Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Retrofitting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Durable Airtightness in Single-Family Dwellings - Field Measurementsand Analysis

Here, durability of the building envelope is important to new homes that are increasingly built with improved levels of airtightness. It is also important to weatherized homes such that energy savings from retrofit measures, such as air sealing, are persistent. This paper presents a comparison of air leakage measurements collected in November 2013 through March 2014, with two sets of prior data collected between 2001-2003 from 17 new homes located near Atlanta, GA, and 17 homes near Boise, ID that were weatherized in 2007- 2008. The purpose of the comparison is to determine if there are changes to the airtightness of building envelopes over time. The air leakage increased in all but one of the new homes, with a mean increase of about 25%. The weatherized homes also showed an increase in the mean air leakage (12%). A regression analysis was performed to describe the relationship between prior and current measurements in terms of normalized leakage (NL). The best estimate of the ageing factor predicts a 15% increase in NL over ten years. Further analysis using ResDB data (LBNL’s Residential Diagnostic Database) showed the expected changes in air leakage if ageing were modelled. These results imply the need to examine the causes of increased leakage and methods to avoid them. This increase in leakage with time should be accounted for in long-term population-wide energy savings estimates, such as those used in ratings or energy savings programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An open source analysis framework for large-scale building energy modeling

Full integration of building energy modelling into the design and retrofit process has long been a goal of building scientists and practitioners. However, significant barriers still exist. Among them are the lack of available: (1) configurable technology stacks for performing both small- and large-scale analyses, (2) different classes of algorithms compatible with common design workflows, and (3) analysis tools for effectively visualizing large-scale simulation results. This article discusses the OpenStudio® Analysis Framework: a scalable analysis framework for building energy modelling that was developed to overcome the three barriers listed above. The framework is open-source and scalable to facilitate wider adoption and has a clearly defined application programming interface upon which other applications can be built. It runs on high-performance computing systems, within cloud infrastructure, and on laptops, and uses a common workflow to enable different classes of algorithms. Lessons learned from previous development efforts are also discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Adaptation of fan motor and VFD efficiency correlations using Bayesian inference

Energy performance contracts (EPC) are types of agreements in which a service provider guarantees that customers’ buildings will achieve a specified energy performance (i.e., minimum energy savings) to reduce the risk of their investment in energy efficiency improvements. EPC requires prediction of future energy consumption of the building, at the design stage, before construction or major retrofit. To this end, building energy simulations taking into account all the major energy-using components are performed. In particular, fans can contribute significantly to the total building consumption. The overall efficiency of fans is the combination of three factors: mechanical, motor, and variable frequency drive (VFD). Manufacturers usually provide fan mechanical efficiency curves for a broad operating range. In contrast, motor and VFD efficiencies are generally given at rating conditions only. To represent part-load conditions, correlations are typically used to estimate motor and VFD efficiency variations, to evaluate the overall electricity consumption. The first aim of this study is to evaluate existing correlations for motor and VFD efficiency as a function of load and speed, by comparison with manufacturer data, for a vendor that has shared its detailed test data. While VFD efficiency correlations from the literature provide reasonable accuracy against real data, motor correlations under predict actual motor efficiency at low loads. Finally, the second aim of the paper is to improve such correlations using Bayesian inference to fit the available data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling of transient conduction in building envelope assemblies: A review

As buildings age, retrofits are becoming an increasingly important topic for the ever-growing and aging existing building stock. To compare designs or evaluate in-service building envelopes, thermal modeling is utilized to evaluate the thermal performance of envelope assemblies; however, it can be difficult to model the thermal performance of as-built assemblies due to degradation or missing documentation. To address this issue, inverse modeling can be applied to infer the properties of as-built envelope assemblies. This paper presents a review of the literature and published methods to model and infer the transient conductive performance of building envelopes. This review serves as a survey of existing transient conduction algorithms to evaluate performance, computational speed, and relevance for inverse modeling applications. In addition to the literature review, this work also evaluates the computational performance of the most prevalent transient conduction algorithms against the ASHRAE 1052RP toolkit to assess inverse modeling potential. This methodology serves as a foundation for future research to characterize the transient thermal performance of as-built building envelope assemblies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multiple gamma lines from semi-annihilation

