Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ROBOTICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Material Testing for Robotic Omnidirectional Anchor

To successfully explore near-Earth Asteroids the question of mobility emerges as the key issue for any robotic mission. When small bodies have extremely low escape velocities, traditional methods, such as wheels, would send the robot hurtling off of the asteroid's surface. To solve this problem, JPL has developed an omni-directional anchoring mechanism for use in microgravity that utilizes microspine technology. These microspines are placed in circular arrays with 16 independent carriages biasing the surface of the rock. The asperities in the surface allow the gripper to hold nearly 150N in all directions. While the gripper has been proven successful on consolidated rocks, it had yet to be tested on a variety of other surfaces that are suspected to separate the large boulders on an asteroid. Since asteroid surfaces vary widely, from friable rocks to lose ponds of regolith, the gripper was tested in a large variety of materials such as, bonded pumice, sand, gravel, and loose rocks. The forces are applied tangent, at 45 degrees, and normal to the surface of the material. The immediate results from this experiment will give insight into the gripper's effectiveness across the wide spectrum of materials found on asteroids.

Near-Earth Asteroids (NEOs)↗

Valkyrie Robot Capability Demonstration: Thermal Camera and Body Stored Hand-Tool Usage

A video that provides an automated tool grasp industrial scenario for the NASA Valkyrie Robot from the NASA Dexterous Robotics Team. The scenario is where the Valkyrie uses externally mounted sensors and tools to investigate a room for objects of interest and removes any hazards. Video running time is 4 min., 56 sec.; in color with no sound.

Valkyrie↗

Valkyrie Robot Capability Demonstration: Autonomous Grab of Body Stored Hand-Tool

A video that provides an automated tool grasp industrial scenario for the NASA Valkyrie Robot from the NASA Dexterous Robotics Team. The scenario is where the Valkyrie uses externally mounted sensors and tools to investigate a room for objects of interest and removes any hazards. This video highlights the tool pick component of the full demonstration. Video run time is 3 min. 28 sec, in color with no sound.

Valkyrie↗

Robot Rodeo 2013

Sandia National Laboratories hosted the seventh annual Western National Robot Rodeo and Capability Exercise in June 2013. The five-day event is a lively and challenging competition that draws civilian and military bomb squad teams from across the country to see who can most effectively defuse dangerous situations with the help of robots.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Controls and process planning strategies for 5-axis laser directed energy deposition of Ti-6Al-4V using an 8-axis industrial robot and rotary motion

Interest in multi-axis additive manufacturing has grown significantly in recent years due to associated benefits that range from improved quality to support for greater geometric complexity. A method of 5-axis Laser Hot-Wire Directed Energy Deposition is developed and demonstrated in this study using an 8-axis industrial robot, comprised of a 6-axis serial link robot and a 2 degree-of-freedom positioner. Coordinated 5-axis motion is used to print Ti-6Al-4V objects predominantly through build plate rotation. Methods of slicing and toolpath generation are presented, including the use of an alternating toolpath direction philosophy and the manipulation of the CAD model surface normal vectors for determining the required build plate tilt angles for maintaining consistent deposition orientations relative to gravity. Another objective of the study was to determine the limits of conventional slicing and layer height control techniques for printing geometries with significant unsupported overhangs. A comparison is made between the behavior of normal and conformal bead alignment in this regard, and the performance of the layer height controller is reported as it relates to process stability and the limits of printing overhang geometries. Unsupported overhangs were successfully printed at 35° without build plate tilt and 45° with build plate tilt. Toolpath velocity and net-shape printing performance are reported as well, with 3D scans of the printed surfaces used for net-shape characterization. In all, the printing of three geometries is presented, including the overhang geometry, a 5-axis toolpath geometry, and a large-scale, multi-bead demonstrator part, which exceeded 500 mm in height and weighed 44 kg (97 lbs).

