Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power System Operation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Performance Evaluation of an Additively Manufactured ultra-High Operating Temperature SiC Solar-Thermal Air Receiver (HOTSSTAR) Test Module

Increasing operating temperatures of solar receivers is paramount to the efficiency of concentrated solar thermal and solar power systems. GE Aerospace Research in collaboration with Heliogen Inc and Sandia National Laboratories (SNL) is engaged in the development of ultra-High Operating Temperature SiC-matrix Solar Thermal Air Receiver (HOTSSTAR) enabled by additive manufacturing. HOTSSTAR goal is to demonstrate SiC receiver with air exit temperatures up to 1100oC. We discuss fabrication and on-sun test results of a prototype 50kWth test module. The receiver architecture is based on a radial airflow design and consists of a series of radial SiC receiver sectors organized around central absorber. These components were fabricated using binder-jet printed SiC followed by melt-infiltration reaction bonding process. To enhance the thermo-mechanical reliability of SiC test articles in thermal gradient/ shock environment of the application, the components were laminated with GE’s MI SiC CMC. A dedicated test facility was constructed at SNL Solar Tower to evaluate the operational performance of HOTSSTAR module under solar fluxes >200 W/cm2. We report on our final 50kW test module fabrication, integration at the test facility at Sandia, and discuss on-sun test results. We compare the performance of HOTSSTAR module relative to our model predictions.

14 SOLAR ENERGY↗

Emerging Trends and Systemic Issues Influencing Today’s U.S. Electric Grid

With increasing shifts from vertically integrated to horizontally structured operations and from centralized to distributed electric power delivery, today’s electric power grid (the “grid”) operators and designers face the challenge of creating an architecture that accommodates a host of diverse requirements. The grid’s modes of operation must address concerns of reliability and stability, new deployments of renewable energy sources, threats from cyber-attacks and natural disasters, and increasingly distributed system operations. Grid modernization calls for a reliable, affordable, sustainable, agile, secure, and resilient grid. However, the modernization of the U.S. power grid is hampered by mounting complexity and diverging objectives from owners and operators and is consequently risky and fraught with potential missteps. Flawed architecture, design, and implementation will lead to stranded investments and lost opportunities. A principled approach to minimize risk and develop a robust grid of the future is to begin with a sound architecture for the grid to inform the design process. Architecture development starts with the context of influencing factors that provide constraints as well as driving goals. This report provides the context of emerging trends and cross-cutting systemic issues in the U.S. electric power grid and serves as a vital input for grid architecture development.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhanced Frequency Support Scheme of Generic Inverter-Based Resource Models for Renewable-Dominated Power Grids

The frequency response of SG-dominated power grids is predictable ahead of an occurrence of a frequency event because the frequency response of SGs is consistent, and it can be inferred from the swing equation [1]. However, increasing the portion of IBRs in an SG-dominated power grid might make the characteristics of the conventional power grids no longer valid because this changing resource mix affects grid dynamics and controls [2]. Thus, maintaining these characteristics greatly benefits the control and operation of the power grids with high penetration of IBRs. To maintain these characteristics in IBR-dominated power grids, IBRs should have frequency response capability similar to that of an SG. The WECC modeling validation subcommittee has developed generic IBR models for large system planning [3]-[5]. These models can represent various vendors' dynamic behavior for WTG, PV, and ESS [5]. The current generic IBR models approved by WECC can provide frequency response only from droop control loops in REPC models [6], [7]. The contribution of the loops is proportional to the frequency deviation from the nominal frequency. Thus, it presents an insufficient contribution to arrest frequency variation compared to the frequency response of SGs because it allows a high ROCOF in the early stage of frequency events. This shortfall will become greater as the PL of IBRs increases in power grids. Controller enhancement for the generic IBR models is required to secure the frequency stability under high PL of IBRs as in the SG-dominated power grids. This paper proposes a control extension for the generic IBR models to enhance the frequency support capabilities and discusses the classification of frequency support for the different types of IBR considering their operating constraints. An inertial control scheme is implemented in the REPC and REEC models of the generic IBR models to achieve these objectives. The inertial control scheme includes the following stages: Control area data acquisition, inertia time constant estimation, IBR-related constraint check, IBR contribution determination, and inertial response provision. In the scheme, a REPC acquires control area data from a system operator and estimates a total inertia time constant for the control area the applicable IBR power plant belongs. Then, the estimated inertial time constant is transferred to each IBR controller—REEC—within the power plant. Each REEC checks the availability of applicable IBR for inertial response participation. If the IBR is available, the REEC amplifies the estimated inertial time constant to utilize it for inertial response provision. In this way, the proposed inertial response scheme extends the functionality of the generic IBR models to provide SG-like frequency response within their constraints. Various scenarios considering different IBR types, IBR penetration levels, and frequency control schemes were simulated and compared in an IEEE 39-bus system using PSCAD simulator to verify the effectiveness of the proposed scheme.

