Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Templates of expected measurement uncertainties for (n, xn) cross sections

A template is provided for evaluating experimental uncertainties for neutron elastic and inelastic scattering cross sections and γ -ray production cross sections from (n, xn) measurements at laboratories with monoenergetic or white neutron sources. A typical range of uncertainties is presented for experiments detecting the scattered neutrons or the resulting de-excitation γ rays based on a survey of available data and input from many experimentalists and theorists with extensive knowledge in the field. Models commonly used to evaluate the resulting cross-sections are also discussed. Suggestions are made regarding what experimental and uncertainty information is needed for data evaluations and should be included when reporting experimental (n, xn) cross sections. Uncertainty values and correlations are recommended if these values cannot be estimated for past data from the literature.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Data Analysis Center for Electromagnetic and Hadronic Interaction. Products of the DAC members

The Data Analysis Center (DAC) of the Center for Nuclear Studies (CNS) at the George Washington University (GW) has made significant progress in its program to enhance and expand the partial-wave (and multipole) analyses of fundamental two- and three-body reactions (such as pion-nucleon, photon-nucleon, and nucleon-nucleon scattering) by maintaining and augmenting the analysis codes and databases associated with these reactions. These efforts provide guidance to experimental groups at the international level, forming an important link between theory and experiment. A renaissance in light hadron spectroscopy is underway as a continuous stream of polarization data issues from existing precision electromagnetic facilities and the coming Jefferson Lab 12 GeV Upgrade. Our principal goals have been focused on supporting the national N* resonance physics program. We have also continued to study topics more generally related to the problems associated with partial-wave analysis. On the Experimental side of the CNS DAC. Its primary goal is the enhancement of the body of data necessary for our analyses of fundamental γ - N reactions. We perform experiments that study the dynamics responsible for the internal structure of the nucleon and its excitations. Our principal focus is on the N* programs at JLab and MAMI. At JLab we study spin-polarization observables using polarized photons, protons and neutrons and yielding charged final states. Similarly at MAMI we study neutral meson photoproduction off polarized protons and neutrons. We use the Crystal Ball and TAPS spectrometers (CBT) to detect photons and neutrons to measure the photoproduction of π0, η, 2π0, π0η, and K0 off the neutron. The CBT program complements our program at JLab, which studies reactions resulting in charged final states. We are also involved in a renewed effort to make neutral pion photoproduction measurements close to threshold at Mainz. In addition to the programs underway, we are contributing to the future by participation in preparations for the coming JLab 12 GeV Upgrade. GW students are involved in tests of the detectors proposed to be used with CLAS12, i.e., for the CentralTime-of-Flight Barrel (CTOF). WJB is heavily involved in the MUSE quest at PSI to solve the Proton Radius Puzzle.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Innovative high pressure gas MEM's based neutron detector for ICF and active SNM detection.

An innovative helium3 high pressure gas detection system, made possible by utilizing Sandia's expertise in Micro-electrical Mechanical fluidic systems, is proposed which appears to have many beneficial performance characteristics with regards to making these neutron measurements in the high bremsstrahlung and electrical noise environments found in High Energy Density Physics experiments and especially on the very high noise environment generated on the fast pulsed power experiments performed here at Sandia. This same system may dramatically improve active WMD and contraband detection as well when employed with ultrafast (10-50 ns) pulsed neutron sources.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detecting nanometer-scale new forces with coherent neutron scattering

Significant effort has been devoted to searching for new fundamental forces of nature. At short length scales (below approximately 10 nm), the strongest experimental constraints come from neutron scattering from individual nuclei in gases. The leading experiments at longer length scales instead measure forces between macroscopic test masses. We propose a hybrid of these two approaches: scattering neutrons off of a target that has spatial structure at nanoscopic length scales. Such structures will give a coherent enhancement to small-angle scattering, where the new force is most significant. This can considerably improve the sensitivity of neutron scattering experiments for new forces in the 0.1–100 nm range. We discuss the backgrounds due to Standard Model interactions and a variety of potential target structures that could be used, estimating the resulting sensitivities. We show that, using only one day of beam time at a modern neutron scattering facility, our proposal has the potential to detect new forces as much as 2 orders of magnitude beyond current laboratory constraints at the appropriate length scales.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Demonstration of neutron identification in neutrino interactions in the MicroBooNE liquid argon time projection chamber

