Total Cost of Ownership Reduction Using Passive Pre-Chamber Ignition in Natural Gas Engines

Spark plug durability is a factor affecting the total cost of ownership (TCO) of spark-ignited natural gas engines, with some heavy-duty platforms requiring plug replacement after only 750 hours of operation. The high ignition energy demand under lean or diluted conditions accelerates electrode wear, shortening plug life and increasing maintenance frequency. This work evaluates passive pre-chamber (PC) ignition operating at lowered spark energies as a strategy to reduce spark energy requirements and extend plug durability, thereby lowering TCO. Experiments were conducted on a medium-duty Cummins 6.7L ISB engine at 1600 RPM and 50% load under varying exhaust gas recirculation (EGR) dilution levels (0–40%). Two passive pre-chambers with 1.1 mm and 1.6 mm nozzle diameters were compared with conventional spark ignition (SI). SI was operated with a fixed coil dwell of 4 ms (~90 mJ), while the PC configuration was tested across 2–4 ms dwell times (~30–90 mJ). Cylinder pressure analysis revealed that PC ignition sustained stable combustion at significantly lower spark energies than SI, with improved combustion stability at ~30 mJ compared with SI at ~90 mJ. The PC system also extended the dilution tolerance beyond that achievable with SI, while delivering up to ~2% higher indicated thermal efficiency and reducing the COV by nearly 90% at 30% EGR. A TCO analysis was conducted to assess the economic benefit of adopting a passive PC system operating at reduced spark energies compared to SI. It was found that adopting a passive PC system could reduce TCO by approximately $11,000 per engine over a five-year operational period, primarily due to fuel savings, extended spark plug life, and reduced maintenance frequency. These projections were weighed against the additional hardware cost of the pre-chamber, yielding a rapid estimated return on investment of ~300 operating hours. Therefore, this work motivates continued research and development of passive PC technology and its commercial adoption in natural gas engines used in transportation applications.

Dhotre, Akash [University of Minnesota]↗

Wildfire Mitigation Plans in Power Systems: A Literature Review

Some of the deadliest wildfires in the U.S., such as California’s 2018 wildfires, have been ignited by power systems. In an effort to prevent and minimize the ignition of wildfires, or control them if ignited, energy companies have developed wildfire mitigation plans. This paper provides energy companies and power system operators, engineers, researchers, and suppliers an overview of the state-of-the-art studies that address key topics in these wildfire mitigation plans and compares the wildfire mitigation plans of several energy companies. The key topics include grid design and system hardening, asset management and inspection, situational awareness and forecasting, operational response, vegetation management, public safety power shutoff, and risk-spend efficiency. Here this paper also presents a comparison of several energy companies’ decision-making criteria for initiating a public safety power shutoff. Finally, we discuss opportunities for future research studies that could help energy companies prevent wildfire ignitions.

42 ENGINEERING↗

Regional inertia dynamics of U.S. interconnections: An event-based measurement approach

Power grid inertia plays a vital role in frequency stability following large disturbances, yet its distribution across the U.S. grid is highly uneven. While interconnection-wide inertia benchmarks are useful, they can mask regional variability driven by resource mix, network coupling, and geographic separation. This paper extends event-driven inertia estimation to the regional scale using field measurements from the Frequency Monitoring Network (FNET/GridEye). Starting from balancing authority and independent system operator footprints, candidate regions are refined using a composite coherency score that combines frequency-trajectory shape similarity, timing spread, and lead/lag behavior to ensure dynamic consistency. A filtered sliding difference method (FSDM) is then used to construct regional frequency trajectories, detect disturbance onset, and compute robust regional rate-of-change of frequency (RoCoF). Regional, local, and interconnection inertia are estimated by combining RoCoF with event power imbalance, and additional indicators (regional-to-system inertia ratio and inertial-support arrival time) quantify regional-to-interconnection coupling and relative regional contributions. The method is demonstrated on eleven regions across the Eastern Interconnection (EI) and the Western Electricity Coordinating Council (WECC), with the Electric Reliability Council of Texas (ERCOT) used for validation. In ERCOT, estimates compared against energy management system (EMS) values achieve a mean absolute percentage error of 17.94%. WECC exhibits consistently shorter inertial-support arrival times (0.15–0.3 s) than EI (0.7–1.1 s), highlighting contrasting coupling and disturbance-propagation behavior. Overall, the results reveal pronounced spatial heterogeneity in inertia and coupling, underscoring the value of regional monitoring for both operational decision-making and long-term system planning.