36 MATERIALS SCIENCE↗

The Curie–Da Vinci Connection: 5-Years' Experience With Laparoscopic (Robot-Assisted) Implantation for High-Dose-Rate Brachytherapy of Solitary T2 Bladder Tumors

Purpose: To report experience and early results of laparoscopic implantation for interstitial brachytherapy (BT) of solitary bladder tumors and the feasibility of a high-dose-rate (HDR) schedule. Methods and Materials: From December 2009 to April 2015, 57 patients with a T2 solitary bladder tumor were treated in Arnhem with transurethral bladder resection followed by external beam irradiation, applied to the bladder and regional iliac lymph nodes, 40 Gy in 20 fractions, 5 fractions per week, and within 1 week interstitial HDR BT, in selected cases combined with partial cystectomy and lymph node dissection. The BT catheters were placed via a transabdominal approach with robotic assistance from a Da Vinci robot after a successful initial experience with a nonrobotic laparoscopic approach. The fraction schedule for HDR was 10 fractions of 2.5 Gy, 3 fractions per day. This was calculated to be equivalent to a reference low-dose-rate schedule of 30 Gy in 60 hours. Data for oncologic outcomes and toxicity (Common Toxicity Criteria version 4) were prospectively collected. Results: These modifications resulted in an average postoperative hospitalization of 6 days, minimal blood loss, and no wound healing problems. Two patients had severe acute toxicity: 1 pulmonary embolism grade 4 and 1 cardiac death. Late toxicity was mild (n=2 urogenital grade 3 toxicity). The median follow-up was 2 years. Using cumulative incidence competing risk analysis, the 2-year overall, disease-free, and disease-specific survival and local control rates were 59%, 71%, 87%, and 82%, respectively. Conclusions: The benefits of minimally invasive surgery for implantation of BT catheters and the feasibility of HDR BT in bladder cancer are documented. The patient outcome and adverse events are comparable to the best results published for a bladder-sparing approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Experimental demonstration and modeling of a robotic neutron detector with spectral and directional sensitivity for treaty verification

International safeguards and arms control agreements often require labor-intensive, intrusive onsite inspections to perform verification tasks. The ability to localize a neutron source and/or characterize a neutron field may be imperative for identifying anomalies. We are interested in the role of autonomous mobile robots, which, if designed properly, may be more effective and efficient and less intrusive than their human counterparts. Toward developing such a capability, we, for this study, have constructed the N-SpecDir Bot, comprised of three boron-coated straw detectors azimuthally-distributed within a cylinder of high-density polyethylene, which is mounted on an omni-directional robotic platform. Our N-SpecDir Bot is specifically designed to provide spectral and directional sensitivity, in addition to gross counts, by utilizing the signals from the three detectors. The detection system has been extensively characterized by MCNP modeling, which has been benchmarked to experiments conducted at the Princeton Plasma Physics Laboratory. We demonstrate the spectral and directional sensitivity experimentally and in simulation, and provide a simple yet robust method for directional measurements.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Ultrasonic detection technology based on joint robot on composite component with complex surface

Some components have complex surface, such as the airplane wing and the shell of a pressure vessel etc. The quality of these components determines the reliability and safety of related equipment. Ultrasonic nondestructive detection is one of the main methods used for testing material defects at present. In order to improve the testing precision, the acoustic axis of the ultrasonic transducer should be consistent with the normal direction of the measured points. When we use joint robots, automatic ultrasonic scan along the component surface normal direction can be realized by motion trajectory planning and coordinate transformation etc. In order to express the defects accurately and truly, the robot position and the signal of the ultrasonic transducer should be synchronized.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Combining gait optimization with passive system to increase the energy efficiency of a humanoid robot walking movement

There are several approaches to create the Humanoid robot gait planning. This problem presents a large number of unknown parameters that should be found to make the humanoid robot to walk. Optimization in simulation models can be used to find the gait based on several criteria such as energy minimization, acceleration, step length among the others. The energy consumption can also be reduced with elastic elements coupled to each joint. The presented paper addresses an optimization method, the Stretched Simulated Annealing, that runs in an accurate and stable simulation model to find the optimal gait combined with elastic elements. Final results demonstrate that optimization is a valid gait planning technique.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Developing stereo image based robot control system

