Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Signal Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Detection of vapor nanobubbles by small angle neutron scattering (SANS)

Experiments using boiling water on untreated (roughness 100–300 nm) metal surfaces using small-angle neutron scattering (SANS) show the appearance of structures that are 50–70 nm in size when boiling is present. The scattering signal disappears when the boiling ceases, and no change in the signal is detected at any surface temperature condition below saturation. This confirms that the signal is caused by vapor nanobubbles. Two boiling regimes are evaluated herein that differ by the degree of subcooling (3–10 °C). A polydisperse spherical model with a log-normal distribution fits the SANS data well. In conclusion, the size distribution indicates that a large number of nanobubbles exist on the surface during boiling, and some of them grow into large bubbles.

74 ATOMIC AND MOLECULAR PHYSICS↗

Biomimetic/Optical Sensors for Detecting Bacterial Species

Biomimetic/optical sensors have been proposed as means of real-time detection of bacteria in liquid samples through real-time detection of compounds secreted by the bacteria. Bacterial species of interest would be identified through detection of signaling compounds unique to those species. The best-characterized examples of quorum-signaling compounds are acyl-homoserine lactones and peptides. Each compound, secreted by each bacterium of an affected species, serves as a signal to other bacteria of the same species to engage in a collective behavior when the population density of that species reaches a threshold level analogous to a quorum. A sensor according to the proposal would include a specially formulated biomimetic film, made of a molecularly imprinted polymer (MIP), that would respond optically to the signaling compound of interest. The MIP film would be integrated directly onto an opticalwaveguide- based ring resonator for optical readout. Optically, the sensor would resemble the one described in Chemical Sensors Based on Optical Ring Resonators (NPO-40601), NASA Tech Briefs, Vol. 29, No. 10 (October 2005), page 32. MIPs have been used before as molecular- recognition compounds, though not in the manner of the present proposal. Molecular imprinting is an approach to making molecularly selective cavities in a polymer matrix. These cavities function much as enzyme receptor sites: the chemical functionality and shape of a cavity in the polymer matrix cause the cavity to bind to specific molecules. An MIP matrix is made by polymerizing monomers in the presence of the compound of interest (template molecule). The polymer forms around the template. After the polymer solidifies, the template molecules are removed from the polymer matrix by decomplexing them from their binding sites and then dissolving them, leaving cavities that are matched to the template molecules in size, shape, and chemical functionality. The cavities thus become molecular-recognition sites that bind only to molecules matched to the sites; other molecules are excluded. In a sensor according to the proposal, the MIP would feature molecular recognition sites that would bind the specific signaling molecules selectively according to their size, shape, and chemical functionality (see figure). As the film took up the signaling molecules in the molecular recognition sites, the index of refraction and thickness of the film would change, causing a wavelength shift of the peak of the resonance spectrum. It has been estimated that by measuring this wavelength shift, it should be possible to detect as little as 10 picomoles of a peptide signaling compound.

Homer, Margie↗

Adaptive Thresholding and Parameter Estimation for PPM

A method of adaptive setting of a threshold level for the detection of pulses in a pulse-position modulation (PPM) free-space optical communication system has been developed. In simplified terms, it is desirable to set a threshold value high enough to greatly reduce the probability (PFA as defined below) of erroneously detecting noise as signal pulses but not so high as to greatly reduce the probability (PD as defined below) of detecting any signal pulses that may be present along with noise. In the present method, the threshold level is varied with time, in response to changing conditions in the optical-communication channel, in an effort to maintain a balance between the aforesaid competing requirements. An integral part of this adaptation scheme is a scheme for estimating key parameters of the optical-communication channel in particular, parameters that describe the fading and total attenuation in the channel, and parameters that characterize spreading of pulses by atmospheric and other effects. The method can be implemented by software processing of digitized optoelectronic-detector output, and has been tested by computational simulation. In the first stage of processing by this method, the digitized values of the detector output during noise-only time slots of received PPM symbols are averaged to obtain a background level. This background level is subtracted from the detector output in the hope of reducing or eliminating the noise component in the remaining signal. (This background level should not be confused with the detection threshold, which is computed in the last stage of processing.) Next, the remaining signal - in effect, a vector of pulse samples - is normalized by dividing it by its L1 norm (in general, the L1 norm of a vector is defined as the sum of absolute magnitudes of its orthogonal components).

