Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Small systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Strategies for converting to a DBMS environment

The conversion to data base management systems processing techniques consists of three different strategies - one for each of the major stages in the development process. Each strategy was chosen for its approach in bringing about a smooth evolutionary type transition from one mode of operation to the next. The initial strategy of the indoctrination stage consisted of: (1) providing maximum access to current administrative data as soon as possible; (2) select and developing small prototype systems; (3) establishing a user information center as a central focal point for user training and assistance; and (4) developing a training program for programmers, management and ad hoc users in DBMS application and utilization. Security, the rate of the data dictionary, and data base tuning and capacity planning, and the development of a change of attitude in an automated office are issues meriting consideration.

Durban, D. M.↗

Simulating Large PEPs Tensor Networks on Small Quantum Devices

We systematically map low bond dimension PEPs tensor networks to quantum circuits. By measuring and reusing qubits, we are in principle able to simulate an N×M square lattice PEPs network (for arbitrary M) of bond dimension 2 using N+ 2 qubits. We then seek to determine if this mapping can yield useful values for long-range loop observables in the presence of quantum device noise in the topological Wen plaquette model by mapping a 3×3 PEPs tensor network to a 5-qubit quantum circuit and executing it on the Honeywell System Model H1-1 trapped-ion device. We find that, for this system size, the noisy observable values are indeed sufficient for diagnosing topological vs. trivial order as the Wen model is perturbed by a magnetic field term in the Hamiltonian. We provide an overview of the experimental procedure and its results. We then explain in greater detail our method for mapping 2D tensor networks to quantum circuits and its scaling properties. This serves as a proof-of-concept of the utilty of the measure-and-reuse approach for simulating large 2D quantum systems on small quantum devices.

MacCormack, Ian↗

UAS Service Supplier Network Performance

This report summarizes the performance of Unmanned Aircraft System (UAS) Service Suppliers (USS) in the Technical Capability Level 4 (TCL4) flight test performed by NASA and its partners in support of the UAS Traffic Management (UTM) concept. TCL4 is the final in a series of TCL demonstrations of a traffic management system for small UAS (sUAS). All demonstrations have been executed in collaboration with industry partners. The [FAA 2018] UTM Concept of Operations document describes UTM as:...the manner in which the FAA will support operations for predominantly sUAS operating in low altitude airspace. UTM utilizes industry’s ability to supply services under FAA’s regulatory authority where these services do not currently exist. It is a community-based traffic management system, where the Operators are responsible for the coordination, execution, and management of operations, with rules of the road established by FAA. UTM is designed to support the demand and expectations for a broad spectrum of operations with ever-increasing complexity and risk. UTM should be considered a collection of services rather than a monolithic application. The following section describes the architecture at a high level. For further insight, the FAA’s concept document [FAA 2018] or NASA’s earlier concept publication [NASA 2016] should be consulted.

Rios, Joseph L.↗

Observations on variational and projector Monte Carlo methods

Variational Monte Carlo and various projector Monte Carlo (PMC) methods are presented in a unified manner. Similarities and differences between the methods and choices made in designing the methods are discussed. Both methods where the Monte Carlo walk is performed in a discrete space and methods where it is performed in a continuous space are considered. It is pointed out that the usual prescription for importance sampling may not be advantageous depending on the particular quantum Monte Carlo method used and the observables of interest, so alternate prescriptions are presented. The nature of the sign problem is discussed for various versions of PMC methods. A prescription for an exact PMC method in real space, i.e., a method that does not make a fixed-node or similar approximation and does not have a finite basis error, is presented. This method is likely to be practical for systems with a small number of electrons. Approximate PMC methods that are applicable to larger systems and go beyond the fixed-node approximation are also discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On diamond, graphitic and amorphous carbons in primitive extraterrestrial solar system materials

