Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reference Values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Size Dependence of the Melting Point of Silicon Nanoparticles: Molecular Dynamics and Thermodynamic Simulation

The size dependence of the melting point of Si nanoparticles is investigated using molecular dynamics and thermodynamic simulation based on the Thomson’s formula. The atomistic modeling data obtained using the Stillinger–Weber potential agree with the results reported by other authors and thermodynamic-simulation data and predict a decrease in the melting point T{sub m} of Si nanoparticles with an increase in their reciprocal radius R{sup –1} according to linear law. The available experimental data predict lower T{sub m} values, including the limiting value T{sub m}{sup (∞)}, which corresponds to the linear extrapolation of experimental points to R{sup –1} → 0 (to the radius R → ∞); the underestimation is 200–300 K as compared with the reference melting point of silicon (1688 K). It is concluded that the molecular-dynamics data on T{sub m}(R{sup –1}) obtained using the Stillinger–Weber potential are more adequate than the available experimental data.

74 ATOMIC AND MOLECULAR PHYSICS↗

SU-G-TeP3-02: Determination of Geometry-Specific Backscatter Factors for Radiobiology Studies

Purpose: Radiation biology research relies on an accurate radiation dose delivered to the biological target. Large field irradiations in a cabinet irradiator may use the AAPM TG-61 protocol. This relies on an air-kerma measurement and conversion to absorbed dose to water (Dw) on the surface of a water phantom using provided backscatter factors. Cell or small animal studies differ significantly from this reference geometry. This study aims to determine the impact of the lack of full scatter conditions in four representative geometries that may be used in radiobiology studies. Methods: MCNP6 was used to model the Dw on the surface of a full scatter phantom in a validated orthovoltage x-ray reference beam. Dw in a cylindrical mouse, 100 mm Petri dish, 6-well and 96-well cell culture dishes was simulated and compared to this full scatter geometry. A reference dose rate was measured using the TG-61 protocol in a cabinet irradiator. This nominal dose rate was used to irradiate TLDs in each phantom to a given dose. Doses were obtained based on TLDs calibrated in a NIST-traceable beam. Results: Compared to the full scattering conditions, the simulated dose to water in the representative geometries were found to be underestimated by 12-26%. The discrepancy was smallest with the cylindrical mouse geometry, which most closely approximates adequate lateral- and backscatter. TLDs irradiated in the mouse and petri dish phantoms using the TG-61 determined dose rate showed similarly lower values of Dw. When corrected for this discrepancy, they agreed with the predicted Dw within 5%. Conclusion: Using the TG-61 in-air protocol and given backscatter factors to determine a reference dose rate in a biological irradiator may not be appropriate given the difference in scattering conditions between irradiation and calibration. Without accounting for this, the dose rate is overestimated and is dependent on irradiation geometry.

60 APPLIED LIFE SCIENCES↗

Measured Thermal and Fast Neutron Fluence Rates ATR Cycles 171A ATF (Rev. 1)

This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for ATR Cycle 171A ATF which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order. This report contains fluence rate values corresponding to the particular elevations (relative to the 80-ft. core elevation) where the measurements were taken. The data in this report consists of (1) a table of the ATR power history and distribution, (2) a listing of the calculated thermal and fast neutron fluence rates, and (3) plots of calculated both the thermal and fast neutron fluence rates. The fluence rates reported are for the average power levels given in the table of power history and distribution. During the irradiation of Cycle 152A, the RML performed additional flux measurements to assess core reconfiguration issues. Measurements using cadmium covered as well as bare neutron monitors in the Southwest, Southeast, and H positions of the Center lobe were performed to determine the division in neutron energy between epithermal and thermal neutrons. This is defined as the resonance correction defined in this report. It is used to quantify both thermal and fast neutron flux. For more information please refer to letter, “RADIATION MEASUREMENTS LABORATORY MEASUREMENTS OF IN CORE ATR PHYSICS TESTING DURING CYCLE 152A” dated January 24, 2013, to Casey Stengel from C. C. Jensen. The measured values documented in RML Procedure, “ACMM-3600, Flux Monitoring,” will be used indefinitely until further measurements supersede the current values.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measured Thermal and Fast Neutron Fluence Rates ATR Cycles 171A IR TMIST 3B