Disturbance events↗

On the Verification of Deep Reinforcement Learning Solution for Intelligent Operation of Distribution Grids

Capabilities of deep reinforcement learning (DRL) in obtaining fast decision policies in high dimensional and stochastic environments have led to its extensive use in operational research, including the operation of distribution grids with high penetration of distributed energy resources (DER). However, the feasibility and robustness of DRL solutions are not guaranteed for the system operator, and hence, those solutions may be of limited practical value. This paper proposes an analytical method to find feasibility ellipsoids that represent the range of multi-dimensional system states in which the DRL solution is guaranteed to be feasible. Empirical studies and stochastic sampling determine the ratio of the discovered to the actual feasible space as a function of the sample size. In addition, the performance of logarithmic, linear, and exponential penalization of infeasibility during the DRL training are studied and compared in order to reduce the number of infeasible solutions

Hosseini, Mohammad Mehdi↗

ENVIRONMENTAL REVIEWS AND CASE STUDIES: Addressing the Public Outreach Responsibilities of the National Historic Preservation Act: Argonne National Laboratory’s Box Digital Display Platform

Federal agencies are made responsible for managing the historic properties under their jurisdiction by the National Historic Preservation Act of 1966, as amended. A component of this responsibility is to mitigate the effect of a federal undertaking on historic properties through mitigation often through documentation. Providing public access to this documentation has always been a challenge. To address the issue of public access to mitigation information, personnel from Argonne National Laboratory created the Box Digital Display Platform, a system for communicating information about historic properties to the public. The platform, developed for the US Army Dugway Proving Ground, uses short introductory videos to present a topic but can also incorporate photos, drawings, GIS information, and documents. The system operates from a small, self-contained computer that can be attached to any digital monitor via an HDMI cable. The system relies on web-based software that allows the information to be republished as a touch-screen device application or as a website. The system does not connect to the Internet, and this increases security and eliminates the software maintenance fees associated with websites. The platform is designed to incorporate the products of past documentation to make this information more accessible to the public; specifically those documentations developed using the Historic American Building Survey/ Historic American Engineering Record (HABS/HAER) standards. Argonne National Laboratory’s Box Digital Display Platform can assist federal agencies in complying with the requirements of the National Historic Preservation Act. Environmental Practice 18: 209–213 (2016)

54 ENVIRONMENTAL SCIENCES↗

An Alternative Timing and Synchronization Approach for Situational Awareness and Predictive Analytics

Accurate and synchronized timing information is required by power system operators for controlling the grid infrastructure (relays, Phasor Measurement Units (PMUs), etc.) and determining asset positions. Satellite-based global positioning system (GPS) is the primary source of timing information. However, GPS disruptions today (both intentional and unintentional) can significantly compromise the reliability and security of our electric grids. A robust alternate source for accurate timing is critical to serve both as a deterrent against malicious attacks and as a redundant system in enhancing the resilience against extreme events that could disrupt the GPS network. To achieve this, we rely on the highly accurate, terrestrial atomic clock-based network for alternative timing and synchronization. In this paper, we discuss an experimental setup for an alternative timing approach. The data obtained from this experimental setup is continuously monitored and analyzed using various time deviation metrics. We also use these metrics to compute deviations of our clock with respect to the National Institute of Standards and Technologys (NIST) GPS data. The results obtained from these metric computations are elaborately discussed. Finally, we discuss the integration of the procedures involved, like real-time data ingestion, metric computation, and result visualization, in a novel microservices-based architecture for situational awareness.

