Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “POSITRON”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

TU-F-12A-01: Quantitative Non-Linear Compartment Modeling of 89Zr- and 124I- Labeled J591 Monoclonal Antibody Kinetics Using Serial Non-Invasive Positron Emission Tomography Imaging in a Pre-Clinical Human Prostate Cancer Mouse Model

Purpose: To examine the binding kinetics of human IgG monoclonal antibody J591 which targets prostate-specific membrane antigen (PSMA) in a pre-clinical mouse cancer model using quantitative PET compartmental analysis of two radiolabeled variants. Methods: PSMA is expressed in normal human prostate, and becomes highly upregulated in prostate cancer, making it a promising therapeutic target. Two forms of J591, radiolabeled with either {sup 89}Zr or {sup 124}I, were prepared. {sup 89}Zr is a radiometal that becomes trapped in the cell upon internalization by the antigen-antibody complex, while radioiodine leaves the cell. Mice with prostate cancer xenografts underwent non-invasive serial imaging on a Focus 120 microPET up to 144 hours post-injection of J591. A non-linear compartmental model describing the binding and internalization of antibody in tumor xenograft was developed and applied to the PET-derived time-activity curves. The antibody-antigen association rate constant (ka), total amount of antigen per gram tumor (Ag-total), internalization rate of antibody-antigen complex, and efflux rate of radioisotope from tumor were fitted using the model. The surface-bound and the internalized activity were also estimated. Results: Values for ka, Ag-total, and internalization rate were found to be similar regardless of radiolabel payload used. The efflux rate, however, was ∼ 9-fold higher for {sup 124}I-J591 than for {sup 89}Zr-J591. Time-dependent surface-bound and internalized radiotracer activity were similar for both radiolabels at early times post-injection, but clearly differed beyond 24 hours. Conclusion: Binding and internalization of J591 to PSMA-expressing tumor xenografts were similar when radiolabeled with either {sup 89}Zr or {sup 124}I payload. The difference in efflux of radioactivity from tumor may be attributable to differential biological fate intracellularly of the radioisotopes. This has great significance for radioimmunotherapy and antibody-drug conjugates. Further exploration using the model will examine binding and radioisotope residence as antibody dose is increased to antigen saturation. The Center for Targeted Radioimmunotherapy and Theranostics, Ludwig Center for Cancer Immunotherapy, Memorial Sloan Kettering Cancer Center (MSK), NIH (R25-CA096945). Technical services provided by the MSK Small-Animal Imaging Core Facility were supported by the NIH (R24-CA83084, P30-CA08748, and P50-CA92629; Zanzonico). NCI, Center to Reduce Cancer Health Disparity (R21 CA153177-03; Osborne)

60 APPLIED LIFE SCIENCES↗

WE-G-BRF-06: Positron Emission Tomography (PET)-Guided Dynamic Lung Tumor Tracking for Cancer Radiotherapy: First Patient Simulations

Purpose: PET-guided dynamic tumor tracking is a novel concept of biologically targeted image guidance for radiotherapy. A dynamic tumor tracking algorithm based on list-mode PET data has been developed and previously tested on dynamic phantom data. In this study, we investigate if dynamic tumor tracking is clinically feasible by applying the method to lung cancer patient PET data. Methods: PET-guided tumor tracking estimates the target position of a segmented volume in PET images reconstructed continuously from accumulated coincidence events correlated with external respiratory motion, simulating real-time applications, i.e., only data up to the current time point is used to estimate the target position. A target volume is segmented with a 50% threshold, consistently, of the maximum intensity in the predetermined volume of interest. Through this algorithm, the PET-estimated trajectories are quantified from four lung cancer patients who have distinct tumor location and size. The accuracy of the PET-estimated trajectories is evaluated by comparing to external respiratory motion because the ground-truth of tumor motion is not known in patients; however, previous phantom studies demonstrated sub-2mm accuracy using clinically derived 3D tumor motion. Results: The overall similarity of motion patterns between the PET-estimated trajectories and the external respiratory traces implies that the PET-guided tracking algorithm can provide an acceptable level of targeting accuracy. However, there are variations in the tracking accuracy between tumors due to the quality of the segmentation which depends on target-to-background ratio, tumor location and size. Conclusion: For the first time, a dynamic tumor tracking algorithm has been applied to lung cancer patient PET data, demonstrating clinical feasibility of real-time tumor tracking for integrated PET-linacs. The target-to-background ratio is a significant factor determining accuracy: screening during treatment planning would enable appropriate patient selection for PET-guided dynamic tumor tracking in radiotherapy.

