Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Modal Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Blade loss transient dynamics analysis, volume 2. Task 2: Theoretical and analytical development. Task 3: Experimental verification

The component element method was used to develop a transient dynamic analysis computer program which is essentially based on modal synthesis combined with a central, finite difference, numerical integration scheme. The methodology leads to a modular or building-block technique that is amenable to computer programming. To verify the analytical method, turbine engine transient response analysis (TETRA), was applied to two blade-out test vehicles that had been previously instrumented and tested. Comparison of the time dependent test data with those predicted by TETRA led to recommendations for refinement or extension of the analytical method to improve its accuracy and overcome its shortcomings. The development of working equations, their discretization, numerical solution scheme, the modular concept of engine modelling, the program logical structure and some illustrated results are discussed. The blade-loss test vehicles (rig full engine), the type of measured data, and the engine structural model are described.

Gallardo, V. C.↗

In-plane inertial coupling in tuned and severely mistuned bladed disks

A model has been developed and verified for blade-disk-shaft coupling in rotors due to the in-plane rigid body modes of the disk. An analytic model has been developed which couples the in-plane rigid body modes of the disk on an elastic shaft with the blade bending modes. Bench resonance test were carried out on the M.I.T. Compressor Rotor, typical of research rotors with flexible blades and a thick rigid disk. When the rotor was carefully tuned, the structural coupling of the blades by the disks was confined to zero and one nodal diameter modes, whose modal frequencies were greater than the blade cantilever frequency. In the case of the tuned rotor, and in two cases where severe mistuning was intentionally introduced, agreement between the predicted and observed natural frequencies is excellent. The analytic model was then extended to include the effects of constant angular rotation of the disk.

Crawley, E. F.↗

Simulated rotor test apparatus dynamic characteristics in the 80- by 120-foot wind tunnel

A shake test was conducted in the 80 by 120 foot Wind Tunnel at NASA Ames Research Center, using a load frame and dummy weights to simulate the weight of the NASA Rotor Test Apparatus. The simulated hub was excited with broadband random excitation, and accelerometer responses were measured at various locations. The transfer functions (acceleration per unit excitation force as a function of frequency) for each of the accelerometer responses were computed, and the data were analyzed using modal analysis to estimate the model parameters.

Hoque, M. S.↗

The middeck 0-gravity dynamics experiment

The Middeck 0-Gravity Dynamics Experiment (MODE), flown onboard the Shuttle STS-48 Mission, consists of three major elements: the Experiment Support Module, a dynamics test bed providing computer experiment control, analog signal conditioning, power conditioning, an operator interface consisting of a keypad and display, experiment electrical and thermal control, and archival data storage: the Fluid Test Article assembly, used to investigate the dynamics of fluid-structure interaction in 0-gravity; and the Structural Test Article for investigating the open-loop dynamics of structures in 0-gravity. Deployable, erectable, and rotary modules were assembled to form three one- and two-dimensional structures, in which variations in bracing wire and rotary joint preload could be introduced. Change in linear modal parameters as well as the change in nonlinear nature of the response is examined. Trends in modal parameters are presented as a function of force amplitude, joint preload, and ambient gravity. An experimental study of the lateral slosh behavior of contained fluids is also presented. A comparison of the measured earth and space results identifies and highlights the effects of gravity on the linear and nonlinear slosh behavior of these fluids.

Crawley, Edward F.↗

Simulation and testing of digital control on a flexible beam

Large space structures are expected to have control problems due to low stiffness and damping, and control laws for these structures must deal with shape and configuration control as well as attitude and orbit maintenance. In general, these control tasks must be accomplished without adversely interacting with the lightly damped and low frequency vibration modes of the structure. Modal control schemes have been proposed to deal with these problems. A discrete time parameter adaptive control scheme which uses modal control has been proposed by Montgomery and Johnson (1978). In the present investigation the method considered by Montgomery and Johnson is applied to a homogeneous free-free beam in both numerical simulation and laboratory experimentation. Mathematical modeling of the beam is treated in a manner expedient for digital simulation and control implementation.