Kim, Jinho↗

Organic Rankine Cycle Integration and Optimization for High Efficiency CHP Genset Systems (Final Technical Report)

This project successfully advanced the integration of Organic Rankine Cycle (ORC) technology with reciprocating engine–based combined heat and power (CHP) systems to improve electrical efficiency, total CHP efficiency, and grid-responsive operation. Over three budget periods, the work progressed from high-temperature ORC component development and thermodynamic model validation to next-generation system design, working fluid transition, and techno-economic analysis. Key technical accomplishments include development and validation of a thermodynamic model capable of accurately predicting ORC performance across an expanded temperature and pressure envelope; successful identification and validation of low-global-warming-potential (GWP) working fluids—most notably R1233zd(E)—as viable replacements for R245fa; and demonstration of scalable ORC architectures suitable for integration with 1–20 MW class reciprocating engines. These advances enable flexible CHP configurations that can increase electrical output while maintaining high overall utilization of available thermal energy. The project also produced a clean-sheet design for a next-generation ORC system targeting substantially higher power output per unit, supported by detailed component selection, heat exchanger evaluation, and system-level modeling. Techno-economic analyses indicate that ORC-enabled flexible CHP systems can meet or exceed Department of Energy (DOE) efficiency targets while providing value to both facility operators and the electric grid.. Late-stage testing of the largest next-generation ORC prototype identified limitations related to pump net positive suction head (NPSH) requirements and condenser flooding under certain operating conditions. Although these issues constrained full validation of that configuration within the project timeframe, they provided clear and actionable design guidance for future system refinements. Importantly, validated modeling, smaller-scale testing, and working fluid evaluations confirmed the technical viability of the overall approach. In aggregate, this project met its core objectives by establishing validated design tools, de-risking key ORC technologies for CHP applications, and defining a credible pathway toward commercialization of flexible, high-efficiency CHP systems. The results form a strong foundation for continued development and deployment beyond the conclusion of the DOE-funded effort.

20 FOSSIL-FUELED POWER PLANTS↗

Testing of Instrumentation and Control Sensors and Cables for Small Modular Reactors

As advanced reactor concepts like small modular reactors (SMRs) progress towards design maturity and commercial deployment, it is important to assess their instrumentation and control (I&C) system sensors and cables to assure their safe, reliable, and efficient operation throughout their service lifetimes. The I&C system of any nuclear power plant (NPP) is the central nervous system of the plant and is made up of field devices such as sensors which are connected via cables to analog and/or digital systems. These systems are responsible for control and/or protection of the plant. The performance of I&C sensors and cables is dependent on several factors, including plant operating conditions. In particular, the plant operation can affect the static (accuracy) and dynamic (response) performance of the sensor, whereas the surrounding ambient environment can impact the remaining useful life of the cables, connectors, and other associated components within I&C sensor circuits.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced Anode for Internal Reforming and Thermal Management in Solid Oxide Fuel Cells

