Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLASMA ELECTRODE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

The parameters of electron cyclotron resonance/radio-frequency hybrid hydrogen plasma adjusted by substrate arrangements

Hybrid hydrogen plasma was formed by biasing 13.56 MHz radio-frequency (rf) power on a substrate immersed in 2.45 GHz microwave electron cyclotron resonance (ECR) plasma. The influences of the substrate configuration on plasma characteristics were investigated. With increasing rf self-bias voltage, electron temperature, T{sub e}, increases obviously in the case of the single-electrode substrate, whereas a slight change in T{sub e} was observed with the double-electrode substrate condition. Electron density rises almost with a same magnitude under both two substrate conditions. It exhibited that electron energy and density in ECR-rf hybrid mode could be adjusted independently by controlling rf discharge with favorable substrate configurations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study on the characteristics of a two gap capillary discharge

The paper presents a new two-gap capillary (TGC) discharge structure. The prominent innovation is the introduction of the middle electrode, which divides the capillary into the trigger gap and the main gap. The discharge circuit of the TGC comprises the trigger circuit and the main circuit. The two circuits are used for the pre-ionization of the trigger gap and providing energy of 450 J for the main gap arc discharging, respectively. When the discharge initiates, the trigger gap is pre-ionized under high voltage pulse produced by trigger circuit, and meanwhile, the weakly ionized plasma is generated. The main circuit then maintains the expansion of the plasma, which is called soft capillary discharge. Afterwards, the main gap is shorted and discharges under a relatively low voltage. With the optimization of the circuit parameter, both the energy deposition ratio in main gap and the degree of plasma ionization are enhanced. The efficiency of the energy deposition is almost twice higher compared with that of the conventional capillary structure. The life performance test indicates that the erosion of the middle electrode and the trigger gap carbonization are the key factors that limit the life performance of the TGC.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gas breakdown mechanism in pulse-modulated asymmetric ratio frequency dielectric barrier discharges

The gas breakdown mechanisms, especially the roles of metastable species in atmospheric pressure pulse-modulated ratio frequency barrier discharges with co-axial cylindrical electrodes, were studied numerically using a one dimensional self-consistent fluid model. Simulation results showed that in low duty cycle cases, the electrons generated from the channels associated with metastable species played a more important role in initializing next breakdown than the direct ionization of helium atoms of electronic grounded states by electron-impact. In order to quantitatively evaluate the contribution to the discharge by the metastables, we defined a “characteristic time” and examined how the value varied with the gap distance and the electrode asymmetry. The results indicated that the lifetime of the metastable species (including He*and He{sub 2}{sup *}) was much longer than that of the pulse-on period and as effective sources of producing electrons they lasted over a period up to millisecond. When the ratio of the outer radius to the inner radius of the cylindrical electrodes was far bigger than one, it was found that the metastables distributed mainly in a cylindrical region around the inner electrode. When the ratio decreased as the inner electrode moved outward, the density of metastables in the discharge region near the outer electrode became gradually noticeable. As the discharging gap continued to decrease, the two hill-shaped distributions gradually merged to one big hill. When the discharge spacing was fixed, asymmetric electrodes facilitated the discharge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pulsed photoemission induced plasma breakdown

Abstract This article characterises the effects of cathode photoemission leading to electrical discharges in an argon gas. We perform breakdown experiments under pulsed laser illumination of a flat cathode and observe Townsend to glow discharge transitions. The breakdown process is recorded by high-speed imaging, and time-dependent voltage and current across the electrode gap are measured for different reduced electric fields and laser intensities. We employ a 0D transient discharge model to interpret the experimental measurements. The fitted values of transferred photoelectron charge are compared with calculations from a quantum model of photoemission. The breakdown voltage is found to be lower with photoemission than without. When the applied voltage is insufficient for ion-induced secondary electron emission to sustain the plasma, laser driven photoemission can still create a breakdown where a sheath (i.e. a region near the electrode surfaces consisting of positive ions and neutrals) is formed. This photoemission induced plasma persists and decays on a much longer time scale ( ∼ 10 s μ s) than the laser pulse length ( 30 ps). The effects of different applied voltages and laser energies on the breakdown voltage and current waveforms are investigated. The discharge model can accurately predict the measured breakdown voltage curves, despite the existence of discrepancy in quantitatively describing the transient discharge current and voltage waveforms.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements of Ion Energy and Ion Flux Distributions in Inductively Coupled Plasmas in CF4/O2/Ar Mixtures

We report mass spectrometric studies of energy distributions and absolute concentrations of ions generated in CF4/O2/Ar inductively coupled rf plasmas. The ions were collected through a 100 mm orifice in the grounded and water cooled lower electrode in a GEC cell configuration. The measurements were made at gas pressures in the 10-50 mTorr range and rf coil power in the 100-300 W range. The observed ions are CF3(+), CF2(+), CF(+), C(+), F(+), COF(+), CO(+), O2(+), and O(+). The relative abundance of these ions varies with pressure and rf power. The energy distribution and absolute concentrations are correlated with electron number density and floating plasma potential measured by a compensated Langmuir probe.

