Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Safety”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

SU-D-BRD-06: Creating a Safety Net for a Fully Automated, Script Driven Electronic Medical Record

Purpose: Demonstrate the effectiveness of in-house software in ensuring EMR workflow efficiency and safety. Methods: A web-based dashboard system (WBDS) was developed to monitor clinical workflow in real time using web technology (WAMP) through ODBC (Open Database Connectivity). Within Mosaiq (Elekta Inc), operational workflow is driven and indicated by Quality Check Lists (QCLs), which is triggered by automation software IQ Scripts (Elekta Inc); QCLs rely on user completion to propagate. The WBDS retrieves data directly from the Mosaig SQL database and tracks clinical events in real time. For example, the necessity of a physics initial chart check can be determined by screening all patients on treatment who have received their first fraction and who have not yet had their first chart check. Monitoring similar “real” events with our in-house software creates a safety net as its propagation does not rely on individual users input. Results: The WBDS monitors the following: patient care workflow (initial consult to end of treatment), daily treatment consistency (scheduling, technique, charges), physics chart checks (initial, EOT, weekly), new starts, missing treatments (>3 warning/>5 fractions, action required), and machine overrides. The WBDS can be launched from any web browser which allows the end user complete transparency and timely information. Since the creation of the dashboards, workflow interruptions due to accidental deletion or completion of QCLs were eliminated. Additionally, all physics chart checks were completed timely. Prompt notifications of treatment record inconsistency and machine overrides have decreased the amount of time between occurrence and execution of corrective action. Conclusion: Our clinical workflow relies primarily on QCLs and IQ Scripts; however, this functionality is not the panacea of safety and efficiency. The WBDS creates a more thorough system of checks to provide a safer and near error-less working environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-785: Using Systems Engineering to Design HDR Skin Treatment Operation for Small Lesions to Enhance Patient Safety

Purpose: Using systems engineering to design HDR skin treatment operation for small lesions using shielded applicators to enhance patient safety. Methods: Systems engineering is an interdisciplinary field that offers formal methodologies to study, design, implement, and manage complex engineering systems as a whole over their life-cycles. The methodologies deal with human work-processes, coordination of different team, optimization, and risk management. The V-model of systems engineering emphasize two streams, the specification and the testing streams. The specification stream consists of user requirements, functional requirements, and design specifications while the testing on installation, operational, and performance specifications. In implementing system engineering to this project, the user and functional requirements are (a) HDR unit parameters be downloaded from the treatment planning system, (b) dwell times and positions be generated by treatment planning system, (c) source decay be computer calculated, (d) a double-check system of treatment parameters to comply with the NRC regulation. These requirements are intended to reduce human intervention to improve patient safety. Results: A formal investigation indicated that the user requirements can be satisfied. The treatment operation consists of using the treatment planning system to generate a pseudo plan that is adjusted for different shielded applicators to compute the dwell times. The dwell positions, channel numbers, and the dwell times are verified by the medical physicist and downloaded into the HDR unit. The decayed source strength is transferred to a spreadsheet that computes the dwell times based on the type of applicators and prescribed dose used. Prior to treatment, the source strength, dwell times, dwell positions, and channel numbers are double-checked by the radiation oncologist. No dosimetric parameters are manually calculated. Conclusion: Systems engineering provides methodologies to effectively design the HDR treatment operation that minimize human intervention and improve patient safety.

60 APPLIED LIFE SCIENCES↗

SU-F-P-10: A Web-Based Radiation Safety Relational Database Module for Regulatory Compliance