Williams, J. P.↗

Deployment of a Full-Scope Commercial Nuclear Power Plant Control Room Simulator at the Idaho National Laboratory

The INL operates the HSSL to conduct research in the design and evaluation of advanced reactor control rooms, integration of intelligent support systems to assist operators, development and assessment of advanced human performance models, and visualizations to assess advanced operational concepts across various infrastructures. This advanced facility consists of a reconfigurable simulator and a virtual reality capability (known as the Computer-Aided Virtual Environment (CAVE)) (Figure 2). It supports human factors research, including human-in-the-loop performance, HSI, and analog and digital hybrid control displays. It can be applied to the development and evaluation of control systems and displays for complex systems such as existing and advanced NPP control rooms, command and control systems, and advance emergency operations centers. The HSSL incorporates a reconfigurable control room simulator, which is currently housed in the Center for Advanced Energy Studies (CAES), a joint venture of the DOE and the Idaho University System. The simulator is a platform- and plant-neutral environment intended for full-scope and part-task testing of operator performance in various control room configurations. The simulator is not limited to a particular plant or even simulator architecture. It can support engineering simulator platforms from multiple vendors using digital interfaces. Due to its ability to be reconfigured, it is possible to switch the HSI - not just to digital panels but also to different control modalities such as those using greater plant automation or intelligent alarm filtering. The simulator currently includes three operator workstations, each capable of driving up to eight 30-inch monitors. The size and number of monitors varies depending on the particular front-end simulator deployed for a simulator study. These operator workstations would typically be used for the shift supervisor or senior reactor operator, reactor operator, and assistant reactor operator in current US NPPs. In addition to the three workstations, information can be shared between the workstations and further displayed on a large-screen overview display or a panel mimic. An 82-inch high-definition display is commonly used for the overview display.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Turbulence excited frequency domain damping measurement and truncation effects

Existing frequency domain modal frequency and damping analysis methods are discussed. The effects of truncation in the Laplace and Fourier transform data analysis methods are described. Methods for eliminating truncation errors from measured damping are presented. Implications of truncation effects in fast Fourier transform analysis are discussed. Limited comparison with test data is presented.

Soovere, J.↗

Performance characteristics of high-conductivity channel electron multipliers

The paper describes a new type of continuous channel multiplier (CEM) fabricated from a low-resistance glass to produce a high-conductivity channel section and thereby obtain a high count-rate capability. The flat-cone cathode configuration of the CEM is specifically designed for the detection of astigmatic exit images from grazing-incidence spectrometers at the optimum angle of illumination for high detection efficiencies at XUV wavelengths. Typical operating voltages are in the range of 2500-2900 V with stable counting plateau slopes in the range 3-6% per 100-V increment. The modal gain at 2800 V was typically in the range (50-80) million. The modal gain falls off at count rates in excess of about 20,000 per sec. The detection efficiency remains essentially constant to count rates in excess of 2 million per sec. Higher detection efficiencies (better than 20%) are obtained by coating the CEM with MgF2. In life tests of coated CEMs, no measurable change in detection efficiency was measured to a total accumulated signal of 2 times 10 to the 11th power counts.

Timothy, J. G.↗

Effects of Replacing Treadmill Running with Alternative Exercise Countermeasures During Long-Duration Spaceflight