Carbon is among the most abundant elements in the universe and carbon chemistry in meteorites and comets is an important key to understanding many Solar System and interstellar processes. Yet, the mineralogical properties and interrelations between various structural forms of elemental carbon remain ambiguous. Crystalline elemental carbons include rhombohedral graphite, hexagonal graphite, cubic diamond, hexagonal diamond (i.e., lonsdaleite or carbon-2H) and chaoite. Elemental carbon also occurs as amorphous carbon and poorly graphitized (or turbostratic) carbon but of all the forms of elemental carbon only graphite is stable under physical conditions that prevail in small Solar System bodies and in the interstellar medium. The recent discovery of cubic diamond in carbonaceous chondrites and hexagonal diamond in chondritic interplanetary dust particles (IDPs) have created a renewed interest in the crystalline elemental carbons that were not formed by shock processes on a parent body. Another technique, Raman spectroscopy, confirms a widespread occurrence of disordered graphite in the Allende carbonaceous chondrite and in chondritic IDPs. Elemental carbons have also been identified by their characteristic K-edge features in electron energy loss spectra (EELS). However, the spectroscopic data do not necessarily coincide with those obtained by selected area electron diffraction (SAED). In order to interpret these data in terms of rational crystalline structures, it may be useful to consider the principles underlying electron diffraction and spectroscopic analyses. Electron diffraction depends on electron scattering, on the type of atom and the distance between atoms in a crystal lattice. Spectroscopic data are a function of the type of atom and the energy of bonds between atoms. Also, SAED is a bulk sampling technique when compared to techniques such as Raman spectroscopy or EELS. Thus, it appears that combined analyses provide contradictory results and that amorphous, or short-range ordered, carbon identified by conventional TEM imaging and SAED may show evidence for sp(3) bonds in EELS spectra. It is suggested that complex, nanometer-scale, mineralogical interrelations are common to all elemental carbons irrespective of their origin. The subsequent thermal history, or energy balance, will determine the ultimate microstructure.

Rietmeijer, Frans J. M.↗

Tool Support for Parametric Analysis of Large Software Simulation Systems

The analysis of large and complex parameterized software systems, e.g., systems simulation in aerospace, is very complicated and time-consuming due to the large parameter space, and the complex, highly coupled nonlinear nature of the different system components. Thus, such systems are generally validated only in regions local to anticipated operating points rather than through characterization of the entire feasible operational envelope of the system. We have addressed the factors deterring such an analysis with a tool to support envelope assessment: we utilize a combination of advanced Monte Carlo generation with n-factor combinatorial parameter variations to limit the number of cases, but still explore important interactions in the parameter space in a systematic fashion. Additional test-cases, automatically generated from models (e.g., UML, Simulink, Stateflow) improve the coverage. The distributed test runs of the software system produce vast amounts of data, making manual analysis impossible. Our tool automatically analyzes the generated data through a combination of unsupervised Bayesian clustering techniques (AutoBayes) and supervised learning of critical parameter ranges using the treatment learner TAR3. The tool has been developed around the Trick simulation environment, which is widely used within NASA. We will present this tool with a GN&C (Guidance, Navigation and Control) simulation of a small satellite system.

Schumann, Johann↗

Accuracy considerations for Chebyshev rational approximation method (CRAM) in Burnup calculations

The burnup equations can in principle be solved by computing the exponential of the burnup matrix. However, due to the difficult numerical characteristics of burnup matrices, the problem is extremely stiff and the matrix exponential solution has previously been considered infeasible for an entire burnup system containing over a thousand nuclides. It was recently discovered by the author that the eigenvalues of burnup matrices are generally located near the negative real axis, which prompted introducing the Chebyshev rational approximation method (CRAM) for solving the burnup equations. CRAM can be characterized as the best rational approximation on the negative real axis and it has been shown to be capable of simultaneously solving an entire burnup system both accurately and efficiently. In this paper, the accuracy of CRAM is further studied in the context of burnup equations. The approximation error is analyzed based on the eigenvalue decomposition of the burnup matrix. It is deduced that the relative accuracy of CRAM may be compromised if a nuclide concentration diminishes significantly during the considered time step. Numerical results are presented for two test cases, the first one representing a small burnup system with 36 nuclides and the second one a full a decay system with 1531 nuclides. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Environmental and economic optima of solar home systems design: A combined LCA and LCC approach

