Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC RESONANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Open-Access, Low-Magnetic-Field MRI System for Lung Research

An open-access magnetic resonance imaging (MRI) system is being developed for use in research on orientational/gravitational effects on lung physiology and function. The open-access geometry enables study of human subjects in diverse orientations. This system operates at a magnetic flux density, considerably smaller than the flux densities of typical other MRI systems, that can be generated by resistive electromagnet coils (instead of the more-expensive superconducting coils of the other systems). The human subject inhales air containing He-3 or Xe-129 atoms, the nuclear spins of which have been polarized by use of a laser beam to obtain a magnetic resonance that enables high-resolution gas space imaging at the low applied magnetic field. The system includes a bi-planar, constant-current, four-coil electromagnet assembly and associated electronic circuitry to apply a static magnetic field of 6.5 mT throughout the lung volume; planar coils and associated circuitry to apply a pulsed magnetic-field-gradient for each spatial dimension; a single, detachable radio-frequency coil and associated circuitry for inducing and detecting MRI signals; a table for supporting a horizontal subject; and electromagnetic shielding surrounding the electromagnet coils.

Mair, Ross W.↗

MR-Guided Focused Ultrasound for the Treatment of Uterine Fibroids

Magnetic resonance imaging-guided focused ultrasound (MRgFUS) ablation of uterine fibroids provides a minimally invasive outpatient technique for targeting and treating symptomatic uterine fibroids. Magnetic resonance imaging provides a guidance platform that has high temporal and spatial resolution for guiding, as well as thermal monitoring of the procedure. The high-intensity focused ultrasound provides a mechanism for delivering large amounts of energy directly into the fibroid without causing detrimental effects to the nontarget tissues. Early and intermediate follow-up of patients treated with MRgFUS provided promising results on the efficacy of the technique for providing symptom relief to patients. As more long-term follow-up data are published, the efficacy of this technique can be compared to more invasive surgical and minimally invasive catheter treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Thermo-physical and structural studies of sodium zinc borovanadate glasses in the region of high concentration of modifier oxides

Highlights: ► Highly modified sodium zinc borovanadate glasses. ► Structural model for borovanadate glasses. ► Network forming tendency of ZnO in borovanadate glasses. ► Fragility can be limited to NBO concentration in borovanadate glasses. -- Abstract: This paper reports investigation of Na{sub 2}O and ZnO modified borovanadate glasses in the highly modified regime of compositions. These glasses have been prepared by microwave route. Ultraviolet (UV) and visible, infrared (IR), Magic Angle Spinning Nuclear Magnetic Resonance (MAS NMR) and Electron Paramagnetic Resonance (EPR) spectroscopies have been used to characterize the speciation in the glasses. Together with the variation of properties such as molar volume and glass transition temperatures, spectroscopic data indicate that at high levels of modification, ZnO tends to behave like network former. It is proposed that the observed variation of all the properties can be reasonably well understood with a structural model. The model considers that the modification and speciation in glasses are strongly determined by the hierarchy of group electronegativities. Further, it is proposed that the width of the transitions of glasses obtained under same condition reflects the fragility of the glasses. An empirical expression has been suggested to quantify fragility on the basis of width of the transition regions.

36 MATERIALS SCIENCE↗

Resolving Chemical and Spatial Heterogeneities at Complex Electrochemical Interfaces in Li-Ion Batteries

The high specific capacities of Ni-rich transition metal oxides have garnered immense interest for improving the energy density of Li-ion batteries (LIBs). Despite the potential of these materials, Ni-rich cathodes suffer from interfacial instabilities that lead to crystallographic rearrangement of the active material surface as well as the formation of a cathode electrolyte interphase (CEI) layer on the composite during electrochemical cycling. While changes in crystallographic structure can be detected with diffraction-based methods, probing the chemistry of the disordered, heterogeneous CEI layer is challenging. In this work, we use a combination of ex situ solid-state nuclear magnetic resonance (SSNMR) spectroscopy and X-ray photoemission electron microscopy (XPEEM) to provide chemical and spatial information, on the nanometer length scale, on the CEI deposited on LiNi 0.8 Mn 0.1 Co 0.1 O 2 (NMC811) composite cathode films. XPEEM elemental maps offer insight into the lateral arrangement of the electrolyte decomposition products that comprise the CEI and paramagnetic interactions (assessed with electron paramagnetic resonance (EPR) and relaxation measurements) in 13 C SSNMR provide information on the radial arrangement of the CEI from the NMC811 particles outward. Using this approach, here we find that LiF, Li 2 CO 3 , and carboxy-containing structures are directly appended to NMC811 active particles, whereas soluble species detected during in situ 1 H and 19 F solution NMR experiments (e.g., alkyl carbonates, HF, and vinyl compounds) are randomly deposited on the composite surface. We show that the combined approach of ex situ SSNMR and XPEEM, in conjunction with in situ solution NMR, allows spatially-resolved, molecular-level characterization of paramagnetic surfaces and new insights into electrolyte oxidation mechanisms in porous electrode films.