INTRODUCTION: Current exercise countermeasures on the International Space Station (ISS) include treadmill running, cycle ergometry, and resistive exercise, which are used to protect crewmember health and performance during long-duration spaceflight. However, exploration vehicles for Artemis and beyond will have volume and power restrictions, requiring exercise hardware to have a smaller footprint and use fewer resources. Thus, recent efforts have focused on developing exercise devices (such as the European Enhanced Exploration Exercise Device [E4D]) that provide both aerobic and resistive training on one platform without including a treadmill. It is critical to validate the efficacy of exploration-focused exercise modalities to preserve muscle strength, aerobic fitness, bone density, and sensorimotor performance. Thus, the aim of this study is to determine the physiological effects of spaceflight that occur with nominal ISS exercise prescriptions compared to exploration-forward exercise modalities to determine if a treadmill is required to maintain current levels of protection during long-duration missions. METHODS: Crewmembers will be assigned to one of three groups: 1) Control Group (n ≥ 40), who will partake in nominal exercise on the ISS, including running on the Treadmill with Vibration Isolation and Stabilization 2 (T2), ergometry on the Cycle Ergometer with Vibration Isolation and Stabilization (CEVIS) device, and strength training on the Advanced Resistive Exercise Device (ARED); 2) Active Group 1, who will partake in CEVIS and ARED exercise only (n = 8); and 3) Active Group 2, who will partake in aerobic and resistive exercise on the E4D only (n = 8). For Active Group 1, nominal aerobic exercise on T2 will be replaced with corresponding exercise on CEVIS. For Active Group 2, a dedicated exercise prescription will be designed to maximize the capabilities of the E4D to include resistive exercise, cycle ergometry, rowing, and rope pulling. Crewmembers in both active groups will not be permitted to perform treadmill exercise. Health and performance markers including bone mineral density (dual-energy x-ray absorptiometry [DXA]), body composition (DXA), cardiovascular fitness (cycle VO2peak), muscle strength and endurance (isometric/isokinetic testing, power endurance testing), sensorimotor performance (sit-to-stand, obstacle course), postural control (computerized dynamic posturography), and blood and urine biochemical markers of bone metabolism will be assessed before, during, and following spaceflight. RESULTS: Thirteen subjects (3 Active [CEVIS + ARED], 10 Control) have been recruited for this study. Data collection is currently in progress. CONCLUSIONS: This study will assess the efficacy of exploration exercise modalities, including the effects of removing the treadmill exercise capability or of exclusively using the E4D, compared to nominal ISS exercise across an entire mission on bone, muscle, aerobic, and sensorimotor health and performance. Findings from this study will help provide a recommendation on whether these exploration exercise modalities can sufficiently protect against physiological deconditioning during spaceflight or whether a treadmill may be required to maintain current levels of protection during future exploration class spaceflight missions.

A.N. Varanoske↗

Effects of Replacing Treadmill Running with Alternative Exercise Countermeasures During Long-Duration Spaceflight

INTRODUCTION: Current exercise countermeasures on the International Space Station (ISS) include treadmill running, cycle ergometry, and resistive exercise, which are used to protect crewmember health and performance during long-duration spaceflight. However, exploration vehicles for Artemis and beyond will have volume and power restrictions, requiring exercise hardware to have a smaller footprint and use fewer resources. Thus, recent efforts have focused on developing exercise devices (such as the European Enhanced Exploration Exercise Device [E4D]) that provide both aerobic and resistive training on one platform without including a treadmill. It is critical to validate the efficacy of exploration-focused exercise modalities to preserve muscle strength, aerobic fitness, bone density, and sensorimotor performance. Thus, the aim of this study is to determine the physiological effects of spaceflight that occur with nominal ISS exercise prescriptions compared to exploration-forward exercise modalities to determine if a treadmill is required to maintain current levels of protection during long-duration missions. METHODS: Crewmembers will be assigned to one of three groups: 1) Control Group (n ≥ 40), who will partake in nominal exercise on the ISS, including running on the Treadmill with Vibration Isolation and Stabilization 2 (T2), ergometry on the Cycle Ergometer with Vibration Isolation and Stabilization (CEVIS) device, and strength training on the Advanced Resistive Exercise Device (ARED); 2) Active Group 1, who will partake in CEVIS and ARED exercise only (n = 8); and 3) Active Group 2, who will partake in aerobic and resistive exercise on the E4D only (n = 8). For Active Group 1, nominal aerobic exercise on T2 will be replaced with corresponding exercise on CEVIS. For Active Group 2, a dedicated exercise prescription will be designed to maximize the capabilities of the E4D to include resistive exercise, cycle ergometry, rowing, and rope pulling. Crewmembers in both active groups will not be permitted to perform treadmill exercise. Health and performance markers including bone mineral density (dual-energy x-ray absorptiometry [DXA]), body composition (DXA), cardiovascular fitness (cycle VO2peak), muscle strength and endurance (isometric/isokinetic testing, power endurance testing), sensorimotor performance (sit-to-stand, obstacle course), postural control (computerized dynamic posturography), and blood and urine biochemical markers of bone metabolism will be assessed before, during, and following spaceflight. RESULTS: Thirteen subjects (3 Active [CEVIS + ARED], 10 Control) have been recruited for this study. Data collection is currently in progress. CONCLUSIONS: This study will assess the efficacy of exploration exercise modalities, including the effects of removing the treadmill exercise capability or of exclusively using the E4D, compared to nominal ISS exercise across an entire mission on bone, muscle, aerobic, and sensorimotor health and performance. Findings from this study will help provide a recommendation on whether these exploration exercise modalities can sufficiently protect against physiological deconditioning during spaceflight or whether a treadmill may be required to maintain current levels of protection during future exploration class spaceflight missions.