Here, we compare the economic and environmental optimal design of Solar Home Systems (SHSs) and explore the role of economic incentives (such as tariffs and technology costs) in approximating the two optima. To achieve that, we present a methodology for the environmental and economic evaluation of grid-connected SHSs: user-scale electric systems involving a photovoltaic (PV) power system and a battery energy storage system. The proposed methodology is based on a mixed integer linear programming (MILP) optimization, life cycle assessment and life cycle costing. This methodological framework is applied to a case study involving a typical SHS installation in Italy. The results of the environmental optimal design brought to the evaluation of a 3.25 kW PV assisted by 8.66 kWh of nickel cobalt manganese batteries, whereas the costs of the SHS are minimized by a small PV system (less than 1 kW). Results underline that the environmental optimal configurations rely on battery technologies, which entails a significant cost compared to the grid connection. In contrast, the economic optimal design solutions is less impactful than the grid mix both from an environmental and economic points of view. Thanks to a reduction of batteries and PV costs, the environmental impact of the economic optimal design is expected to decrease in the future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SchrödingerNet: A Universal Neural Network Solver for the Schrödinger Equation

Recent advances in machine learning have facilitated numerically accurate solution of the electronic Schrödinger equation (SE) by integrating various neural network (NN)-based wave function ansatzes with variational Monte Carlo methods. Nevertheless, such NN-based methods are all based on the Born–Oppenheimer approximation (BOA) and require computationally expensive training for each nuclear configuration. In this work, we propose a novel NN architecture, SchrödingerNet, to solve the full electronic-nuclear SE by defining a loss function designed to equalize local energies across the system. This approach is based on a translationally, rotationally and permutationally symmetry-adapted total wave function ansatz that includes both nuclear and electronic coordinates. Furthermore, this strategy not only allows for an efficient and accurate generation of a continuous potential energy surface at any geometry within the well-sampled nuclear configuration space, but also incorporates non-BOA corrections, through a single training process. Comparison with benchmarks of atomic and small molecular systems demonstrates its accuracy and efficiency.

Chemical calculations↗

Shuttle compatible cryogenic liquid storage and supply systems

A detailed introduction is given to a wide variety of orbital cryogenic liquid storage and supply systems required for future vehicles by NASA and DOD. The systems include small cooling applications, large chemical and electrical orbit transfer vehicles and resupply tankers, and all have the common requirements of low-g fluid management for the accomplishment of gas-free liquid expulsion, and efficient thermal control in order to manage heat leak and tank pressure. The present study considers hydrogen, oxygen, methane, argon and helium tanks ranging from 0.6 to 37.4 cu m. Conceptual designs were generated for each tank system, and fluid dynamic, structural and thermal analyses were performed in view of Shuttle requirements.

Eberhardt, R. N.↗

Development of a Point of Care Technology for Military Medical Applications in Austere Environments

