Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Noise characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Characterization of feedback resistors for cryogenic applications

Results are presented on the testing of feedback resistors selected for use in the transimpedance amplifiers (TIAs) in the Diffuse Infrared Background Experiment (DIRBE) to be flown on the NASA's Cosmic Background Explorer satellite planned for a launch in 1989. The resistors without encapsulation were found to be reliable as cryogenic circuit elements. Their resistance is sufficiently high (so that their Johnson noise does not dominate amplifier noise at the signal frequency), and they are sufficiently linear; no correction need to be made for signals up to 1.5 V, the 100,000 signal-to-noise level for the DIRBE, which covers most of the signals expected to be seen on the sky.

Lakew, B.↗

Imaging other planetary systems from the moon

This paper studies the problem of using a telescope like the HST, only larger and sensitive to a wider range of wavelengths, to image systems of planets like the solar system around other stars. Both reflected starlight and thermal radiation from the planets are treated. The instrumental effects of aperture diffraction, scattering due to the power spectral density of telescope mirror surface errors, and telescope thermal emission are included. The integration time required to achieve a signal-to-noise ratio is computed at 5 for photon-statistical random errors only, which is a necessary but not sufficient criterion for detection at a confidence level of five standard deviations. A cold telescope on the moon with 16m aperture and the optical quality of HST could detect and characterize planets around nearby stars.

Brown, Robert A.↗

Halbach Magnetic Rotor Development

The NASA John H. Glenn Research Center has a wealth of experience in Halbach array technology through the Fundamental Aeronautics Program. The goals of the program include improving aircraft efficiency, reliability, and safety. The concept of a Halbach magnetically levitated electric aircraft motor will help reduce harmful emissions, reduce the Nation s dependence on fossil fuels, increase efficiency and reliability, reduce maintenance and decrease operating noise levels. Experimental hardware systems were developed in the GRC Engineering Development Division to validate the basic principles described herein and the theoretical work that was performed. A number of Halbach Magnetic rotors have been developed and tested under this program. A separate test hardware setup was developed to characterize each of the rotors. A second hardware setup was developed to test the levitation characteristics of the rotors. Each system focused around a unique Halbach array rotor. Each rotor required original design and fabrication techniques. A 4 in. diameter rotor was developed to test the radial levitation effects for use as a magnetic bearing. To show scalability from the 4 in. rotor, a 1 in. rotor was developed to also test radial levitation effects. The next rotor to be developed was 20 in. in diameter again to show scalability from the 4 in. rotor. An axial rotor was developed to determine the force that could be generated to position the rotor axially while it is rotating. With both radial and axial magnetic bearings, the rotor would be completely suspended magnetically. The purpose of this report is to document the development of a series of Halbach magnetic rotors to be used in testing. The design, fabrication and assembly of the rotors will be discussed as well as the hardware developed to test the rotors.

Gallo, Christopher A.↗

Star Confusion Effect on SIM PlanetQuest Astrometric Performance

SIM PlanetQuest will measure star positions to an accuracy of a few microarcseconds using precise white light fringe measurements. One challenge for SIM observation scenario is "star confusion," where multiple stars are present in the instrument field of view. This is especially relevant for observing dim science targets because the density of number of stars increases rapidly with star magnitude. We study the effect of star confusion on the SIM astrometric performance due to systematic fringe errors caused by the extra photons from the confusion star(s}. Since star confusion from multiple stars may be analyzed as a linear superposition of the effect from single star confusion, we quantify the astrometric errors due to single star confusion surveying over many spectral types, including AOV, FOV, K5III, and MOV, and for various visual magnitude differences. To the leading order, the star confusion effect is characterized by the magnitude difference, spectral difference, and the angular separation between the target and confusion stars.Strategies for dealing with star confusion are presented. For example, since the presence of additional sources in the field of view leads to inconsistent delay estimates from different channels, with sufficient signal to noise ratio, the star confusion can be detected using chi-square statistics of fringe measurements from multiple spectral channels. An interesting result is that the star confusion can be detected even though the interferometer cannot resolve the separation between the target and confusion stars when their spectra are sufficiently different. Other strategies for mitigating the star confusion effect are also discussed.