A.N. Varanoske↗

Experimental and Numerical Investigation on Vibration of Sandwich Plates with Honeycomb Cores Based on Radial Basis Function

The vibration characteristic of the sandwich plate with a honeycomb core was investigated by experimental measurements and numerical calculation based on radial basis function (RBF). RBF method was used not only in the meshless approach but also in the post-processing of the experimental data. During the experiment, amplitude-fluctuation electronic speckle pattern interferometry was applied to access the resonant frequencies and the corresponding vibration mode shapes simultaneously. Then RBF method was used to improve the quality of patterns and reconstruct the out-of-plane vibration amplitude after fringe analysis. As for numerical calculation, the modal parameters were numerically predicted using the first-order shear deformation theory. The computation approach was based on collocation with multi-quadric radial basis function. To understand the influence of the thickness of face sheet on dynamic behaviors, three types of specimens with different thickness were tested and analyzed. Of particular interest was that the vibration modes show veering due to the thickness increment. Furthermore, the numerical predicted results were compared with the experimental measurements for the first five modes. They are in good agreement with each other for resonant frequencies, mode shapes and relative out-of-plane amplitudes.

36 MATERIALS SCIENCE↗

Monitoring of mechanical changes in a pipe assembly with complex geometry using multi-mode acoustic signals

Guided wave ultrasonic testing has been widely used for nondestructive and long-range evaluation of diverse mechanical structures, such as pipes and plates. In general, a large number of guided wave modes exist even in the simplest geometries, and they exhibit highly dispersive characteristics. Thus, sophisticated excitation methods and elaborate modal analyses need to be implemented to excite, acquire, and process well-defined pure modes as part of such a measurement method. If the interrogated structure has complex geometry, for example, with cross-sectional variations or multiple joints, the utilization of pure modes becomes significantly more difficult. To overcome this difficulty, this paper proposes the use of multi-mode, multi-frequency guided waves for long-range inspection of structures with arbitrarily complex geometries. Furthermore, using broadband chirp signals and multi-mode time–frequency analysis in a prototypical complex pipe assembly that includes multiple pipe diameters, elbows, and flange connections, we experimentally show sensitive detection of mechanical changes (both material addition and loss). In addition, we demonstrate that the complexity of the structure can be modeled in the digital domain with sufficient detail to allow accurate numerical simulation of the acoustic response using this method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radiographic Imaging and Tomography

Radiographic imaging and tomography (RadIT) come in many flavors such as X-ray imaging and tomography (IT), proton IT, neutron IT, muon IT, neutrino IT, etc. We identify five RadIT themes: Physics, Sources, Detectors, Methods, and Data Science, which are integral parts of image interpretation and three-dimensional (3D) tomographic reconstruction. Traditionally, RadIT have been driven by medicine, non-destructive testing, material sciences, and security applications. The latest thrusts of growth come from automation, machine vision, additive manufacturing and virtual reality (‘metaverse’). The five RadIT themes parallel their counterparts in optical IT. Synergies among different forms of RadIT and with optical IT motivate further advances towards multi-modal IT and quantum IT.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PhytoOracle: Scalable, modular phenomics data processing pipelines