60 APPLIED LIFE SCIENCES↗

A combined time-of-flight and depth-of-interaction detector for total-body positron emission tomography

Purpose: In support of a project to build a total-body PET scanner with an axial field-of-view of 2 m, the authors are developing simple, cost-effective block detectors with combined time-of-flight (TOF) and depth-of-interaction (DOI) capabilities. Methods: This work focuses on investigating the potential of phosphor-coated crystals with conventional PMT-based block detector readout to provide DOI information while preserving timing resolution. The authors explored a variety of phosphor-coating configurations with single crystals and crystal arrays. Several pulse shape discrimination techniques were investigated, including decay time, delayed charge integration (DCI), and average signal shapes. Results: Pulse shape discrimination based on DCI provided the lowest DOI positioning error: 2 mm DOI positioning error was obtained with single phosphor-coated crystals while 3–3.5 mm DOI error was measured with the block detector module. Minimal timing resolution degradation was observed with single phosphor-coated crystals compared to uncoated crystals, and a timing resolution of 442 ps was obtained with phosphor-coated crystals in the block detector compared to 404 ps without phosphor coating. Flood maps showed a slight degradation in crystal resolvability with phosphor-coated crystals; however, all crystals could be resolved. Energy resolution was degraded by 3%–7% with phosphor-coated crystals compared to uncoated crystals. Conclusions: These results demonstrate the feasibility of obtaining TOF–DOI capabilities with simple block detector readout using phosphor-coated crystals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Poster – 02: Positron Emission Tomography (PET) Imaging Reconstruction using higher order Scattered Photon Coincidences

PET images are affected by the presence of scattered photons. Incorrect scatter-correction may cause artifacts, particularly in 3D PET systems. Current scatter reconstruction methods do not distinguish between single and higher order scattered photons. A dual-scattered reconstruction method (GDS-MLEM) that is independent of the number of Compton scattering interactions and less sensitive to the need for high energy resolution detectors, is proposed. To avoid overcorrecting for scattered coincidences, the attenuation coefficient was calculated by integrating the differential Klein-Nishina cross-section over a restricted energy range, accounting only for scattered photons that were not detected. The optimum image can be selected by choosing an energy threshold which is the upper energy limit for the calculation of the cross-section and the lower limit for scattered photons in the reconstruction. Data was simulated using the GATE platform. 500,000 multiple scattered photon coincidences with perfect energy resolution were reconstructed using various methods. The GDS-MLEM algorithm had the highest confidence (98%) in locating the annihilation position and was capable of reconstructing the two largest hot regions. 100,000 photon coincidences, with a scatter fraction of 40%, were used to test the energy resolution dependence of different algorithms. With a 350–650 keV energy window and the restricted attenuation correction model, the GDS-MLEM algorithm was able to improve contrast recovery and reduce the noise by 7.56%–13.24% and 12.4%–24.03%, respectively. This approach is less sensitive to the energy resolution and shows promise if detector energy resolutions of 12% can be achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Collective excitations in optical spectra of nanosize exciton and electron-positron droplets

We study the optical properties of nanosize two-component Fermi systems. The photoabsorption spectra in Fermi systems containing not more than 10{sup 2} pairs of oppositely charged particles are calculated. The main focus is on the role of collective plasmon excitations. The dependences of the position of the plasmon resonance on the number of particles and the ratio of their masses in the system are investigated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Compilation and analysis of charge asymmetry measurements from electron and positron scattering on nucleon and nuclei

World data on the lepton-charge asymmetry in the elastic and inelastic lepton scattering off the proton and nuclei are compiled and discussed. After reviewing the published results, we compare the elastic data to a model calculation of the two-photon-exchange mechanism. We show that the existing data do not provide any evidence for enhancement of the two-photon contribution. At confidence level 95% the data allow to exclude the two-photon exchange as an explanation for the difference between Rosenbluth and polarization transfer measurements of proton electromagnetic form factors.

