass splittings between the chargino and lightest neutralino in the range of 0.3–2 GeV. This represents the first ATLAS constraints in a portion of this parameter space and surpasses the limits previously set by other experiments.

Aad, G↗

Stereo-vision thermal imaging system for tracking flying animals in wind farm areas (CRADA #763) Abstract

CRADA 763: abstract ThermalTracker-3D (TT3D) is a stereo vision thermal imaging system that provides 3D flight information on detected birds, bats, and other flying targets. The system was initially developed for use in the siting and monitoring of offshore wind projects to establish pre-construction and operation collision risk data but can be applied to terrestrial wind energy projects as well as national security monitoring. This technology will reduce monitoring cost, decrease processing time, and provide more accurate data for wind energy developers/operators and regulatory agencies. While the current technology is at a high level of readiness, Technology Readiness Level (TRL) 7, there remain several barriers to commercialization, particularly around ease-of-use, that result in a low Adoption Readiness Level (ARL). The proposed work will advance commercialization readiness by streamlining calibration methods for built systems. This work will:1. 1. develop a software package for factory and dynamic calibration processes 2. test that package with existing prototype TT3D systems, and 3. conduct outreach with industry end-users.

ThermalTracker↗

A Simulated Fire Edge Vis-IR Detection and Tracking Approach for Autonomous sUAS in STEReO

This study presents a fire edge detection and tracking methodology for an autonomous small UAS (sUAS). The sUAS, onboard sensors, and wildfire are simulated to evaluate the methodology. A visible light (Vis) camera and an infrared (IR) camera are simulated onboard the sUAS to identify burnt, burning, and unburnt areas on a static wildfire bitmap. After differentiating between these areas, a form of nonlinear guidance law (NLGL) is used to generate virtual target points (VTP) that guide the sUAS so that the fire edge is kept within the camera FOV. The VTP are passed to the sUAS flight management system (FMS) in the form of waypoints. The approach was tested in simulation and demonstrated tracking curved, sharp, and linear fire edge shapes at different altitudes. Higher altitude tracking proved to demand the least control effort without sacrificing continuous tracking.

Autonomous UAV↗