Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Mitigation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Assessment of potential greenhouse gas mitigation from changes to crop root mass and architecture

Reducing (and eventually reversing) the increase in greenhouse gases (GHGs) in the atmosphere due to human activities, and thus reducing the extent and severity of anthropogenic climate change, is one of the great challenges facing humanity. While most of the man-caused increase in GHGs has been due to fossil fuel use, land use (including agriculture) currently accounts for about 25% of total GHG emissions and thus there is a need to include emission reductions from the land use sector as part of an effective climate change mitigation strategy. In addition, analyses included in the recent IPCC 5th Climate Change Assessment report suggests that it may not be possible to achieve large enough emissions reductions in the energy, transport and industrial sectors alone to stabilize GHG concentrations at a level commensurate with a less than 2°C global average temperature increase, without the help of a substantial CO 2 sink (i.e., atmospheric CO 2 removal) from the land use sector. One of the potential carbon sinks that could contribute to this goal is increasing C storage in soil organic matter on managed lands. This report details a preliminary scoping analysis, to assess the potential agricultural area in the US – where appropriate soil, climate and land use conditions exist – to determine the land area on which ‘improved root phenotype’ crops could be deployed and to evaluate the potential long-term soil C storage, given a set of ‘bounding scenarios’ of increased crop root input and/or rooting depth for major crop species (e.g., row crops (corn, sorghum, soybeans), small grains (wheat, barley, oats), and hay and pasture perennial forages). The enhanced root phenotype scenarios assumed 25, 50 and 100% increase in total root C inputs, in combination with five levels of modifying crop root distributions (i.e., no change and four scenarios with increasing downward shift in root distributions). We also analyzed impacts of greater root production on the soil-crop nitrogen balance, from the standpoint of increased need for additional N inputs and consequences for increased N 2 O flux, as well as potential impacts if more and deeper roots contributed to reduced N leaching. In the enhanced root phenotype scenarios, the implicit assumption was that increases in overall plant production could be achieved (e.g., through increased CO 2 assimilation, greater growth efficiency) without reducing the harvested yield – that is, we did not include potential leakage and land substitution effects from potential decreased crop yield in the analysis.

54 ENVIRONMENTAL SCIENCES↗

Improving Department of Energy capabilities for Mitigating Beyond Design Basis Events

The purpose of this Operating Experience (OE) document is to (1) provide results from U.S. Department of Energy (DOE), including the National Nuclear Security Administration, initiatives related to beyond design basis events (BDBEs), and (2) provide direction for enhancing capabilities for mitigating BDBEs at DOE sites

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Underground coal gasification: An overview of groundwater contamination hazards and mitigation strategies

Underground coal gasification is the in situ conversion of coal into an energy-rich product gas. It takes place deep underground, using chemical reactions to consume the coal and grow a cavity. Gas wells, drilled into the coal seam, inject reactant air, oxygen, and/or steam to sustain the reactions. Production wells then extract the product gas. Careful analysis and understanding of likely failure modes will help prevent and minimize impacts. This document provides a general description of the relevant processes, potential failure modes, and practical mitigation strategies. It can guide critical review of project design and operations.

01 COAL, LIGNITE, AND PEAT↗

Self-Healing, Re-adhering, and Corrosion-Mitigating Inorganic Cement Composites for Geothermal Wells at 270°-300°C: Final Report

Under the DOE EERE Geothermal Technologies Office (GTO)-funding project in FY 2016- 2018, the scope of work at Brookhaven National Laboratory (BNL) aimed 1) to conduct the screening of qualified candidates for self-healing cement composites reinforced with microcarbon fiber (MCF), 2) to obtain the fundamental understanding of self-healing mechanism, to develop self-healing aides, 3) to evaluate re-adhering performance of debonded self-healing composites to carbon steel (CS) casing or granite rock formation, 4) to evaluate bond durability of composite/CS joint in acid and thermal shock environments, 5) to assess the corrosion mitigation of CS by composites adhering and re-adhering to CS surfaces, and 6) to investigate the maintenance of pumpability at 85° and 100°C of optimized composite slurry as well as to evaluate self-healing and re-adhering ability of pumpable composite formulation at hydrothermal temperatures, ranging from 270° to 300°C. In this work, three different cementitious material groups, 1) Ordinary Portland Cement (OPC)-based cements, 2) alkali (sodium metasilicate, SMS)-activated cements, and 3) phosphate (sodium hexametaphosphate, SHMP)-bonded cements, were evaluated to meet the following ten material criteria suitable for inorganic cement composites in six different environments, the plain water, alkali carbonate, geo-brine, thermal shock, pH 0.6 H 2 SO 4 /brine, and pH 5.5 scCO 2 /brine.

