Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

The magnetic evolution of the activity complex AR 7260: A roadmap

The active region NOAA 7260 rotated onto the north solar hemisphere as a mature bipole: a dominant negative-polarity sunspot with trailing plage and scattered small spots in attendance. The dominant p spot itself had strong magnetic fields and covered almost 400 x 10(exp -6) of a solar hemisphere. For a period of seven days beginning 14 August, 1992 this active region displayed rapid and drastic evolution: no fewer than 50 magnetic bipoles emerged in the area trailing the large sunspot, increasing the region's magnetic flux by more than 10(exp 22) Mx. This new group of sunspots formed a complex Beta gamma delta configuration with two delta spots and a high degree of magnetic shear. This region was very well observed by Yohkoh and various ground-based instruments. It presented opportunities to study new emerging flux, flares, and also the decay of a large sunspot. For the benefit of later studies we present a description of the global characteristics of this active region, a detailed 'roadmap' of its evolution during disk passage including the development of the two delta regions. We compare proper motion trends and flaring activity to observations of other delta-spots reported in the literature. We also comment on the observed outflow of magnetic elements from the decaying p spot.

Leka, K. D.↗

The R&D of NSLS-II Girder Profiling

A precise state-of-the-art vibrating wire technique will be adopted to achieve the challenging ±30 μm magnet-magnet positioning requirement in NSLS-II storage ring. However, girder profile variation after relocation will merge all the efforts of precise magnet alignment. Girder profiling, a 2-steps process including baseline establishment and restoration in tunnel which never been applied before in accelerator field, will be implemented to keep the girder profile between magnetic measurement room and tunnel as close as possible. Laser tracker is chosen as the main instrument. Tests in environmentally controlled room indicate that a repeatability accuracy of ±10 μm can be achieved by laser tracker in several days period and it has the resolution of better than ±5 μm if serving as an indicator. Simulations and tests prove that an accuracy of better than ±10 μm can be achieved for both steps; therefore, the final magnet-magnet alignment accuracy can be better than ±20 μm. Most of the R&D activities will be presented.

36 MATERIALS SCIENCE↗

Moderately converging ion and electron flows in two-dimensional diodes

Flow of particles in diodes is solved selfconsistently assuming an approximated system of flow lines, that can be easily represented by an analytic transformation in a complex plane, with assumed uniformity in the third spatial direction. Beam current compression is tunable by an angle parameter {alpha}{sub 0}; transformed coordinate lines are circular arcs, exactly matching to the curved cathode usually considered by rectilinear converging flows. The curvature of flow lines allows to partly balance the transverse effect of space charge. A self-contained discussion of the whole theory is reported, ranging from analytical solution for selfconsistent potential to electrode drawing to precise numerical simulation, which serves as a verification and as an illustration of typical electrode shapes. Motion and Poisson equation are written in a curved flow line system and their approximate consistency is shown to imply an ordinary differential equation for the beam edge potential. Transformations of this equation and their series solutions are given and discussed, showing that beam edge potential has a maximum, so supporting both diode (with {alpha}{sub 0}{approx_equal}{pi}/3) and triode design. Numerical simulations confirm the consistency of these solution. Geometrical details of diode design are discussed: the condition of a zero divergence beam, with the necessary anode lens effect included, is written and solved, as a function of beam compression; accurate relations for diode parameters and perveance are given. Weakly relativistic effects including self-magnetic field are finally discussed as a refinement.

43 PARTICLE ACCELERATORS↗

A high-resolution imaging x-ray crystal spectrometer for high energy density plasmas

Adapting a concept developed for magnetic confinement fusion experiments, an imaging crystal spectrometer has been designed and tested for HED plasmas. The instrument uses a spherically bent quartz [211] crystal with radius of curvature of 490.8 mm. The instrument was tested at the Titan laser at Lawrence Livermore National Laboratory by irradiating titanium slabs with laser intensities of 10{sup 19}–10{sup 20} W/cm{sup 2}. He-like and Li-like Ti lines were recorded, from which the spectrometer performance was evaluated. This spectrometer provides very high spectral resolving power (E/dE > 7000) while acquiring a one-dimensional image of the source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ulysses Launch

