Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Mars Sample Return”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Pattern-Recognition System for Approaching a Known Target

A closed-loop pattern-recognition system is designed to provide guidance for maneuvering a small exploratory robotic vehicle (rover) on Mars to return to a landed spacecraft to deliver soil and rock samples that the spacecraft would subsequently bring back to Earth. The system could be adapted to terrestrial use in guiding mobile robots to approach known structures that humans could not approach safely, for such purposes as reconnaissance in military or law-enforcement applications, terrestrial scientific exploration, and removal of explosive or other hazardous items. The system has been demonstrated in experiments in which the Field Integrated Design and Operations (FIDO) rover (a prototype Mars rover equipped with a video camera for guidance) is made to return to a mockup of Mars-lander spacecraft. The FIDO rover camera autonomously acquires an image of the lander from a distance of 125 m in an outdoor environment. Then under guidance by an algorithm that performs fusion of multiple line and texture features in digitized images acquired by the camera, the rover traverses the intervening terrain, using features derived from images of the lander truss structure. Then by use of precise pattern matching for determining the position and orientation of the rover relative to the lander, the rover aligns itself with the bottom of ramps extending from the lander, in preparation for climbing the ramps to deliver samples to the lander. The most innovative aspect of the system is a set of pattern-recognition algorithms that govern a three-phase visual-guidance sequence for approaching the lander. During the first phase, a multifeature fusion algorithm integrates the outputs of a horizontal-line-detection algorithm and a wavelet-transform-based visual-area-of-interest algorithm for detecting the lander from a significant distance. The horizontal-line-detection algorithm is used to determine candidate lander locations based on detection of a horizontal deck that is part of the lander.

Huntsberger, Terrance↗

Mars 2020's First Sample: The Fractured Rough Rock Unit on the Floor of Jezero Crater

A central goal of the Mars 2020 mission is to select and cache samples for future return to Earth. The first samples targeted for collection are from the crater-retaining, Crater Floor Fractured Rough (CF-Fr) unit of Stack et al., 2020.The CF-Fr unit is a topographically low unit in the current Jezero setting, likely overlain by morphologically discrete units, including possible Jezero delta deposits and eolian features. CF-Fr is an aerially extensive unit with lobate margins. Two distinct morphologies are observed: a locally-exposed lower expression, with flat relatively horizontal light-toned surfaces and polygonal fracturing, and an upper expression consisting of up to ~5vertical meters of massive, sometimes boulder-producing, material. The locally-exposed lower expression appears to represent a local ground level in which the upper material has been removed. Near the Octavia E. Butler landing site, the lower morphology is exposed as polygonally-fractured, light-toned bedrock that appears to grade continuously into higher-standing massive outcrops, often with no clearly exposed contact. Further south, a darker upper expression of the CF-Fr unit is more distinct and the unit exhibits some horizontal layering. The Perseverance rover will initially sample the flat-lying expression of this unit. Hypotheses for the origin of CF-Fr include fluvial, aeolian, or lacustrine sediment likely derived from the Jezero watershed, and/or pyroclastic material resulting from regional volcanism. Geochronology of the returned sample could be used to help constrain the timing of geological events in Jezero. It may also help constrain stratigraphic relationships with crater-retaining units outside of Jezero within the Nili Planum, which could be used to calibrate the cratering chronology of Mars. Paleomagnetic analyses of an oriented sample could establish the history of the martian dynamo and whether it persisted into the Hesperian. Finally, if present, secondary phases within the primary deposit would help constrain diagenetic conditions and inform post-depositional aqueous and potentially habitable environmental conditions.

