At least 1,189 records · Page 66

In‐memory integration of existing software components for parallel adaptive unstructured mesh workflows

Summary Reliable mesh‐based simulations are needed to solve complex engineering problems. Mesh adaptivity can increase reliability by reducing discretization errors but requires multiple software components to exchange information. Often, components exchange information by reading and writing a common file format. This file‐based approach becomes a problem on massively parallel computers where filesystem bandwidth is a critical performance bottleneck. Our approach using data streams and component interfaces avoids the filesystem bottleneck. In this paper, we present these techniques and their use for coupling mesh adaptivity to the PHASTA computational fluid dynamics solver, the Albany multi‐physics framework, and the Omega3P linear accelerator frequency analysis applications. Performance results are reported on up to 16,384 cores of an Intel Knights Landing‐based system.

Smith, Cameron W.↗

Bayesian optimization to design a novel x-ray shaping device

In radiation therapy, x-ray dose must be precisely sculpted to the tumor, while simultaneously avoiding surrounding organs at risk. This requires modulation of x-ray intensity in space and/or time. Typically, this is achieved using a multi leaf collimator (MLC) - a complex mechatronic device comprising over one hundred individually powered tungsten ‘leaves’ that move in or out of the radiation field as required. Here, an all-electronic x-ray collimation concept with no moving parts is presented, termed “SPHINX”: Scanning Pencil-beam High-speed Intensity-modulated X-ray source. SPHINX utilizes a spatially distributed bremsstrahlung target and collimator array in conjunction with magnetic scanning of a high energy electron beam to generate a plurality of small x-ray “beamlets.” A simulation framework was developed in Topas Monte Carlo incorporating a phase space electron source, transport through user defined magnetic fields, bremsstrahlung x-ray production, transport through a SPHINX collimator, and dose in water. This framework was completely parametric, meaning a simulation could be built and run for any supplied geometric parameters. This functionality was coupled with Bayesian optimization to find the best parameter set based on an objective function which included terms to maximize dose rate for a user defined beamlet width while constraining inter-channel cross talk and electron contamination. Designs for beamlet widths of 5, 7, and 10 mm 2 were generated. Each optimization was run for 300 iterations and took approximately 40 h on a 24-core computer. For the optimized 7-mm model, a simulation of all beamlets in water was carried out including a linear scanning magnet calibration simulation. Finally, a back-of-envelope dose rate formalism was developed and used to estimate dose rate under various conditions. The optimized 5–, 7–, and 10-mm models had beamlet widths of 5.1 , 7.2 , and 10.1 mm 2 and dose rates of 3574, 6351, and 10 015 Gy/C, respectively. The reduction in dose rate for smaller beamlet widths is a result of both increased collimation and source occlusion. For the simulation of all beamlets in water, the scanning magnet calibration reduced the offset between the collimator channels and beam centroids from 2.9 ±1.9 mm to 0.01 ±0.03 mm. A slight reduction in dose rate of approximately 2% per degree of scanning angle was observed. Based on a back-of-envelope dose rate formalism, SPHINX in conjunction with next-generation linear accelerators has the potential to achieve substantially higher dose rates than conventional MLC-based delivery, with delivery of an intensity modulated 100 x 100 mm 2 field achievable in 0.9 to 10.6 s depending on the beamlet widths used. Bayesian optimization was coupled with Monte Carlo modeling to generate SPHINX geometries for various beamlet widths. A complete Monte Carlo simulation for one of these designs was developed, including electron beam transport of all beamlets through scanning magnets, x-ray production and collimation, and dose in water. These results demonstrate that SPHINX is a promising candidate for sculpting radiation dose with no moving parts, and has the potential to vastly improve both the speed and robustness of radiotherapy delivery. A multi-beam SPHINX system may be a candidate for delivering magavoltage FLASH RT in humans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Non-linear Wire Rope Isolator Model to Enhance Transportation Simulation of Fragile Equipment

Abstract Introduction Wire rope isolators are often used as means of vibration isolation for the transportation of fragile machine equipment. When deployed as suspension systems in a transportation scenario, a simple spring–damper model is often used to predict the dynamic loads that act on the structure being transported. However, this simple model has proved to be too simplistic to be used in the development of an accurate numerical model that can predict the vibration levels experienced by the inner components of fragile equipment during its transportation. This paper describes the experimental tests conducted on a wire rope isolator used for the transportation of the prototype SSR1 cryomodule. Materials and methods A hysteretic Bouc–Wen model has been used to analytically describe the force–deformation relationship of the wire rope isolators. The developed model of the isolator has been implemented in a larger model to simulate the actual transportation of the prototype SSR1 cryomodule, a section of the new PIP-II linear accelerator under construction at Fermilab. A series of multibody dynamic simulations with rigid and flexible components was used to numerically determine the acceleration of some critical components. Results and conclusions An actual experimental transportation was simulated using two numerical models: the developed Bouc–Wen model and a conventional spring–damper model. It is shown how the Bouc–Wen formulation of the isolator characteristics drastically improves the correspondence between experimental and simulated results if compared to a spring–damper model, especially in the range of 0–30 Hz which is the most critical for transportation problems.