As phenomics data volume and dimensionality increase due to advancements in sensor technology, there is an urgent need to develop and implement scalable data processing pipelines. Current phenomics data processing pipelines lack modularity, extensibility, and processing distribution across sensor modalities and phenotyping platforms. To address these challenges, we developed PhytoOracle (PO), a suite of modular, scalable pipelines for processing large volumes of field phenomics RGB, thermal, PSII chlorophyll fluorescence 2D images, and 3D point clouds. PhytoOracle aims to ( i ) improve data processing efficiency; ( ii ) provide an extensible, reproducible computing framework; and ( iii ) enable data fusion of multi-modal phenomics data. PhytoOracle integrates open-source distributed computing frameworks for parallel processing on high-performance computing, cloud, and local computing environments. Each pipeline component is available as a standalone container, providing transferability, extensibility, and reproducibility. The PO pipeline extracts and associates individual plant traits across sensor modalities and collection time points, representing a unique multi-system approach to addressing the genotype-phenotype gap. To date, PO supports lettuce and sorghum phenotypic trait extraction, with a goal of widening the range of supported species in the future. At the maximum number of cores tested in this study (1,024 cores), PO processing times were: 235 minutes for 9,270 RGB images (140.7 GB), 235 minutes for 9,270 thermal images (5.4 GB), and 13 minutes for 39,678 PSII images (86.2 GB). These processing times represent end-to-end processing, from raw data to fully processed numerical phenotypic trait data. Repeatability values of 0.39-0.95 (bounding area), 0.81-0.95 (axis-aligned bounding volume), 0.79-0.94 (oriented bounding volume), 0.83-0.95 (plant height), and 0.81-0.95 (number of points) were observed in Field Scanalyzer data. We also show the ability of PO to process drone data with a repeatability of 0.55-0.95 (bounding area).

59 BASIC BIOLOGICAL SCIENCES↗

Aeroelastic stability analyses of two counter rotating propfan designs for a cruise missile model

Aeroelastic stability analyses were performed to insure structural integrity of two counterrotating propfan blade designs for a NAVY/Air Force/NASA cruise missile model wind tunnel test. This analysis predicted if the propfan designs would be flutter free at the operating conditions of the wind tunnel test. Calculated stability results are presented for the two blade designs with rotational speed and Mach number as the parameters. A aeroelastic analysis code ASTROP2 (Aeroelastic Stability and Response of Propulsion Systems - 2 Dimensional Analysis), developed at LeRC, was used in this project. The aeroelastic analysis is a modal method and uses the combination of a finite element structural model and two dimensional steady and unsteady cascade aerodynamic models. This code was developed to analyze single rotation propfans but was modified and applied to counterrotating propfans for the present work. Modifications were made to transform the geometry and rotation of the aft rotor to the same reference frame as the forward rotor, to input a non-uniform inflow into the rotor being analyzed, and to automatically converge to the least stable aeroelastic mode.

Mahajan, Aparajit J.↗

Electrical Resistance of SiC/SiC Ceramic Matrix Composites for Damage Detection and Life-Prediction

Ceramic matrix composites (CMC) are suitable for high temperature structural applications such as turbine airfoils and hypersonic thermal protection systems due to their low density high thermal conductivity. The employment of these materials in such applications is limited by the ability to accurately monitor and predict damage evolution. Current nondestructive methods such as ultrasound, x-ray, and thermal imaging are limited in their ability to quantify small scale, transverse, in-plane, matrix cracks developed over long-time creep and fatigue conditions. CMC is a multifunctional material in which the damage is coupled with the material s electrical resistance, providing the possibility of real-time information about the damage state through monitoring of resistance. Here, resistance measurement of SiC/SiC composites under mechanical load at both room temperature monotonic and high temperature creep conditions, coupled with a modal acoustic emission technique, can relate the effects of temperature, strain, matrix cracks, fiber breaks, and oxidation to the change in electrical resistance. A multiscale model can in turn be developed for life prediction of in-service composites, based on electrical resistance methods. Results of tensile mechanical testing of SiC/SiC composites at room and high temperatures will be discussed. Data relating electrical resistivity to composite constituent content, fiber architecture, temperature, matrix crack formation, and oxidation will be explained, along with progress in modeling such properties.