15 GEOTHERMAL ENERGY↗

Universal Wide-area Damping Control for Mitigating Inter-area Oscillations in Power Systems

The active damping of inter-area oscillations of low frequencies has been successfully demonstrated to improve the dynamic response of the power grid in a satisfactory manner. It also enhances the system stability and reliability as well. The existence of inter-area oscillations has already become one of the key challenges in large-scale interconnected power grids because they are detrimental to the achievement of maximum power transfer and optimal power flow. This project focuses on the development of a universal damping control based on phasor measurements so that it can be easily implemented by a mix of various fast-acting resources to effectively mitigate inter-area oscillations. With the proposed advanced damping control strategies, the power grid stability and reliability can be managed in a much more flexible manner by utilizing different resources that are geographically dispersed in both the transmission and distribution systems. Moreover, higher power transfer capacity can be also achieved.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Wind Turbine Radar Interference Mitigation (WTRIM) Modeling & Simulation Tools Catalog

Wind energy development in the United States has been steadily growing over the past decade. This trend has resulted in the expansion of wind energy into areas that have a good wind resource but may have other deployment barriers being looked at more closely. One such barrier is that of the potential impact that wind turbines pose to radar systems. Wind turbines located within the line-of-sight of radar systems can cause clutter and interference and can result in performance degradation. Mitigation of any interference that wind turbines have on radar systems begins with the understanding of the potential those impacts to radar systems through modeling and simulation. The intent of this document is to catalog and provide the reader with a list of the modeling and simulation capabilities along with enabling databases for wind turbine — radar interference and related issues that are currently in use in various government agencies as well as those tools that are available to the public for free or fee. A brief description of the tool is given along with other pertinent characteristics of the tool including the owner, developers, user, classification, status, and the point-of-contact. This document does not provide an exhaustive description of the tools' capabilities nor does it include tools that were developed privately.

17 WIND ENERGY↗

Vehicle Cybersecurity Threats and Mitigation Approaches

Federal fleet managers and the information technology teams working with them need to understand the threats associated with modern vehicles. As vehicles become safer overall, the dangers change from distracted drivers to privacy intrusion and compromised operation. While fleet managers cannot necessarily change the configurations of manufacturer settings in mass market vehicles, they can influence what protective measures are taken in supplemental equipment or pilot-project vehicles. This report identifies security concerns, mitigation techniques, and procurement language that may be applicable in certain cases.

33 ADVANCED PROPULSION SYSTEMS↗

Abengoa/Acciona Power Plant Hydrogen Mitigation Project (Cooperative Research and Development Final Report, CRADA Number CRD-15-583)

Several Gigawatts (GW) of solar concentrating parabolic trough generating capacity have been installed in the U.S. and internationally in the past five years. Many of these power plants include thermal energy storage, which allows the plants to generate electricity during off-sun hours. The U.S. now has about 1 GW of solar-to-electric generating capacity using concentrating parabolic trough technology. Parabolic trough power plants have a long-standing performance issue relating to the build-up of trace quantities of hydrogen gas in the receiver tubes. Hydrogen is a byproduct of the very slow breakdown of the heat transfer fluid. Accumulation of hydrogen in the receivers causes a loss in the thermal efficiency of the receivers and an overall decrease in the power plant annual electricity output. Since a typical plant contains 50,000 receivers, addressing this issue by individual receiver is not practical. The National Renewable Energy Laboratory (NREL) conceived and developed a method to remove or purge hydrogen from the power plant receivers by removing hydrogen from a single location within the plant. Hydrogen gas is purged from the heat transfer fluid that resides in the power plant expansion tanks. Modeling shows that quantitative removal of hydrogen from the expansion tanks will reverse build-up of hydrogen in the receiver tubes and restore the power plant to its full performance and annual energy output. This method is documented in U.S. Patent 8,568,582, which issued in October 2013. Two companies, Abengoa Solar and Acciona Solar Power, Inc. contacted NREL to discuss solutions to the eventual build-up of hydrogen in their commercial parabolic trough power plants. NREL proposed to implement its method at Acciona's Nevada Solar One (NSO) parabolic trough power plant in Boulder City, Nevada. The first year will consist of laboratory testing at the NREL Energy Systems Integration Facility (ESIF) along with process specification, design, and costing. The second year will be the full-scale implementation of the hydrogen mitigation process at the NSO power plant in Nevada.