Solid oxide fuel cell (SOFC) is an efficient and clean electrical power generation system compared to conventional combustion based technologies with energy efficiency reaching as high as 85-90% in co-generation mode (electricity and heat). Other advantages of SOFCs are hybridization, modularity of construction, small CO 2 foot print per kWh of generated electricity and fuel flexibility. Hydrocarbons present in the gaseous fuel is utilized in SOFCs by internal or external reforming. There are two different internal reforming concepts: Direct Internal Reforming (DIR) and Indirect Internal Reforming (IIR). For DIR operation, the endothermic reforming reaction and the exothermic reaction from the oxidation reaction are operated together in the single unit eliminating the requirement for a separate fuel reformer. This configuration also simplifies the overall system design, making SOFC more attractive and efficient means of producing electrical power. The main advantage of the DIR type of operation is that the H 2 or CO consumption by the electrochemical reaction could directly promote the conversion of methane at the anode side of the fuel cell resulting in high conversion and high efficiency. The DIR operation, however, requires an anode material that has desired dual catalytic (hetero and electro) properties for reforming reaction and electrochemical reactions. The anode materials also need to remain resistant to carbon formation at the operating temperature and atmosphere with stable cell performance. Another requirement is to match the reforming reactions and electrochemical reactions to avoid local cooling or overheating, which can result in mechanical failure due to thermally induced stresses. Direct internal reforming (DIR) of hydrocarbon fuels simplifies the overall SOFC system design making it more attractive and efficient for producing electrical power. Low cost alloy anodes for distributed internal reforming of methane and other hydrocarbon fuels offer increased fuel-flexibility, reliability, and long term performance stability of solid oxide fuel cells (SOFC). The research program examined modification of the chemical compositions and microstructure of high entropy alloy (HEA) anode materials using thermochemical calculations and process simulation and modeling to achieve distributed reforming over the entire anode to eliminate hot zones. Cell fabrication and testing of the HEA anodes using button cell configuration has been performed to demonstrate the advantages of new anode over traditional Ni-YSZ anodes for distributed reforming and carbon free operation. Technical accomplishments include identification and synthesis of HEA carbon-resistant anode, demonstration of reduction in reforming rate confirmed by GC and modelling data validating effectiveness for thermal management in cell/stacks, electrochemical testing of HEA anode in single cell (HEA-GDC||YSZ||LSM-YSZ) and Characterization of pretest and posttest anode materials by TEM and SEM-EDS confirming carbon-free operation.

30 DIRECT ENERGY CONVERSION↗

Control System of Multi-Port Autonomous Reconfigurable Solar Power Plant (MARS) & HIL Platforms for Design

Multi-port autonomous reconfigurable solar power plant (MARS) provides an attractive alternative to connect photovoltaic (PV) and energy storage systems (ESSs) to high-voltage direct current (HVdc) links and high-voltage alternating current (ac) grids. In this paper, a unique hierarchical control system of MARS is proposed and evaluated. To evaluate the control system and associated algorithms in early-stage research of complex architectures like MARS, it is important to develop unique suitable hardware-in-the-loop (HIL) platforms. In this paper, the HIL platforms for MARS to evaluate the performance of the hierarchical control system and the control algorithms implemented are presented. Further, they help with the design process of control systems. The real-time simulation models and algorithms that are utilized for MARS in the HIL platforms are also discussed in the paper. The HIL experiments of the control system of MARS showcase the capability to provide continuity of operation under faults and frequency support to the power grid during loss of generation. They also showcase the stability of the proposed hierarchical control system of MARS.

