Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SERVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

LLNL ES&H Analytical Services and Instrumentation Analytical Laboratory (ALAB) (CY2022 Management Review Report)

"An annual review shall be conducted of the analytical activities to ensure continuing suitability, adequacy, and effectiveness." (ALAB-01 Rev 6 ALQAP section 6.11.2) "The laboratory management shall review its management system at planned intervals, in order to ensure its continuing suitability, adequacy and effectiveness..."(ISO/IEC 17025:2017 Section 8.9.1) "In accordance with a predetermined schedule and procedure, the laboratory's top management shall periodically conduct a review of the laboratory's management system and testing and/or calibration activities to ensure their continuing suitability and effectiveness, and to introduce necessary changes or improvements. "(TNI Standard EL-V1M2-2016-Rev2.1:Quality Systems General Requirements)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Responses to International Accrediting Services (IAS) Biennial Onsite Assessment of ALAB to CA ELAP Requirements

The purpose of this assessment was to perform an evaluation of the laboratory’s quality system, capabilities, and personnel qualifications to determine the extent of conformance to the current TNI standards and the rules enacted by the 2020 California Environmental Laboratory Accreditation Program (ELAP) for accreditation of environmental laboratories. The scope of the assessment included the California Code, Health and Safety Code – HSC § 100829 and 100830, the 2016 TNI-2 requirements, published methods, and the laboratory’s Quality Management System including administrative and technical operating procedures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Transactive Campus Energy Systems: An R&D Testbed for Renewalables Integration, Efficiency, and Grid Services - CRADA 356 (Abstract)

Under this Cooperative Research and Development Agreement (CRADA), the project team consisting of Pacific Northwest National Laboratory (PNNL), acting on behalf of the U.S. Department of Energy, and the University of Washington (UW) and Washington State University (WSU), acting under the purview of the State of Washington’s Department of Commerce (the “industrial” partner), will connect the PNNL, UW, and WSU campuses to form a multi-campus test bed for transaction-based energy management – transactive – solutions (see sidebar). Building on the foundational transactive system established by the Pacific Northwest Smart Grid Demonstration (PNWSGD), it is proposing to construct the test bed as both a regional flexibility resource and as a platform for R&D on buildings/grid integration and information-based energy efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mechanical Failure Risk Management for In-Service CSP Nitrate Hot Tanks

The hot thermal energy storage tanks in many operating (Gen2) concentrating solar power plants are designed to contain molten nitrate solar salt at 565 Degrees Celsius and are constructed from 347H stainless steel (SS). From previous work, it is known that 347H SS weldments are potentially susceptible to stress-relaxation cracking (SRC), particularly in the heat-affected zone above 540 Degrees Celsius when no post-weld heat-treatment (PWHT) is performed. However, residual stresses can be reduced when weldments receive PWHT, while at the same time a crack-resistant microstructure is being generated. The overarching goal of this project was to optimize cost-effective, thickness-dependent, localized PWHT procedures and to investigate for feasible non-destructive evaluation (NDE) at commercial scale for hot tanks in Gen2 CSP using 347H SS.

14 SOLAR ENERGY↗

Los Alamos National Laboratory Transit Service Implementation Plan

In 2021, Los Alamos National Laboratory (LANL) partnered with Nelson\Nygaard Consulting Associates to conduct the LANL Transit Options Study in preparation for Laboratory expansion plans. When the study started, LANL was expected to grow by 3,000 employees over the next several years. Most of that growth has already taken place. Sixty percent of employees commute from outside of Los Alamos County, and with limited housing capacity in Los Alamos, most of the new employees are expected to live outside of Los Alamos County as well.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Plutonium-238 Loadout Calorimeter Return To Service