Purpose: Maintaining compliance with Radioactive Materials Licenses is inherently a time-consuming task requiring focus and attention to detail. Staff tasked with these responsibilities, such as the Radiation Safety Officer and associated personnel must retain disparate records for eventual placement into one or more annual reports. Entering results and records in a relational database using a web browser as the interface, and storing that data in a cloud-based storage site, removes procedural barriers. The data becomes more adaptable for mining and sharing. Methods: Web-based code was written utilizing the web framework Django, written in Python. Additionally, the application utilizes JavaScript for front-end interaction, SQL, HTML and CSS. Quality assurance code testing is performed in a sequential style, and new code is only added after the successful testing of the previous goals. Separate sections of the module include data entry and analysis for audits, surveys, quality management, and continuous quality improvement. Data elements can be adapted for quarterly and annual reporting, and for immediate notification of user determined alarm settings. Results: Current advances are focusing on user interface issues, and determining the simplest manner by which to teach the user to build query forms. One solution has been to prepare library documents that a user can select or edit in place of creation a new document. Forms are being developed based upon Nuclear Regulatory Commission federal code, and will be expanded to include State Regulations. Conclusion: Establishing a secure website to act as the portal for data entry, storage and manipulation can lead to added efficiencies for a Radiation Safety Program. Access to multiple databases can lead to mining for big data programs, and for determining safety issues before they occur. Overcoming web programming challenges, a category that includes mathematical handling, is providing challenges that are being overcome.

61 RADIATION PROTECTION AND DOSIMETRY↗

Influence of the safety factor inhomogeneity on collisionless current generation in tokamaks

An improved scaling for the current density generated due to collisionless motion of {alpha}-particles in a tokamak is proposed. The dependence of the current density on the radial profile of the safety factor q is investigated. Monotonically increasing q profiles are considered, as well as q profiles with a minimum in the axial region of the plasma column. It is shown that the current density depends on the variation in q along the charged particle trajectories, rather than on the q value at the starting magnetic surface. The dependence of the current density on the gradient of q is strongest in the plasma core because of the large deviation of the drift surfaces from the magnetic ones in this region. At the plasma edge, the larger the second derivative of the plasma density, the greater the contribution of the gradient of q. For conventional plasma density profiles, the poloidal-angle-averaged current density calculated for a varying safety factor q is always lower than that calculated for a constant q. The effect of the nonuniformity of the safety factor on the current generation at the magnetic axis of a tokamak is investigated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a leading simulator/trailing simulator methodology as part of an integrated safety-security analysis for nuclear power plants

Nuclear power plant (NPP) risk assessment is broadly separated into disciplines of nuclear safety, security, and safeguards. Different analysis methods and computer models have been constructed to analyze each of these as separate disciplines. However, due to the complexity of NPP systems, there are risks that can span all these disciplines and require consideration of safety-security (2S) interactions which allows a more complete understanding of the relationship among these risks. In this work, a novel leading simulator/trailing simulator (LS/TS) method is introduced to integrate multiple generic safety and security computer models into a single, holistic 2S analysis. A case study is performed using this novel method to determine its effectiveness. The case study shows that the LS/TS method avoided introducing errors in simulation, compared to the same scenario performed without the LS/TS method. A second case study is then used to illustrate an integrated 2S analysis which shows that different levels of damage to vital equipment from sabotage at a NPP can affect accident evolution by several hours.

42 ENGINEERING↗

SCALE 6: Comprehensive Nuclear Safety Analysis Code System

Version 6 of the Standardized Computer Analyses for Licensing Evaluation (SCALE) computer software system developed at Oak Ridge National Laboratory, released in February 2009, contains significant new capabilities and data for nuclear safety analysis and marks an important update for this software package, which is used worldwide. This paper highlights the capabilities of the SCALE system, including continuous-energy flux calculations for processing multigroup problem-dependent cross sections, ENDF/B-VII continuous-energy and multigroup nuclear cross-section data, continuous-energy Monte Carlo criticality safety calculations, Monte Carlo radiation shielding analyses with automated three-dimensional variance reduction techniques, one- and three-dimensional sensitivity and uncertainty analyses for criticality safety evaluations, two- and three-dimensional lattice physics depletion analyses, fast and accurate source terms and decay heat calculations, automated burnup credit analyses with loading curve search, and integrated three-dimensional criticality accident alarm system analyses using coupled Monte Carlo criticality and shielding calculations.