Rao, M. V. V. S.↗

Impact of Xe partial pressure on the production of excimer vacuum ultraviolet emission for plasma display panels

In this work, the effect of the Xe partial pressure on the excimer vacuum ultraviolet (VUV) emission intensity of the plasma display panels is investigated, both by measuring the spectral emission directly and by two-dimensional simulations. Experimentally, we find that at the high Xe partial pressure levels, there is an supra-linear increase of excimer VUV radiation and that determines the strong increase of luminance at the high pressures and high voltage. Due to the increase of the luminance and the almost unchanged discharge current, the luminous efficacy strongly increases with the Xe partial pressure. In addition, we also investigated the dynamics of the VUV generation, by measuring the decay time of the excimer VUV light as a function of the gas pressure. It is found that the decay time decreases with the increase of gas pressure. The spatial characteristics of the excimer VUV emission are also discussed. Different from the Ne and near-infrared emission, the excimer VUV emission is generated near the surface of the electrodes and increases uniformly on both sides of the anode and cathode (i.e., the bulk plasma region). Most importantly, it is found that the VUV production occurs during the afterglow period, while it is almost zero at the moment of the discharge itself. From the simulations, it can be seen that the Xe{sub 2}*({sup 3}{Sigma}{sub u}{sup +}) excimer species, which are generated from Xe*(1s{sub 5}), play a dominant role in the excimer VUV emission output at the high Xe partial pressure. The two-dimensional simulations also show that the strong increase of Xe excimer excitation states in the case of high pressure is mainly the result of the high conversion efficiency of the Xe excimer states, especially in the afterglow period. Due to the high conversion efficiency of Xe excitation species to Xe excimer species by the high collision rate in the case of high pressure, there is a strong increase of excimer VUV production, especially from the cathode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gas temperature and electron density profiles in an argon dc microdischarge measured by optical emission spectroscopy

Optical emisssion spectroscopy was employed to study a high pressure (100 s of Torr), slot-type (600 {mu}m interelectrode gap), argon dc microdischarge, with added traces of nitrogen. Spatially resolved gas temperature profiles were obtained by analyzing rovibrational bands of the N{sub 2} first positive system. The gas temperature peaked near the cathode and increased with current. The contribution of Stark broadening to the hydrogen H{sub {beta}} emission lineshape was used to extract the electron density. The axial distribution of electron density as well as visual observation revealed that the microdischarge positive column was highly constricted. The electron density near the sheath edge increased with both pressure and current.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Determination of dust grain charge and screening lengths in the plasma sheath by means of a controlled cluster rotation

Dusty plasma experiments with flat dust clusters are often performed in the boundary sheath of radio frequency discharges at typical gas pressures of 1-100 Pa. The interaction of the dust grains is usually assumed to be of the Yukawa type, which is determined by the particle charge and the screening length. For the experimental determination of these quantities we present a method that does not require prior knowledge of the plasma parameters. The method is based on the application of centrifugal forces by means of a rotating electrode method (REM). The results are critically compared with an analysis of thermally excited normal modes, which can be studied at pressures below 10 Pa. The REM has a wider range of applicability that can be extended to 100 Pa.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Filling the vacuum chamber of a technological system with homogeneous plasma using a stationary glow discharge