14 SOLAR ENERGY↗

Whole-Program Adaptive Error Detection and Mitigation. Final Report

Errors in application state resulting from faults in hardware are an increasing concern on extreme-scale computing systems. Errors that escape detection and lead to silent data corruption are particularly problematic. Detecting errors is an important first step toward fault tolerant program execution. The multi-institutional project addressed a comprehensive approach to error detection and mitigation for scientific applications that combined configurable error detectors, a unified reliability specification, and whole-program detector composition.

97 MATHEMATICS AND COMPUTING↗

Phase I Closeout Report: Invoking Artificial Neural Networks to Measure Insider Threat Mitigation

Researchers from Sandia National Laboratories (Sandia) and the University of Texas at Austin (UT) conducted this study to explore the effectiveness of commercial artificial neural network (ANN) software to improve insider threat detection and mitigation (ITDM). This study hypothesized that ANNs could be "trainee to learn patterns of organizational behaviors, detect off-normal (or anomalous) deviations from these patterns, and alert when certain types, frequencies, or quantities of deviations emerge. The ReconaSense ANN system was installed at UT's Nuclear Engineering Teaching Laboratory (NETL) and collected 13,653 access control data points and 694 intrusion sensor data points over a three-month period. Preliminary analysis of this baseline data demonstrated regularized patterns of life in the facility, and that off-normal behaviors are detectable under certain situations -- even for a facility with anticipated highly non-routine, operational behaviors. Completion of this pilot study demonstrated how the ReconaSense ANN could be used to identify expected operational patterns and detect unexpected anomalous behaviors in support of a data-analytic approach to ITDM. While additional studies are needed to fully understand and characterize this system, the results of this initial study are overall very promising for demonstrating a new framework for ITDM utilizing ANNs and data analysis techniques.