A significant challenge in measurements of neutrino oscillations is reconstructing the incoming neutrino energies. While modern fully-active tracking calorimeters such as liquid argon time projection chambers in principle allow the measurement of all final state particles above some detection threshold, undetected neutrons remain a considerable source of missing energy with little to no data constraining their production rates and kinematics. We present the first demonstration of tagging neutrino-induced neutrons in liquid argon time projection chambers using secondary protons emitted from neutron-argon interactions in the MicroBooNE detector. We describe the method developed to identify neutrino-induced neutrons and demonstrate its performance using neutrons produced in muon-neutrino charged current interactions. The method is validated using a small subset of MicroBooNE’s total dataset. The selection yields a sample with 60% of selected tracks corresponding to neutron-induced secondary protons. At this purity, the integrated efficiency is 8.4% for neutrons that produce a detectable proton.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Si Memory Chip as a Sensitive Neutron Detector

A novel neutron detector is based on semiconductor technology. A boron-containing film is an integral part of the semiconductor device and is in physical contact with the charge-storage medium (CSM). The CSM is a proprietary cell design known as MirrorBit{trademark}, which is different from conventional memory designs such as SRAM or DRAM. The design doubles the resolution and sensitivity in the array. This enables a highly effective detection of the secondary particles, {sup 7}Li and {sup 4}He, produced due to neutron capture by {sup 10}B in the device. Other approaches using semiconductor materials for neutron detection have employed single-diode detectors that require off-system preamplifiers to filter and condition the signal. There are several advantages to this non-volatile detector, one being that it requires no power for detection and retains the signal until reset. Further, this detector, a semiconductor chip, can be seamlessly integrated into other systems. Finally, the semiconductor manufacturing process on which the detector is based will allow for a high-volume and low-cost alternative to current detectors. MirrorBit{trademark} chips were exposed to neutron flux and the signals recorded. Detailed results from this experiment will be described in this presentation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multi-particle inspection using associated particle sources

Disclosed herein are representative embodiments of methods, apparatus, and systems for performing combined neutron and gamma ray radiography. For example, one exemplary system comprises: a neutron source; a set of alpha particle detectors configured to detect alpha particles associated with neutrons generated by the neutron source; neutron detectors positioned to detect at least some of the neutrons generated by the neutron source; a gamma ray source; a set of verification gamma ray detectors configured to detect verification gamma rays associated with gamma rays generated by the gamma ray source; a set of gamma ray detectors configured to detect gamma rays generated by the gamma ray source; and an interrogation region located between the neutron source, the gamma ray source, the neutron detectors, and the gamma ray detectors.

42 ENGINEERING↗

Multiplicity counting using organic scintillators to distinguish neutron sources: An advanced teaching laboratory

In this advanced instructional laboratory, students explore complex detection systems and nondestructive assay techniques used in the field of nuclear physics. After setting up and calibrating a neutron detection system, students carry out timing and energy deposition analyses of radiation signals. Through the timing of prompt fission neutron signals, multiplicity counting is used to carry out a special nuclear material (SNM) nondestructive assay. Our experimental setup is comprised of eight trans-stilbene organic scintillation detectors in a well-counter configuration, and measurements are taken on a spontaneous fission source as well as two (α,n) sources. By comparing each source's measured multiplicity distribution, the resulting measurements of the (α,n) sources can be distinguished from that of the spontaneous fission source. Such comparisons prevent the spoofing, i.e., intentional imitation, of a fission source by an (α,n) neutron source. This instructional laboratory is designed for nuclear engineering and physics students interested in organic scintillators, neutron sources, and nonproliferation radiation measurement techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring the Hubble Constant with Dark Neutron Star–Black Hole Mergers