Arabshahi, Payman↗

A comparative study of three-terminal Hanle signals in CoFe/SiO{sub 2}/n{sup +}-Si and Cu/SiO{sub 2}/n{sup +}-Si tunnel junctions

We performed three-terminal (3T) Hanle measurement for two types of sample series, CoFe/SiO{sub 2}/n{sup +}-Si and Cu/SiO{sub 2}/n{sup +}-Si, with various tunnel resistances. Clear Hanle signal and anomalous scaling between spin resistance-area product and tunnel resistance-area product were observed in CoFe/SiO{sub 2}/n{sup +}-Si devices. In order to explore the origin of the Hanle signal and the impurity-assisted tunneling effect on the Hanle signal in our devices, Hanle measurement in Cu/SiO{sub 2}/n{sup +}-Si devices was performed as well. However, no detectable Hanle signal was observed in Cu/SiO{sub 2}/n{sup +}-Si, even though a lot of samples with various tunnel resistances were studied in wide temperature and bias voltage ranges. Through a comparative study, it is found that the impurity-assisted tunneling magnetoresistance mechanism would not play a dominant role in the 3T Hanle signal in CoFe/SiO{sub 2}/n{sup +}-Si tunnel junctions, where the SiO{sub 2} was formed by plasma oxidation to minimize impurities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Constraints on MeV dark matter and primordial black holes: Inverse Compton signals at the SKA

Here we investigate the possibilities for probing MeV dark matter (DM) particles and primordial black holes (PBHs) (for masses ~ 10 15 –10 17 g) at the upcoming radio telescope SKA, using photon signals from the Inverse Compton (IC) effect within a galactic halo. Pair-annihilation or decay of MeV DM particles (into e + e - pairs) or Hawking radiation from a population of PBHs generates mildly relativistic e ± which can lead to radio signals through the IC scattering on low energy cosmic microwave background (CMB) photons. We study the ability of SKA to detect such signals coming from nearby ultra-faint dwarf galaxies Segue I and Ursa Major II as well as the globular cluster ω-cen and the Coma cluster. We find that with ~ 100 hours of observation, the SKA improves the Planck constraints on the DM annihilation/decay rate and the PBH abundance for masses in the range ~ 1 to few tens of MeV and above 10 15 to 10 17 g, respectively. Importantly, the SKA limits are independent of the assumed magnetic fields within the galaxies. Previously allowed regions of diffusion parameters of MeV electrons inside a dwarf galaxy that give rise to observable signals at the SKA are also excluded. For objects like dwarf galaxies, predicted SKA constraints depend on both the DM and diffusion parameters. Independent observations in different frequency bands, e.g., radio and γ-ray frequencies, may break this degeneracy and thus enable one to constrain the combined parameter space of DM and diffusion. However, the constraints are independent of diffusion parameters for galaxy clusters such as Coma.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Controlling Electron-Beam-Weld Focus

Control loop measures weld-spot temperature to regulate focus current. Square-wave generator modulates current in electron-beam focus coil so that focal point is varied between points slightly above and below surface of weld. Sensor detects intensity of light emitted by weld, proportional to fourth power of temperature at hottest part of weld spot. Sensor signal is detected by chopper demodulator synchronized by square-wave generator, to determine whether average position of focal point is higher than, coincident with, or lower than optimum point; and focus coil current is adjusted accordingly.