14 SOLAR ENERGY↗

An Enhanced Computational Framework for Energy Storage Participation in Transmission Planning with Electricity Market Participation: Dynamic Market Participation Restriction Estimation

In the previous study and report, we developed a computational framework to explore the technical and economic viability of the dual use of pumped storage hydropower (PSH) for both transmission assets and market participation. The rationale for the dual-use application is to improve the resource utilization rate and reduce the cost recovery burden. A PSH-based transmission solution generally has a large capacity, which corresponds to a higher investment cost compared to a traditional line solution. Market participation may allow the PSH asset to offset part of its high investment cost. A critical question is whether it is economically and technically viable to allow dual use of a PSH-based transmission project without jeopardizing transmission system reliability. And a more specific follow-up question is how to improve market participation performance while maintaining transmission reliability. In this study, we extend the computational framework by updating the method to determine transmission service obligation requirements dynamically based on the possibility of the need for transmission service in operation. Specifically, we correlate the need for transmission service with the probability of thermal overloading on a monitored transmission line, which is essentially based on the probability distribution of power flow and its probability of exceeding the line rating based on system dispatch and operational uncertainties. In addition, the need depends on the level of risk that a system operator is willing to take. The higher the risk tolerance, the lower the requirement that the system operator would apply to the PSH project as a transmission asset. The requirements are updated every day before the PSH project determines its market participation strategy. With the updated transmission service requirements, it is expected that a PSH project can serve as a transmission asset when the transmission system is at risk and really needs it, while it can participate in a market with sufficient information and certain restrictions. In this way, the transmission service quality and market participation performance can both be improved.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Online Output-Based Inertia Estimation of Modern Power Systems

The overall inertia of modern power systems is drastically impacted by the penetration level of converter-based resources (CBRs). The intermittent output of CBRs and their dependence on the weather conditions affirm the need for a realtime inertia estimation approach. This can help the transmission system operators(TSOs) to be continuously aware of the changes in the system inertia and to take suitable control actions. This paper is a step forward to a totally data-driven framework for power system inertia estimation using the available measurements from the phasor measurement units (PMUs). This inertia estimation is done based on the spectral analysis of the so-called Koopman linear operator. Koopman operator considers the relationship between the system's inertia and its dynamical response to slight disturbances in the load. Simulation results show that Koopman operator can approximate the system behavior in a reconstructed linear space hence inertia constant is estimated accurately.

data-driven↗

Refractory-based thermal energy storage for industrial process heat: one-dimensional modeling, control, and optimization

The variable and weather-dependent output of wind and solar power plants present a substantial challenge for planning and operating electricity-systems, particularly in the absence of cost-effective and dispatchable energy storage technologies. This study investigates a high-temperature, electrically heated, refractory-based thermal energy storage (RTES) system that stores electrical energy as sensible heat in dense ceramic bricks over the 950–1800 °C range. The stored heat can be discharged as a controlled hot-gas stream for industrial heating, fuel substitution in high-temperature processes, or electricity generation. The main novelty is a comprehensive modelling, control, mapping, and optimization framework that integrates one-dimensional transient gas–solid heat transfer, fan-assisted discharge, bypass-flow regulation, reheating logic, fan-power evaluation, insulation-loss assessment, and genetic-algorithm-based design optimization. The model uses feedback from outlet temperature and delivered power to regulate discharge, while a two-stage genetic algorithm optimizes brick-channel geometry, gas-flow operation, and multilayer insulation thicknesses. Storage capacities below 50 MWh and discharge powers of 5–30 MW are analyzed to evaluate hold time, thermal delivery, fan-power penalty, heat loss, state-of-charge evolution, and indicative capital cost. Results demonstrate that optimized and well-insulated refractory-based thermal energy storage units can provide stable, efficient, and repeatable heat delivery over multiple discharge cycles. The generated performance and cost maps support modular refractory thermal energy storage as a practical option for large-scale integration of wind and solar generation and for high-temperature industrial process heat.

25 ENERGY STORAGE↗

High Temperature Ceramic Heat Exchangers for the Gen3 Concentrated Solar Power Systems

As part of the Department of Energy’s Solar Energy Technology Office (SETO), the Concentrated Solar Power (CSP) Gen3 Demonstration Roadmap outlined the various technology pathways, goals, and technology needs/gaps to integrate CSP to a supercritical CO 2 (sCO 2 ) power cycle that operates at temperatures >700 °C. It is envisioned that the higher temperature power cycle will enhance the overall system efficiencies and reduce the levelized cost of electricity (LCOE) to meet a 2030 cost target of $0.05/kWhe for baseload CSP plants with ≥12 hours of storage. In this regard, there is a need for heat exchangers (HXs) that can operate at high sCO 2 pressures and temperatures >700 °C. Since current high-temperature alloys degrade at high temperatures, as part of this project, advanced ceramic materials, HX designs, and low-cost additive manufacturing approaches were developed to fabricate and evaluate the performance of the lab-scale ceramic HX prototypes.