crowded field↗

BACCHUS Analysis of Weak Lines in APOGEE Spectra (BAWLAS)

Elements with weak and blended spectral features in stellar spectra are challenging to measure and require specialized analysis methods to precisely measure their chemical abundances. In this work, we have created a catalog of approximately 120,000 giants with high signal-to-noise Apache Point Observatory Galactic Evolution Experiment (APOGEE) Data Release 17 (DR17) spectra, for which we explore weak and blended species to measure Na, P, S, V, Cu, Ce, and Nd abundances and 12 C/ 13 C isotopic ratios. We employ an updated version of the Brussels Automatic Code for Characterizing High-accuracy Spectra (BACCHUS) code to derive these abundances using the stellar parameters measured by APOGEE's DR17 Stellar Parameters and Chemical Abundances Pipeline, quality flagging to identify suspect spectral lines, and a prescription for upper limits. Combined, these allow us to provide our BACCHUS Analysis of Weak Lines in APOGEE Spectra catalog of precise chemical abundances for these weak and blended species, which agrees well with the literature and improves upon APOGEE abundances for these elements, some of which are unable to be measured with APOGEE's current, grid-based approach without computationally expensive expansions. This new catalog can be used alongside APOGEE and provides measurements for many scientific applications ranging from nuclear physics to Galactic chemical evolution and Milky Way population studies. To illustrate this we show some examples of uses for this catalog, such as showing that we observe stars with enhanced s-process abundances or that we can use the 12 C/ 13 C ratios to explore extra mixing along the red giant branch.

79 ASTRONOMY AND ASTROPHYSICS↗

MinMap: An imaging spectrometer for high resolution compositional mapping of the Moon

MinMap has been selected by the Lunar Scout program to characterize and map the mineral composition of the Moon. The instrument will be built as a collaborative effort between Brown University, SETS Technology Inc., and Ball Aerospace Corp. MinMap is a visible to near-infrared imaging spectrometer that contains 192 spectral channels from 0.35-2.4 microns with signal to noise greater than 200 and 256 cross-track spatial elements. The spectrometer design has a 6 deg field of view (FOV) and utilizes grating dispersive elements and two dimensional detectors (no moving parts). An 'image cube' of data is produced that contains two dimensions of spatial information and one dimension of spectral information. All spectral channels and cross-track spatial elements are recorded simultaneously with spacecraft motion scanning the second spatial dimension. The high spectral resolution and continuous spectral range of MinMap are designed to measure the diagnostic absorption features of principal lunar minerals and their lithologic mixtures. Since the optical properties of lunar materials change in a regular manner upon exposure to the space environment, this spectral range is also quite sensitive to variations in exposure history (soil maturity). Nominal measurement stragegy is to obtain full global data of the Moon at 180 m/pixel from a 450 km polar orbit during the first month or two of operation. A 100 km orbit is anticipated for the remaining part of a 1 year mission allowing higher resolution data (approx. 80 m/pixel) to be obtained for targeted regions. MinMap exceeds LE x SWG's measurement recommendations and will provide the highest spatial resolution compositional map of lunar rocks and soils currently planned for orbital missions. Since all spectral channels are co-registered and obtained simultaneously, 'image cube' data swaths will be available for analysis almost immediately.

Pieters, C. M.↗

Contrast Measurements of the Microshutter Arrays for the NIRspec

We have been developing programmable microshutter arrays for the Near Infrared Spectrometer (NIRSpec) on the James Webb Space telescope (JWST). These arrays are an enabling technology that allows to turn NIRSpec into a powerful multi-object spectrometer and tremendously increase its efficiency. The arrays are essentially 2D programmable masks that are designed to operate at cryogenic temperatures of JWST. The primary optical characteristic of the microshutter array is a contrast, that is defined as a ratio of the transmitted light intensity through open shutters to the intensity of the transmitted light through the closed shutters. To eliminate the noise and confusion from other sources in the field of view and therefore to improve the detection limit, the contrast provided by the microshutter array should be very high, with the goal of 10,000. The test system that we have developed specifically for the purpose of the high contrast characterization of the microshutter array devices has been used to test several microshutter arrays. It is capable of measuring contrast values of up to 10^5 and therefore can reliably measure contrast values of the arrays that satisfy the requirements. The arrays have been characterized for the contrast ratio and its behavior with temperature and other array operating parameters. The arrays that we have tested meet or exceed the NiRSpec requirements.