Coate, F. M.↗

Mars Global Surveyor Ka-Band Frequency Data Analysis

The Mars Global Surveyor (MGS) spacecraft, launched on November 7, 1996, carries an experimental space-to-ground telecommunications link at Ka-band (32 GHz) along with the primary X-band (8.4 GHz) downlink. The signals are simultaneously transmitted from a 1.5-in diameter parabolic high gain antenna (HGA) on MGS and received by a beam-waveguide (BWG) R&D 34-meter antenna located in NASA's Goldstone Deep Space Network (DSN) complex near Barstow, California. The projected 5-dB link advantage of Ka-band relative to X-band was confirmed in previous reports using measurements of MGS signal strength data acquired during the first two years of the link experiment from December 1996 to December 1998. Analysis of X-band and Ka-band frequency data and difference frequency (f(sub x)-f(sub ka)/3.8) data will be presented here. On board the spacecraft, a low-power sample of the X-band downlink from the transponder is upconverted to 32 GHz, the Ka-band frequency, amplified to I-W using a Solid State Power Amplifier, and radiated from the dual X/Ka HGA. The X-band signal is amplified by one of two 25 W TWTAs. An upconverter first downconverts the 8.42 GHz X-band signal to 8 GHz and then multiplies using a X4 multiplier producing the 32 GHz Ka-band frequency. The frequency source selection is performed by an RF switch which can be commanded to select a VCO (Voltage Controlled Oscillator) or USO (Ultra-Stable Oscillator) reference. The Ka-band frequency can be either coherent with the X-band downlink reference or a hybrid combination of the USO and VCO derived frequencies. The data in this study were chosen such that the Ka-band signal is purely coherent with the X-band signal, that is the downconverter is driven by the same frequency source as the X-band downlink). The ground station used to acquire the data is DSS-13, a 34-meter BWG antenna which incorporates a series of mirrors inside beam waveguide tubes which guide the energy to a subterranean pedestal room, providing a stable environment for the feed and electronics equipment. A dichroic plate is used to reflect the X-band energy and pass the Ka-band energy to another mirror. The RF energy for each band is then focused onto a feed horn and low-noise amplifier package. After amplification and RF/IF downconversion, the IF signals are sent to the Experimental Tone Tracker (ETT), a digital phase-lock-loop receiver, which simultaneously tracks both X-band and Ka-band carrier signals. Once a signal is detected, the ETT outputs estimates of the SNR in a I -Hz bandwidth (Pc/No), baseband phase and frequency of the signals every I -sec. Between December 1996 and December 1998, the Ka-band and X-band signals from MGS were tracked on a regular basis using the ETT. The Ka-band downlink frequencies described here were referenced to the spacecraft's on-board USO which was also the X-band frequency reference (f(sub ka)= 3.8 f(sub x)). The ETT estimates of baseband phase at I -second sampled time tags were converted to sky frequency estimates. Frequency residuals were then generated for each band by removing a model frequency from each observable frequency at each time tag. The model included Doppler and other effects derived from spacecraft trajectory files obtained from the MGS Navigation Team. A simple troposphere correction was applied to the data. In addition to residuals, the USO frequencies emitted by the spacecraft were estimated. For several passes, the USO frequencies were determined from X-band data and from Ka-band data (referred to X-band by dividing by 3.8) and were found to be in good agreement. In addition, X-band USO frequency estimates from MGS Radio Science data acquired from operational DSN stations were available for comparison and were found to agree within the I Hz level. The remaining sub-Hertz differences were attributed to the different models and software algorithms used by MGS Radio Science and KaBLE-11. A summary of the results of a linear fit of the USO frequency versus time (day of year) is presented in Table I for an initial segment of passes.

Morabito, D.↗

Tensor Decomposition Analysis for UAV Anomaly Detection

Vibrational anomalies can provide valuable insights into the health status of an unmanned aerial vehicle, potentially indicating system degradation including propeller, motor, or sensor damage, as well as environmental anomalies such as strong wind gusts and turbulence. However, many causes for vibrational anomalies are not related to vehicle health, such as sharp shifts in velocity or direction of flight. Thus, depending strictly on vibration signals to detect anomalies can result in false positives for failures. Hence, it is important to include additional telemetries in detecting and diagnosing in-flight anomalies. This paper considers an approach to anomaly detection based on tensor decompositions that incorporates information from vibration signals, as well as additional flight data such as velocity, current draw, voltage drop, and attitude. Using experimental flight data collected by the University of Notre Dame, we construct third-order tensors then apply the CANDECOMP/PARAFAC decomposition to identify trends within each flight and classify flights as nominal or anomalous.