14 SOLAR ENERGY↗

Scalable Unit Commitment with Security Constrained AC Power Flow via ADMM and Hybrid Modeling Strategies

This research introduces a more efficient way to optimize power grid operations, breaking the problem into manageable steps and using advanced mathematical techniques to speed up calculations. By incorporating smart heuristics, improved preprocessing, and contingency analysis, the approach allows operators to make better decisions faster. These innovations enhance our understanding of how to optimize energy generation, making it possible to anticipate failures before they happen, reduce system costs, and improve overall grid performance. Ultimately, this research helps bridge the gap between theoretical models and real-world applications, paving the way for a smarter, more resilient power grid. This research directly benefits the public by making electricity more affordable, reliable, and sustainable. By improving how power grids schedule and distribute electricity, the project helps energy providers reduce operational costs, which can lead to lower electricity prices for consumers. Additionally, the ability to predict and prevent power system failures enhances grid reliability, reducing the likelihood of blackouts that can disrupt homes, businesses, and critical infrastructure such as hospitals. From an environmental perspective, optimizing power generation reduces energy waste and lowers carbon emissions, contributing to cleaner air and a more sustainable energy system. Furthermore, with extreme weather events becoming more frequent, these advancements make the power grid more resilient, ensuring communities are better prepared for emergencies and natural disasters. By strengthening the nation's energy infrastructure, this research plays a crucial role in improving economic stability, public safety, and environmental sustainability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluation of the Turbine Integrated Mortality Reduction (TIMR SM ) Technology as a Smart Curtailment Approach (Final Summary Report)

Wind energy is a crucial technology for achieving net-zero emissions by 2050. However, the growth and deployment of wind energy in North America have led to the deaths of many bat species due to operating wind turbines. Hundreds of thousands of bats are estimated to die at wind turbines annually in North America. Operational minimization, which includes feathering turbine blades and curtailment, has been documented to reduce bat fatality effectively. Curtailment refers to altering turbine operation based on wind speed, time of year, temperature, sensors, and activity models. However, when turbines are curtailed, they do not generate power, resulting in energy loss and revenue for wind energy facilities. The Electric Power Research Institute (EPRI) funded the development of Turbine Integrated Mortality Reduction (TIM SM ) Technology, which curtails turbine operation when bats are detected. The initial TIMR system research showed promising results, with an 85% reduction in overall bat fatalities and a 91% reduction for the little brown bat. However, these results were based on a single site during one fall season, and it was unclear if similar results could be replicated at other wind energy facilities. This research aimed to validate the TIMR system results from the prior field study at a second site in the U.S., estimate the power production and reduction in bat mortality at turbines with installed TIMR systems relative to blanket curtailment and fully operational turbines, test the TIMR system in two calendar years and during the summer and fall periods, and evaluate the operational and commercial characteristics of the TIMR system for potential wind industry adoption. The study was conducted at a 500.9-MW wind energy facility in southeast Adair County, Iowa. Three experimental treatments were involved in this randomized block design study: TIMR, Curtailment at 5.0 m/s, and Normal Operation. In 2021, three treatments were used at 18 turbines, expanding to four treatments across 36 turbines in 2022. The TIMR system worked as designed throughout the entire study; however, because of unexpected wind turbine operational challenges in 2021, there was not sufficient sample size to evaluate the treatment differences. In 2022, there were significant differences in fatality levels between treatment types and normal operating turbines. Curtailment at 5.0 m/s reduced fatalities by 30.8% compared to normal operations, and TIMR decreased fatalities by 48.6% compared to normal operations. Two different methods were used to evaluate the differences in energy loss for each treatment. The TIMR system resulted in 1.3% to 1.6 % annual energy loss in 2021 and 1.0% to 1.2 % in 2022. The Curtailment at 5.0 m/s resulted in 0.6% to 0.8 % annual energy loss in 2021 and 0.5% to 0.6 % in 2022. The project achieved all the stated objectives and demonstrated that TIMR is an effective technology that balances bat fatality reduction with energy generation. The results will support the deployment of TIMR and other acoustic sensor-based technologies. The research provides valuable insights into the impact of different treatments on fatality rates and energy outputs, contributing to the ongoing efforts to mitigate the environmental impact of wind energy.