This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for ATR Cycle 171A which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order. This report contains fluence rate values corresponding to the particular elevations (relative to the 80-ft. core elevation) where the measurements were taken. The data in this report consists of (1) a table of the ATR power history and distribution, (2) a listing of the calculated thermal and fast neutron fluence rates, and (3) plots of calculated both the thermal and fast neutron fluence rates. The fluence rates reported are for the average power levels given in the table of power history and distribution. During the irradiation of Cycle 152A, the RML performed additional flux measurements to assess core reconfiguration issues. Measurements using cadmium covered as well as bare neutron monitors in the Southwest, Southeast, and H positions of the Center lobe were performed to determine the division in neutron energy between epithermal and thermal neutrons. This is defined as the resonance correction defined in this report. It is used to quantify both thermal and fast neutron flux. For more information please refer to letter, “RADIATION MEASUREMENTS LABORATORY MEASUREMENTS OF IN CORE ATR PHYSICS TESTING DURING CYCLE 152A” dated January 24, 2013, to Casey Stengel from C. C. Jensen. The measured values documented in RML Procedure, “ACMM-3600, Flux Monitoring,” will be used indefinitely until further measurements supersede the current values.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Number-operator-annihilation-operator uncertainty as an alternative for the number-phase uncertainty relation

We consider a number-operator-annihilation-operator uncertainty as a well-behaved alternative to the number-phase uncertainty relation, and examine its properties. We find a formulation in which the bound on the product of uncertainties depends on the expectation value of the particle number. Thus, while the bound is not a constant, it is a quantity that can easily be controlled in many systems. The uncertainty relation is approximately saturated by number-phase intelligent states. This allows us to define amplitude squeezing, connecting coherent states to Fock states, without a reference to a phase operator. We propose several setups for an experimental verification.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Kinetic Alfvén Turbulence: Electron and Ion Heating by Particle-in-cell Simulations

Three-dimensional particle-in-cell simulations of the forward cascade of decaying kinetic Alfvén turbulence have been carried out as an initial-value problem on a collisionless, homogeneous, magnetized, electron–ion plasma model with β{sub e}=β{sub i}=0.50 and m {sub i}/m {sub e} = 100, where subscripts e and i represent electrons and ions, respectively. Initial anisotropic narrowband spectra of relatively long-wavelength modes with approximately gyrotropic distributions in k{sub ⊥} undergo a forward cascade to broadband spectra of magnetic fluctuations at shorter wavelengths. Maximum electron and ion heating rates are computed as functions of the initial fluctuating magnetic field energy density ε{sub o} on the range 0.05<ε{sub o}<0.50. In contrast to dissipation by whistler turbulence, the maximum ion heating rate due to kinetic Alfvén turbulence is substantially greater than the maximum electron heating rate. Furthermore, ion heating as well as electron heating due to kinetic Alfvén turbulence scale approximately with ε {sub o}. Finally, electron heating leads to anisotropies of the type T{sub ∥e}>T{sub ⊥e}, where the parallel and perpendicular symbols refer to directions parallel and perpendicular, respectively, to the background magnetic field, whereas the heated ions remain relatively isotropic. This implies that, for the range of ε {sub o} values considered, the Landau wave–particle resonance is a likely heating mechanism for the electrons and may also contribute to ion heating.

79 ASTRONOMY AND ASTROPHYSICS↗

Accurate electronic and chemical properties of 3d transition metal oxides using a calculated linear response U and a DFT + U(V) method