Chinthavali, Supriya↗

Real-time Simulation of Coordinated Sub-Transmission Volt-Var Control Tool under High Distributed PV Penetration

With the rapid penetration of intermittent solar photovoltaic (PV) and other distributed energy resources (DER) into the grid, and subsequent changes in power flow patterns in both distribution and sub-transmission, voltage regulation is becoming a major challenge. It is prudent to leverage PV and DER to provide ancillary services to the grid, such as voltage regulation. Recently, a quasi-static, coordinated real-time sub transmission volt-var control algorithm (CReST-VCT) was developed for voltage regulation under high PV penetration by dispatching the reactive power settings of the shunt devices and PV inverters. The algorithm was validated offline, on a quasistatic study. Such quasi-static dispatching algorithms cannot guarantee its performance for highly nonlinear dynamical power systems. In this paper the performance of the algorithm is validated with a real time nonlinear dynamic simulation of a modified IEEE 118 bus system in Opal-RT. The real time simulation is used to emulate the actual system operation, providing a more realistic testing environment for CReST-VCT. The dispatch and control signals are communicated between the power system (Opal solver) and the control center (GAMS solver) in real-time with a MODBUS bridge. The results demonstrate i) system is stable with the new dispatch points ii) significant improvement in system-wide voltage profiles compared to an uncontrolled scenario. Another significant contribution of the work is developing a framework for dispatchable, long duration dynamic simulations that can be leveraged for market/dispatch studies.

CReST-VCT, Opal-RT, Volt/Var Control, renewable in↗

Remedy Application Statistics

The forms and workflow developed were designed to collect additional statistical information not normally available in out of- the-box implementations of the Remedy Action Request System designed by BMC Software. This workflow is used to collect additional information about users accessing the Remedy application, such as operating system and browser type. This information along with frequency of user logins, number of emails sent and received, and overall license usage help provide Remedy Administrators a better overview of the application they support. These custom forms and workflow work heavily with existing out-of-the-box forms in Remedy, and display the collected data to users through the product BMC’s companion product Smart Reporting.

Van Sickle, James↗

CApp v.1.0.0

SAND2021-6830 O Capp is a minimal package manager that supports the dependencies of one application. Its value in comparison to other package managers is its high portability across operating systems and its simplicity and usability for High Performance Computing (HPC) programmers. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Ibanez, Daniel↗

Pipeline Hydrogen Decarbonization and Repurposing Analyzers (P-HyDRAs)

The Pipeline Hydrogen Decarbonization and Repurposing Analyzers (P-HyDRAs) are a set of prototype computational tools for simulating and optimizing midstream natural gas pipeline system operations subject to location and time-dependent hydrogen blending. The models can accurately resolve dynamic gas flows through large-scale pipeline networks using non-ideal gas equations of state. The codes can be used as decision support for planning and design decisions involving intra-day energy flow schedules as well as spatiotemporal economic values of natural gas, hydrogen, and net energy delivered to consumers while ensuring that pipeline hydraulic limitations, gas compressor station constraints, operational factors, and pre-existing shipping contracts are satisfied. The inputs to the codes are a model of the pipeline system as well as time-series data that specify boundary conditions on the network. For optimization, the code module requires price and quantity offers for natural gas and hydrogen and price and quantity bids for energy, which are used as time-dependent constraints in an optimal control problem. The outputs are time-series data that provide a predictive simulation of gas flows, mass fractions, and pressures, or with additional degrees of freedom give an approximately optimal solution for gas injections/withdrawals, compressor settings, and sensitivities to the objective function that provide locational values of energy.

Zlotnik, Anatoly↗

North American Renewables Integration Study (NARIS): Cooperative Research and Development Final Report, CRADA Number CRD-16-00633

The goal of the study is to help inform and assist power system planning entities, electricity system operators, government energy agencies, legislators and regulators to better understand the planning, engineering, operational, and economic implications of integrating large amounts of wind, solar and hydro energy into the Canadian, US and Mexican electrical systems.

14 SOLAR ENERGY↗

Universal Input-Output Model of GFM Functions and Data-Driven Verification Methods

An overarching goal of the UNiversal Interoperability for grid-Forming Inverters (UNIFI) Consortium is to develop vendor agnostic specifications and guidelines that ensure interoperability of gridforming (GFM) inverter-based resources (IBRs) without requiring vendors or system operators to reveal proprietary information. These UNIFI principles and specifications are envisioned to apply to a wide range of technologies and systems. The initial work on the UNIFI principles and specifications has focused on performance requirements and high-level aspirational principles outlined in [1]. Going forward, a key question is how to translate such high-level requirements and principles into rigorous specifications that can be enforced and validated for a wide range of IBRs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Control and optimization system

A system for optimizing a power plant includes a chemical loop having an input for receiving an input parameter (270) and an output for outputting an output parameter (280), a control system operably connected to the chemical loop and having a multiple controller part (230) comprising a model-free controller. The control system receives the output parameter (280), optimizes the input parameter (270) based on the received output parameter (280), and outputs an optimized input parameter (270) to the input of the chemical loop to control a process of the chemical loop in an optimized manner.