Kutyrev, Alexander↗

The Atacama Cosmology Telescope: Sunyaev-Zel'dovich-Selected Galaxy Clusters AT 148 GHz in the 2008 Survey

We report on 23 clusters detected blindly as Sunyaev-Zel'dovich (SZ) decrements in a 148 GHz, 455 deg (exp 2) map of the southern sky made with data from the Atacama Cosmology Telescope 2008 observing season. All SZ detections announced in this work have confirmed optical counterparts. Ten of the clusters are new discoveries. One newly discovered cluster, ACT-CL 10102-4915, with a redshift of 0.75 (photometric), has an SZ decrement comparable to the most massive systems at lower redshifts. Simulations of the cluster recovery method reproduce the sample purity measured by optical follow-up. In particular, for clusters detected with a signal-to-noise ratio greater than six, simulations are consistent with optical follow-up that demonstrated this subsample is 100% pure, The simulations further imply that the total sample is 80% complete for clusters with mass in excess of 6 x 10(exp 14) solar masses referenced to the cluster volume characterized by 500 times the critical density. The Compton gamma-X-ray luminosity mass comparison for the 11 best-detected clusters visually agrees with both self-similar and non-adiabatic, simulation-derived scaling laws,

Marriage, Tobias A.↗

Structural Configuration Analysis of Advanced Flight Vehicle Concepts with Distributed Hybrid-Electric Propulsion

Structural configuration analysis of two advanced aircraft concepts with distributed hybrid-electric propulsion is presented. These concepts are characterized by multiple wing-mounted electric propulsors, which are powered by turbo-generators. Based on lessons learned from previous structural analysis of unconventional concepts, high-fidelity finite element models of the aircraft wing with embedded electric propulsors are developed. Although a hybrid-electric propulsion system has noise and emission benefits, it also adds electrical power system weights. Hence, efficient structural integration of the wing and propulsors is investigated for design improvement, structural analysis, and weight reduction. Wing structural weights of the two designs are compared with a baseline conventional transport aircraft wing for benefit assessment. In one design, the wing structural weight reduction partially compensates for the additional weight associated with the distributed electric propulsion system.

Mukhopadhyay, Vivek↗

ExCALiBR: An Instrument for Uncovering the Origin of the Moon’s Organics.

Lipids are organic molecules of great astrobiological interest for future NASA missions to the Moon, Mars and Icy Worlds. Lipids are essential for life as we know it, and likely also required for putative extraterrestrial organisms. These robust organics can be synthesized abiotically and survive for long periods of geological time. Laboratory characterization techniques are well established but are laborious, operator dependent, and require large volumes of consumables, precluding in situ analysis. We are developing an autonomous, miniaturized fluidic system, integrating lab techniques for lipid analysis while minimizing rea-gent volumes and concentrating organics for analysis, thereby increasing signal-to-noise ratios by orders of magnitude. This system, the Extractor for Chemical Analysis of Lipid Biomarkers in Regolith (ExCALiBR), will enable future organic surveys by extracting and concentrating lipids from approximately 50 grams of regolith using a fluidic and microfluidic sample processor made of materials compatible with non-aqueous solvents required for extraction. ExCAL-iBR can be deployed on a lander or used on a crewed mission.