NASA, Lawrence Livermore National Laboratory (LLNL) and the Department of Defense (DoD) share a common interest in compact medical diagnostic technologies—also known as “point of care testing” (POCT) technologies. For NASA, the need is to take care of astronauts on deep space missions. For LLNL, the focus is on technologies needed to support homeland security applications. For DoD, the need is to support warfighters in military theaters of operation, especially for prolonged field care and en route care. A recently patented technology, “Portable Medical Diagnosis Instrument” (U.S. Patent 9824870), co-invented by NASA and LLNL, is being developed further in a partnership between NASA, LLNL and Travis Air Force Base, with a focus on military applications. This instrument, the NASA-LLNL Medical Tricorder, can be used for a wide range of clinical samples including breath, saliva and blood. One component of the Tricorder is the NASA E-Nose, a carbon nanotube-based chemical sensor, integrated into a hand-held smart phone, that can detect and measure “breath biomarkers” in the gas phase of exhaled breath. The response of the NASA E-Nose is rapid, which makes it possible to detect various gas-phase substances in real time. The NASA E-Nose, with modification, can also be used for breath condensate analysis. Another component of the Tricorder is a miniaturized microfluidic analyzer, under development by LLNL, that does not require any pumps. The microfluidic analyzer can detect and measure biomarkers in liquid samples, such as blood, saliva and breath condensate. This microfluidic system requires small quantities of liquid sample and can perform analysis very rapidly (seconds to minutes), which makes it possible to detect relevant biomarkers in near real time in the field. The Clinical Investigation Facility (CIF) at Travis Air Force Base is currently conducting research with the goal to develop improved field-able technologies and procedures for the emergency response to life threatening injuries soldiers may receive in theater. This work includes experimental large animal systems and comprehensive collection of clinical specimens and physiological data. NASA and LLNL are partnering with Travis to test and further develop the Tricorder technology for high priority military applications, initially focused on lung injury models and traumatic brain injury.

Loftus, David J.↗

Characterization of different forms of Zr-2.5Nb samples before and after neutron irradiation

Deleterious effects of hydride precipitation on the mechanical properties of Zr-based alloy systems have been studied for many years. Most of these studies have been conducted at high-temperature irradiation conditions that are compatible with those in commercial reactor systems, such as light water and pressurized water reactors. Evaluations of hydride effects on the mechanical properties of welded Zr-2.5Nb are sparse among these reported studies. Research on the mechanical properties of Zr-based alloys neutron irradiated at low temperatures (<100 °C) is also very rare in the literature. Since some companies are interested in using Zr-based alloys as structural materials and in other parts such as pressure tubes in small reactor systems, low-temperature irradiation studies of these materials are important. The current work presents an evaluation of the tensile properties of Zr-2.5Nb welded using tungsten inert gas and electron beam welding as a function of hydrogen charging and neutron irradiation at low temperatures (60–100 °C).

36 MATERIALS SCIENCE↗

Bayesian calibration of a hybrid nuclear collision model using $\textit{p}$₋Pb and Pb-Pb data at energies available at the CERN Large Hadron Collider

Here, we posit a unified hydrodynamic and microscopic description of the quark-gluon plasma (QGP) produced in ultrarelativistic p₋Pb and Pb-Pb collisions at $\sqrt{s}_\text{NN}$ = 5.02 TeV and evaluate our assertion using Bayesian inference. Specifically, we model the dynamics of both collision systems using initial conditions with parametric nucleon substructure, a preequilibrium free streaming stage, event-by-event viscous hydrodynamics, and a microscopic hadronic afterburner. Free parameters of the model, which describe the initial state and QGP medium are then simultaneously calibrated to fit charged-particle yields, mean $p_T$, and flow cumulants. We argue that the global agreement of the calibrated model with the experimental data strongly supports the existence of hydrodynamic flow in small collision systems at ultrarelativistic energies, and that the flow produced develops at length scales smaller than a single proton. Posterior estimates for the model's input parameters are obtained, and new insights into the temperature dependence of the QGP transport coefficients and event-by-event structure of the proton are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

WE-G-BRE-01: A High Power Nanotube X-Ray Microbeam Irradiator for Preclinical Brain Tumor Treatment