17 WIND ENERGY↗

A Generic and Multifunctional Electromagnetic Transient Model for Grid-Following Inverters

This paper presents a generic and multifunctional electromagnetic transient (EMT) dynamic model of grid-following (GFL) inverter-based resources (IBRs) using the PSCAD software platform. The features of the model include flexibility in selecting various types and combinations of DC sources covering photovoltaic modules, battery modules, and ideal DC-source modules as well as flexibility in selecting either switching or averaged models of the inverter. This model also covers exhaustive lists of controller algorithm, including open-loop/closed-loop PQ dispatch control, DC voltage and AC terminal voltage control, and conventional current control designed in the dq-domain, the ..alpha....beta.. -domain, and the positive-/negative-sequence domain. Moreover, this model is equipped with flexibility in selecting various types of current-limiting schemes, including saturation-based and latching-based current limiters, and anti-windup protection. Also, the EMT model is agnostic to the MVA rating and is suitable for interfacing transmission systems by complying with IEEE Std. 2800. The generality in the power circuits and the multifunctional options in the operation and control of the developed EMT model make it suitable for both academia and industry to study various power system aspects, including, but not limited to, the fault behavior of GFL IBRs, the impacts on the protection system, and the transient stability of a system interfaced with large numbers of GFL IBRs.

integrated circuit modeling↗

A Reinforcement Learning Approach to Augment Conventional PID Control in Nuclear Power Plant Transient Operation

The ability of nuclear reactors to operate their power conversion cycles more flexibly will enhance their value to energy grids with variable pricing. Current nuclear control systems are typically classical controllers that are often based on proportional-integral-derivative (PID) control. This paper presents a method of augmenting the existing PID control for difficult transient operations in nuclear power plants using a reinforcement learning–derived feedforward signal applied in real time. The agents, which are trained on a test thermal load-following problem, are designed to improve steam generator outlet temperature control for a range of fast load-following scenarios covering ramp rates from 9%/min to 15%/min. Several reinforcement learning algorithms were initially investigated for the training of the feedforward agents with deep Q-learning (DQN) and proximal policy optimization (PPO) networks, which were found to be the most promising. The DQN controllers utilize discrete actions, giving them a better disturbance rejection at steady state but inconsistent response to initial temperature deviations. In contrast, PPO-trained agents, which take continuous actions except for a dead zone around zero, were shown to have the best combination of high disturbance rejection at steady state and good tracking of the desired temperature value. The ability of the PPO agent was also examined, with the average time of decision making found to be on the order of 1 ms. The fault properties of the controller under the loss of the reinforcement learning agent feedforward signal were also examined. The controller showed strong performance in situations of “no-signal” faults. but was less good at handling “stuck-at” faults, where the feedforward signal remains at a set value. In both cases, however, the PID was able to successfully maintain stability, eventually returning the system to a steady state. It is hoped that this work will allow for the proposed control architecture to be examined for more difficult control problems such that it may eventually be used to adapt existing nuclear plants for more aggressive load-following on grids of the future.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Grid Resiliency with a 100% Renewable Microgrid