Justin I Simon↗

Restricted and Uncontained: Health Care and Public Health Considerations in the Event of Loss of Containment During the Restricted Earth Return of Extraterrestrial Samples

The normal scope of an adequate public health response to released biological material is framed by working with biological vectors with known pathogenicity and virulence. Defining the scope of a response to the release of biological material with unknown pathogenicity and virulence enters into a novel and yet to be framed domain. A current case, the case of returning samples from a location other than Earth, extraterrestrial samples from a location such as Mars, which may harbor life as we know it, requires framing a public health response. An unintentional release of biological material with unknown pathogenicity and virulence may occur when biological containment mechanisms in the Earth-returning transport method are lost. This paper raises initial public health and healthcare response questions during a return of extraterrestrial samples to Earth, in the event of its release from biological containment mechanisms: How does the public health community prepare for a response when there is release of samples that may contain potential extraterrestrial organisms from a planetary body or hardy terrestrial organisms surviving a round trip? If a mishap occurs during the return of these samples, what considerations need to be made to confine, decontaminate, and collect material in regions around the mishap? How will the public health community work with relevant government organizations to prepare the general public? The unknowns of exposure, potential extraterrestrial pathogenicity, and decontamination approaches, underscore gaps in biopreparedness for this novel case from the federal to local levels.

Betsy Pugel↗

Pneumatic Sampler (P-Sampler) for the Martian Moons Exploration (MMX)

The Martian Moons eXploration (MMX) mission, led by the Japanese Aerospace Exploration Agency (JAXA), will focus on the exploration of the two Martian moons – Phobos and Deimos (Figure 1). The spacecraft will perform close-up remote sensing and observations of both moons and collect a sample from Phobos for Earth sample return. MMX has set the two mission goals: (1) determining the origin of the Martian moons and (2) observing processes in the circumplanetary environment of Mars, based on remote sensing, in-situ observations, and laboratory analyses of returned samples of Phobos regolith [1-2]. To fulfill the mission goals, MMX employs a double sampling approach: Coring and Pneumatic Samplers (Figure 2).The Coring Sampler (C-Sampler), a core soil tube deployed by a robotic arm, providing access to the building blocks of Phobos beneath the surface (>2 cm), and also collect a mixture of near surface material. The P-Sampler, on the other hand, would selectively sample the surface veneer and provides reference of surface component with the C-Sampler. The double sampling system not only enhances the scientific merits of MMX but also reduces risks associated with the sampling of Phobos. Without enough knowledge of the physical and chemical properties, and the geotechnical conditions of the surface of Phobos (e.g., compositions, temperature gradient/variation, porosity, grain size distribution), having two sampling systems that utilize entirely different sampling approaches is prudent.

Dylan Van Dyne↗

Thermal Design, Analysis, and Sensitivity of a Sample Tube on the Martian Surface

NASA will launch a rover to Mars in 2020 to collect and cache samples of Martian rocks and regolith for potential return to Earth on a future mission. The collected samples will be placed in tubes, hermetically sealed, and deposited on the surface of Mars for a period of up to 10 years. Preventing the deposited samples from overheating is an important consideration in order to ensure their scientific integrity. The samples are required to remain below 60 °C, however there is a goal to keep them below 40 °C. This temperature requirement is challenging, considering that the maximum surface temperature of Mars is 38 °C and the tube must be thermally controlled through only passive means. As a result, a significant effort has been made to design a tube to contain the samples and investigate innovative tube surface treatments that maintain proper sample temperatures without significant adverse effects of sample contamination. The tube uses a specialized aluminum oxide coating to prevent overheating on the Martian surface. The maximum predicted tube temperature is relatively insensitive to local thermal inertia, ground contact, and ground slope, but is very sensitive to landing site latitude and dust deposition. The maximum predicted sample temperature in the +/- 30° landing latitude range with worst case assumptions is 54 °C, but many of the potential landing sites have significantly cooler maximum predicted sample temperatures. This paper describes the thermal design, analysis, and sensitivity studies performed on the sample tubes and also discusses operational considerations.

Novak, Keith↗

Mars Ascent Vehicle - Payload?, Spacecraft?, Launch Vehicle? - A Systems Approach to MAV

Significant effort has been expended over the past few years in order to examine propulsion technologies for an eventual robotic Mars Ascent Vehicle (MAV). The recent emphasis on studies for an overall sample return campaign, and specifically the Sample Return Lander (SRL) includes the full slate of systems required to implement a MAV. Depending on your point of view, the MAV is a major SRL flight system payload, a Mars Surface Spacecraft, or a Launch Vehicle. We will examine the MAV from these three perspectives in order to tease out the key architectural trades required to be completed prior to the start of a project Phase A activity.