74 ATOMIC AND MOLECULAR PHYSICS↗

New results of measurement of cross sections for electron-positron annihilation to hadrons with the SND detector at VEPP-2000

A survey of preliminary results of experiments with the SND detector at the VEPP-2000 e{sup +}e{sup −} collider in the energy range of √s = 1000–2000 MeV MeV is presented. The cross sections for the processes e{sup +}e{sup −} → π{sup 0}π{sup 0}γ, e{sup +}e{sup −} → π{sup +}π{sup −}π{sup 0}π{sup 0}, e{sup +}e{sup −} → π{sup +}π{sup −}π{sup 0}, e{sup +}e{sup −} → π{sup +}π{sup −}η, and e{sup +}e{sup −} → pp̄ were measured. The measured cross sections agree with the results of earlier measurements but have a higher precision. The cross section for the process e{sup +}e{sup −} → ηγ in the energy range extending from 1.4 to 2 GeV was measured for the first time. The ratio G{sub E}/G{sub M} for the neutron was measured for the first time in the timelike region.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Study of strange charmed baryons in electron–positron collisions

A modern classification of charmed baryons is presented, and the quark model is briefly described for the ground states and energy levels of excited states. In addition, a survey of experimentally observed states of strange charmed baryons is given.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nonlinear theory of ion-acoustic waves in an electron-positron-ion plasma

An analytical nonlinear gasdynamic theory of ion-acoustic waves in an e-p-i plasma is developed for the case in which all the plasma components in the wave undergo polytropic compression and rarefaction. An exact solution to the basic equations is found and analyzed by the Bernoulli pseudopotential method. The parameter range in which periodic waves can propagate and the range in which solitary waves (solitons) exist are determined. It is shown that the propagation velocity of a solitary is always higher than the linear ion sound velocity. The profiles of all the physical quantities in both subsonic and supersonic waves are calculated. The results obtained agree well with both the data from other papers and particular limiting cases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Molecular dynamic simulations of electric microfield distributions in a nonideal electron-positron plasma

A symmetric model of a two-component plasma is considered and the distributions of electric microfields acting on charged and neutral particles are calculated using the method of molecular dynamics at a fixed temperature of T = 30000 K and different values of the coupling parameter 0.2 {<=} {Gamma} {<=} 1.2. Changes in these distributions with varying {Gamma} are discussed. Special attention is paid to the behavior of the distribution tails. The behavior of these tails at a neutral point is shown to agree with the tails of the Holtsmark distribution, whereas the tails of the distribution at a charge are considerably heavier and are characterized by the exponent that varies within the range from -2.2 up to -1.8 as {Gamma} increases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Steady states of a diode with counterstreaming electron and positron beams

Steady states of a plasma layer with counterstreaming beams of oppositely charged particles moving without collisions in a self-consistent electric field are analyzed. The study is aimed at clarifying the mechanism of generation and reconstruction of pulsar radiation. Such a layer also models the processes occurring in Knudsen plasma diodes with counterstreaming electron and ion beams. The steady-state solutions are exhaustively classified. The existence of several solutions at the same external parameters is established.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Preliminary Report on the Evaluation of an Electron-Positron Collider as a source of Monoenergetic Photons

Abstract Active interrogation methods are being investigated to detect shielded special nuclear material (SNM). These approaches utilize either neutron or photon beams to excite the SNM in concert with either neutron or gamma ray detectors to observe the stimulated emissions. The two primary methodologies with photon beams are photofission and nuclear resonance florescence (NRF). Photofission requires photons energies of 7-10 MeV while NRF requires photon energies around 2 MeV. For both techniques, photons that are not in the appropriate energy band, e.g. the low energy tail of a Bremsstrahlung photon beam, contribute unwanted additional radiation dose to cargo. Typically less than 10% of the photons are in the usable energy band. The additional photon production generates a commensurate amount of additional radiation dose in the source and target areas, impacting shielding requirements and/or dose to operators and equipment and at the expense of a similar increase in power consumption. Hence it is highly desirable to produce narrow energy (“monoenergetic”) photon beams with tunable energy in the range of ~2-20 MeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Storage Rings for Science with: Electron-Positron Collisions, Hadron Collisions and Synchrotron Light

The author is honored to receive the 2009 Robert Wilson Prize and the recognition that comes with it. The citation for the prize reads, 'For his outstanding contribution to the design and construction of accelerators that has led to the realization of major machines for fundamental science on two continents and his promotion of international collaboration.' In this article, he will discuss the two construction projects, which he led, one (TRISTAN e{sup +}e{sup -} Collider at KEK) in Japan and the other (RHIC at BNL) in the USA, covering project issues and lessons learned from these projects. Although both of them were built on separate continents, it is interesting to note that they are both built on long off-shore islands. He will also add comments on his recent engagement in the development of the Conceptual Design for the National Synchrotron Light Source II (NSLS-II).

43 PARTICLE ACCELERATORS↗