97 MATHEMATICS AND COMPUTING↗

Evaluation of Detritiation Strategies for Mitigating Tritium Releases

Tritium confinement is performed using different barriers to minimize releases to the environment. Primary confinement is usually performed by process piping and components, secondary confinement typically by inerted gloveboxes connected to a continuously operating tritium stripper system. Some facility designs employ tertiary tritium confinement by using process room confinement with a tritium stripper system activated after an accident to further mitigate tritium releases to the environment. Secondary confinement of some tritium systems such as radiation-hardened or shielded-cell enclosures are not easily achieved using designs for inerted glovebox. These enclosures can be challenging to seal for secondary tritium confinement due to heating, ventilation, and air conditioning (HVAC) needs for temperature control, as well as feedthroughs for equipment and instrumentation, are potential pathways for tritium leaks or loses. Additional tritium leak paths can be created in secondary confinement enclosures due to a Design Basis Accident (DBA) seismic event. These new, larger tritium leak rates from the DBA event are usually not part of the stripper system design basis so all tritium released to the secondary confinement enclosure is assumed released to the environment. Detritiation strategies for shielded enclosures and/or gloveboxes with significant leak rates are necessary to minimize off-site radiological dose consequences. To address this, the relationship between the confinement system leak rate and stripper system (recirculating) flow rate was evaluated to meet prescribed maximum allowable environmental tritium emissions from the event. The simple analysis described assumes a constant leak rate from the confinement system (i.e. shielded enclosure or glovebox) while a recirculating stripper system strips tritium from the system– a competition between tritium release and tritium recovery. At a high level, the resulting expression summarizes the relationship between system leak rate (F L ) and stripper flow rate (F S ) relative to allowable tritium release (Q A ) and initial tritium release (Q 0 ): $\frac{F_L}{F_s}$ ≈ $\frac{Q_A}{Q_0}$. This report derives the relationship between these parameters, examines the impact of finite stripping times followed by purging of the stripped volume. The analysis provides example results for up to 30 gram tritium releases: the maximum tritium inventory of a Hazard Category III (Department of Energy) Nuclear Facility. The detritiation model presented represents a high-level analysis of tritium recovery versus losses for “leaky” confinement enclosures such as shielded cells after large tritium releases. Key parameters for doing the analyses are the system leak rate, stripper flow rate, initial tritium release, and allowable tritium release values. The analyses show a proportional decrease in releases with reduction in initial tritium release but a non-linear increase in tritium recovery with increased stripper flow rate or reduced leak-rate. The analyses also apply to glovebox confinement systems which could have significant increases in leak rates after a DBA. The analysis recognizes but does not include tritium absorption followed by re-emission from the walls of the confinement volume – an analysis which could be pursued in future studies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Practices Implemented by DOE Better Plants Program Partners to Mitigate COVID-19

Screening for symptoms, maintaining physical distance, sanitizing surfaces, wearing appropriate face masks, maintaining good personal hygiene, and reconfiguring HVAC air management are the major activities that the DOE BP partners have implemented to mitigate COVID-19. This article shares some specific practices that BP program partners have implemented for these activities. The energy impact of some practices has also been discussed and some rules of thumb have been provided to estimate energy penalties.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Subtask 2.6 – Optimization of Aerosol Mitigation Technology for Postcombustion CO 2 Capture