36 MATERIALS SCIENCE↗

Using 3D Measurements from MRI to Improve VVUQ

Magnetic resonance velocimetry (MRV) is a diagnostic that can measure 3D, three-component turbulent velocity fields in arbitrarily complex flow configurations. The approach uses magnetic resonance imaging (MRI), which is a system commonly available in radiology departments or medical research centers. MRV acquires signal from hydrogen protons in water channel flows. Despite the obvious utility of the measurements for investigating a variety of flows, comparisons with computational fluid dynamic (CFD) simulations largely retain traditional metrics, comparing velocity profiles and planes at discrete regions within the flow rather than using the 3D nature of the measured field. In this effort, MRV was conducted in a simple water channel with six spanwise-centered periodic obstacles roughly shaped as cubes. At a fully turbulent Reynolds number of 15,000, the channel includes two flows: a main streamwise flow and, in the wake of the second obstacle, an injected flow oriented perpendicular to the streamwise flow. The flow geometry includes partial obstacles on the side walls and is inherently 3D because of the interaction of the two streams and the wake features, making the flow challenging to completely measure with traditional optical techniques. Aside from line profiles and planar comparisons, two 3D metrics are used to compare the data with a steady Reynolds-averaged Navier–Stokes (RANS) simulation result. A brief discussion about the comparison is provided, including comments about uncertainty.

Benson, Mike [ORNL] (ORCID:000000023210116X)↗

Quasi-mode evolution in a stochastic magnetic field

Abstract We present a multi-scale model of quasi-mode evolution in a stochastic magnetic field. The similarity between a quasi-mode and a ballooning mode enables us to address the challenges arising from the disparate geometries in the theories of ballooning modes in the presence of resonant magnetic perturbations. We obtain useful insights into our understanding of ballooning mode dynamics in a stochastic background. To maintain quasi-neutrality at all scales, the beat between the quasi-mode and the stochastic magnetic field drives microturbulence, which drives the turbulent background that promotes mixing and damps the quasi-mode. As a result of the broad mode structure of the quasi-mode, the turbulent viscosity and the turbulent diffusivity produced by the microturbulence are larger than those in our related study on resistive interchange modes. The stochastic magnetic field can also enhance the effective plasma inertia and reduce the effective drive, thereby slowing the mode growth. A nontrivial correlation between the microturbulence and the magnetic perturbations is shown to develop. This could account for the reduction in the Jensen–Shannon complexity of pedestal turbulence in the Resonant Magnetic Perturbation Edge-Localized Mode suppression phase observed in recent experiments. Directions for future experimental and theoretical studies are suggested.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dipole Approximation to Predict the Resonances of Dimers Composed of Dielectric Resonators for Directional Emission: Dielectric Dimers Dipole Approximation

In this paper we develop a fully-retarded, dipole approximation model to estimate the effective polarizabilities of a dimer made of dielectric resonators. They are computed from the polarizabilities of the two resonators composing the dimer. We analyze the situation of full-cubes as well as split-cubes, which have been shown to exhibit overlapping electric and magnetic resonances. We compare the effective dimer polarizabilities to ones retrieved via full-wave simulations as well as ones computed via a quasi-static, dipole approximation. We observe good agreement between the fully-retarded solution and the full-wave results, whereas the quasi-static approximation is less accurate for the problem at hand. The developed model can be used to predict the electric and magnetic resonances of a dimer under parallel or orthogonal (to the dimer axis) excitation. This is particularly helpful when interested in locating frequencies at which the dimer will emit directional radiation.