20 FOSSIL-FUELED POWER PLANTS↗

Recommended Functionalities for Improving Cybersecurity of Distributed Energy Resources: Preprint

The legacy electric grid is transitioning into a 'present' modern grid due to increasing penetration of intermittent renewable generation at the distribution side, also known as distributed energy resources (DERs). Monitoring and control of such DERs requires extensive data-exchange and bidirectional communication networks. This bidirectional communication paves the way to cyber vulnerabilities and risks for new kinds of cyber-attacks that may have destructive impacts on power system operations. Since IEEE Std. 1547-2018 does not discuss cybersecurity measures for DERs, cybersecurity controls should be developed for securing DER systems at all three levels: device level, communications level, and applications level. This paper discusses the current industry's best practices related to DER cybersecurity and proposes recommended functionalities for improving the cybersecurity posture of DERs. These practical recommended functionalities have been discussed and verified with the industry through a DER cybersecurity working group and are meant to improve the device level security of DERs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Direct versus Facility Centric Load Control for Automated Demand Response

Direct load control (DLC) refers to the scenario where third party entities outside the home or facility are responsible for deciding how and when specific customer loads will be controlled in response to Demand Response (DR) events on the electric grid. Examples of third parties responsible for performing DLC may be Utilities, Independent System Operators (ISO), Aggregators, or third party control companies. DLC can be contrasted with facility centric load control (FCLC) where the decisions for how loads are controlled are made entirely within the facility or enterprise control systems. In FCLC the facility owner has more freedom of choice in how to respond to DR events on the grid. Both approaches are in use today in automation of DR and both will continue to be used in future market segments including industrial, commercial and residential facilities. This paper will present a framework which can be used to differentiate between DLC and FCLC based upon where decisions are made on how specific loads are controlled in response to DR events. This differentiation is then used to compare and contrast the differences between DLC and FCLC to identify the impact each has on:(1)Utility/ISO and third party systems for managing demand response, (2)Facility systems for implementing load control, (3)Communications networks for interacting with the facility and (4)Facility operators and managers. Finally a survey of some of the existing DR related specifications and communications standards is given and their applicability to DLC or FCLC. In general FCLC adds more cost and responsibilities to the facilities whereas DLC represents higher costs and complexity for the Utility/ISO. This difference is primarily due to where the DR Logic is implemented and the consequences that creates. DLC may be more certain than FCLC because it is more predictable - however as more loads have the capability to respond to DR signals, people may prefer to have their own control of end-use loads and FCLC systems. Research is needed to understand the predictability of FCLC which is related to the perceived value of the DR from the facility manager or home owner's perspective.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrity Levels: A New Paradigm for Protecting Computing Systems

As the field of determined and increasingly sophisticated adversaries multiplies, the risk to integrity of deployed computing devices magnifies. Given the ubiquitous connectivity, substantial storage, and accessibility, the increased reliance on computer platforms make them a significant target for attackers. Over the past decade, malware has transitioned from attacking a single program to subverting the operating system (OS) kernel by means of what is commonly known as a rootkit. While computer systems require patches to fix newly discovered vulnerabilities, undiscovered vulnerabilities remain Furthermore, typical solutions utilize mechanisms that operate within the OS. If the OS becomes compromised, these mechanisms may be vulnerable to being disabled or upon detection of the potential compromise, being "shut down" until patched or otherwise mitigated. We propose an innovative approach to designing computer systems that allows the behavior or functionality of the computer system to change based on the integrity of the system. Instead of attempting to prevent or detect all malware attacks, our proposed approach allows possible graceful degradation of functionality according to the security policy specification as anomalies of security concern are detected. We believe this innovative paradigm can determine the "integrity lever of the system. Based on the integrity level, the computer system may behave differently or limit access to data.

97 MATHEMATICS AND COMPUTING↗