Growing concerns over the impact of CO 2 emissions from combustion sources on global climate change have prompted numerous research and development projects aimed at developing cost-effective technologies for CO 2 capture. One family of technologies being demonstrated at pilot and full scale globally is postcombustion CO 2 capture (PCCC) systems that employ amine-based solvents. The captured CO 2 can be compressed and permanently stored underground or used for enhanced oil recovery (EOR). The proximity of North Dakota’s lignite-fired fleet of power plants to potential CO 2 storage options creates a unique atmosphere for PCCC within the state. However, the aerosols present in lignite flue gas present a challenge for large-scale PCCC at North Dakota power plants. Aerosols can negatively impact the long-term performance of amine-based solvents for CO 2 capture. Amine-based solvents are volatile, and aerosols provide nucleation sites where amine vapors can condense. Because aerosols cannot be easily captured at the column outlet using conventional technologies, the amine-laden aerosols escape the system and lead to accelerated solvent losses. Moreover, aerosol components can chemically react with amines to form degradation products that can permanently deactivate the amine, cause fouling, and lead to hazardous emissions. Many of the elements that have been shown to catalyze solvent degradation are present in lignite coals and can exacerbate solvent replacement economics. Understanding this issue is critical to the implementation of solvent-based CO 2 capture systems as applied to lignite-fired generation systems. The Energy & Environmental Research Center (EERC) designed and carried out this project to optimize aerosol mitigation technology for PCCC at a lignite-fired power plant. To meet the goal of this project, the following objectives were identified: Determine the effectiveness of a wet electrostatic precipitator (WESP) on collection of aerosols at a low-rank coal-fired power station. Determine the impact of aerosols on the efficiency and degradation products of amine-based carbon capture systems fired with low-rank fuels. Work was conducted at Minnkota Power Cooperative’s (MPC’s) Milton R. Young (MRY) Station Unit 2 using a slipstream of flue gas from the outlet of the plant’s flue gas desulfurization (FGD) unit. To gather initial data for sizing and specifying a WESP for this system, a temporary pilot-scale WESP was rented and installed on-site. Several different conditions were tested to examine the impact of flow rate, voltage, and current on WESP performance. The WESP was effective at removing large particulate (>200 nm) but caused an increase in fine particulate (<75 nm). Fine particulate material at the inlet and outlet of the WESP was collected, analyzed, and showed that crystalline sulfates carried over from the plant’s FGD unit were being converted to fine aerosols and SO 2 was being converted to SO 3 through the WESP. Additionally, the high moisture content of the flue gas stream at this sample location also contributed to an overall increase in aerosol mass under some of the test conditions. Using the results from the rented WESP, the project team installed a smaller-scale WESP upstream of the EERC’s slipstream CO 2 capture system. Flue gas was routed through a pilot-scale FGD unit to remove SO 2 to very low levels (~1 ppm) and then through a direct contact cooler (DCC) to further cool the gas and to remove moisture. The gas exiting the DCC was then routed through the new WESP before passing to the CO 2 absorber columns. Fluor’s amine-based solvent was used to scrub CO 2 from the slipstream through a set of two absorber columns. The rich solvent was regenerated in a stripper column by heating to drive off captured CO 2 . The system operated using a catch-and-release method where the CO 2 was separated to provide data on the process, but the captured CO 2 was released back into the host site stack. Aerosols and sulfur species were measured at multiple locations throughout the pilot-scale system. The inlet FGD and DCC removed much of the particulate matter and gaseous sulfur upstream of the WESP. With this configuration, the WESP achieved >95% particulate capture. The new WESP did not show any of the increases in SO 3 or other aerosol species that had been consistently observed with the larger-scale WESP installed immediately downstream of the plant’s full-scale FGD unit. Particulate samples captured and analyzed from the WESP inlet did not show any presence of crystalline sulfate materials, indicating that the pilot-scale FGD and DCC were efficient at reducing carryover from the plant’s full-scale FGD unit. A set of parametric tests were conducted on the new WESP to assess the impacts of flow rate, voltage, number of online WESP fields, and gas-phase sulfur content on aerosol and sulfur transformations. The results showed that the WESP performed similarly well at all sets of conditions. Sulfur and particulate matter exiting the WESP were further reduced through the absorber column as the amine-based solvent captured some of the residual contaminants. Solvent analysis showed that these species were slowly concentrating in the solvent over the duration of the test. When the WESP was taken offline and the sulfur slip through the FGD allowed to rise, the sulfate content in the solvent rose sharply, showing that the extra FGD and WESP were effective at reducing sulfate and cation uptake. This would be expected to extend amine-based solvent life by slowing the formation of heat-stable salts and other degradation products. This subtask was cofunded through the EERC–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Industrial Commission and MPC.

01 COAL, LIGNITE, AND PEAT↗

A Historic Context and Mitigation Documentation for a Portion of the U12n Tunnel Ventilation and Containment Systems, Area 12, Nevada National Security Site, Nye County, Nevada

The National Nuclear Security Administration Nevada Field Office (NNSA/NFO) has proposed repurposing the U12n Vent Hole #2 (SHPO Resource S2488) and the U12n.10 Vent Hole (S2489) for water sampling in the U12n Tunnel. The vent holes are part of the historic ventilation system for the tunnel and are contributing elements to the U12n Tunnel Historic District (D84). In consultation with the SHPO, NNSA/NFO determined the undertaking will have an adverse effect on the vent holes. The NNSA/NFO and the SHPO negotiated a memorandum of (MOA) with stipulations to mitigate adverse effects. This submission is to comply with the stipulations in the executed Memorandum of Agreement Between the National Nuclear Security Administration Nevada Field Office, Environmental Management Nevada Program Office, and the Nevada State Historic Preservation Officer Regarding Repurposing of Portions of the Ventilation System of the U12n Tunnel Complex Located in Area 12 at the Nevada National Security Site. In accordance with the MOA, the manuscript provides a historic context that describes the development and functioning of the historic U12n Tunnel ventilation system for underground nuclear tests (Stipulation III.C). High resolution digital color images of the vent hole containment doors, nearby elements, and overviews were obtained and keyed to a map and a photo index (Stipulation III.A) (Appendix A). Lastly, Architectural Resource Assessment (ARA) forms were completed for each of the vent holes and Historic District D84 (Stipulation III.B) (Appendix B). The documentation including the historic context report, photographs, image files, and resource forms produced to fulfill the terms of the MOA will be archived with the Nuclear Testing Archive in Las Vegas (Stipulation III.D).