42 ENGINEERING↗

Sensitivity of Proposed Search for Axion-induced Magnetic Field using Optically Pumped Magnetometers

We investigate the sensitivity of a search for the oscillating current induced by axion dark matter in an external magnetic field using optically pumped magnetometers. This experiment is based upon the LC circuit (circuit with inductor and capacitor) axion detection concept of Sikivie et al. [Phys. Rev. Lett. 112, 131301 (2014)]. The modification of Maxwell’s equations caused by the axion-photon coupling results in a minute magnetic field oscillating at a frequency equal to the axion mass, in the presence of an external magnetic field. The axion-induced magnetic field could be searched for using a LC circuit amplifier with an optically pumped magnetometer, the most sensitive cryogen-free magnetic-field sensor, in a room-temperature experiment, avoiding the need for a complicated and expensive cryogenic system. Here, we discuss how an existing magnetic resonance imaging experiment can be modified to search for axions in a previously unexplored part of the parameter space. Our existing detection setup, optimized for magnetic resonance imagining, is already sensitive to an axion-photon coupling of 10 -7 GeV -1 for an axion mass near 3 × 10 -10 eV, which is already limited by astrophysical processes and solar axion searches. We show that realistic modifications, and optimization of the experiment for axion detection, can probe the axion-photon coupling up to 4 orders of magnitude beyond the current best limit, for axion masses between 10 -1 and 10 -7 eV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Low‐Field Borehole NMR Applications in the Near‐Surface Environment

Core Ideas Low‐field borehole NMR characterizes subsurface heterogeneities from pore to macro scales. Borehole NMR is sensitive to biogeochemical processes and conversions in the subsurface. Development of borehole NMR benefits hydrogeology, soil management, and engineering. The inherent heterogeneity of the near subsurface (<200 m below the ground surface) presents challenges for agricultural water management, hydrogeologic characterization, and engineering, among other fields. Borehole nuclear magnetic resonance (NMR) has the potential not only to describe this heterogeneity in space nondestructively but also to monitor physical and chemical changes in the subsurface with time. Nuclear magnetic resonance is sensitive to parameters of interest like porosity and permeability, saturation, fluid viscosity, and formation mineralogy. Borehole NMR tools have been used to measure soil moisture in model soils, and recent advances in low‐field borehole NMR instrumentation allow estimation of hydraulic properties of unconsolidated aquifers. We also demonstrate the potential for low‐field borehole NMR tools to monitor field‐relevant biogeochemical processes like biofilm accumulation and microbially induced calcite precipitation at laboratory and field scales. Finally, we address some remaining challenges and areas of future research, as well as other possible applications where borehole NMR could provide valuable complementary data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparing deflection measurements of a magnetically steerable catheter using optical imaging and MRI

Purpose: Magnetic resonance imaging (MRI) is an emerging modality for interventional radiology, giving clinicians another tool for minimally invasive image-guided interventional procedures. Difficulties associated with endovascular catheter navigation using MRI guidance led to the development of a magnetically steerable catheter. The focus of this study was to mechanically characterize deflections of two different prototypes of the magnetically steerable catheterin vitro to better understand their efficacy. Methods: A mathematical model for deflection of the magnetically steerable catheter is formulated based on the principle that at equilibrium the mechanical and magnetic torques are equal to each other. Furthermore, two different image based methods for empirically measuring the catheter deflection angle are presented. The first, referred to as the absolute tip method, measures the angle of the line that is tangential to the catheter tip. The second, referred to the base to tip method, is an approximation that is used when it is not possible to measure the angle of the tangent line. Optical images of the catheter deflection are analyzed using the absolute tip method to quantitatively validate the predicted deflections from the mathematical model. Optical images of the catheter deflection are also analyzed using the base to tip method to quantitatively determine the differences between the absolute tip and base to tip methods. Finally, the optical images are compared to MR images using the base to tip method to determine the accuracy of measuring the catheter deflection using MR. Results: The optical catheter deflection angles measured for both catheter prototypes using the absolute tip method fit very well to the mathematical model (R{sup 2} = 0.91 and 0.86 for each prototype, respectively). It was found that the angles measured using the base to tip method were consistently smaller than those measured using the absolute tip method. The deflection angles measured using optical data did not demonstrate a significant difference from the angles measured using MR image data when compared using the base to tip method. Conclusions: This study validates the theoretical description of the magnetically steerable catheter, while also giving insight into different methods and modalities for measuring the deflection angles of the prototype catheters. These results can be used to mechanically model future iterations of the design. Quantifying the difference between the different methods for measuring catheter deflection will be important when making deflection measurements in future studies. Finally, MR images can be used to reliably measure deflection angles since there is no significant difference between the MR and optical measurements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A multi-slot surface coil for MRI of dual-rat imaging at 4T