Smith, Craig↗

Validation of a Manually Oscillating Chair for In-The-Field Assessment of Dynamic Visual Acuity on Crewmembers Within Hours of Returning From Long-Duration Spaceflight

Long-duration spaceflight results in sensorimotor adaptations, which cause functional deficits during gravitational transitions, such as landing on a planetary surface after long-duration microgravity exposure. Both the vestibular system and the central nervous system are affected by gravitational transitions. These systems are responsible for coordinating head and eye movements via the vestibulo-ocular reflex (VOR) and go through an adaptation period upon exposure to microgravity. Consequently, they must also re-adapt to Earth's gravitational environment upon landing. This re-adaptation causes decrements in gaze control and dynamic visual acuity, with crewmembers reporting oscillopsia and blurred vision caused by retinal slip, or the inability to keep an image focused on their retina. This is thought to drive motion sickness symptoms experienced by most crewmembers following landing. Retinal slip can be estimated by dynamic visual acuity (DVA); visual acuity while in motion. Previously, DVA has been assessed in the laboratory where subjects walked at 6.4 km/hr on a motorized treadmill. Using this method, Peters et al. (2011) found that DVA is worsened in astronauts by an average of 0.75 eye-chart lines one day after landing. However, it is believed that re-adaptation occurs quickly and that DVA might be worse immediately upon re-exposure to a gravitational environment. Since many crewmembers are unable to walk safely upon landing, it was necessary to develop a method for replicating the vertical head movements associated with walking. In addition, the use of a chair to imitate the head displacement caused by walking isolates eye-head interactions without allowing for trunk and lower-body compensation, as seen with treadmill walking (Mulavara & Bloomberg 2003). Therefore, a modality for assessing DVA in the field within a few hours of landing was developed. In this study, we validated the ability of a manually operated oscillating chair to reproduce the oscillatory frequency of walking on a treadmill. Healthy non-astronaut subjects (n=14) participated in one test session and completed three static (seated) and three dynamic (walking/oscillated) visual acuity tests. DVA was assessed using a motorized treadmill, an automated oscillating chair, and a manually operated chair, both developed in the Neuroscience Laboratory at JSC. The automated chair was motor-driven and set to oscillate vertically at 2 Hz with a vertical displacement of +/- 5 cm to simulate vertical translation while walking. The manually operated chair was oscillated vertically by a test operator to the beat of a metronome at 120 beats/min (2 Hz) and a vertical displacement of approximately +/- 5 cm. As the subject was oscillated, they were asked to discern the direction gap of Landolt-C optotypes of varying sizes and verbally reported the direction while an operator recorded their response using a gamepad. Subjects were outfitted with accelerometers (sampling rate = 128 Hz) on their head, trunk and lumbar spine. A fast Fourier transform was performed on the vertical trunk acceleration to compare the peak and spread of the distribution of oscillation frequencies for each oscillating condition. The spread of the frequency distribution for the manual chair was not significantly different from either the treadmill or the automated chair. However, all three conditions had similar non-zero standard error values, suggesting a variance in head movement frequency which may affect DVA. The average oscillation frequency of the manual chair (1.85 Hz) was significantly different (α=0.05) from that of treadmill walking (2.24 Hz), but not significantly different from that of the automated chair (1.85 Hz) and all three conditions had small standard errors (SEM = 0.04, 0.06, and 0.08 Hz for manual, treadmill, and automated respectively). This implies that both chairs oscillate at a frequency below that of treadmill walking, but are comparable to each other and reproducible across sessions. Additionally, DVA scores did not vary significantly across conditions. The smaller spread values of the oscillating chairs' frequencies indicated mitigation of variation induced by locomotor strategies, which enables better examination of the issue of VOR adaptation. Furthermore, due to the deconditioned state of crewmembers in the initial hours after landing, it is easier to transport a manual bouncing chair into the field and safer to perform a vision test while seated in a chair versus walking on a treadmill. Therefore, the manually oscillating chair has been deemed to meet and exceed the DVA testing capabilities previously obtained by treadmill walking.

Kreutzberg, G. A.↗