M B Wilhelm↗

Charge collection efficiency in back-illuminated Charge-Coupled Devices

Low noise CCDs fully-depleted up to 675 micrometers have been identified as a unique tool for Dark Matter searches and low energy neutrino physics. The charge collection efficiency (CCE) for these detectors is a critical parameter for the performance of future experiments. We present here a new technique to characterize CCE in back-illuminated CCDs based on soft X-rays. This technique is used to characterize two different detector designs. The results demonstrate the importance of the backside processing for detection near threshold, showing that a recombination layer of a few microns significantly distorts the low energy spectrum. The studies demonstrate that the region of partial charge collection can be reduced to less than 1 micrometer thickness with adequate backside processing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A 1.2-V 6-GHz Dual-Path Charge-Pump PLL Frequency Synthesizer for Quantum Control and Readout in CMOS 65-nm Process

This paper presents a low jitter dual-path chargepump phase locked loop (PLL) synthesizer in a CMOS 65-nm process for quantum readout applications. The PLL incorporates a programmable dual chargepump and a loop filter with both proportional and integral paths that can be driven independently providing flexible control of the loop bandwidth to achieve low jitter performance. The design is implemented at 300 K and critical blocks like voltage-controlled oscillator (VCO) and chargepump (CP) are analyzed at 77 K based on the characterized results. The LC-VCO is realized with the class-C NMOS only architecture with 5-bit coarse control and quadrature signals are generated with poly phase filter. The VCO is designed with the tuning range of 1 GHz around the center frequency of 6 GHz with Phase Noise of -123 dBc/Hz and -132 dBc/Hz at 1MHz offset at 300 K and 77 K temperature. The simulated PLL rms jitter is 125 fs at 6 GHz with a power consumption of 8 mW at the 1.2 V power supply.

47 OTHER INSTRUMENTATION↗

Realization of a gas puff imaging system on the Wendelstein 7-X stellarator

A system for studying the spatiotemporal dynamics of fluctuations in the boundary of the W7-X plasma using the “Gas-Puff Imaging” (GPI) technique has been designed, constructed, installed, and operated. This GPI system addresses a number of challenges specific to long-pulse superconducting devices, such as W7-X, including the long distance between the plasma and the vacuum vessel wall, the long distance between the plasma and diagnostic ports, the range of last closed flux surface (LCFS) locations for different magnetic configurations in W7-X, and management of heat loads on the system’s plasma-facing components. The system features a pair of “converging–diverging” nozzles for partially collimating the gas puffed locally ≈135 mm radially outboard of the plasma boundary, a pop-up turning mirror for viewing the gas puff emission from the side (which also acts as a shutter for the re-entrant vacuum window), and a high-throughput optical system that collects visible emission resulting from the interaction between the puffed gas and the plasma and directs it along a water-cooled re-entrant tube directly onto the 8 × 16 pixel detector array of the fast camera. The DEGAS 2 neutral code was used to simulate the Hα (656 nm) and HeI (587 nm) line emission expected from well-characterized gas-puffs of H2 and He and excited within typical edge plasma profiles in W7-X, thereby predicting line brightnesses used to reduce the risks associated with system sensitivity and placement of the field of view. Operation of GPI on W7-X shows excellent signal-to-noise ratios (>100 at 2 Mframes/s) over the field of view for minimally perturbing gas puffs. The GPI system provides detailed measurements of the two-dimensional (radial and poloidal) dynamics of plasma fluctuations in the W7-X edge and scrape-off layer and in and around the magnetic islands outside the LCFS that make up the island divertor configuration employed on W7-X.

Instruments & Instrumentation↗

Nuclear Quadrupole Resonance for Substance Detection

This review paper provides a comprehensive overview of recent advances in nuclear quadrupole resonance (NQR) spectroscopy for substance detection, highlighting its principles, methodologies, and applications. The paper elucidates the fundamental physics underlying NQR spectroscopy, emphasizing the interaction between nuclear quadrupole moments and electric field gradients. It explores the various experimental techniques and instrumentation developments that have enabled the sensitive detection and precise characterization of substances containing quadrupolar nuclei. A significant portion of the survey is dedicated to discussing the diverse applications of NQR spectroscopy, including the detection of explosives, drug pharmaceuticals, and material authentication. Furthermore, the survey examines the challenges and limitations associated with NQR spectroscopy, including issues related to signal-to-noise ratio (SNR), temperature dependency, and substance restrictions. Strategies to overcome these challenges are discussed, offering insights into the future directions of NQR spectroscopy research that includes artificial intelligence (AI), internet of things (IoT) integration, incorporating a cloud database for NQR parameter storage, and multi-modal analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Aerodynamic performance of scarf inlets