99 GENERAL AND MISCELLANEOUS↗

Treatment of Passive Component Reliability in Risk-Informed Safety Margin Characterization FY 2010 Report

The Risk-Informed Safety Margin Characterization (RISMC) pathway is a set of activities defined under the U.S. Department of Energy (DOE) Light Water Reactor Sustainability Program. The overarching objective of RISMC is to support plant life-extension decision-making by providing a state-of-knowledge characterization of safety margins in key systems, structures, and components (SSCs). A technical challenge at the core of this effort is to establish the conceptual and technical feasibility of analyzing safety margin in a risk-informed way, which, unlike conventionally defined deterministic margin analysis, is founded on probabilistic characterizations of SSC performance.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Secondary Protection for 70 MPa Fueling - A White Paper from the Hydrogen Safety Panel

In developing a 70 megapascal (MPa) fueling infrastructure, it is critical to ensure that a vehicle equipped with a lower service pressure fuel tank is never filled from a 70 MPa fueling source. Filling of a lower service pressure vehicle at a 70 MPa fueling source is likely to result in a catastrophic event with severe injuries or fatalities. The Hydrogen Safety Panel recommends that DOE undertake a two-step process to address this issue: 1. Perform an independent risk analysis of a 70MPa dispenser filling a lower pressure vehicle tank and develop different approaches for prevention and mitigation to meet an acceptable level of safety. Cost effectiveness, reliability, advantages and disadvantages are among the factors that should be evaluated for each approach considered. 2. Until such time as this analysis is complete and any recommended actions implemented, communicate the potential risk to responsible parties and strongly encourage those parties to add a secondary layer of protection to the existing system of mechanically non-interchangeable nozzles/receptacles. This will reduce the probability of a pressure mismatch during this developmental phase for hydrogen fuel cell vehicles and infrastructure. This step can be reassessed after further analysis is completed and the need and effectiveness of secondary protection methods are evaluated. This paper provides background discussion of the problem, current safety systems and strategy and examples of potential future solutions to support the above recommendations.

08 HYDROGEN↗

Environment, Safety and Health Self-Assessment Report Fiscal Year 2010

The Lawrence Berkeley National Laboratory (LBNL) Environment, Safety, and Health (ES&H) Self-Assessment Program was established to ensure that Integrated Safety Management (ISM) is implemented institutionally and by all divisions. The ES&H Self-Assessment Program, managed by the Office of Contractor Assurance (OCA), provides for an internal evaluation of all ES&H programs and systems at LBNL. The primary objective of the program is to ensure that work is conducted safely and with minimal negative impact to workers, the public, and the environment. Self-assessment follows the five core functions and guiding principles of ISM. Self-assessment is the mechanism used to promote the continuous improvement of the Laboratory's ES&H programs. The process is described in the Environment, Safety, and Health Assurance Plan (PUB-5344) and is composed of three types of self-assessments: Division ES&H Self-Assessment, ES&H Technical Assurance Program Assessment, and Division ES&H Peer Review. The Division ES&H Self-Assessment Manual (PUB-3105) provides the framework by which divisions conduct formal ES&H self-assessments to systematically identify program deficiencies. Issue-specific assessments are designed and implemented by the divisions and focus on areas of interest to division management. They may be conducted by teams and involve advance planning to ensure that appropriate resources are available. The ES&H Technical Assurance Program Manual (PUB-913E) provides the framework for systematic reviews of ES&H programs and processes. The ES&H Technical Assurance Program Assessment is designed to evaluate whether ES&H programs and processes are compliant with guiding regulations, are effective, and are properly implemented by LBNL divisions. The Division ES&H Peer Review Manual provides the framework by which division ISM systems are evaluated and improved. Peer Reviews are conducted by teams under the direction of senior division management and focus on higher-level management issues. Peer Review teams are selected on the basis of members knowledge and experience in the issues of interest to the division director. LBNL periodically requests in-depth independent assessments of selected ES&H programs. Such assessments augment LBNL's established assessment processes and provide an objective view of ES&H program effectiveness. Institutional Findings, Observations, and Noteworthy Practices identified during independent assessments are specifically intended to help LBNL identify opportunities for program improvement. This report includes the results of the Division ES&H Self-Assessment, ES&H Technical Assurance Program Assessment, and Division ES&H Peer Review, respectively.