Ulysses is a joint mission between the United States National Aeronautics and Space Administration (NASA) and the European Space Agency (ESA) to explore the heliosphere over the full range of solar latitudes, especially in the polar regions. The goal of the Ulysses mission is to provide an accurate assessment of our total solar environment. This collaborative ESA/NASA mission will, for the first time, explore the heliosphere -- the region of space that is dominated by the Sun-- within a few astronomical units of the Sun over the full range of heliographic latitudes. The path followed by the spacecraft, using a Jupiter gravity-assist to achieve a trajectory extending to high solar latitudes, will enable the highly sophisticated scientific instruments on board to make measurements in the uncharted third dimension of the heliosphere. The Ulysses spacecraft will carry nine scientific instruments to measure the properties of the solar corona, the solar wind, the Sun/wind interface, the heliospheric magnetic field, solar radio bursts, plasma waves, solar X-rays, solar and galactic cosmic rays, and the interplanetary/interstellar neutral gas and dust. Scientists will take advantage of the enormous distance between the spacecraft and the Earth to perform astrophysical measurements and to search for gravitational waves. In conjunction with instrumentation on Earth-orbiting spacecraft, Ulysses will help to precisely locate the mysterious sources of cosmic gamma bursts. The results obtained will help to solve outstanding problems in solar and heliospheric physics, while undoubtedly revealing new and unanticipated phenomena.

Source record↗

Phase space variations of near equatorially mirroring ring current ions

Observations of near equatorially mirroring ring current ions before and after a magnetic storm are presented in the form of phase space densities with respect to the first adiabatic invariant. Particle densities were obtained from the medium energy particles instrument covering the energy range 24-2081 keV on ISEE 1 at L values between 3 and 8 earth radii and ratios of the magnetic field at the satellite position to the magnetic field at the magnetic equator less than 1.2. Analysis of the phase space densities through the magnetosphere reveals a well-defined high magnetic moment peak in the prestorm near-equatorial ring current ion phase space density distribution, with the magnetic storm resulting from an enhancement of phase space densities at magnetic moment values below the peak and phase space densities remaining constant above the peak. Results are found to be in good agreement with those obtained by Explorer 45 six years previously, indicating that the observed phase space density variations are characteristic of energetic ion behavior during magnetic storms.

Williams, D. J.↗

Measurement of the angle dependence of magnetostriction in pulsed magnetic fields using a piezoelectric strain gauge

In this paper, we present a high resolution method for measuring magnetostriction in millisecond pulsed magnetic fields at cryogenic temperatures with a sensitivity of 1.11×10 -11 /√Hz. The sample is bonded to a thin piezoelectric plate such that when the sample’s length changes, it strains the piezoelectric and induces a voltage change. This method is more sensitive than a fiber-Bragg grating method. It measures two axes simultaneously instead of one. The gauge is small and versatile, functioning in DC and millisecond pulsed magnetic fields. We demonstrate its use by measuring the magnetostriction of Ca 3 Co 1.03 Mn 0.97 O 6 single crystals in pulsed magnetic fields. By comparing our data to new and previously published results from a fiber-Bragg grating magnetostriction setup, we confirm that this method detects magnetostriction effects. Lastly, we also demonstrate the small size and versatility of this technique by measuring angle dependence with respect to the applied magnetic field in a rotator probe in 65 T millisecond pulsed magnetic fields.

36 MATERIALS SCIENCE↗

Multicolor Variability of Young Stars in the Lagoon Nebula: Driving Causes and Intrinsic Timescales

Space observatories have provided unprecedented depictions of the many variability behaviors typical of low-mass, young stars. However, those studies have so far largely omitted more massive objects (~2 M {sub ⊙} to 4–5 M {sub ⊙}) and were limited by the absence of simultaneous, multiwavelength information. We present a new study of young star variability in the ~1–2 Myr old, massive Lagoon Nebula region. Our sample encompasses 278 young, late B to K-type stars, monitored with Kepler/K2. Auxiliary u, g, r, i, Hα time-series photometry, simultaneous with K2, was acquired at the Paranal Observatory. We employed this comprehensive data set and archival infrared photometry to determine individual stellar parameters, assess the presence of circumstellar disks, and tie the variability behaviors to inner disk dynamics. We found significant mass-dependent trends in variability properties, with B/A stars displaying substantially reduced levels of variability compared to G/K stars for any light-curve morphology. These properties suggest different magnetic field structures at the surface of early-type and later-type stars. We also detected a dearth of some disk-driven variability behaviors, particularly dippers, among stars earlier than G. This indicates that their higher surface temperatures and more chaotic magnetic fields prevent the formation and survival of inner disk dust structures corotating with the star. Finally, we examined the characteristic variability timescales within each light curve and determined that the day-to-week timescales are predominant over the K2 time series. These reflect distinct processes and locations in the inner disk environment, from intense accretion triggered by instabilities in the innermost disk regions to variable accretion efficiency in the outer magnetosphere.