Jackman, Angie↗

Clean is not Sterile: A Planetary Science and Planetary Protection Perspective on Cleanroom Microbiology at NASA

The Astromaterials Acquisition and Curation Office at NASA is responsible for the curation of extraterrestrial samples from NASA’s past and future sample return missions. Our office curates samples from the moon, meteorites, comets, asteroids, cosmic dust and solar wind particles. All these samples are kept in cleanrooms to limit particulate and trace metal contamination, but none of these cleanrooms are specifically designed to control microbial contamination. During the early Apollo missions NASA scientists were very concerned with protecting the Earth from potential microbial contamination from the moon and with protecting the lunar samples from terrestrial microbes. NASA developed specialized equipment and clean rooms to keep these collections pristine. However, as we learned more about the lunar environment our concerns about microbial contamination lessened. Today none of the existing collections have microbial contamination requirements because they are not considered susceptible to microbial alteration under curation conditions (e.g. solar wind samples, and lunar samples) or have already been contaminated by terrestrial biology (meteorites collected in Antarctica). However, NASA’s OSIRIS-REx mission will land in 2023 with samples from a carbon rich asteroid that will be susceptible to microbial alteration. The Perseverance rover on Mars will begin to collect and cache samples that will be returned to Earth as soon as 2031. Martian samples may contain signs of extraterrestrial life and will have to be treated like the early Apollo samples. Martian samples will be isolated to protect the Earth, and must also be protected from terrestrial contamination. I will present microbial monitoring data from existing NASA cleanrooms and discuss how NASA is planning to use techniques from the pharmaceutical industry and academia to design new laboratories and equipment that will protect astromaterials and the earth from unwanted microbial contamination. I will also discuss a project to sample the external microbiome of the International Space Station. Results from this research will be used to design facilities for use on Mars that limit the amount of contamination associated with crewed missions.

Aaron B Regberg↗

Jet Propulsion Laboratory: Annual Report 1999

The Jet Propulsion Laboratory, located in the foothills near Pasadena, California, is the nation's lead center for the robotic exploration of space. Intense activity in space missions was the hallmark of the Jet Propulsion Laboratory as a new generation of smaller, less expensive spacecraft were sent out from Earth. From late 1998 to mid-1999, JPL launched a craft testing a futuristic ion engine, an orbiter and lander bound for Mars, a mission to fly by a comet and return a sample of its dust to Earth, a small infrared telescope, and an Earth-circling satellite that uses radar to gauge winds over the oceans. This unprecedented schedule resulted in spectacular achievements, tempered by highly visible mission losses. Weighed together, the successes and failures dramatically underscored the difficulty and risk involved in the unique business of space science and exploration. Among the achievements, the ion-engine-powered Deep Space 1, comet-bound Stardust and Earth-orbiting SeaWinds were joined by such ongoing missions as Mars Global Surveyor, Galileo and Cassini in delivering on their promise and, in some cases, providing surprising new views of space and Earth. At the same time, mission teams were disappointed by the losses of an orbiter and lander at Mars, as well as a small infrared telescope. JPL worked closely with NASA to learn from these experiences and build successful future missions. The Laboratory also achieved a key goal by winning the International Organization of Standards' 'ISO 9001' certification - a standard shared by the world's best engineering organizations. As the year rolled to a close, clocks rolled over from 1999 to 2000. Operations teams at JPL and NASA watched with satisfaction as a major campaign of Year 2000 readiness paid off with no problems among the thousands of computer systems that support the Laboratory's missions. With that auspicious beginning, JPL was positioned to step into the 21st century and embark on even yet unimagined future explorations.