99 GENERAL AND MISCELLANEOUS↗

Final Report: Weatherization and Energy Conservation Education and Home Energy and Safety Review in the Aleutian Islands

Aleutian/Pribilof Islands Association, Inc. (APIA) hired three part-time local community members that desire to be Energy Technicians. The energy technicians were trained in methods of weatherization assistance, energy conservation and home safety. They developed a listing of homes in the region that required weatherization, and conducted on-site weatherization and energy conservation education and a home energy and safety reviews in the communities of Akutan, False Pass, King Cove and Nelson Lagoon. Priority was given to these smaller communities as they tend to have the residences most in need of weatherization and energy conservation measures. Local residents were trained to provide all three aspects of the project: weatherization, energy conservation education and a home energy and safety review. If the total energy saved by installing these products is a 25% reduction (electrical and heating, both of which are usually produced by combustion of diesel fuel), and the average Alaska home produces 32,000 pounds of CO2 each year, so we have saved about: 66 homes x 16 tons of CO2 each year x .25 = 264 tons of CO2 each year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Safety analysis of high pressure 3He-filled micro-channels for thermal neutron detection.

This document is a safety analysis of a novel neutron detection technology developed by Sandia National Laboratories. This technology is comprised of devices with tiny channels containing high pressure {sup 3}He. These devices are further integrated into large scale neutron sensors. Modeling and preliminary device testing indicates that the time required to detect the presence of special nuclear materials may be reduced under optimal conditions by several orders of magnitude using this approach. Also, these devices make efficient use of our {sup 3}He supply by making individual devices more efficient and/or extending the our limited {sup 3}He supply. The safety of these high pressure devices has been a primary concern. We address these safety concerns for a flat panel configuration intended for thermal neutron detection. Ballistic impact tests using 3 g projectiles were performed on devices made from FR4, Silicon, and Parmax materials. In addition to impact testing, operational limits were determined by pressurizing the devices either to failure or until they unacceptably leaked. We found that (1) sympathetic or parasitic failure does not occur in pressurized FR4 devices (2) the Si devices exhibited benign brittle failure (sympathetic failure under pressure was not tested) and (3) the Parmax devices failed unacceptably. FR4 devices were filled to pressures up to 4000 + 100 psig, and the impacts were captured using a high speed camera. The brittle Si devices shattered, but were completely contained when wrapped in thin tape, while the ductile FR4 devices deformed only. Even at 4000 psi the energy density of the compressed gas appears to be insignificant compared to the impact caused by the incoming projectile. In conclusion, the current FR4 device design pressurized up to 4000 psi does not show evidence of sympathetic failure, and these devices are intrinsically safe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Idaho National Laboratory Integrated Safety Management System 2011 Effectiveness Review and Declaration Report

Idaho National Laboratory (INL) performed an annual Integrated Safety Management System (ISMS) effectiveness review per 48 Code of Federal Regulations (CFR) 970.5223-1, 'Integration of Environment, Safety and Health into Work Planning and Execution.' The annual review assessed Integrated Safety Management (ISM) effectiveness, provided feedback to maintain system integrity, and helped identify target areas for focused improvements and assessments for fiscal year (FY) 2012. The information presented in this review of FY 2011 shows that the INL has performed many corrective actions and improvement activities, which are starting to show some of the desired results. These corrective actions and improvement activities will continue to help change culture that will lead to better implementation of defined programs, resulting in moving the Laboratory's performance from the categorization of 'Needs Improvement' to the desired results of 'Effective Performance.'

99 GENERAL AND MISCELLANEOUS↗

AGR-1 Safety Test Predictions using the PARFUME code

The PARFUME modeling code was used to predict failure probability of TRISO-coated fuel particles and diffusion of fission products through these particles during safety tests following the first irradiation test of the Advanced Gas Reactor program (AGR-1). These calculations support the AGR-1 Safety Testing Experiment, which is part of the PIE effort on AGR-1. Modeling of the AGR-1 Safety Test Predictions includes a 620-day irradiation followed by a 300-hour heat-up phase of selected AGR-1 compacts. Results include fuel failure probability, palladium penetration, and fractional release of fission products. Results show that no particle failure is predicted during irradiation or heat-up, and that fractional release of fission products is limited during irradiation but that it significantly increases during heat-up.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Vehicle Battery Safety Roadmap Guidance

The safety of electrified vehicles with high capacity energy storage devices creates challenges that must be met to assure commercial acceptance of EVs and HEVs. High performance vehicular traction energy storage systems must be intrinsically tolerant of abusive conditions: overcharge, short circuit, crush, fire exposure, overdischarge, and mechanical shock and vibration. Fail-safe responses tothese conditions must be designed into the system, at the materials and the system level, through selection of materials and safety devices that will further reduce the probability of single cell failure and preclude propagation of failure to adjacent cells. One of the most important objectives of DOE's Office of Vehicle Technologies is to support the development of lithium ion batteries thatare safe and abuse tolerant in electric drive vehicles. This Roadmap analyzes battery safety and failure modes of state-of-the-art cells and batteries and makes recommendations on future investments that would further DOE's mission.