54 ENVIRONMENTAL SCIENCES↗

Methane Mitigation Thermoelectric Generator (MMTEG) (Final Scientific/ Technical Report)

Gas Technology Institute (GTI) has completed a $1.815M (plus $500K cost share), 54-month Co-operative agreement with the Department of Energy’s National Energy Technology Laboratory to develop a Methane Mitigation Thermoelectric Generator (MMTEG) system for gas field applications. This novel system uses fugitive gas to produce electrical power and consists of Thermoelectric Generators (TEG) driven by a linear burner, an air compressor, an accumulator, valves, batteries, and power electronics. The electrical power generated by the system is used to compress air and, in turn, the air is used to operate the pneumatic valves at the well site instead of using natural gas (NG) which would then be vented. The team completed the project objectives which included (1) Design, fabricate and test an integrated 6We nominal MMTEG prototype system, (2) Design a “retrofit kit” MMTEG system capable of being field tested at a gas well production site, and (3) build and test the field MMTEG system in a laboratory environment. Multiple system options were developed prior to selecting a “Passive” system which meets cost, NG savings, and greenhouse gas (GHG) reduction targets although not as efficient as initially planned. The MMTEG system is built primarily from commercial off-the-shelf parts (in some cases re-purposed) including the heat exchanger, heat rejection, electronic components, and also the TEGs. The team developed and implemented a novel system including the control system developed by Morrison Applied Sciences (MAS). The team completed incremental demonstrations of the hardware prior to the MMTEG system demonstration. A one-year simulation of the air delivery and battery charging subsystems was completed prior to the integration into the MMTEG system. In addition, the team simulated two-years of thermal cycles for integrated Burner/TEG/heat rejection subsystem. Finally, the entire MMTEG system was assembled, and troubleshooting was completed over a two-week period. Next, the MMTEG system was tested to simulate over 15 weeks of entire system operation over approximately four weeks in an accelerated test fashion with minimal intervention (such as changing fuel tanks). The MMTEG system met the key goals of a unit cost of under $1500 while saving 97% of NG expended today (including leakage) on average by pneumatic systems venting to the atmosphere. The MMTEG system reduced GHG emissions by 1000X (using the methane intensification factor of 28 relative to CO2). GTI is currently pursuing a field test of the MMTEG system. Interfacing with producers has provided additional insight into system improvements. Planned improvements include additional weather protection and control system improvements including the implementation of a long- range radio capability to notify operators if there is a fault.

03 NATURAL GAS↗

Intelligent Monitoring Systems and Advanced Well Integrity and Mitigation

Long-term seismic monitoring of carbon capture and storage projects is needed to verify that the injected gas is safely stored in the subsurface until permanence can be assured. Conventional surface seismic monitoring techniques are usually expensive, require highly invasive surface operations, and need significant time investments on the part of personnel for both the field effort and processing the acquired data. For these reasons, permanent reservoir monitoring technologies are preferred, as they can offer a cost-effective solution for long-term monitoring. As part of the monitoring program of the Archer Daniels Midland’s large-scale injection of CO 2 in Decatur, Illinois, USA, a continuous seismic monitoring array was installed using a combination of surface orbital vibrator (SOV) sources and fiber-optic cables for distributed acoustic sensing (DAS) acquisition with the objective to build a continuous monitoring array. The aim of the presented project was to build a monitoring array and platform that integrates real-time seismic data with conventional data streams and provides continuous data analysis using dynamic computational models to deliver a comprehensive real-time assessment of subsurface conditions. It is in this context that the Intelligent Monitoring Systems and Advanced Well Integrity and Mitigation project was proposed with the objective to develop an integrated architecture that utilizes a permanent seismic monitoring network, combines the real-time geophysical and process data with reservoir flow and geomechanical models to create a comprehensive monitoring, visualization, and control system that delivers critical information for process surveillance and optimization.

54 ENVIRONMENTAL SCIENCES↗