Hints in the Fermi data for a 130 GeV gamma line from the galactic center have ignited interest in potential gamma line signatures of dark matter. Explanations of this line based on dark matter annihilation face a parametric tension since they often rely on large enhancements of loop-suppressed cross sections. In this paper, we pursue an alternative possibility that dark matter gamma lines could arise from ''semi-annihilation'' among multiple dark sector states. The semi-annihilation reaction ψ{sub i}ψ{sub j} → ψ{sub k}γ with a single final state photon is typically enhanced relative to ordinary annihilation ψ{sub i}ψ-bar {sub i} → γγ into photon pairs. Semi-annihilation allows for a wide range of dark matter masses compared to the fixed mass value required by annihilation, opening the possibility to explain potential dark matter signatures at higher energies. The most striking prediction of semi-annihilation is the presence of multiple gamma lines, with as many as order N{sup 3} lines possible for N dark sector states, allowing for dark sector spectroscopy. A smoking gun signature arises in the simplest case of degenerate dark matter, where a strong semi-annihilation line at 130 GeV would be accompanied by a weaker annihilation line at 173 GeV. As a proof of principle, we construct two explicit models of dark matter semi-annihilation, one based on non-Abelian vector dark matter and the other based on retrofitting Rayleigh dark matter.

79 ASTRONOMY AND ASTROPHYSICS↗

Coordinated Power and Energy Management Using Cluster of Microgrids to Improve Grid Availability and Resiliency

A coordinated power and energy management concept for a cluster of microgrids is presented in this paper. Distributed generation and storage resources at the low voltage end of the power distribution grid can be operated together as microgrids. These microgrids can operate in grid-connected mode and in islanded mode, thereby serving the loads within them during loss-of-service from the transmission network. In the proposed coordinated microgrid management scheme, multiple microgrids, operated as a cluster, can be connected using tie reclosers or through auxiliary distribution lines as a retrofit operation, which are activated during transmission system failure, and power generated or energy stored are shared between microgrids with different power demands. The operation can be achieved with no modified power inverter controls, and minimal changes to the supervisory / dispatch control and communications systems. In this paper, the cluster of microgrids presented include solar photovoltaic (PV) plants, battery energy storage systems (BESS) and loads. A demonstration cluster with two microgrids is operated using a real-time hardware-in-loop platform to show power and energy management during transmission system failure.

Essakiappan, Somasundaram↗

A Fast-Response High-Accuracy Overvoltage Protection Circuit for Soft-Switching Current-Source Converters

Although voltage-source converters (VSCs) have been a focus of research for decades and are widely applied in numerous applications, they face great challenges in short-circuit failures, high dv/dt and electromagnetic interference (EMI), especially using wide bandgap devices. Instead, current-source converters (CSCs) are attracting increasing attention in recent years owing to their friendliness to short-circuit faults, improved EMI, etc. For CSCs, overvoltage is the most catastrophic failure since the semiconductor devices can hardly withstand an overvoltage for a short pulse. In this paper, a fast-response high-accuracy overvoltage protection (OVP) circuit is proposed to protect CSCs from overvoltage damage. It also features a small form factor, good noise-immunity, friendly retrofit capability, and no need for active switches. In this paper, the operating principle and design guideline of the proposed OVP circuit is introduced. Its effectiveness is validated in soft-switching solid-state transformer (S4T) at 500 V. In experiments, the voltage detection error of less than 5% and a propagation delay of fewer than 400 ns have been achieved.