Experimental study of a glow discharge with electrostatic confinement of electrons is carried out in the vacuum chamber volume V {approx} 0.12 m{sup 3} of a technological system 'Bulat-6' in argon pressure range 0.005-5 Pa. The chamber is used as a hollow cathode of the discharge with the inner surface area S {approx} 1.5 m{sup 2}. It is equipped with two feedthroughs, which make it possible to immerse in the discharge plasma interchangeable anodes with surface area S{sub a} ranging from {approx}0.001 to {approx}0.1 m{sup 2}, as well as floating electrodes isolated from both the chamber and the anode. Dependences of the cathode fall U{sub c} = 0.4-3 kV on the pressure p at a constant discharge current in the range I = 0.2-2 A proved that aperture of the electron escape out of the electrostatic trap is equal to the sum S{sub o} = S{sub a} + S{sub f} of the anode surface S{sub a} and the floating electrode surface S{sub f}. The sum S{sub o} defines the lower limit p{sub o} of the pressure range, in which U{sub c} is independent of p. At p < p{sub o} the cathode fall U{sub c} grows up dramatically, when the pressure decreases, and the pressure p tends to the limit p{sup ex}, which is in fact the discharge extinction pressure. At p {approx} p{sup ex} electrons emitted by the cathode and the first generation of fast electrons produced in the cathode sheath spend almost all their energy up to 3 keV on heating the anode and the floating electrode up to 600-800{sup o}C and higher. In this case the gas in the chamber is being ionized by the next generations of electrons produced in the cathode sheath, their energy being one order of magnitude lower. When S{sub a} < (2m/M){sup 1/2}S, where m is the electron mass and M is the ion mass, the anode may be additionally heated by plasma electrons accelerated by the anode fall of potential U{sub a} up to 0.5 kV.

74 ATOMIC AND MOLECULAR PHYSICS↗

Schlieren technique applied to the arc temperature measurement in a high energy density cutting torch

Plasma temperature and radial density profiles of the plasma species in a high energy density cutting arc have been obtained by using a quantitative schlieren technique. A Z-type two-mirror schlieren system was used in this research. Due to its great sensibility such technique allows measuring plasma composition and temperature from the arc axis to the surrounding medium by processing the gray-level contrast values of digital schlieren images recorded at the observation plane for a given position of a transverse knife located at the exit focal plane of the system. The technique has provided a good visualization of the plasma flow emerging from the nozzle and its interactions with the surrounding medium and the anode. The obtained temperature values are in good agreement with those values previously obtained by the authors on the same torch using Langmuir probes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Current-driven ion-acoustic and potential-relaxation instabilities excited in plasma plume during electron beam welding

Many papers have sought correlations between the parameters of secondary particles generated above the beam/work piece interaction zone, dynamics of processes in the keyhole, and technological processes. Low- and high-frequency oscillations of the current, collected by plasma have been observed above the welding zone during electron beam welding. Low-frequency oscillations of secondary signals are related to capillary instabilities of the keyhole, however; the physical mechanisms responsible for the high-frequency oscillations (>10 kHz) of the collected current are not fully understood. This paper shows that peak frequencies in the spectra of the collected high-frequency signal are dependent on the reciprocal distance between the welding zone and collector electrode. From the relationship between current harmonics frequency and distance of the collector/welding zone, it can be estimated that the draft velocity of electrons or phase velocity of excited waves is about 1600 m/s. The dispersion relation with the properties of ion-acoustic waves is related to electron temperature 10 000 K, ion temperature 2 400 K and plasma density 10{sup 16} m{sup −3}, which is analogues to the parameters of potential-relaxation instabilities, observed in similar conditions. The estimated critical density of the transported current for creating the anomalous resistance state of plasma is of the order of 3 A·m{sup −2}, i.e. 8 mA for a 3–10 cm{sup 2} collector electrode. Thus, it is assumed that the observed high-frequency oscillations of the current collected by the positive collector electrode are caused by relaxation processes in the plasma plume above the welding zone, and not a direct demonstration of oscillations in the keyhole.

36 MATERIALS SCIENCE↗

Microplasma generating array

A microplasma generator includes first and second conductive resonators disposed on a first surface of a dielectric substrate. The first and second conductive resonators are arranged in line with one another with a gap defined between a first end of each resonator. A ground plane is disposed on a second surface of the dielectric substrate and a second end of each of the first and second resonators is coupled to the ground plane. A power input connector is coupled to the first resonator at a first predetermined distance from the second end chosen as a function of the impedance of the first conductive resonator. A microplasma generating array includes a number of resonators in a dielectric material substrate with one end of each resonator coupled to ground. A micro-plasma is generated at the non-grounded end of each resonator. The substrate includes a ground electrode and the microplasmas are generated between the non-grounded end of the resonator and the ground electrode. The coupling of each resonator to ground may be made through controlled switches in order to turn each resonator off or on and therefore control where and when a microplasma will be created in the array.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the scaling of rf and dc self-bias voltages with pressure in electronegative capacitively coupled plasmas