San Diego Gas & Electric Company (SDG&E) installed America’s first and largest utility-scale microgrid in Borrego Springs in 2013. The first generation Borrego Springs Microgrid utilized diesel generators to form and stabilize the microgrid island, with support from grid-scale batteries and local solar photovoltaic (PV) generation. In this project, SDG&E in partnership with National Renewable Energy Laboratory (NREL) demonstrated through modeling, simulation and utility field testing that blackstart and islanding of the microgrid can be led with 100% renewable, inverter based resources (IBRs), to help reduce community reliance on conventional generation resources. Through equipment upgrades, grid-forming island leader capability was transitioned to a battery IBR instead of the Borrego Springs Microgrid diesel generators. A new microgrid controller was integrated to the microgrid and programmed to control and manage multiple energy storage systems. Synchrophasor and other power quality data verified autonomous, high-speed response of the IBRs through blackstart, islanding, and load step testing. Results of project field evaluations provide distribution systems operators (DSO) with increased confidence that renewable, IBR can replace traditional generators to blackstart and island microgrids and rapidly establish stable island frequency with rapid changes in peak power demand. Importantly, the project validated the integration feasibility of a distributed energy resource management system (DERMS) controller that manages multiple grid-forming and grid-following IBRs, establishing a standard design interface to reduce the complexity of integrating new DERs in the future and supporting replication by the industry. As a result of learnings in this project, SDG&E has implemented the microgrid controller strategy at multiple other microgrid sites, thereby validating the replicability of the solution. Hardware-in-the-loop (HIL) simulations including power and controller HIL hardware — along with electromagnetic transient (EMT) simulations of Borrego Springs Microgrid —informed adjustments to inverter parameters and were important to characterize the performance of the IBRs in relevant operating conditions before deployment. The EMT and HIL simulations of islanding the entire community are important contributions in providing confidence in IBR performance prior to future islanding of the community in the field. High-fidelity EMT and/or HIL simulation of IBRs can de-risk field operations, and its relevance and importance as a tool is increasing as distribution grids and microgrids become more complex and dynamic with an increasing proportion of renewable generation, distributed energy storage, and two-way power and energy flows.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed Ledger Technology for Fault Tolerant Distribution Grid Operations

This paper explores the potential of distributed ledger technology (DLT) to improve fault-tolerant grid operations by leveraging its core features as an immutable, decentralized ledger, a distributed, consensus-based agreement process, and a distributed state-replication engine. Distribution power systems deliver electricity to millions of customers; however, they are susceptible to various threats that can result in customer interruptions. These include faults caused by adverse weather conditions, natural disasters, vegetation growth, equipment failure, and malicious attacks. To minimize the effects of these faults, fault-handling approaches rely on network knowledge to isolate affected areas and reconnect unaffected areas, reducing the number of affected customers while maintaining safety. Here, we present a trusted data-sharing architecture that enables independent, distributed actors to reconstruct the pre-fault system state by enabling distributed resources to make appropriate decisions with limited network/system information. Although the process requires some data sharing between switch-delimited areas, the approach limits the amount of private information shared, preserving customers' privacy and business-sensitive information. We include three use cases that form a foundation for third parties to develop functional solutions that can eventually be deployed in the field. The gross error detection method used within switch-delimited areas can identify sensor errors and accurately detect circuit breaker states. The evaluation of possible reconnection while preserving data ownership resulted in a voltage magnitude difference smaller than 0.001% from the OpenDSS power flow solution that has full system knowledge, which is below the expected power flow tolerance. The approach offers a promising opportunity for improving fault-tolerant distribution grid operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Achievement in Beam Power Records for the NOvA Target System

We began upgrading the NOvA target system for 1-Mega Watt (1-MW) beam operation in 2017. Major challenges included maintaining the quality of neutrino beams with reliable instrumentation, reducing instantaneous beam heating on the target, increasing cooling power to handle the high-power beam, and controlling tritium water production rate. We finally achieved a one-hour beam power record of 1.018 MW in Summer 2024. This milestone demonstrates our capability to operate at 2+ MW beam power for the future Long Baseline Neutrino Facility (LBNF) and Deep Underground Neutrino Experiment (DUNE).

43 PARTICLE ACCELERATORS↗