unmanned aviation↗

Analysis of the Source Physics Experiment Dry Alluvium Geology Ball Drop Sources

Two balls were dropped approximately 150 m down an open borehole as part of an investigation into the aftershocks from a 51 ton TNT-equivalent chemical explosion. The ball drop sources, a concrete-filled basketball and a bowling ball, were intended to mimic falling debris within an underground explosion borehole and cavity. Falling debris or sloughing of the borehole and cavity walls is thought to be one of the sources of explosion aftershocks. The signals from the ball drop sources were recorded by the same seismic network that monitored the aftershocks of the chemical explosion, so the ball drop recordings were used as templates to search through the continuous stream of aftershocks and detect correlated signals as a proportion of all aftershocks. The search resulted in only four similar event recordings out of the thousands of detected aftershocks. A synthetic test showed that the small, high-frequency ball drop templates were limited to producing highly correlated detections for events occurring in a small region around the impact location at 150 m depth. The high-frequency templates were necessary since the small ball drop signals were only above the noise at frequencies greater than 10 Hz. Unfortunately, the impact location is where the borehole was filled with sand in preparation for the subsequent chemical explosion in the test series, making it 150 m above the explosion created cavity centered at 300 m depth. This puts the ball drop templates 150 m away from the cavity, where many more events from falling debris would be expected. Further synthetic tests confirmed events emanating from the cavity 150 m below the impact site would have correlated with the lower frequency template and been detected had the template been usable below 10 Hz. Therefore, we conclude that the four detected events were most probably falling debris within the open borehole that impacted the floor at 150 m depth just as the ball drop sources had, and that this type of explosion aftershock mechanism comprises less than 1% of all explosion aftershocks.

58 GEOSCIENCES↗

Ulysses observations of auroral hiss at high Jovian latitudes

During the Ulysses flyby of Jupiter, a whistler-mode emission was periodically detected by the unified Radio and Plasma wave (URAP) experiment during intervals when the spacecraft extended to high magnetic latitudes. The signal was detected between the local electron plasma frequency and lower hybrid resonance and appears as a funnel-shaped structure on frequency-versus-time spectrograms; these characteristics are very reminiscent of whistler-mode auroral hiss observed at high latitudes at Earth. Ray tracing of the emission occurrences suggests the emission source is on magnetic field lines extending out to at least 65 R(sub J). This location associates the emission with the boundary between open and closed field lines -- not the Io torus. The emission radiates about 10(exp 7) W of power. Consequently, the auroral input power derived from the solar wind to drive the emission is believed to be 10(exp 10-12) W (or about 1% of the energy associated with Io torus electrical processes).

Farrell, W. M.↗

Operational Performance Analysis of Passive Acoustic Monitoring for Killer Whales

For the planned tidal turbine site in Puget Sound, WA, the main concern is to protect Southern Resident Killer Whales (SRKW) due to their Endangered Species Act status. A passive acoustic monitoring system is proposed because the whales emit vocalizations that can be detected by a passive system. The algorithm for detection is implemented in two stages. The first stage is an energy detector designed to detect candidate signals. The second stage is a spectral classifier that is designed to reduce false alarms. The evaluation presented here of the detection algorithm incorporates behavioral models of the species of interest, environmental models of noise levels and potential false alarm sources to provide a realistic characterization of expected operational performance.

16 TIDAL AND WAVE POWER↗

Heartbeat: Detecting Malware by Periodic Power Signal Injection and Monitoring

Rootkits and other stealthy malware attempt to conceal their presence on a computer by making changes to the host computer’s operating environment. ORNL’s Heartbeat technology detects these changes, and thus the malware itself. Heartbeat operates by directly monitoring the DC power consumption of the computer while a set of operations, the “heartbeat,” is executed periodically. These operations exercise parts of the operating system that are common targets of malware tampering. The power consumption during these heartbeat events is monitored and then compared to a previously learned baseline, with any significant deviation detected and analyzed. This technology has been tested and validated in a laboratory environment, and ORNL is currently seeking a deployment partner to allow for further in-context development and testing of this technology.

97 MATHEMATICS AND COMPUTING↗

Detection of O-propargyl-puromycin with SUMO and ubiquitin by click chemistry at PML-nuclear bodies during abortive proteasome activities

