Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MIRROR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Neutrino Emission in the Hadronic Synchrotron Mirror Model: The "Orphan" Flare from 1ES 1959+650

A challenge to standard leptonic synchrotron self-Compton (SSC) models is the so-called orphan TeV flares, i.e., enhanced very high energy (VHE) gamma-ray emission without any contemporaneous X-ray flaring activity, that have recently been observed in TeV blazars (e.g., 1ES 1959+650). In order to explain the orphan TeV flare of 1 ES 1959+650 observed in 2002 June, the so-called hadronic synchrotron mirror model has been developed. Here relativistic protons are proposed to exist in the jet and interact with reflected electron synchrotron radiation of the precursor SSC flare. If the reflector is located in the cloud region, time shifts of several days are possible between the precursor and the orphan flare. The external photons, blue-shifted in the comoving jet frame, are able to excite the Delta(1232) resonance when interacting with protons of Lorentz factors gamma(sub p) approx. 10(exp 3)-10(exp 4). The decay products of this resonance include charged pions, which, on decay, give rise to neutrino production during the orphan flare. In this paper we calculate the expected neutrino emission for the 2002 June 4 orphan TeV flare of 1ES 1959+650. We compare our results with the recent observations of AMANDA-II of a neutrino event in spatial and temporal coincidence with the orphan flare of this blazar. We find that the expected neutrino signal from the hadronic synchrotron mirror model is insufficient to explain the claimed neutrino signal from the direction of 1ES 1959+650.

Reimer, A.↗

Mirror Birefringence in a Fabry-Perot Cavity and the Detection of Vacuum Birefringence in a Magnetic Field

We discuss the effect of mirror birefringence in two optical schemes designed to detect the quantum-electrodynamics (QED) predictions of vacuum birefringence under the influence of a strong magnetic field, B. Both schemes make use of a high finesse Fabry-Perot cavity (F-P) to increase the average path length of the light in the magnetic field. The first scheme, which we called the frequency scheme, is based on measurement of the beat frequency of two orthogonal polarized laser beams in the cavity. We show that mirror birefringence contributes to the detection uncertainties in first order, resulting in a high susceptibility to small thermal disturbances. We estimate that an unreasonably high thermal stability of ~10-9 K is required to resolve the effect to 0.1%. In the second scheme, which we called the polarization rotation scheme, laser polarized at 45 relative to the B field is injected into the cavity.

Vacuum Birefringence↗

Flextensional Single Crystal Piezoelectric Actuators for Membrane Deformable Mirrors

Large aperture and light weight space telescopes requires adaptive optics with deformable mirrors capable of large amplitude aberration corrections at a broad temperature range for space applications including NASA missions such as SAFIR, TPF, Con-X, etc. The single crystal piezoelectric actuators produced at TRS offer large stroke, low hysteresis, and an excellent cryogenic strain response. Specifically, the recently developed low profile, low voltage flextensional single crystal piezoelectric actuators with dimensions of 18 x 5 x 1 mm showed stroke larger than 95 microns under 300 V. Furthermore, flextensional actuator retained approx. 40-50% of its room temperature strain at liquid Nitrogen environment. In this paper, ATILA FEM design of flextensional actuators, actuator fabrication, and characterization results will be presented for the future work on membrane deformable mirror.

Jiang, Xiaoning↗

Fabrication of Extremely Lightweight Mirrors

Further progress in astronomy requires large.(approx. 10m class) space telescopes in all wavelength bands, from IR to X-rays. The enabling of this progress requires optical fabrication technologies that not only can make mirrors that are orders of magnitude less massive than the present ones, but also orders of magnitude less expensive. In the past five years, we have been developing lightweight X-ray mirrors to meet mission requirements of the Constellation-X, which is NASA s next major X-ray observatory scheduled for launch some time in the next decade. In this talk, I will describe in detail a glass forming, or slumping, technique that allows a high-fidelity copying of a mandrel s figure while preserving the microroughness of the float glass surface. In particular, I will address the possibility of applying this technique to making extremely large optical telescopes.

Zhang, William W.↗

Alignment and Integration Techniques for Mirror Segment Pairs on the Constellation X Telescope

We present the concepts behind current alignment and integration techniques for testing a Constellation-X primary-secondary mirror segment pair in an x-ray beam line test. We examine the effects of a passive mount on thin glass x-ray mirror segments, and the issues of mount shape and environment on alignment. We also investigate how bonding and transfer to a permanent housing affects the quality of the final image, comparing predicted results to a full x-ray test on a primary secondary pair.

Hadjimichael, Theo↗

An Automated SVD for Alignment and Control of James Webb Space Telescope Mirrors

The James Webb Space Telescope (JWST) is a three-mirror anastigmatic telescope. The alignment of the segmented primary and secondary mirrors in the wavefront sensing and control process involves a series of actuators to control the six degrees-of-freedom motion on each surface in addition to the radius of curvature. The control matrix developed from the alignment parameters is over-determined and singular value decomposition (SVD) method is used to solve it in the least square sense. An automated SVD scheme has been developed to identify the most contributing modes in a typical alignment process and reduce the impact of error-prone modes from the control process.