30 DIRECT ENERGY CONVERSION↗

Enabling Technology for Energy Sustainability: Power Electronic Converter Control for Renewables

To ensure high penetration of renewable energy sources into power grids, their interfacing inverters need to be designed to provide grid support functions. Important grid support functions include frequency and voltage support. To this end, the research community has recently invested heavily on grid-forming control pilot projects. Grid forming control aims to replace traditional grid following control, which is based on phase-locked loop and can achieve decoupled real and reactive power control. Here, in this article, we review the state-of-the-art grid following and forming technology and point out some deficiencies in dynamic performance in the widely adopted grid-forming control design. We also examine how to ensure that the vector control capable of decoupled real and reactive power regulation can also be achieved in the grid forming design. This type of design has been prototyped and shown great potential to enable retrofitting of large amounts of grid-following controllers through purely software algorithm update. The technology ensures reliable operation of power grids with high penetration of IBRs, thereby further reducing fossil fueled energy sources and cut down carbon emission.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Pumped Thermal Energy Storage Cycle with Capacity for Concentrated Solar Power Integration

Pumped thermal energy storage (PTES) is a grid-scale energy management technology that stores electricity in the form of thermal energy. A number of PTES systems have been proposed using different thermodynamic cycles, including a variant based on a regenerated Brayton cycle that stores the thermal energy in liquid storage media (such as molten salts) via heat exchangers. This has several advantages, including the possibility to consider hybrid 'solar-PTES' systems employing technology developed by the concentrated solar power (CSP) industry. Such a hybrid system could charge the same hot stores using either solar energy or off-peak electricity (e.g, from nearby wind farms), increasing the capacity factor of the plant while employing the same heat engine during discharge. In this paper, two different configurations of solar-PTES systems are proposed and studied numerically: (i) a configuration in which an existing CSP plant is retrofitted with a Brayton heat pump, and (ii) a configuration in which a new hybrid plant uses the Brayton cycle both for charge and discharge. In both cases, the need to absorb and reject heat at conditions close to ambient temperature requires the Brayton cycle to incorporate intercooled stages at the cold side of the cycle. On the other hand, the intercooling process increases the minimum temperature of the cold stores, meaning that widely available and nonflammable antifreeze solutions (such as water-ethylene glycol) may be used as the cold storage medium.

14 SOLAR ENERGY↗

A Self-Biasing Pulsed Depressed Collector

Depressed collectors have been utilized successfully for many years to improve the electrical efficiency of vacuum electron devices. Increasingly, pulsed, high-peak power accelerator applications are placing a premium on electrical efficiency. As RF systems are responsible for a large percentage of the overall energy usage at accelerator laboratories, methods to improve upon the state-of-the-art in pulsed high-power sources are desired. This paper presents a technique for self-biasing the stages in a multistage depressed collector. With this technique, the energy lost during the rise and fall times of the pulse can be recovered, separate power supplies are not needed, and existing modulators can be retrofitted. Calculations show that significant cost savings can be realized with the implementation of this device in high-power systems. In this paper, the technique is described along with experimental demonstration. (auth)

43 PARTICLE ACCELERATORS↗

Vehicular Integration of Wireless Power Transfer Systems and Hardware Interoperability Case Studies

Several wireless charging methods are under development or available as an aftermarket option in the light-duty automotive market. However, there are not a sufficient number of studies detailing the vehicle integration methods, particularly a complete vehicle integration with higher power levels. This paper presents the design, development, implementation, and vehicle integration of wireless power transfer (WPT)-based electric vehicle (EV) charging systems for various test vehicles. Before having the standards effective, it is expected that WPT technology first will be integrated as an aftermarket retrofitting approach. Inclusion of this technology on production vehicles is contingent upon the release of the international standards. The power stages of the system are introduced with the design specifications and control systems including the active front-end rectifier with power factor correction, high frequency power inverter, high frequency isolation transformer, coupling coils, vehicle side full-bridge rectifier and filter, and the vehicle battery. The operating principles of the control, and communications, systems are presented. Aftermarket conversion approaches including the WPT on-board charger (OBC) integration, WPT CHAdeMO integration, and WPT direct battery connection scenarios are described. Furthermore, the experiments are carried out using the integrated vehicles and the results obtained to demonstrate the system performance including the stage-by-stage efficiencies.