The calorimeter in the transfer area in Building 7920 at the US Department of Energy’s Oak Ridge National Laboratory is used to measure the amount of 238 Pu in the Plutonium Heat Source Oxide. The calorimetry measurement is taken after the oxide is packaged in an ORISC (Oak Ridge Inner Shipping Capsule)/FSO (Fuel Storage Outer) assembly before loading into the Containment Vessel and shipping container. The equipment is used in three specific configurations: zero measurement (nothing in the sample cup), FSO measurement (actual measurement of 238 Pu), and reference calibration measurement (using the reference FSO as a known heat source). System checks were performed in July 2023 in preparation for scheduled material loadout. During these checks, personnel discovered that the reference FSO had experienced an electrical short in the heater cable and was no longer functional. The calorimeter was in the reference calibration measurement configuration at this time. Facility management was notified when the damage was discovered. The data from the Yokogawa recorder were pulled and analyzed for a span of time between September 2022 and July 2023. An unusual spike was found in the sample cup temperature data that started on October 19, 2022, and ended on October 20, 2022. The sample cup reached a temperature of 191.1°C. The maximum allowable temperature for the calorimeter thermopile to reach is 220°C based on the manufacturer statement provided in Appendix B of this report [1]. The calorimeter thermopile and the sample cup thermocouple are physically close to each other; therefore, the data suggest that the calorimeter itself never saw a temperature in excess of 191.1°C. Physical damage present on the cable, tape, and insulation suggests that the temperature reached a higher value in some locations within the sample cup than the data shows. Because of this discrepancy, testing of the calorimeter was required to confirm that the calorimeter is functioning the same as it was before the electrical short. The intent of this report is to assess the functionality of the calorimeter and determine if it is acceptable to use for 238 Pu loadout material measurement. Testing showed that the calorimeter is functionally equivalent to the initial calibration that was performed in the summer of 2021, and thus, the calorimeter was cleared to be used for its intended purposes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-service Oxidation and IASCC in High Fluence Baffle-Former Bolts Retrieved from a Westinghouse PWR

Baffle-former bolts (BFBs) are subjected to significant mechanical stress and neutron irradiation from the reactor core during the plant operation. Over the long operation period, these conditions lead to potential degradation and reduced load-carrying capacity of the bolts, and life extension of existing pressurized water reactors (PWRs) would only cause more damage to the bolt material. To this end, the Light Water Reactor Sustainability (LWRS) Program Materials Research Pathway (MRP) successfully harvested two high fluence BFBs from a Westinghouse two-loop downflow type PWR in 2016. In the same year, the two BFBs were received at the Westinghouse Churchill facility for inspection and specimen fabrication. The fabrication was completed in 2017 with specimens shipped to Oak Ridge National Laboratory (ORNL) for further testing. The objective of this project is to provide information that is integral to evaluating end of life microstructure and properties as a benchmark of international models developed for predicting radiation-induced swelling, segregation, precipitation, mechanical property degradation, and with the latest findings, susceptibility to irradiation-assisted stress corrosion cracking (IASCC).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Framework for Identifying Building Energy Models of Localized Utility Service Areas Using Smart Meter Data

Bottom-up load modeling of buildings offers a versatile approach to simulating baseline demand and scenarios of future technology evolution and adoption at the individual building level. This capability is essential to understanding how future load shapes may change with the adoption of electric equipment and vehicles, particularly as it relates to grid planning and infrastructure investments. Traditionally, grid planning techniques have used historical load data to predict future load and infrastructure needs. However, with the anticipated rise in adoption of electrification technologies such as heat pumps and electric vehicles, historical data become less reliable predictors of the future. By employing ResStock, a high-fidelity building stock modeling tool, we can fine-tune electrification scenarios and aggregate models to represent varying geographic resolutions of the grid system, while considering the underlying features of homes. This may enable a more accurate and responsive approach to anticipate and plan for the evolving landscape of energy demands. We present a new framework that leverages building stock energy modeling to identify building models that align with the load shapes and housing attributes of buildings with AMI data. This approach applies two model layers: (1) a classification step that identifies the presence of air conditioning, electric heating, and electric water heating, and (2) an optimization routine that identifies building energy models aligning with load profile data from advanced metering infrastructure meters. This report demonstrates one approach to deploying this framework, and presents results for three test cases that use both modeled and AMI data to assess performance. For a test case using AMI data in Fort Collins, Colorado, we observed a median monthly electricity load CV-RMSE of 16.6%, and a top ten daily heating and cooling median absolute percent error of 7.7% and 8.3%, respectively. For each AMI meter, we identify a set of potential energy models so that downstream use-cases can account for uncertainty driven by variability of baseline technologies and occupant behavior, which impact the response to electrification and energy efficiency scenarios. Our results indicate that ResStock has potential as a scalable solution for modeling residential energy demand at local grid resolutions. Its performance depends on location-specific factors, underlying building characteristics, and the level of aggregation, offering a path towards more precise and adaptive distribution grid planning for the evolving energy landscape.

24 POWER TRANSMISSION AND DISTRIBUTION↗