Application of image processing is developed in various field and purposes. In the last decade, image based system increase rapidly with the increasing of hardware and microprocessor performance. Many fields of science and technology were used this methods especially in medicine and instrumentation. New technique on stereovision to give a 3-dimension image or movie is very interesting, but not many applications in control system. Stereo image has pixel disparity information that is not existed in single image. In this research, we proposed a new method in wheel robot control system using stereovision. The result shows robot automatically moves based on stereovision captures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Robotic automation of droplet microfluidics

Droplet microfluidics enables powerful analytic capabilities but often requires workflows involving macro- and microfluidic processing steps that are cumbersome to perform manually. Here, we demonstrate the automation of droplet microfluidics with commercial fluid-handling robotics. The workflows incorporate common microfluidic devices including droplet generators, mergers, and sorters and utilize the robot's native capabilities for thermal control, incubation, and plate scanning. The ability to automate microfluidic devices using commercial fluid handling will speed up the integration of these methods into biological workflows.

59 BASIC BIOLOGICAL SCIENCES↗

Design of a robot-automated flat plate/reflection geometry x-ray diffraction setup for accelerated materials discovery and structural screening

Here, we report the design, construction, and automation of a flat plate sample loading, alignment, and data acquisition system for X-ray diffraction measurements in reflection geometry implemented at the Stanford Synchrotron Radiation Lightsource. The system is built onto a single platform, enabling facile transferability, and is compartmentalized into sample storage, sample transfer, and sample position/alignment segments. The core feature of this system is a six-axis robotic arm that offers a large range of highly reproducible and programable movements. The degrees of freedom of the robot arm enable adaptability in which movements can be modified to fit various beamline environments and sample configurations. Samples are housed on 3D printed sample mounts, which are arranged onto a 6 × 2 array of sample cassettes capable of holding 7 samples. Using sample mounts designed for solid oxide electrolysis button cells (SOECs), the maximum tray capacity is 84 samples, which can be aligned and run in ~ 24 hours with long exposure scans. The sample array is additionally capable of accommodating a range of sample sizes and geometries due to the rapid 3D printed fabrication. The components of the setup will be described in detail and performance will be demonstrated with a set of representative SOEC and XRD standard samples. Opportunities for future developments and integration with the automated setup are summarized.

08 HYDROGEN↗

Sculpting crystals one Burgers vector at a time: Toward colloidal lattice robot swarms

Plastic deformation of crystalline materials with isotropic particle attractions proceeds by the creation and migration of dislocations under the influence of external forces. If dislocations are produced and migrated under the action of local forces, then material shape change can occur without the application of surface forces. We investigate how particles with variable diameters can be embedded in colloidal monolayers to produce dislocations on demand. Additionally, we find in simulation that when embedded clusters of variable diameter particles are taken through multiple cycles of swelling and shrinking, large cumulative plastic slip is produced by the creation and biased motion of dislocation pairs in the solid for embedded clusters of particular geometries. In this way, dislocations emitted by these clusters (biased “dislocation emitters”) can be used to reshape colloidal matter. Our results are also applicable to larger-scale swarms of robotic particles that organize into dense ordered two-dimensional (2D) arrangements. We conclude with a discussion of how dislocations fulfill for colloids the role sought by “metamodules” in lattice robotics research and show how successive applications of shear as a unit operation can produce shape change through slicing and swirling.