We validate the usage of the calculated, linear response Hubbard U for evaluating accurate electronic and chemical properties of bulk 3d transition metal oxides. We find calculated values of U lead to improved band gaps. For the evaluation of accurate reaction energies, we first identify and eliminate contributions to the reaction energies of bulk systems due only to changes in U and construct a thermodynamic cycle that references the total energies of unique U systems to a common point using a DFT + U(V ) method, which we recast from a recently introduced DFT + U(R) method for molecular systems. We then introduce a semi-empirical method based on weighted DFT/DFT + U cohesive energies to calculate bulk oxidation energies of transition metal oxides using density functional theory and linear response calculated U values. We validate this method by calculating 14 reactions energies involving V, Cr, Mn, Fe, and Co oxides. We find up to an 85% reduction of the mean average error (MAE) compared to energies calculated with the Perdew-Burke-Ernzerhof functional. When our method is compared with DFT + U with empirically derived U values and the HSE06 hybrid functional, we find up to 65% and 39% reductions in the MAE, respectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Doppler Lidar Motion-Correction (DLMC) Value-Added Product Report

The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) second ARM Mobile Facility (AMF2) Doppler lidar (S/N 0319-160) was deployed on the German ice breaker Polarstern during the Multidisciplinary Drifting Observatory for the Study of Arctic Climate (MOSAiC) campaign during 2019-2020 (see Figure 1). This was the first deployment of the new AMF2 Doppler lidar, as well as the first ship-based deployment of a Doppler lidar (DL) by ARM. In contrast to land-based deployments, the lidar’s heading (a.k.a. home point) and tilt are constantly changing, and lidar’s radial velocity measurements are impacted by the ship’s motion. Since the beam directions are reported relative to the instrument’s frame of reference, derivation of higher-order data products such as wind speed and direction require that the lidar’s attitude and translational velocity be properly accounted for. The Doppler Lidar Motion-Correction (DLMC) Value-Added-Product (VAP) was developed specifically for ship-based deployments of the Doppler lidar. This VAP combines raw uncorrected data from the DL and simultaneous measurements from the ARM Navigation system (NAV) (Walton 2019) to transform the beam angles from the lidar coordinate system to an Earth-fixed coordinate system. The VAP also removes the contribution of the lidar’s platform velocity from the radial velocity measurements. This report documents the methods used by the DLMC to perform these corrections.

54 ENVIRONMENTAL SCIENCES↗

Visibility of Hypovascularized Liver Tumors during Intra-Arterial Therapy Using Split-Bolus Single-Phase Cone Beam CT

Purpose: To validate a split-bolus contrast injection protocol for single-phase CBCT in terms of detectability of hypovascular liver tumors compared to digital subtraction angiography (DSA). Materials and Methods: In this retrospective, single-center study, 20 consecutive patients with in total 77 hypovascularized tumors referred for intra-arterial therapy received a split-bolus single-phase CBCT. Two readers rated the visibility of the target tumors scheduled for embolization in CBCT and DSA compared to the pre-interventional multiphasic CT or MRI used as reference on a 3-point scoring system (1 = optimal, 3 = not visible) and catheter-associated artifacts (1 = none, 3 = extended). SNR, CNR and contrast values were derived from 37 target tumors in CBCT and MRI. Statistical analysis included the kappa test to determine interrater reliability, the Friedman’s test for the inter-modality comparison evaluating tumor visibility in DSA and CBCT as well as for quantitative assessment. Post hoc analysis included the Wilcoxon signed-rank test. p values < 0.05 were considered significant. Results: Ninety percentage of target tumors were rated as visible in CBCT and 37.5% in DSA (p < 0.001). 70.1% of pre-interventionally detected hypovascularized tumors were depicted with CBCT and 31.2% by DSA (p < 0.001). 7.8% of known tumors were outside the FOV. Quantitative assessment showed higher image contrasts in CBCT (1.91 ± 7.01) compared to hepatobiliary-phase MRI (0.29 ± 0.14, p = 0.003) and to portal-venous (p.v.) MRI (0.31 ± 0.13, p < 0.001), but higher CNR for MRI (1.18 ± 0.80; 13.92 ± 15.82; 13.79 ± 6.65). Conclusion: In conclusion, the split-bolus single-phase CBCT detects significantly more hypovascularized liver tumors compared to DSA performed through the proper hepatic artery with high image contrasts. Level of Evidence: Level III, diagnostic study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of LiAlO{sub 2} nanoparticle filler concentration on the electrical properties of PEO–LiClO{sub 4} composite