42 ENGINEERING↗

The Impacts of Distinct Flexibility Enhancements on the Value and Dynamics of Natural Gas Power Plant Operations

The rapid increase of renewable generation and its anticipated continued growth requires greater operational flexibility in modern power systems. Previous studies explored the addition of more flexible resources to improve system flexibility, but this may also be achieved at lower cost by enhancing existing power plants via flexibility retrofits. Potential flexibility upgrades to existing thermal plants include modifications that enable faster ramp rates, increase maximum load levels, decrease minimum load levels, and provide faster and lower cost startup operations. In this paper, we focus on improvements to existing natural gas combined cycle generators, and apply a unit commitment model to analyze the impact that each specific upgrade has on their operational dynamics and profitability from both the system perspective and from the asset owner perspective. We show that the value of each type of flexibility improvement varies depending on the capacity factor and usage pattern of the generator before the upgrade, and that the relative benefit of each type of flexibility varies. We demonstrate diminishing returns to increased flexibility when upgrading multiple generators simultaneously. Sensitivity tests for several shares of renewable generation, different generation mixes and different net load realizations confirm the generality of the results shown.

03 NATURAL GAS↗

Potential of Utilizing Thermal Energy Storage Integrated Ground Source Heat Pump System to Reshape Electricity Demand in the United States

Each year, more than 20% of electricity generated in the United States is consumed for meeting the thermal demands (e.g., space cooling, space heating, and water heating) in residential and commercial buildings. Integrating thermal energy storage (TES) with building’s HVAC systems has the potential to reshape the electric load profile of the building and mitigate the mismatch between the renewable generation and the demand of buildings. A novel ground source heat pump (GSHP) system integrated with underground thermal energy storage (UTES) has been proposed to level the electric demand of buildings while still satisfying their thermal demands. This study assessed the potential impacts of the proposed system with a bottom-up approach. The impacts on the electricity demand in various electricity markets were quantified. The results show that, within the capacity of the existing electric grids, the maximum penetration rate of the proposed system in different wholesale markets could range from 51% to 100%. Altogether, about 46 million single-family detached houses can be retrofitted into the proposed system without increasing the annual peak demand of the corresponding markets. By implementing the proposed system at its maximum penetration rate, the grid-level summer peak demand can be reduced by 9.1% to 18.2%. Meanwhile, at the grid level, the annual electricity consumption would change by –12% to 2%. The nationwide total electricity consumption would be reduced by 9%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

FOULING MITIGATION FOR LASER IGNITERS IN NATURAL GAS ENGINES

Due to several recent developments in lasers and optics, laser igniters can now be designed to be (i) compact so as to have the same footprint as a standard spark plug, (ii) have low power draw, usually less than 50 Watts, and (iii) have vibration and temperature resistance at levels typical of reciprocating engines. Primary advantages of these laser igniters remain (i) extension of lean or dilution limits for ignition of combustible mixtures, and (ii) improved ignition at higher pressures. Recently, tests performed in a 350 kW six-cylinder stationary natural gas reciprocating engine retrofitted with these igniters showed an extension of the operational envelope to yield efficiency improvements of the order of 2.6% points while being compliant with the mandated emission regulations. Even though laser igniters offer promise, fouling of the final optical element that introduces the laser into the combustion chamber is of concern. After performing a thorough literature search, a test plan was devised to evaluate various fouling mitigation strategies. The final approach that was used is a combination of three strategies and helped sustain an optical transmissivity exceeding 98% even after 1500 h of continuous engine operation at 2400 rpm. Based on the observed trend in transmissivity, it now appears that laser igniters can last up to 6000 h of continuous engine operation in a stationary engine running at 1800 rpm.

spark ignited engines, laser ignition, natural gas↗

Characterization of Flex-Fuel Prechamber Enabled Mixing-Controlled Combustion With Gasoline/Ethanol Blends at High Load