Higher gas densities and lower diffusion losses at higher operating pressures typically lead to increased charged species densities (and hence flux) for a constant power deposition in capacitively coupled plasmas (CCP). As a result, one would expect that the bias radio-frequency (rf) voltage required to deposit a given power in a CCP reactor decreases with increasing operating pressure. These observations may not hold true in multiple frequency CCPs, commonly used for dielectric etching in microelectronics fabrication, due to nonlinear interactions between the rf sources. Wafer-based measurements of the rf and self-generated direct current (dc) bias voltages in a dual-frequency capacitively coupled electronegative plasma were made, which indicate that the rf and dc voltages vary nonmonotonically with pressure. These experimental results are presented in this paper and a computational plasma model is used to explain the experimental observations for varying 60 MHz and 13 MHz powers in the Ar/CF{sub 4}/CHF{sub 3} plasma over a pressure range of 25 to 400 mTorr. The authors found that while the ion density increases with pressure, the increase is most dominant near the electrode with the high frequency source (60 MHz). The rf and dc bias voltages are ultimately influenced by both charged species density magnitudes and spatial profiles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical analysis of a microwave torch with axial gas injection

The characteristics of a microwave discharge in an argon jet injected axially into a coaxial channel with a shortened inner electrode are numerically analyzed using a self-consistent equilibrium gas-dynamic model. The specific features of the excitation and maintenance of the microwave discharge are determined, and the dependences of the discharge characteristics on the supplied electromagnetic power and gas flow rate are obtained. The calculated results are compared with experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance prediction of electrohydrodynamic thrusters by the perturbation method

In this paper, we present a novel method for analyzing electrohydrodynamic (EHD) thrusters. The method is based on a perturbation technique applied to a set of drift-diffusion equations, similar to the one introduced in our previous study on estimating breakdown voltage. The thrust-to-current ratio is generalized to represent the performance of EHD thrusters. We have compared the thrust-to-current ratio obtained theoretically with that obtained from the proposed method under atmospheric air conditions, and we have obtained good quantitative agreement. Also, we have conducted a numerical simulation in more complex thruster geometries, such as the dual-stage thruster developed by Masuyama and Barrett [Proc. R. Soc. A 469, 20120623 (2013)]. We quantitatively clarify the fact that if the magnitude of a third electrode voltage is low, the effective gap distance shortens, whereas if the magnitude of the third electrode voltage is sufficiently high, the effective gap distance lengthens.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Regularities of Plasma-Immersion Formation of Long-Pulse High-Intensity Titanium Ion Beams

The results of experimental investigations on plasma-immersion formation of ballistically focused beams of low-energy titanium ions with the pulse duration up to 30 μs are presented. The processes of neutralization of the space charge of high-intensity beams upon increasing the ion-current density by a few orders of magnitude during their focusing are addressed. The conditions of preliminary injection of the metal plasma, its parameters, the formation of the beam plasma during residual-gas ionization and secondary and thermionic emissions are shown to be of critical importance for an effective transport of these beams in the equi-potential drift space. It is demonstrated that the use of a disc electrode, preventing the macroparticles from penetrating the region of the ballistic beam focusing, increases the efficiency of long-pulse titanium ion beam transport and simultaneously reduces the probability of instability development.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-power ultraviolet (UV) and vacuum ultraviolet (VUV) lamps with micro-cavity plasma arrays

A plasma lamp includes plates that are approximately parallel, with at least one array of microcavities formed in a surface of at least one plate. When desirable, the plates are separated a fixed distance by spacers with at least one spacer being placed near the plate's edge to form a hermetic seal therewith. A gas makes contact with the microcavity array. Electrodes capable of delivering a time-varying voltage are located on the surface of each plate. At least one electrode is located on an exterior surface of at least one interior plate. Optionally, protective windows may be placed over the electrodes. The application of the time-varying voltage interacts with the gas to form a glow discharge plasma in the microcavities and the fixed volume between the plates (when present). The glow discharge plasma efficiently and uniformly emits UV/VUV radiation over the entire surface of the lamp.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Self-sustained criterion with photoionization for positive dc corona plasmas between coaxial cylinders

The positive dc corona plasmas between coaxial cylinders in air under the application of a self-sustained criterion with photoionization are investigated in this paper. A photon absorption function suitable for cylindrical electrode, which can characterize the total photons within the ionization region, is proposed on the basis of the classic corona onset criteria. Based on the general fluid model with the self-sustained criterion, the role of photoionization in the ionization region is clarified. It is found that the surface electric field keeps constant under a relatively low corona current, while it is slightly weakened with the increase of the corona current. Similar tendencies can be found under different conductor radii and relative air densities. The small change of the surface electric field will become more significant for the electron density distribution as well as the ionization activity under a high corona current, compared with the results under the assumption of a constant surface field. The assumption that the surface electric field remains constant should be corrected with the increase of the corona current when the energetic electrons with a distance from the conductor surface are concerned.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