Highlights: ► Structural modification of nano LiAlO{sub 2} filler increased conductivity. ► Good ionic conductivity for (LiAlO{sub 2}){sub 1.5}(PEO){sub 11}(LiClO{sub 4}) at room temperature. ► Nano LiAlO{sub 2} filler enhanced both ion migration and orientation. ► High dielectric properties for (LiAlO{sub 2}){sub 1.5}(PEO){sub 11}(LiClO{sub 4}) at room temperature. - Abstract: Nano-composite polymer electrolytes are receiving attention as potential candidates to be used as electrolyte membranes in lithium polymer batteries and other devices. In this work, polyethylene oxide–LiClO{sub 4} based composite polymer electrolyte was prepared by solution casting method. The effect of LiAlO{sub 2} nanoparticle ceramic filler concentration on the structure and electrical conduction of the composite was studied. Nano-LiAlO{sub 2} was synthesized by sol–gel method. The samples were characterized using X-ray diffraction, Fourier Transmission-Infra Red, Differential Scanning Calorimetry, and tested by dielectric properties, Direct and Alternating current measurements as well as by impedance spectroscopy. All samples showed a behavior referring to an ionic conduction. Generally, the melting temperature of the polymer electrolyte decreased with filler concentration. Both thermal property and filler concentration influenced conductivity value. At room temperature, the highest ionic conductivity was 9.76 × 10{sup −5} ohm{sup −1} cm{sup −1} for sample with a composition of (LiAlO{sub 2}){sub 1.5}(polyethylene oxide){sub 11}(LiClO{sub 4}). All results were correlated and discussed.

36 MATERIALS SCIENCE↗

Symmetry Breaking in Side Chains Leading to Mixed Orientations and Improved Charge Transport in Isoindigo- alt -Bithiophene Based Polymer Thin Films

The selection of side chains is important in design of conjugated polymers. It not only affects their intrinsic physical properties, but also has an impact on thin film morphologies. Recent reports suggested that a face-on/edge-on bimodal orientation observed in polymer thin films may be responsible for a three-dimensional (3D) charge transport and leads to dramatically improved mobility in donor–acceptor based conjugated polymers. To achieve a bimodal orientation in thin films has been seldom explored from the aspect of molecular design. In this work, we demonstrate a design strategy involving the use of asymmetric side chains that enables an isoindigo-based polymer to adopt a distinct bimodal orientation, confirmed by the grazing incidence X-ray diffraction. As a result, the polymer presents an average high mobility of 3.8 ± 0.7 cm 2 V –1 s –1 with a maximum value of 5.1 cm 2 V –1 s –1 , in comparison with 0.47 and 0.51 cm 2 V –1 s –1 obtained from the two reference polymers. This study exemplifies a new strategy to develop the next generation polymers through understanding the property-structure relationship.

three-dimensional charge transport↗

Design optimization of gap distance for the capillary limitation of a heat pipe with annular-type wick structure

In this study, an experimental investigation was conducted on the rising height and contact angle of fluid in an annular wick-type heat pipe. The annular wick-type heat pipe was characterized by a small gap between the wick structure and tube wall, which compensated for the pressure drop along the porous media and created additional capillary force. To describe and model the advantage of this gap, the rising of a wetting liquid in the gap between a vertical solid plate and a mesh (with a small angle between them) was experimentally measured and analyzed. An additional experiment was performed to investigate the effect of curvature on the capillary rise using tubes and meshes of varying radii. Resultantly, we confirmed that the linear combination of the contact angles of the solid plate and mesh could be applied to calculate the rising height from the Laplace–Young equation. Furthermore, the effect of curvature on the rising height of the liquid was negligible. These results were extended to the investigation of finding the optimal gap distance for the annular wick-type heat pipe by referring to previous studies. We observed that a gap distance of 1.27 mm provided the largest permeability (K) over the effective pore radius (r eff ) value for a heat pipe with ethanol, which in turn resulted in the highest capillary limitation. For a sodium heat pipe, a gap distance of 0.84 mm resulted in the highest capillary limitation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Rapid Prediction of Low (<1%) trans Fat Content in Edible Oils and Fast Food Lipid Extracts by Infrared Spectroscopy and Partial Least Squares Regression