25 ENERGY STORAGE↗

CSM 1576: Criticality Safety Evaluation of a New 3013 Calorimeter for Use Under OSP 332.032

Materials Management (MM) has purchased a new calorimeter to be used in B332, Room 1314A under Operational Safety Plan (OSP) 332.032, Nuclear Material Measurements. Calorimeters quantitatively measure the decay heat produced by fissionable material to verify the fissionable mass of items for Material Control and Accountability (MC&A). The new commercially available calorimeter, the Setaram Large Volume air bath Calorimeter (LVC) 3013, was specially designed for measuring 3013 cans. Operations have requested Standard Criticality Control Conditions (SCCCs) consistent with the other calorimeters and MC&A workstations covered by OSP 332.032. This report documents the criticality safety evaluation of the new LVC 3013 with SCCCs A, V1, V2, and V6. An addendum to this evaluation, CSM 1576, Addendum 1, Criticality Safety Evaluation of Approved Items for LVC 3013 under OSP 332.032 (U), provides the technical basis for SCCC V3 and the accompanying approved item list from OSP 332.032.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Idaho National Laboratory Integrated Safety Management System FY 2013 Effectiveness Review and Declaration Report

Idaho National Laboratory (INL) performed an Annual Effectiveness Review of the Integrated Safety Management System (ISMS), per 48 Code of Federal Regulations (CFR) 970.5223 1, “Integration of Environment, Safety and Health into Work Planning and Execution.” The annual review assessed Integrated Safety Management (ISM) effectiveness, provided feedback to maintain system integrity, and identified target areas for focused improvements and assessments for Fiscal Year (FY) 2014. Results of the FY 2013 annual effectiveness review demonstrate that the INL’s ISMS program is “Effective” and continually improving and shows signs of being significantly strengthened. Although there have been unacceptable serious events in the past, there has also been significant attention, dedication, and resources focused on improvement, lessons learned and future prevention. BEA’s strategy of focusing on these improvements includes extensive action and improvement plans that include PLN 4030, “INL Sustained Operational Improvement Plan, PLN 4058, “MFC Strategic Excellence Plan,” PLN 4141, “ATR Sustained Excellence Plan,” and PLN 4145, “Radiological Control Road to Excellence,” and the development of LWP 20000, “Conduct of Research.” As a result of these action plans, coupled with other assurance activities and metrics, significant improvement in operational performance, organizational competence, management oversight and a reduction in the number of operational events is being realized. In short, the realization of the fifth core function of ISMS (feedback and continuous improvement) and the associated benefits are apparent.

99 GENERAL AND MISCELLANEOUS↗

Hydrogen Technologies Safety Guide

The purpose of this guide is to provide basic background information on hydrogen technologies. It is intended to provide project developers, code officials, and other interested parties the background information to be able to put hydrogen safety in context. For example, code officials reviewing permit applications for hydrogen projects will get an understanding of the industrial history of hydrogen, basic safety concerns, and safety requirements.

08 HYDROGEN↗

RPP-PRT-58489, Revision 1, One Systems Consistent Safety Analysis Methodologies Report. 24590-WTP-RPT-MGT-15-014

In 2012, One System Nuclear Safety performed a comparison of the safety bases for the Tank Farms Operations Contractor (TOC) and Hanford Tank Waste Treatment and Immobilization Plant (WTP) (RPP-RPT-53222 / 24590-WTP-RPT-MGT-12-018, “One System Report of Comparative Evaluation of Safety Bases for Hanford Waste Treatment and Immobilization Plant Project and Tank Operations Contract”), and identified 25 recommendations that required further evaluation for consensus disposition. This report documents ten NSSC approved consistent methodologies and guides and the results of the additional evaluation process using a new set of evaluation criteria developed for the evaluation of the new methodologies.

61 RADIATION PROTECTION AND DOSIMETRY↗