Abstract Detection of gravitational waves (GWs) from neutron star-black hole (NSBH) standard sirens provides local measurements of the Hubble constant (H 0 ), regardless of the detection of an electromagnetic (EM) counterpart, given that matter effects can be exploited to break the redshift degeneracy of the GW waveforms. The distinctive merger morphology and the high-redshift detectability of tidally disrupted NSBH make them promising candidates for this method. Also, the detection prospects of an EM counterpart for these systems will be limited toz< 0.8 in the optical, in the era of future GW detectors. Using recent constraints on the equation of state of NSs from multi-messenger observations of NICER and LIGO/Virgo/KAGRA, we show the prospects of measuringH 0 solely from GW observation of NSBH systems, achievable by the Einstein telescope (ET) and Cosmic Explorer (CE) detectors. We first analyze individual events to quantify the effect of high-frequency (≥500 Hz) tidal distortions on the inference of NS tidal deformability parameter (Λ) and hence onH 0 . We find that disruptive mergers can constrain Λ up to  ( 60 % ) more precisely than nondisruptive ones. However, this precision is not sufficient to place stringent constraints on theH 0 from individual events. By performing Bayesian analysis on simulated NSBH data (up toN= 100 events, corresponding to a day of observation) in the ET+CE detectors, we find that NSBH systems enable unbiased 4%–13% precision on the estimate ofH 0 (68% credible interval). This is a similar measurement precision found in studies analyzing NSBH mergers with EM counterparts in the LVKC O5 era.

Astronomy & Astrophysics↗

Detection system for high-resolution gamma radiation spectroscopy with neutron time-of-flight filtering

A .gamma.-radiation detection system that includes at least one semiconductor detector such as HPGe-Detector, a position-sensitive .alpha.-Detector, a TOF Controller, and a Digitizer/Integrator. The Digitizer/Integrator starts to process the energy signals of a .gamma.-radiation sent from the HPGe-Detector instantly when the HPGe-Detector detects the .gamma.-radiation. Subsequently, it is determined whether a coincidence exists between the .alpha.-particles and .gamma.-radiation signal, based on a determination of the time-of-flight of neutrons obtained from the .alpha.-Detector and the HPGe-Detector. If it is determined that the time-of-flight falls within a predetermined coincidence window, the Digitizer/Integrator is allowed to continue and complete the energy signal processing. If, however, there is no coincidence, the Digitizer/Integrator is instructed to be clear and reset its operation instantly.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Opportunities for Undergraduate Research in Nuclear Physics

University of Dallas (UD) physics majors are offered a variety of undergraduate research opportunities in nuclear physics through an established program at the University of Kentucky Accelerator Laboratory (UKAL). The 7-MV Model CN Van de Graaff accelerator and the neutron production and detection facilities located there are used by UD students to investigate how neutrons scatter from materials that are important in nuclear energy production and for our basic understanding of how neutrons interact with matter. Recent student projects include modeling of the laboratory using the neutron transport code MCNP to investigate the effectiveness of laboratory shielding, testing the long-term gain stability of C 6 D 6 liquid scintillation detectors, and deducing neutron elastic and inelastic scattering cross sections for 12 C. Finally, results of these student projects are presented that indicate the pit below the scattering area reduces background by as much as 30%; the detectors show no significant gain instabilities; and new insights into existing 12 C neutron inelastic scattering cross-section discrepancies near a neutron energy of 6.0 MeV are obtained.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron spectroscopy with {sup 6}LiF bolometers

A compact and semi-portable neutron detector has been built based on the bolometric technique. Its unique features open new possibilities for the radioprotection survey of fast neutrons at nuclear installations and the investigations of background problems of sensitive neutron scattering instruments. This cryogenic detector, operated at 300-400 mK, consists of a 0.5 g LiF 95%{sup 6}Li enriched crystal read out by a NTD-Ge sensor and is based on the {sup 6}Li(n, {alpha}){sup 3}H neutron capture reaction. It is used to define the energy of neutrons up to 5 MeV. Measurements with {sup 252}Cf source have been performed to determine the energy resolution of the detector. We report the first results obtained with this neutron detector. From developments made in view of the ROSEBUD (Rare Objects SEarch with Bolometers UndergrounD) collaboration we suggest a possible further improvement of the neutron detector by employing a combined heat and light detection. In the case of dark matter experiments, such a detector would allow to monitor the residual fast neutron component.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Differential Die-Away Instrument: Report on Initial Simulations of Spent Fuel Experiment