Jet Propulsion Laboratory (JPL)↗

Imaging of Vanadium in Microfossils: A New Potential Biosignature

Being able to distinguish unambiguously the biogenicity of microfossil-like structures in the ancient rock record is a fundamental predicament facing Archean paleobiologists and astrobiologists. Therefore, novel methods for discriminating biological from non-biological chemistries of microfossil-like structures are of the utmost importance in the search for evidence of early life on Earth. This too, is important for the search for life on Mars; either by in situ analyses via rovers, or sample return missions for future analysis here on Earth. Here, we report the application of synchrotron X-ray fluorescence imaging of vanadium, within thermally altered organic-walled microfossils of bona fide biological origin. From our data, we demonstrate that vanadium is present within microfossils of undisputable biological origin. It is well known in the organic geochemistry literature, that elements such as vanadium are enriched and contained within crude oils, asphalts, and black shales that have been formed by diagensis of biological organic material. It has been demonstrated that the origin of vanadium is due to the diagenetic alteration of precursor chlorophyll and heme porphyrin pigment compounds from living organisms. Here, we propose that taken together, microfossil-like morphology, carbonaceous composition, and the presence of vanadium could be used in tandem as a biosignature to ascertain the biogenecity of putative microfossil-like structures.

59 BASIC BIOLOGICAL SCIENCES↗

Mars exploration planning

The topics are presented in viewgraph form and include the following: Mars Observer; Mars Environmental Survey (MESUR); and the Small Rovers and Sample Return missions.

Dickinson, Tamara L.↗

A Miniature Laser Desorption/Ionization Time-of-Flight Mass Spectrometer for in Situ Analysis of Mars Surface Composition and Identification of Hazard in Advance of Future Manned Exploration

Future landed missions to Mars will be guided by two strategic directions: (1) sample return to Earth, for comprehensive compositional analyses, as recommended by the 2011 NRC Planetary Decadal Survey; and (2) preparation for human exploration in the 2030s and beyond, as laid out by US space policy. The resultant mission architecture will likely require high-fidelity in situ chemical/organic sample analyses within an extremely constrained resource envelope. Both science goals (e.g., MEPAG Goal 1, return sample selection, etc.) as well as identification of any potential toxic and biological hazards to humans, must be addressed. Over the past several years of instrument development, we have found that the adaptable, compact, and highly capable technique of laser desorption/ionization time-of-flight mass spectrometry (LD-TOF-MS) has significant potential to contribute substantially to these dual objectives. This concept thus addresses Challenge Area 1: instrumentation and Investigation Approaches.

Getty, S. A.↗

Mars sampling strategy and aeolian processes

It is critical that the geological context of planetary samples (both in situ analyses and return samples) be well known and documented. Apollo experience showed that this goal is often difficult to achieve even for a planet on which surficial processes are relatively restricted. On Mars, the variety of present and past surface processes is much greater than on the Moon and establishing the geological context of samples will be much more difficult. In addition to impact hardening, Mars has been modified by running water, periglacial activity, wind, and other processes, all of which have the potential for profoundly affecting the geological integrity of potential samples. Aeolian, or wind, processes are ubiquitous on Mars. In the absence of liquid water on the surface, aeolian activity dominates the present surface as documented by frequent dust storms (both local and global), landforms such as dunes, and variable features, i.e., albedo patterns which change their size, shape, and position with time in response to the wind.

Greeley, Ronald↗

Assessing Ceres’ Past and Current Habitability

Dwarf planet Ceres is a compelling target as an evolved ocean world with, at least, regional brine reservoirs and potentially ongoing geological activity. Situated in the Main Belt of asteroids, Ceres is the most water-rich body in the inner solar system (in relative abundance) and is accessible enough for a sample return with the resources of a typical medium-class (New Frontiers) NASA mission. NASA’s Dawn mission at Ceres revealed the presence of liquid, brine-driven activity, organic matter, and a rich salt chemistry. With this evidence, the overarching goals of the mission concept presented herein are to quantify Ceres’ current habitability potential and origin. A sample return from young evaporite deposits in Occator crater offers greater science return than an in situ exploration mission by enabling high-resolution analysis of (1) organic matter expected from terrestrial and chondritic analogs that are trapped in salt minerals and (2) isotopes of refractory elements for a similar cost and less science risk. The sample return concept would be executed with a single flight system due to Ceres’ relative proximity to Earth and low gravity. Solar electric propulsion was identified as the most cost-effective approach for getting to Ceres and back. De-orbiting, landing, and takeoff are performed with a throttleable monopropellant hydrazine system. The solar arrays are stowed prior to landing and takeoff. Sample acquisition builds on the pneumatic system designed by Honeybee Robotics. The sample return mission concept relies on the availability of key technologies: an enhanced landing vision system leveraging investments from Mars 2020; retractable/redeployable solar arrays, which have been demonstrated on the International Space Station but not at Ceres’ gravity; and an emerging design from upcoming missions for sample transfer from the pneumatic sampling system to the sample return capsule. Return of a sample of mass ~100 g from Ceres, maintained at ≤ -20°C, is without precedent for any currently advocated Ocean World mission, enabling a vast range of experimental techniques back on Earth with sensitivities and accuracies far beyond those feasible with in situ instruments. A sample of this size also enables analyses to benefit from techniques that will become available in the future.