Shiri, Sharam↗

Alignment System for Full-Shell Replicated X-Ray Mirrors

We are developing grazing-incidence x-ray optics for high-energy astrophysical applications using the electroformnickel replication process. For space-based applications these optics must be light-weight yet stable, which dictates the use of very-thin-walled full-shell mirrors. Such shells have been fabricated with resolution as good as 11 arcsec for hard x-rays, and technology enhancements under development at MSFC are aimed at producing mirrors with resolution better than 10 arcsec. The challenge, however, is to preserve this resolution during mounting and assembly. We present here a status report on a mounting and alignment system currently under development at Marshall Space Flight Center designed to meet this challenge.

Gubarev, Mikhail↗

A Stainless-Steel Mandrel for Slumping Glass X-ray Mirrors

We have fabricated a precision full-cylinder stainless-steel mandrel at Marshall Space Flight Center. The mandrel is figured for a 30-cm diameter primary (paraboloid) mirror of an 840-cm focal-length Wolter-1 telescope. We have developed this mandrel for experiments in slumping.thermal forming at about 600 C.of glass mirror segments at Goddard Space Flight Center, in support of NASA's participation in the International X-ray Observatory (IXO). Precision turning of stainless-steel mandrels may offer a low-cost alternative to conventional figuring of fused-silica or other glassy forming mandrels. We report on the fabrication, metrology, and performance of this first mandrel; then we discuss plans and goals for stainless-steel mandrel technology.

Gubarev, Mikhail V.↗

NASA's OCA Mirroring System: An Application of Multiagent Systems in Mission Control

Orbital Communications Adaptor (OCA) Flight Controllers, in NASA's International Space Station Mission Control Center, use different computer systems to uplink, downlink, mirror, archive, and deliver files to and from the International Space Station (ISS) in real time. The OCA Mirroring System (OCAMS) is a multiagent software system (MAS) that is operational in NASA's Mission Control Center. This paper presents OCAMS and its workings in an operational setting where flight controllers rely on the system 24x7. We also discuss the return on investment, based on a simulation baseline, six months of 24x7 operations at NASA Johnson Space Center in Houston, Texas, and a projection of future capabilities. This paper ends with a discussion of the value of MAS and future planned functionality and capabilities.

Sierhuis, Maarten↗

A Stainless-Steel Mandrel for Slumping Glass X-Ray Mirrors

We have fabricated a precision full -cylinder stainless-steel mandrel at Marshall Space Flight Center. The mandrel is figured for a 30-cm-diameter primary (paraboloid) mirror of an 840-cm focal-lengthWolter-1 telescope. We have developed this mandrel for experiments in slumping.thermal forming at about 600 C-of glass mirror segments at Goddard Space Flight Center, in support of NASA fs participation in the International X -ray Observatory (IXO). Precision turning of stainless ]steel mandrels may offer a lowcost alternative to conventional figuring of fused -silica or other glassy forming mandrels. We report on the fabrication, metrology, and performance of this first mandrel; then we discuss plans and goals for stainless-steel mandrel technology.

ODell, Stephen L.↗

Design and Analysis of the International X-Ray Observatory Mirror Modules

The Soft X-Ray Telescope (SXT) modules are the fundamental focusing assemblies on NASA's next major X-ray telescope mission, the International X-Ray Observatory (IXO). The preliminary design and analysis of these assemblies has been completed, addressing the major engineering challenges and leading to an understanding of the factors effecting module performance. Each of the 60 modules in the Flight Mirror Assembly (FMA) supports 200-300 densely packed 0.4 mm thick glass mirror segments in order to meet the unprecedented effective area required to achieve the scientific objectives of the mission. Detailed Finite Element Analysis (FEA), materials testing, and environmental testing have been completed to ensure the modules can be successfully launched. Resulting stress margins are positive based on detailed FEA, a large factor of safety, and a design strength determined by robust characterization of the glass properties. FEA correlates well with the results of the successful modal, vibration, and acoustic environmental tests. Deformation of the module due to on-orbit thermal conditions is also a major design driver. A preliminary thermal control system has been designed and the sensitivity of module optical performance to various thermal loads has been determined using optomechanical analysis methods developed for this unique assembly. This design and analysis furthers the goal of building a module that demonstrates the ability to meet IXO requirements, which is the current focus of the IXO FMA technology development team.

McClelland, Ryan S.↗

Null Lens Assembly for X-Ray Mirror Segments

A document discusses a null lens assembly that allows laser interferometry of 60 deg. slumped glass mirror segments used in x-ray mirrors. The assembly consists of four lenses in precise alignment to each other, with incorporated piezoelectric nanometer stepping actuators to position the lenses in six degrees of freedom for positioning relative to each other.