36 MATERIALS SCIENCE↗

Flexible positioning of a large area detector using an industrial robot

The DIAD beamline for Dual Imaging and Diffraction at Diamond Light Source has opted to use an industrial robot to position its Dectris Pilatus 2M CdTe diffraction detector. This setup was chosen to enable flexible positioning of the detector in a quarter-sphere around the sample position whilst reliably holding the large weight of 139 kg of detector, detector mount and cabling in a stable position. Metrology measurements showed that the detector can be positioned with a linear repeatability of <19.7 µm and a rotational repeatability of <16.3 µrad. The detector position stays stable for a 12 h period with <10.1 µm of movement for linear displacement and <3.8 µrad for rotational displacement. X-ray diffraction from calibration samples confirmed that the robot is sufficiently stable to resolve lattice d-spacings within the instrumental broadening given by detector position and beam divergence.

36 MATERIALS SCIENCE↗

An Online Change of Activity in Energy Spectrum for Detection on an Early Intervention Robot

With the growth of industrial risks and the multiplication of CBRNe (Chemical Biological Radiological and explosive) attacks through toxic chemicals, biological or radiological threats, public services and military authorities face with increasingly critical situations, whose management is strongly conditioned by fast and reliable establishment of an informative diagnostic. Right after an attack, the five first minutes are crucial to define the various scenarios and the most dangerous for a human intervention. Therefore the use of robots is considered essential by all stakeholders of security. In this context, the SISPEO project (Systeme d'Intervention Sapeurs Pompiers Robotise) aims to create/build/design a robust response through a robotic platform for early intervention services such as civil and military security in hostile environments. CEA LIST has proposed an adapted solution to detect and characterize nuclear and radiological risks online and in motion, using a miniature embedded CdZnTe (CZT) crystal Gamma-ray spectrometer. This paper presents experimental results for this miniature embedded CZT spectrometer and its associated mathematical method to detect and characterize radiological threats online and in motion. (authors)

42 ENGINEERING↗

High energy density picoliter-scale zinc-air microbatteries for colloidal robotics

The recent interest in microscopic autonomous systems, including microrobots, colloidal state machines, and smart dust, has created a need for microscale energy storage and harvesting. However, macroscopic materials for energy storage have noted incompatibilities with microfabrication techniques, creating substantial challenges to realizing microscale energy systems. Here, we photolithographically patterned a microscale zinc/platinum/SU-8 system to generate the highest energy density microbattery at the picoliter (10 −12 liter) scale. The device scavenges ambient or solution-dissolved oxygen for a zinc oxidation reaction, achieving an energy density ranging from 760 to 1070 watt-hours per liter at scales below 100 micrometers lateral and 2 micrometers thickness in size. The parallel nature of photolithography processes allows 10,000 devices per wafer to be released into solution as colloids with energy stored on board. Within a volume of only 2 picoliters each, these primary microbatteries can deliver open circuit voltages of 1.05 ± 0.12 volts, with total energies ranging from 5.5 ± 0.3 to 7.7 ± 1.0 microjoules and a maximum power near 2.7 nanowatts. We demonstrated that such systems can reliably power a micrometer-sized memristor circuit, providing access to nonvolatile memory. We also cycled power to drive the reversible bending of microscale bimorph actuators at 0.05 hertz for mechanical functions of colloidal robots. Additional capabilities, such as powering two distinct nanosensor types and a clock circuit, were also demonstrated. The high energy density, low volume, and simple configuration promise the mass fabrication and adoption of such picoliter zinc-air batteries for micrometer-scale, colloidal robotics with autonomous functions.

Robotics↗

Operational control with set-points tuning - application to mobile robots

This paper proposes a novel method for the optimal tuning of set points for multiple-layered control system structure widely seen in robotics and other complex industrial processes composed of a number of subsystems. The terminal sliding mode control (SMC) is used as the low-level control strategy to ensure the stability of subsystems. When uncertainties exist, it can be shown that the deteriorated system performance will be improved by the outer loop with set points tuning. For this purpose, the learning of the new set point is designed to compensate for the effects caused by uncertainties during the system operation. At the same time, the system is proven to stay with the original set point when the compensation is introduced. A practical application to a holonomic mobile robot system is given to illustrate the presented method. Desired results have been obtained.

42 ENGINEERING↗