Casillas, Raul Polit↗

MSL Entry, Descent, and Landing Instrumentation: Return on Investment

On Aug 5, 2012 the Mars Science Laboratory (MSL) Entry, Descent, and Landing Instrumentation (MEDLI) suite on MSL entry vehicle heatshield suc-cessfully returned surface pressure and in-depth temperature data.1,2 The MEDLI data has given scientists and engineers an unprecedented ability to reconstruct entry environment, atmospheric density, and flight trajectory, and flight validation of predic-tions vehicle aerodynamics and thermal protection system (TPS) performance. This presentation will dis-cuss key findings from MEDLI, some of which are being applied to improve definition of aerothermal environment and TPS sizing margins for existing NASA entry missions. The postflight analysis has shown that a significant thermal protection mass saving upon redesign is possible for an MSL-class vehicle. The success of MEDLI has also demonstrated and qualified robust flight instrumentation technologies at very low risk to the mission. The potential benefits of MEDLI to planetary exploration and sample return missions, as well as to exploration class missions to Mars will be presented.

MEDLI↗

Perseverance Rover Collision Model for a range of Autonomous Behaviors

The NASA Mars 2020 Perseverance rover landed in Jezero crater on Mars on 18 February 2021. It is a science mission to collect and cache sample cores for possible return to Earth in the future. Robot collision modeling is traditionally used in robotics for hardware safety for manipulation and sampling. The Mars 2020 Rover Collision Model (RCM) optimizes and extends collision checking in innovative ways to provide a range of onboard autonomous capability on a computationally constrained system. It provides an example of the benefit of systems and operations cognizant software design and development of autonomous systems.

Klein, Douglas↗

Cleanroom Robotics: Appropriate Technology for a Sample Receiving Facility?

NASA is currently pursuing a vigorous program that will collect samples from a variety of solar system environments. The Mars Exploration Program is expected to launch spacecraft that are designed to collect samples of martian soil, rocks, and atmosphere and return them to Earth, perhaps as early as 2016. International treaty obligations mandate that NASA conduct such a program in a manner that avoids cross-contamination both Earth and Mars. Because of this requirement, Mars sample curation will require a high degree biosafety, combined with extremely low levels inorganic, organic, and biological contamination.

Bell, M. S.↗

Development of Cryogenic Phase Change Materials for Lunar Sample Return

One of the scientific goals of NASA’s Artemis missions is to return regolith samples from the lunar surface. To maintain scientific integrity of these samples, including any volatiles that may exist, cryogenic stowage is desired. FROSTE (Frozen Return Of Samples To Earth) is the element of the Moon to Mars architecture that is tasked with developing and advancing concepts related to this goal. Both active and passive solutions are being considered, but active solutions (cryo-coolers) have high mass and cost penalties. Phase change materials (PCMs) are commonly used as passive thermal management solutions, particularly for sensitive scientific samples. However, there are currently no PCMs capable of providing cooling at the cryogenic temperatures needed to enable lunar sample return with volatiles intact (<120 K). FROSTE has identified two possible candidate materials that could fill this gap. Testing is required to verify the thermal performance of these materials, as well as gain experience with their handling characteristics. We are conducting this testing at the Marshall Space Flight Center’s Space Environmental Effects laboratory, in vacuum, with liquid nitrogen providing cooling ability below the freezing point of the materials. In this talk, we will present an overview of the FROSTE program element and share results from the initial development testing of two cryogenic phase change materials.

phase change material↗