A scarf inlet is characterized by having a longer lower lip than upper lip leading to both aerodynamic and acoustic advantages. Aerodynamically, a scarf inlet has higher angle of attack capability and is less likely to ingest foreign objects while the aircraft is on the ground. Acoustically, a scarf inlet provides for reduced inlet radiated noise levels below the engine as a result of upward reflection and refraction of inlet radiated noise. Results of a wind tunnel test program are presented which illustrate the aerodynamic performance of two different scarf inlet designs. Based on these results, scarf inlet performance is summarized in a way to illustrate the advantages and limitations of a scarf inlet compared to an axisymmetric inlet.

Abbott, J. M.↗

Aerodynamic performance of scarf inlets

A scarf inlet is characterized by having a longer lower lip than upper lip leading to both aerodynamic and acoustic advantages. Aerodynamically, a scarf inlet has higher angle of attack capability and is less likely to ingest foreign objects while the aircraft is on the ground. Acoustically, a scarf inlet provides for reduced inlet radiated noise levels below the engine as a result of upward reflection and refraction of inlet radiated noise. Results of a wind tunnel test program are presented which illustrate the aerodynamic performance of two different scarf inlet designs. Based on these results, scarf inlet performance is summarized in a way to illustrate the advantages and limitations of a scarf inlet compared to an axisymmetric inlet.

Abbott, J. M.↗

Frozen-Flux Modelling for Epochs 1915 and 1980

The frozen-flux hypothesis for the Earth's liquid core assumes that convective terms dominate diffusive terms in the induction equation governing the behaviour of the magnetic field at the surface of the core. While highly plausible on the basis of estimates of physical parameters, the hypothesis has been questioned. To study this hypothesis, we improve the method which tests the consistency of magnetic observations with the hypothesis by constructing simple, flux-conserving core-field models fitting the data at pairs of epochs. We introduce a new approach that fixes the patch configurations at each of the two epochs before inversion, so that each configuration is consistent with its respective data set but possesses the same patch topology. We expand upon the inversion algorithm, using quadratic programming to maintain the proper flux sign within patches; the modelling calculations are also extended to include data types that depend non-linearly on the model. Every test of a hypothesis depends on the characterization of the observational uncertainties; we undertake a thorough review of this question. For main-field models, the primary source of uncertainty comes from the crustal field. We base our analysis on statistical models of the crustal magnetization, adjusted to bring it into better conformity with our data set. The noise model permits us to take into account the correlations between the measurements and requires that a different weighting be given to horizontal and vertical components. It also indicates that the observations should be fit more closely than has been the practice heretofore. We apply the revised method to Magsat data from 1980 and survey and observatory data from 1915.5, two data sets believed to be particularly difficult to reconcile with the frozen-flux hypothesis. We compute a pair of simple, flux-conserving models that fit the averaged data from each epoch. We therefore conclude that present knowledge of the geomagnetic fields of 1980 and 1915.5 is consistent with the frozen-flux hypothesis.

OBrien, Michael S.↗

Hearing loss in space

BACKGROUND: Temporary and, in some cases, permanent hearing loss has been documented after long-duration spaceflights. METHODS: We examined all existing published data on hearing loss after space missions to characterize the losses. RESULTS: Data from Russian missions suggest that the hearing loss, when it occurs, affects mainly mid to high frequencies and that using hearing protection often might prevent the loss. Several significant questions remain about hearing loss in space. While the hearing loss has been presumed to be noise-induced, no clear link has been established between noise exposure and hearing loss during spaceflight. In one documented case of temporary hearing loss from the Shuttle-Mir program, the pattern of loss was atypical for a noise-induced loss. Continuous noise levels that have been measured on the Mir and previous space stations, while above engineering standards, are not at levels usually associated with hearing loss in ground-based studies (which have usually been limited to 8-10 h exposure periods). Attempts to measure hearing in space using threshold-based audiograms have been unsuccessful in both the American and Russian programs due to noise interference with the measurements. CONCLUSIONS: The existing data highlight the need for reliable monitoring of both hearing and noise in long-duration spaceflight.

manned↗