Abstract The United States Food and Drug Administration (FDA) ruled that partially hydrogenated oils (PHO), the major dietary source of industrially produced trans fat (TF), were no longer “generally recognized as safe (GRAS)” for any use in human food. Consequently, the objective of this study was to develop a rapid screening procedure using attenuated total reflection Fourier‐transform infrared (ATR‐FTIR) spectroscopy in conjunction with partial least squares regression (PLSR) for the quantitative and accurate prediction of low concentrations of trans fatty acid (TFAs) (<1% of total fatty acids (FAs)). Broad‐based calibration models were developed for a combined set of samples consisting of edible oils and fast food lipid extracts. Predicted concentrations of TFAs in the two matrices showed good correlation with the primary reference data generated by gas chromatography (GC) ( R 2 > 0.99) and high accuracy as evidenced by low root‐mean‐square error of cross‐validation (RMSECV) values. The lowest TFA concentration, determined by GC to be 0.13% of total FAs, was accurately predicted by ATR‐FTIR/PLSR as 0.18% of total FAs. This simple, rapid ATR‐FTIR/PLSR methodology has the potential for use as a screening alternative to conventional gas chromatographic methods for predicting the TFA content of edible oils and food lipid extracts for regulatory purposes and quality control of raw material and processed food. Practical Applications F DA ruled that partially hydrogenated oils were no longer “generally recognized as safe (GRAS)” for any use in human food. Consequently, we have proposed a rapid screening procedure, based on infrared spectroscopy and chemometrics, to rapidly and accurately predict low concentrations of trans fatty acids (<1% of total fatty acids) in edible oils and food lipid extracts.

Karunathilaka, Sanjeewa R.↗

Benchmark Measurements of the BeRP Ball in Various Reflectors

Details of benchmark neutron multiplicity measurements of the 4.484 kg Beryllium Reflected Plutonium (BeRP) ball inside of various reflectors. Measurements were performed with an Ortec Fission Meter neutron multiplicity counter. Measurements were made of the bare BeRP Ball, the BeRP Ball inside 3 inch thick polyethylene, nickel, and tungsten, and the polyethylene with an additional 2 inch thick steel reflector. For every measurement, the mass m S of 240 Pu, k eff , multiplication M, and escape multiplication ME are reported. For each individual measurement, the measured mass mS of 240 Pu in the BeRP Ball was within 20.7 grams (closest edge of measurement errorbar to closest edge of errorbar for reference mS from isotopics). The combined measurement of the mass of 240 Pu m S = 267 ± 7 grams which compared very favorably to the known value from isotopics of m S = 266.8 ± 0.5 grams.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Beam Coupling Impedances of Inter-cell Section in Scorpius Linac

The following technical note is prepared for distribution to external project collaborators. An inter-cell pumping section in the Scorpius linac contains a pumping grid with slots, bellows, and vacuum plenum. The beam coupling impedances of the inter-cell section are calculated with CST Studio. Important to note that all impedance values in the tech note below should be divided by a factor of 2 to obtain the beam coupling impedances in their standard definition; see reference for details.