Robinson, David W.↗

Lightweight, Segmented, Mostly Silicon Telescope Mirror

A document presents the concept of a curved telescope primary reflector structure, made mostly of silicon, that would have an areal mass density 1 kg/m2 and would be deployed in outer space, where it would be operated at a temperature in the cryogenic range. The concept provides for adjustment of the shape of the mirror to maintain the required precise optical surface figure despite the flexibility inherent in the ultra-lightweight design. The structure would include a thin mirror layer divided into hexagonal segments supported by flexure hinges on a lightweight two-layer backing structure. Each segment would also be supported at three points by sets of piezoelectric linear microactuators that could impose small displacements along the optical axis. The excitations applied to the aforementioned microactuators would be chosen to effect fine adjustments of the axial positions and the orientations of the segments relative to the supporting structure. Other piezoelectric linear microactuators embedded in the backing structure would enable control of the displacements of the segments along the hexagonal axes; they would also enable control of the curvature of the backing structure and, thus, additional control of the curvature of the reflector.

Yang, Eui-Hyeok↗

Phase Sensor for Aligning a Segmented Telescope Mirror

A phase sensor has been developed for use in aligning a segmented telescope mirror to within a fraction of a wavelength in piston. (As used here, piston signifies displacement of a mirror segment along the optical axis of the telescope.) Such precise alignment is necessary in order to realize the full benefit of the large aperture achievable through segmentation. This phase sensor is achromatic. It is based on two-wavelength shearing interferometry, and can be modified to utilize an extended or broad-band (e.g., white) light source. The sensor optics include a ruled diffraction grating and an imaging lens. The sensor can measure the piston shift between segments as well as aberrations of the segments. It can measure the surface error of an individual segment, making it possible to compensate for the error with optimal amount(s) of piston and/or tilt. The precise capture range of the sensor depends partly on the telescope design; the largest relative piston shifts measurable by use of this sensor are of the order of 100 m. The accuracy of the sensor also depends partly on the telescope design; in general, the accuracy is sufficient to enable alignment to within approximately half a wavelength. The interferometric image is digitized and processed by a simple algorithm in real time, and the output of the algorithm can be used to maintain alignment in real time, even in the presence of atmospheric turbulence. The sensor is robust. Through calibration, it can be made insensitive to (and, hence, tolerant of) misalignments and aberrations of its own optics, most aberrations of the telescope as a whole (in contradistinction to aberrations of individual segments), and most aberrations introduced by atmospheric turbulence

Stahl, Philip↗

Magnetic Interface for Segmented Mirror Assembly

Newly developed magnetic devices are used to create an interface between adjacent mirror segments so that once assembled, aligned, and phased, the multiple segments will behave functionally equivalent to a monolithic aperture mirror. One embodiment might be a kinematic interface that is reversible so that any number of segments can be pre-assembled, aligned, and phased to facilitate fabrication operations, and then disassembled and reassembled, aligned, and phased in space for operation. The interface mechanism has sufficient stiffness, force, and stability to maintain phasing. The key to producing an interface is the correlated magnetic surface. While conventional magnets are only constrained in one direction -- the direction defined by their point of contact (they are in contact and cannot get any closer) -- correlated magnets can be designed to have constraints in multiple degrees of freedom. Additionally, correlated magnetic surfaces can be designed to have a limited range of action.

Stahl, H.↗

Wavefront Calibration Testing of the James Webb Space Telescope Primary Mirror Center of Curvature Optical Assembly

The James Webb Space Telescope (JWST) Optical Telescope Element (OTE) consists of a 6.6 meter clear aperture, all-reflective, three-mirror anastigmat!. The 18-segment primary mirror (PM) presents unique and challenging assembly, integration, alignment and testing requirements. A full aperture center of curvature optical test is performed in cryogenic vacuum conditions at the integrated observatory level to verify PM performance requirements. Two wavefront calibration tests are utilized to verify the low and Mid/High spatial frequency performance ofthe test system. In this paper the methods and results of the wavefront calibration tests are presented.

Olczak, Gene↗

The Marshall Space Flight Center Development of Mirror Modules for the ART-XC Instrument aboard the Spectrum-Roentgen-Gamma Mission

The Marshall Space Flight Center (MSFC) is developing x-ray mirror modules for the ART-XC instrument on board the Spectrum-Roentgen Gamma Mission under a Reimbursable Agreement between NASA and the Russian Space Research Institute (IKI.) ART-XC will consist of seven co-aligned x-ray mirror modules with seven corresponding CdTe focal plane detectors. Currently, four of the modules are being fabricated by the Marshall Space Flight Center (MSFC.) Each MSFC module consist of 28 nested Ni/Co thin shells giving an effective area of 65 sq cm at 8 keV, response out to 30 keV, and an angular resolution of 45 arcsec or better HPD. Delivery of these modules to the IKI is scheduled for summer 2013. We present a status of the ART x-ray modules development at the MSFC.

Gubarev, Mikhail V.↗