New Monte Carlo simulations of the differential die-away (DDA) instrument response to the assay of spent and fresh fuel helped to redefine the signal-to-Background ratio and the effects of source neutron tailoring on the system performance. Previously, burst neutrons from the neutron generator together with all neutrons from a fission chain started by a fast fission of 238 U were considered to contribute to active background counts. However, through additional simulations, the magnitude of the 238 U first fission contribution was found to not affect the DDA performance in reconstructing 239 Pu eff . As a result, the newly adopted DDA active background definition considers now any neutrons within a branch of the fission chain that does not include at least one fission event induced by a thermal neutron, before being detected, to be the active background. The active background, consisting thus of neutrons from a fission chain or its individual branches composed entirely of sequence of fast fissions on any fissile or fissionable nuclei, is not expected to change significantly with different fuel assemblies. Additionally, while source tailoring materials surrounding the neutron generator were found to influence and possibly improve the instrument performance, the effect was not substantial.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Basic of Neutron NDA

The objectives of this presentation are to introduce the basic physics of neutron production, interactions and detection; identify the processes that generate neutrons; explain the most common neutron mechanism, spontaneous and induced fission and (a,n) reactions; describe the properties of neutron from different sources; recognize advantages of neutron measurements techniques; recognize common neutrons interactions; explain neutron cross section measurements; describe the fundamental of 3 He detector function and designs; and differentiate between passive and active assay techniques.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Report on Task USA A 0931 (A.252) Implementation of Fast, Front-End Electronics for Improved Low-Dead Time Neutron Counting

The International Atomic Energy Agency's (IAEA) Department of Safeguards is working on the elaboration and implementation of advanced Non-Destructive Assay (NDA) methods, generally known as neutron noise analysis, for the verification of critical and sub-critical cores containing substantial quantities of direct use nuclear material. These verification methods rely on interpreting time properties of the neutron multiplication process, which are to be extracted from measured neutron pulse trains. The interpretations are highly dependent on the quality of the measured data, which is directly related to the capability of an employed neutron detector to resolve very close detection events originating from neutron bursts produced in a highly multiplying medium. Therefore, the application of detectors with minimum dead-time, pile-up, and other distortion effects is required. This report describes the work under Task USA A 0931 (A.252 Implementation of fast, front-end electronics for improved low-dead time neutron counting).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detectors and Data [Slides]

Summary: A gamma-ray spectrum is a histogram of energy deposited in a detector and a ‘fingerprint’ for a particular radionuclide. Shielding can reduce the intensity of peaks in a spectrum, especially at lower energies. HPGe detectors provide the sharpest picture in terms of gamma ray data. Regarding moderation and ³He detectors–too little and neutrons are too fast to be detected; too much and neutrons may get absorbed before reaching the ³He tube.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Long Range Active Detection of HEU Based on Thermal Neutron Multiplication

We report on the results of measurements of proton irradiation on a series of targets at Brookhaven National Laboratory’s (BNL) Alternate Gradient Synchrotron Facility (AGS), in collaboration with LANL and SNL. We examined the prompt radiation environment in the tunnel for the DTRA-sponsored series (E 972), which investigated the penetration of air and subsequent target interaction of 4 GeV proton pulses. Measurements were made by means of an organic scintillator with a 500 MHz bandwidth system. We found that irradiation of a depleted uranium (DU) target resulted in a large gamma-ray signal in the 100-500 µsec time region after the proton flash when the DU was surrounded by polyethylene, but little signal was generated if it was surrounded by boron-loaded polyethylene. Subsequent Monte Carlo (MCNPX) calculations indicated that the source of the signal was consistent with thermal neutron capture in DU. The MCNPX calculations also indicated that if one were to perform the same experiment with a highly enriched uranium (HEU) target there would be a distinctive fast neutron yield in this 100-500 µsec time region from thermal neutron-induced fission. The fast neutrons can be recorded by the same direct current system and differentiated from gamma ray pulses in organic scintillator by pulse shape discrimination.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