Purpose: Microbeam radiation therapy (MRT) is a new type of cancer treatment undergoing studies at various synchrotron facilities. The principle of MRT is using arrays of microscopically small, low-energy X-radiation for the treatment of various radio-resistant, deep-seated tumors. Our motivation is to develop a compact and inexpensive image guided MRT irradiator to use in the research lab setting. After a successful initial demonstration, here we report a second generation carbon nanotube (CNT) cathode based MRT tube, capable of producing multiple microbeam lines with an anticipated dose rate of 11 Gy/min per line. Methods: The system uses multiple line CNT source arrays to generate multiple focal lines on the anode. The increase in dose-rate, compared to our first generation system, is achieved by increasing the operating voltage from 160 kVp to 225kVp, adding multiple simultaneous focal lines on the anode, and a more efficient cooling mechanism using a 6kW oil-cooled anode. Results: This work will present the design and development process, challenges and solutions to meeting operating specifications, and the final design of the tube and collimator, along with optimization and stabilization of its use. A detailed characterization of its capabilities will be included with a comprehensive measurement of its X-ray focal line dimensions, an evaluation of its collimator alignment and microbeam dimensions, and phantom-based quantification of its dosimetric output. Conclusion: The development of a second generation, compact, multiple line MRT device using carbon nanotube (CNT) cathode based X-ray technology and a novel oil cooled anode design is presented here. With this new source, we are capable of delivering a total microbeam radiation dose comparable to the low end of the synchrotron based MRT systems for small animal brain tumor models.

60 APPLIED LIFE SCIENCES↗

Columbia County Habitat for Humanity Passive Townhomes

Columbia County (New York) Habitat for Humanity built a pair of townhomes to Passive House criteria with the purpose of exploring approaches for achieving Passive House performance and to eventually develop a prototype design for future projects. The project utilized a 2x6 frame wall with a structural insulated panel curtain wall and a ventilated attic over a sealed OSB ceiling air barrier. Mechanical systems include a single head, wall mounted ductless mini-split heat pump in each unit and a heat recovery ventilator. Costs were $26,000 per unit higher for Passive House construction compared with the same home built to ENERGY STAR version 3 specifications, representing about 18% of total construction cost. This report discusses the cost components, energy modeling results and lessons from construction. Two alternative ventilation systems are analyzed: a central system; and, a point-source system with small through-wall units distributed throughout the house. The report includes a design and cost analysis of these two approaches.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) for In-Situ Mars Surface Sample Analysis

The Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) project, funded by the NASA Planetary Instrument Concepts for the Advancement of Solar System Observations (PICASSO) Research Opportunities in Space and Earth Sciences (ROSES), will build upon previous miniaturized SEM designs and recent advancements in variable pressure SEM's to design and build a SEM to complete analyses of samples on the surface of Mars using the atmosphere as an imaging medium. This project is a collaboration between NASA Marshall Space Flight Center (MSFC), the Jet Propulsion Laboratory (JPL), electron gun and optics manufacturer Applied Physics Technologies, and small vacuum system manufacturer Creare. Dr. Ralph Harvery and environmental SEM (ESEM) inventor Dr. Gerry Danilatos serve as advisors to the team. Variable pressure SEMs allow for fine (nm-scale) resolution imaging and micron-scale chemical study of materials without sample preparation (e.g., carbon or gold coating). Charging of a sample is reduced or eliminated by the gas surrounding the sample. It is this property of ESEMs that make them ideal for locations where sample preparation is not yet feasible, such as the surface of Mars. In addition, the lack of sample preparation needed here will simplify the sample acquisition process and allow caching of the samples for future complementary payload use.

Microscope↗

Langley Mobile Ozone Lidar: Ozone and Aerosol Atmospheric Profiling for Air Quality Research

The Langley mobile ozone lidar (LMOL) is a mobile ground-based ozone lidar system that consists of a pulsed UV laser producing two UV wavelengths of 286 and 291 nm with energy of approximately 0.2 mJ/pulse 0.2 mJ/pulse and repetition rate of 1 kHz. The 527 nm pump laser is also transmitted for aerosol measurements. The receiver consists of a 40 cm parabolic telescope, which is used for both backscattered analog and photon counting. The lidar is very compact and highly mobile. This demonstrates the utility of very small lidar systems eventually leading to space-based ozone lidars. The lidar has been validated by numerous ozonesonde launches and has provided ozone curtain profiles from ground to approximately 4 km in support of air quality field missions.

De Young, Russell↗