A slotted surface coil inspired by the hole-and-slot cavity magnetron was developed for magnetic resonance imaging of obese rats at 4 T. Full-wave analysis of the magnetic field was carried out at 170 MHz for both the slotted and circular-shaped coils. The noise figure values of two coils were investigated via the numerical calculation of the quality factors. Fat simulated phantoms to mimic overweight rats were included in the analysis with weights ranging from 300 to 900 g. The noise figures were 1.2 dB for the slotted coil and 2.4 dB for the circular coil when loaded with 600 g of simulated phantom. A slotted surface coil with eight circular slots and a circular coil with similar dimensions were built and operated in the transceiver mode, and their performances were experimentally compared. The imaging tests in phantoms demonstrated that the slotted surface coil has a deeper RF-sensitivity and better field uniformity than the single-loop RF-coil. High quality images of two overweight Zucker rats were acquired simultaneously with the slotted surface coil using standard spin-echo pulse sequences. Experimental results showed that the slotted surface coil outperformed the circular coil for imaging considerably overweight rats. Thus, the slotted surface coil can be a good tool for MRI experiments in rats on a human whole-body 4 T scanner.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

EV Charging Through Wireless Power Transfer: Analysis of Efficiency Optimization and Technology Trends

This paper is aimed at reviewing the technology trends for wireless power transfer (WPT) for electric vehicles (EV). It also analyzes the factors affecting its efficiency and describes the techniques currently used for its optimization. The review of the technology trends encompasses both stationary and moving vehicle charging systems. The study of the stationary vehicle charging technology is based on current implementations and on-going developments at WiTricity and Oak Ridge National Lab (ORNL). The moving vehicle charging technology is primarily described through the results achieved by the Korean Advanced Institute of Technology (KAIST) along with on-going efforts at Stanford University. The factors affecting the efficiency are determined through the analysis of the equivalent circuit of magnetic resonant coupling. The air gap between both transmitting and receiving coils along with the magnetic field distribution and the relative impedance mismatch between the related circuits are the primary factors affecting the WPT efficiency. Currently the industry is looking at an air gap of 25 cm or below. To control the magnetic field distribution, Kaist has recently developed the Shaped Magnetic Field In Resonance (SMFIR) technology that uses conveniently shaped ferrite material to provide low reluctance path. The efficiency can be further increased by means of impedance matching. As a result, Delphi's implementation of the WiTricity's technology exhibits a WPT efficiency above 90% for stationary charging while KAIST has demonstrated a maximum efficiency of 83% for moving vehicle with its On Line Vehicle (OLEV) project. This study is restricted to near-field applications (short and mid-range) and does not address long-range technology such as microwave power transfer that has low efficiency as it is based on radiating electromagnetic waves. This paper exemplifies Delphi's work in powertrain electrification as part of its innovation for the real world program geared toward a safer, greener and more connected driving. Moreover, it draws from and adds to Dr. Andrew Brown Jr.'s SAE books 'Active Safety and the Mobility Industry', 'Connectivity and Mobility Industry', and 'Green Technologies and the Mobility Industry'. Magnetic resonant coupling is the foundation of modern wireless power transfer. Its efficiency can be controlled through impedance matching and magnetic field shaping. Current implementations use one or both of these control methods and enable both stationary and mobile charging with typical efficiency within the 80% and 90% range for an air gap up to 25 cm.

25 ENERGY STORAGE↗

SU-G-JeP2-11: Polymer Gels as 3D QA Devices in Magnetic Resonance-Guided Radiation Therapy

Purpose: To demonstrate the potential of polymer gels to serve as 3D QA devices in MR-guided radiotherapy. Methods: Custom-designed polymer gel dosimeters (MGS Research, Madison, CT) were centered on the penumbras of a radiation field, parallel to the magnetic field lines inside a 1.5 T MR scanner integrated with a 7 MV linac (MR-Linac). 15 Gy were delivered perpendicular to the magnetic field. Coronal MR images were acquired with a 2D balanced-Fast Field Echo (b-FFE) sequence in real-time during irradiation and with a 2D spin echo sequence at different times after irradiation. Signal intensities (SI) were measured inside and outside the radiation field on b-FFE images obtained during irradiation. Spin-spin relaxation rate (R2) maps were calculated from images after irradiation and penumbra widths were calculated from these maps. Results: A difference in SI between areas of the dosimeter inside and outside of the radiation field could be measured immediately after the beam was turned on. The difference in SI increased throughout the duration of the exposure. R2 values from immediately after irradiation were 83% of those measured 24h post-irradiation. At 1h after irradiation, the R2 values were 87% of those at 24h indicating that polymerization of the gel was still ongoing. At 24h postirradiation the width of the 80/20 penumbra on the left field edge measured 6.5 mm and on the right 5.6 mm. Conclusion: The MR-Linac allows for MR imaging during treatment and measurements of 3D dose distributions with steep dose gradients without having to transfer dosimeters for read-out. The results showed promise for polymer gels as relative 3D QA devices to verify radiation treatment plans delivered by an MR-Linac. To our knowledge, this was the first time that polymer gels were used for real-time image acquisition. Further investigations into the application of polymer gel dosimetry on MR-Linac are ongoing.