47 OTHER INSTRUMENTATION↗

Lunar surface solar wind observations at the Apollo 12 and Apollo 15 sites

The solar wind-lunar magnetic field interaction is examined by comparing Apollo 12 and Apollo 15 solar wind spectrometric data. The instrumentation and data analysis methods are described along with the observations at the Apollo 15 site, and the data from the two sites are compared. The results show no noticeable differences between the properties of the upstream solar wind and the plasma observed at the Apollo 15 site (where the local magnetic field is relatively weak) and strong perturbations in the solar wind at the Apollo 12 site (where the field is relatively strong), which include deceleration, deflection, and heating of solar wind protons, focusing or defocusing of the ion flux, and an increased level of plasma parameter fluctuations. These effects are shown to require a charge-separated electric field above the lunar surface and a scale size of about 5 km for the local magnetic field at the Apollo 12 site and to suggest that local lunar magnetic field regions cause lunar limb compression waves which should be more noticeable for low solar wind dynamic pressures.

Clay, D. R.↗

PAMELA’S MEASUREMENTS OF MAGNETOSPHERIC EFFECTS ON HIGH-ENERGY SOLAR PARTICLES

The nature of particle acceleration at the Sun, whether through flare reconnection processes or through shocks driven by coronal mass ejections, is still under scrutiny despite decades of research. The measured properties of solar energetic particles (SEPs) have long been modeled in different particle-acceleration scenarios. The challenge has been to disentangle the effects of transport from those of acceleration. The Payload for Antimatter Matter Exploration and Light-nuclei Astrophysics (PAMELA) instrument enables unique observations of SEPs including the composition and angular distribution of the particles about the magnetic field, i.e., pitch angle distribution, over a broad energy range (>80 MeV)—bridging a critical gap between space-based and ground-based measurements. We present high-energy SEP data from PAMELA acquired during the 2012 May 17 SEP event. These data exhibit differential anisotropies and thus transport features over the instrument rigidity range. SEP protons exhibit two distinct pitch angle distributions: a low-energy population that extends to 90° and a population that is beamed at high energies (>1 GeV), consistent with neutron monitor measurements. To explain a low-energy SEP population that exhibits significant scattering or redistribution accompanied by a high-energy population that reaches the Earth relatively unaffected by dispersive transport effects, we postulate that the scattering or redistribution takes place locally. We believe that these are the first comprehensive measurements of the effects of solar energetic particle transport in the Earth’s magnetosheath.

79 ASTRONOMY AND ASTROPHYSICS↗

In vivo nuclear magnetic resonance imaging

During the past year the Woodlands Baylor Magnetic Resonance Imaging (MRI) facility became fully operational. A detailed description of this facility is given. One significant instrument addition this year was the 100 MHz, 40cm bore superconducting imaging spectrometer. This instrument gives researchers the capability to acquire high energy phosphate spectra. This will be used to investigate ATP, phosphocreatinine and inorganic phosphate changes in normal and atrophied muscle before, during and after exercise. An exercise device for use within the bore of the imaging magnet is under design/construction. The results of a study of T sub 1 and T sub 2 changes in atrophied muscle in animals and human subjects are given. The imaging and analysis of the lower leg of 15 research subjects before and after 5 weeks of complete bedrest was completed. A compilation of these results are attached.

Leblanc, A.↗

High resolution detection and excitation of resonant magnetic perturbations in a wall-stabilized tokamak

We report high-resolution detection of the 3D plasma magnetic response of wall-stabilized tokamak discharges in the High Beta Tokamak-Extended Pulse [T. H. Ivers et al., Phys. Plasmas 3, 1926 (1996)] device. A new adjustable conducting wall has been installed on HBT-EP made up of 20 independent, movable, wall segments instrumented with three distinct sets of 40 modular coils that can be independently driven to generate a wide variety of magnetic perturbations. High-resolution detection of the plasma response is made with 216 poloidal and radial magnetic sensors that have been located and calibrated with high-accuracy. Static and dynamic plasma responses to resonant and non-resonant magnetic perturbations are observed through measurement of the step-response following a rapid change in the toroidal phase of the applied perturbations. Biorthogonal decomposition of the full set of magnetic sensors clearly defines the structures of naturally occurring external kinks as being composed of independent m/n = 3/1 and 6/2 modes. Resonant magnetic perturbations were applied to discharges with pre-existing, saturated m/n = 3/1 external kink mode activity. This m/n = 3/1 kink mode was observed to lock to the applied perturbation field. During this kink mode locked period, the plasma resonant response is characterized by a linear, a saturated, and a disruptive plasma regime dependent on the magnitude of the applied field and value of the edge safety factor and plasma rotation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Scattering in High Magnetic Fields: Community Recommendations to Seize the Moment for Scientific Breakthroughs

Oak Ridge National Laboratory (ORNL) operates the world’s two most powerful neutron sources: the High Flux Isotope Reactor (HFIR) and the Spallation Neutron Source (SNS). These form a national user facility that provides neutron scattering instruments to probe and image static and dynamic properties of materials down to the atomic scale. Because the neutron carries a magnetic moment and the energies and wavelengths of neutrons match energy and length scales associated with magnetic materials, these facilities provide unique sensitivity to magnetism.