The amino-nucleoside antibiotic, puromycin, acts by covalently linking to elongating polypeptide chains on ribosomes to generate prematurely terminated immature polypeptides. The trafficking of puromycin-conjugated (puromycylated) immature polypeptides within cell has, however, remained elusive. In this study, using O-propargyl-puromycin (OP-Puro), the distribution of puromycylated polypeptides was assessed in HeLa cells by click chemistry. Under standard culture conditions, OP-Puro signals were detected in the cytoplasm and nucleus with the highest concentrations in the nucleolus. Intriguingly, when proteasome activities were aborted using MG132, OP-Puro signals began to accumulate at promyelocytic leukemia nuclear bodies (PML-NBs) in addition to the nucleolus. We also found promiscuous association of OP-Puro signals with SUMO-2/3 and ubiquitin at PML-NBs, but not at the nucleolus, during abortive proteasome activities. This study reveals a previously unknown distribution of OP-Puro that argues for a nuclear function in regulating immature protein homeostasis. -- Highlights: •Click chemistry detects O-propargyl-puromycin (OP-Puro) signals in the nucleus. •OP-Puro accumulates at PML-NBs during abortive proteasome activities. •SUMO and ubiquitin are promiscuously associated with OP-Puro at PML-NBs. •The nucleus may function in immature protein homeostasis.

60 APPLIED LIFE SCIENCES↗

Development of an airborne laser bathymeter

An airborne laser depth sounding system was built and taken through a complete series of field tests. Two green laser sources were tried: a pulsed neon laser at 540 nm and a frequency-doubled Nd:YAG transmitter at 532 nm. To obtain a depth resolution of better than 20 cm, the pulses had a duration of 5 to 7 nanoseconds and could be fired up to at rates of 50 pulses per second. In the receiver, the signal was detected by a photomultiplier tube connected to a 28 cm diameter Cassegrainian telescope that was aimed vertically downward. Oscilloscopic traces of the signal reflected from the sea surface and the ocean floor could either be recorded by a movie camera on 35 mm film or digitized into 500 discrete channels of information and stored on magnetic tape, from which depth information could be extracted. An aerial color movie camera recorded the geographic footprint while a boat crew of oceanographers measured depth and other relevant water parameters. About two hundred hours of flight time on the NASA C-54 airplane in the area of Chincoteague, Virginia, the Chesapeake Bay, and in Key West, Florida, have yielded information on the actual operating conditions of such a system and helped to optimize the design. One can predict the maximum depth attainable in a mission by measuring the effective attenuation coefficient in flight. This quantity is four times smaller than the usual narrow beam attenuation coefficient. Several square miles of a varied underwater landscape were also mapped.

Kim, H., H.↗

Vibration detection of component operability

In order to prevent catastrophic failure and eliminate unnecessary periodic maintenance in the Space Shuttle Orbiter dynamic components, instrumentation for detecting incipient failure in these components is required. This study investigated the utilization of vibrational phenomena as one of the principal physical parameters on which to base the design of this instrumentation. Baseline vibration data was collected from three aircraft type fans and two aircraft type pumps over a frequency range from a few Hertz to greater than 300 kHz. The baseline data included spectrum analysis of the vibration and detected carrier signals, as well as several non-spectrum parameters. Several defects were introduced into the five test items, and all defects were detected by at least one of the parameters with a margin of at least 2:1 over the worst case baseline.

Baird, B.↗

A photoelastic fiber optic strain gage

This paper reports on the development of a photoelastic fiber optic strain gage sensitive to transverse strain. The sensing element is made from an epoxy resin which is stress frozen to passively achieve the quadrature condition. Light, emitted from an LED operating at 820 nm, is transmitted to and from the sensing element via multimode fibers and the signal is detected using a dual channel operational photodiode/amplifier. This unique combination of optics and electronics produces a fiber optic sensor having a high signal to noise ratio which is lead-in/out insensitive. Results show that strains on the order of 1 microstrain can be measured over an 800 microstrain range and that dummy gages can be used for temperature compensation.

Su, Wei↗

Radio frequency strain monitor

A radio frequency strain monitor includes a voltage controlled oscillator for generating an oscillating signal that is input into a propagation path. The propagation path is preferably bonded to the surface of a structure to be monitored and produces a propagated signal. A phase difference between the oscillating and propagated signals is detected and maintained at a substantially constant value which is preferably a multiple of 90.degree. by changing the frequency of the oscillating signal. Any change in frequency of the oscillating signal provides an indication of strain in the structure to which the propagation path is bonded.

Heyman, Joseph S.↗

Principles of communication engineering.

Textbook on communication engineering emphasizing random processes, information and detection theory, statistical communication theory, applications, etc

COMMUNICATION THEORY↗