60 APPLIED LIFE SCIENCES↗

Muon resonance

Availability of polarized muons and ability to detect spin direction - magnetic resonance experiments on muon

MAGNETIC RESONANCE↗

Quantitating Interfraction Target Dynamics During Concurrent Chemoradiation for Glioblastoma: A Prospective Serial Imaging Study

Magnetic resonance image (MRI) guided radiation therapy has the potential to improve outcomes for glioblastoma by adapting to tumor changes during radiation therapy. This study quantifies interfraction dynamics (tumor size, position, and geometry) based on sequential magnetic resonance imaging scans obtained during standard 6-week chemoradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose calculation for permanent prostate implants incorporating spatially anisotropic linearly time-resolving edema

Purpose: The objectives of this study were (i) to develop a dose calculation method for permanent prostate implants that incorporates a clinically motivated model for edema and (ii) to illustrate the use of the method by calculating the preimplant dosimetry error for a reference configuration of {sup 125}I, {sup 103}Pd, and {sup 137}Cs seeds subject to edema-induced motions corresponding to a variety of model parameters. Methods: A model for spatially anisotropic edema that resolves linearly with time was developed based on serial magnetic resonance imaging measurements made previously at our center to characterize the edema for a group of n=40 prostate implant patients [R. S. Sloboda et al., ''Time course of prostatic edema post permanent seed implant determined by magnetic resonance imaging,'' Brachytherapy 9, 354-361 (2010)]. Model parameters consisted of edema magnitude, {Delta}, and period, T. The TG-43 dose calculation formalism for a point source was extended to incorporate the edema model, thus enabling calculation via numerical integration of the cumulative dose around an individual seed in the presence of edema. Using an even power piecewise-continuous polynomial representation for the radial dose function, the cumulative dose was also expressed in closed analytical form. Application of the method was illustrated by calculating the preimplant dosimetry error, RE{sub preplan}, in a 5x5x5 cm{sup 3} volume for {sup 125}I (Oncura 6711), {sup 103}Pd (Theragenics 200), and {sup 131}Cs (IsoRay CS-1) seeds arranged in the Radiological Physics Center test case 2 configuration for a range of edema relative magnitudes ({Delta}=[0.1,0.2,0.4,0.6,1.0]) and periods (T=[28,56,84] d). Results were compared to preimplant dosimetry errors calculated using a variation of the isotropic edema model developed by Chen et al. [''Dosimetric effects of edema in permanent prostate seed implants: A rigorous solution,'' Int. J. Radiat. Oncol., Biol., Phys. 47, 1405-1419 (2000)]. Results: As expected, RE{sub preplan} for our edema model indicated underdosage in the calculation volume with a clear dependence on seed and calculation point positions, and increased with increasing values of {Delta} and T. Values of RE{sub preplan} were generally larger near the ends of the virtual prostate in the RPC phantom compared with more central locations. For edema characteristics similar to the population average values previously measured at our center, i.e., {Delta}=0.2 and T=28 d, mean values of RE{sub preplan} in an axial plane located 1.5 cm from the center of the seed distribution were 8.3% for {sup 131}Cs seeds, 7.5% for {sup 103}Pd seeds, and 2.2% for {sup 125}I seeds. Maximum values of RE{sub preplan} in the same plane were about 1.5 times greater. Note that detailed results strictly apply only for loose seed implants where the seeds are fixed in tissue and move in synchrony with that tissue. Conclusions: A dose calculation method for permanent prostate implants incorporating spatially anisotropic linearly time-resolving edema was developed for which cumulative dose can be written in closed form. The method yields values for RE{sub preplan} that differ from those for spatially isotropic edema. The method is suitable for calculating pre- and postimplant dosimetry correction factors for clinical seed configurations when edema characteristics can be measured or estimated.

60 APPLIED LIFE SCIENCES↗

High elongation elastomers

A new class of liquid curable elastomers with unusual strength and elasticity has been developed at the Naval Air Warfare Center Weapons Division, China Lake. Over the years, studies have been conducted on polymer structure and its influence on the mechanical properties of the ensuing composites. Different tools, including nuclear magnetic resonance, have been used. This paper presents a summary of the factors controlling the mechanical behavior of composites produced with the new liquid curable elastomers, including the effects of plasticizers. It also provides an overview of the nuclear magnetic resonance study on polymer structure, the composition and properties of some live and inert formulations produced at China Lake, and some possible peace-time applications for these new elastomeric materials.

Brady, V. L.↗