This numerical study focuses on the characterization of prechamber-enabled mixing-controlled combustion (PC-MCC) at ~18 bar brake mean effective pressure (BMEP) and 2200 rpm with 10% by volume ethanol-gasoline blend (E10) and pure ethanol (E100). Computational fluid dynamic (CFD) simulations of a stock and prechamber retrofitted single-cylinder Caterpillar C9.3B are carried out using CONVERGE. Prechamber equivalence ratio at spark timing, prechamber spark timing advance, and main chamber injection strategy are assessed with respect to their impact on ignition assistance performance and emissions characteristics relative to a diesel baseline at the same boundary conditions. Simulation results indicate that PC-MCC is flex-fuel capable and operates well for both E10 and E100 at the operating conditions considered. The results demonstrate that the use of a pilot-main injection strategy enables spark timing in the prechamber to be advanced and thus reduces spark plug firing pressure while maintaining robust ignition assistance. Results also indicate that the rich prechamber operation is favored for improved ignition assistance capabilities. Furthermore, the findings of this work suggest that a heavy-duty vehicle using a PC-MCC engine can utilize any blend of gasoline and ethanol, up to including pure ethanol, with no major sacrifices in performance relative to the diesel engine.

33 ADVANCED PROPULSION SYSTEMS↗

Cooled Spray Technology for Particulate Reduction in a Heavy-Duty Engine

Cooled spray (CS) technology passively reduces particulate matter (PM) emissions from diesel engines compared to non-CS-equipped diesel engines. CS inserts are mounted near the injector nozzle and control mixing so that the fuel and air can premix while limiting combustion near fuel-rich zones, thereby reducing the formation of particulate matter. CS components contain no moving parts and could be installed as a retrofit or built into new engines. However, CS technology is early in its development, and further investigations are needed to understand the overall performance implications and practicality of the technology. In this paper, we investigate several important aspects of CS, providing a clearer picture of some challenges and potential benefits of CS. Two alignment techniques are used to characterize measurement ease and bias, namely, an optical alignment and spray-plug impact alignment. While the optical technique facilitates alignment more easily, a bias was measured between the optical and spray-plug techniques, suggesting the optical technique may have insufficient accuracy without additional corrections. We also evaluate the engine performance of a well-aligned and poorly aligned CS insert, compared to the baseline configuration. The poorly aligned insert shows slower combustion than the baseline and mixed overall performance. However, the well-aligned insert shows faster combustion than the baseline and PM emission reduction at most operating conditions, with some conditions showing PM reduction up to 80%. Furthermore, the results of this paper highlight the alignment challenges of CS technology as well as the potential PM reduction benefit of the technology.

33 ADVANCED PROPULSION SYSTEMS↗

Prediction of Thermal Conditions of DED With FEA Metal Additive Simulation

This paper presents the integration of wire-arc additive manufacturing (WAAM) using Gas Metal Arc Welding (GMAW) into a machine tool to create a retrofit hybrid computer numeric control (CNC) machine tool. GMAW, along with other direct energy deposition systems, has the capacity to deposit material faster than the excess thermal energy can dissipate. This results in the need to allow the part to cool between consecutive layers, which is the most time-consuming part of the additive process. Finite element analysis (FEA) was used in conjunction with monitored build plate surface temperatures during deposition samples to improve adequate dwell time prediction and to develop a cooling system. A deposition was completed where no dwell time was used and the build plate along with the machine table temperatures were monitored. A second deposition was completed where only one bead was deposited and the traverse speed was increased. The GMAW welder was mounted on a 3-axis CNC machine where two square deposition samples were completed. A FEA model was designed and verified using the monitored samples. The model will be used to determine improved depositions speeds and whether forced cooling would allow for an increased deposition rate without structural failure. It was determined the FEA software can be used to accurately model and predict the thermal response of WAAM AM components.

Heinrich, Lauren↗