36 MATERIALS SCIENCE↗

A Novel $In-Situ$ Radiation Damage Diagnostic System for Undulators

Radiation damage has been a known problem at many synchrotron radiations and free-electron lasers facilities, especially those that use hybrid or pure permanent magnet undulators to produce high brightness light. Field strength loss due to demagnetization makes it necessary to remove the insertion device from the tunnel for inspection and repair, which brings several inconveniences. We aimed to develop an in situ radiation damage detection system for undulators capable of diagnosing relative field changes of 10 -4 (100 ppm) or smaller. The system measures the flux change in a flexible printed circuit board coil attached to the undulator magnet array by periodically measuring the integral flux change during the opening and closing of the undulator gap. If the magnet block damage occurs, the signal from the coil will decrease proportionally to the damage. First tests performed on variable gap hybrid undulators for the Linac Coherent Light Source II (LCLS-II) at SLAC National Accelerator Laboratory showed that the system is capable of measuring flux changes with a relative precision of approximately 0.7 × 10 -4 over several days. Relative field changes smaller than 10 -4 were detected in short-term measurements. Here, the novel system that we propose here opens the possibility of detecting radiation damage in undulators during operation.

47 OTHER INSTRUMENTATION↗

A sample holder with integrated laser optics for an ELMITEC photoemission electron microscope

We present a new sample holder compatible with ELMITEC Photoemission Electron Microscopes (PEEMs) containing an optical lens and a mirror. With the integrated optical elements, a laser beam is focused from the back side of the sample at normal incidence, yielding a minimum spot size of about 1 μm. This opens up new possibilities for local laser excitations in PEEM experiments such as imaging all-optical magnetization switching at a small length scale.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automated setup for magnetic hysteresis characterization based on a voltage controlled current source with 500 kHz full power bandwidth and 10 A peak-to-peak current

This paper describes the design of a system for the characterization of magnetic hysteresis behavior in soft ferrite magnetic cores. The proposed setup can test magnetic materials exciting them with controlled arbitrary magnetic field waveforms, including the capability of providing a DC bias, in a frequency bandwidth up to 500 kHz, with voltages up to 32 V peak-to-peak, and currents up to 10 A peak-to-peak. In order to have an accurate control of the magnetic field waveform, the system is based on a voltage controlled current source. The electronic design is described focusing on closed loop feedback stabilization and passive components choice. The system has real-time hysteretic loop acquisition and visualization. The comparisons between measured hysteresis loops of sample magnetic materials and datasheet available ones are shown. Results showing frequency and thermal behavior of the hysteresis of a test sample prove the system capabilities. Moreover, the B-H loops obtained with a multiple waveforms excitation signal, including DC bias, are reported. The proposal is a low-cost and replicable solution for hysteresis characterization of magnetic materials used in power electronics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Surges as tracers of magnetic lines

During the maximum activity year 1980, chromospheric mass ejections were observed with the Multichannel Subtractive Double Pass Spectrograph operating at Meudon (MSDP), while the UV and X-ray emissions were observed respectively with the UV Spectrograph (UVSP) and HXIS instruments on the SMM satellite. These ejections are not related directly to flares but are located in active regions near sunspots. As the magnetic field is frozen in the matter, the study of the velocity field leads to the geometry of the magnetic structures and the temporal evolution of the magnetic-field lines. Ejections of matter recur often with a period of 10 to 20 minutes. In C IV, the bright loops coincide with the H-alpha surge but are more extended. Associated with the events are either X-ray emission or type-III bursts.

Schmieder, B.↗

Correcting aberrations of a transverse-field neutron resonance spin echo instrument

Neutron resonance spin echo (NRSE) technique has the potential to increase the Fourier time and energy resolution in neutron scattering by using radio frequency (rf) neutron spin-flippers. However, aberrations arising from variations in the neutron path length between the rf flippers reduce the polarization. Here, we develop and test a transverse static-field magnet, a series of which are placed between the rf flippers, to correct for these aberrations. The prototype correction magnet was both simulated in an NRSE beamline using McStas, a Monte Carlo neutron ray-tracing software package, and measured using neutrons. The results from the prototype demonstrate that this static-field design corrects for transverse-field NRSE aberrations.

47 OTHER INSTRUMENTATION↗