43 PARTICLE ACCELERATORS↗

Energy-based break-even transportation distance of biomass feedstocks

The distance a solid biomass feedstock could be used to transport the feedstock when used as biobased fuel is critical information for transportation analysis. However, this information is not available. The break-even transportation distance (BTD) of various fuels from biomass feedstocks and fossil sources was analyzed for truck, rail, and ship transport modes based on bulk density, moisture content, and specific energy. Fourteen different biomass feedstocks, such as crop residues (e.g., corn stover), woody biomass (e.g., wood chips), including thermally pretreated (torrefied) and densified forms (pellets), cattle feedlot compost, and three standard fossil fuels, namely, coal, lignite, and diesel, were considered for BTD analysis and comparison. The BTD values were derived by comparing the energy content of biomass feedstocks with the energy expended in transporting the fuels through selected transportation modes. For ready reference, an alternative derivation of BTD equations and example calculations were also presented. Among the biomass feedstocks, torrefied pellets had the highest BTD (4.16 × 10 4 , 12.47 × 10 4 , and 54.14 × 10 4 km), and cattle feedlot compost had the lowest BTD (1.29 × 10 4 , 3.88 × 10 4 , and 9.23 × 10 4 km), respectively, for truck, rail, and ship. Higher bulk density and higher specific energy of the biomass feedstocks increased the BTD for all modes of transport. Transport is most efficient when mass-limited. Biomass feedstock bulk densities where transportation becomes mass-limited are 223, 1,480, and 656 kg/m 3 for truck, rail, and ship, respectively. Truck transport is typically mass-limited (payload limit restriction; increased BTD), whereas rail transport is entirely volume-limited (cargo space restriction; decreased BTD), and ship transport is mostly volume-limited for biomass feedstocks and mass-limited for densified biomass feedstocks. Ship transport is the most efficient, followed by rail and truck; on average for the materials (17) studied, rail is 3.1 times and ship is 9.2 times the truck's BTD. Based on the bulk density and higher specific energy of the biomass feedstocks, regardless of the refinery location, interstate truck transport of these feedstocks is not a limiting factor in the bio-refining process., with the studied biomass feedstock BTD per truckload representing between 0.89 and 2.88 times the US perimeter.

09 BIOMASS FUELS↗

Determining the slag fraction, water/binder ratio and degree of hydration in hardened cement pastes

A method for determining the original mix composition of hardened slag-blended cement-based materials based on analysis of backscattered electron images combined with loss on ignition measurements is presented. The method does not require comparison to reference standards or prior knowledge of the composition of the binders used. Therefore, it is well-suited for application to real structures. The method is also able to calculate the degrees of reaction of slag and cement. Results obtained from an experimental study involving sixty samples with a wide range of water/binder (w/b) ratios (0.30 to 0.50), slag/binder ratios (0 to 0.6) and curing ages (3 days to 1 year) show that the method is very promising. The mean absolute errors for the estimated slag, water and cement contents (kg/m{sup 3}), w/b and s/b ratios were 9.1%, 1.5%, 2.5%, 4.7% and 8.7%, respectively. 91% of the estimated w/b ratios were within 0.036 of the actual values. -- Highlights: •A new method for estimating w/b ratio and slag content in cement pastes is proposed. •The method is also able to calculate the degrees of reaction of slag and cement. •Reference standards or prior knowledge of the binder composition are not required. •The method was tested on samples with varying w/b ratios and slag content.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Multi-plane moment-of-fluid interface reconstruction in 3D

Moment-of-fluid (MOF) methods for interface reconstruction approximate the region occupied by material in each mesh element only through reference to its geometric moments. Here, we present a 3D MOF method that represents the material (POM) in each cell as the convex intersection of the cell and multiple half-spaces, each selected to minimize the least-squares error between computed moments of the approximated material and provided reference moments. This optimization problem is highly non-linear and non-convex, making the numerical result very sensitive to the initial guess. To create an effective initial guess in each cell, we construct an ellipsoid from 0th–2nd order reference moments such that its shape corresponds with that of the POM. Within this ellipsoid we inscribe a polyhedron, and initialize the minimization problem with the half-spaces defined by each of its faces. The inscribed polyhedron has minimally 4 faces, and using up to 3rd order moments permits optimization over up to 20 unknown values. We therefore define MOF methods that utilize 4, 5, or 6 half-spaces, correspondingly initialized with the faces of a single inscribed tetrahedron, triangular prism, or hexahedron. Stability of the non-linear optimization is further improved with a prepossessing step that normalizes the reference moments according to the axes of the reference ellipsoid. Using this approach, the non-linear least-squares solver reliably converges to a near-global minimum from a single initial guess. We demonstrate accuracy and robustness using single-cell and multi-cell examples over a wide spectrum of geometry. In particular, we demonstrate our ability to exactly reproduce several important and complex features defined by up to four half-spaces, such as corners, filaments, filament tips, and embedded material in the cell.

3D interface reconstruction↗