42 ENGINEERING↗

Extending the length and time scales of Gram–Schmidt Lyapunov vector computations

Lyapunov vectors have found growing interest recently due to their ability to characterize systems out of thermodynamic equilibrium. The computation of orthogonal Gram–Schmidt vectors requires multiplication and QR decomposition of large matrices, which grow as N{sup 2} (with the particle count). This expense has limited such calculations to relatively small systems and short time scales. Here, we detail two implementations of an algorithm for computing Gram–Schmidt vectors. The first is a distributed-memory message-passing method using Scalapack. The second uses the newly-released MAGMA library for GPUs. We compare the performance of both codes for Lennard–Jones fluids from N=100 to 1300 between Intel Nahalem/Infiniband DDR and NVIDIA C2050 architectures. To our best knowledge, these are the largest systems for which the Gram–Schmidt Lyapunov vectors have been computed, and the first time their calculation has been GPU-accelerated. We conclude that Lyapunov vector calculations can be significantly extended in length and time by leveraging the power of GPU-accelerated linear algebra.

97 MATHEMATICS AND COMPUTING↗

Beam dynamics performances and applications of a low-energy electron-beam magnetic bunch compressor

Many front-end applications of electron linear accelerators rely on the production of temporally compressed bunches. The shortening of electron bunches is often realized with magnetic bunch compressors located in high-energy sections of accelerators. Magnetic compression is subject to collective effects including space charge and self interaction via coherent synchrotron radiation. In this paper we explore the application of magnetic compression to low-energy (~40MeV), high-charge (nC) electron bunches with low normalized transverse emittances (<5@mm).

43 PARTICLE ACCELERATORS↗

Compact Spreader Schemes

This paper describes beam distribution schemes adopting a novel implementation based on low amplitude vertical deflections combined with horizontal ones generated by Lambertson-type septum magnets. This scheme offers substantial compactness in the longitudinal layouts of the beam lines and increased flexibility for beam delivery of multiple beam lines on a shot-to-shot basis. Fast kickers (FK) or transverse electric field RF Deflectors (RFD) provide the low amplitude deflections. Initially proposed at the Stanford Linear Accelerator Center (SLAC) as tools for beam diagnostics and more recently adopted for multiline beam pattern schemes, RFDs offer repetition capabilities and a likely better amplitude reproducibility when compared to FKs, which, in turn, offer more modest financial involvements both in construction and operation. Both solutions represent an ideal approach for the design of compact beam distribution systems resulting in space and cost savings while preserving flexibility and beam quality.

43 PARTICLE ACCELERATORS↗

A method to measure prompt fission neutron spectrum using gamma multiplicity tagging

In order to improve on current prompt fission neutron spectrum measurements, a gamma multiplicity tagging method was developed at the Rensselaer Polytechnic Institute Gearttner Linear Accelerator Center. This method involves using a coincidence requirement on an array of BaF 2 gamma detectors to determine the timing of a fission event. This allows for much larger fission samples to be used due to the higher penetrability of gammas compared to fission fragments. Additionally, since the method relies on gammas as opposed to fission fragments, the effects of the low level discriminator, used in fission chambers to eliminate alpha events, are not seen. A 252 Cf fission chamber was constructed in order to determine the viability of this method as well as the efficiency when compared to a fission chamber. The implemented multiple gamma tagging method was found to accurately reproduce the prompt fission neutron spectrum for the spontaneous fission of 252 Cf and to detect 30% of fission events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel design and diagnostics improvements for increased production capacity and improved reliability at the Los Alamos Isotope Production Facility

The Isotope Production Facility (IPF) at Los Alamos National Laboratory (LANL) is used to produce an array of isotopes for medical, global security, and research applications with an intense beam of protons supplied by the linear accelerator at the Los Alamos Neutron Science Center (LANSCE). An Accelerator Improvement Project (AIP) was recently conducted at IPF to improve facility reliability and reduce programmatic risk while increasing general isotope production capacity and flexibility. This was accomplished through the installation of an improved beam window assembly, more robust beam diagnostics, an active and adjustable collimator, and a new beam rastering system. This paper will highlight the four exciting innovations and how they were designed, validated, and installed in parallel as well as the significant operational advantages they provide to IPF. Key experiments and the increased currents achieved in routine production runs demonstrating the enhanced capability from the AIP will be presented. As a result, the most notable capability enhancements include irradiations with beam currents ranging from 100 nA experimental runs up to 300 μA on routine production targets and utilization of a range of cylindrical target diameters.

100 MeV protons↗

Clinical 6 MV X-Ray Facility Photo-Neutron/Fission Interrogations with TMFD Sensors

Detection of several targets (U, Be, D2O) of interest to national security has been achieved at Purdue University’s 6 MV (~104 R/h) X-Ray clinical linear accelerator (CLINAC), from photoneutron/fission induced neutron signatures using a Centrifugally Tensioned Metastable Fluid Detector (CTMFD). Traditional neutron detection schemes were saturated and ineffective under the intense (to ~104 R/h) photon environment; however, the CTMFD sensor technology was capable of measuring the relatively insignificant (~10-12x lower intensity) neutron field produced from 6 MeV-end point X-Ray beam interactions with the CLINAC components and surroundings. This is in stark contrast to published results based on conventional belief for immeasurable neutron dose in 6 MV CLINAC facilities. Photoneutron and photofission neutron production rates were detected and analyzed at various standoffs from the isocenter, with and without special nuclear material (SNM) related targets ranging in mass from 5 g of Be, to ~0.6 kg of UO2. It was confirmed that 6 MV X-Ray photons do result in measurable neutron dose above normal cosmic background. Additionally, in threshold mode, the CTMFD operating under a tensioned metastable pressure of -5bar, enabled conclusive rejection of background photoneutrons, while enabling the rapid detection of: Be, D2O, C and U targets within seconds to minutes while operating in and around 104 R/h photon fields.

Ozerov, Stepan↗

In-flight production of an isomeric beam of 16 N

In this work, an in-flight beam of 16 N was produced via the single-neutron adding ($\textit{d,p}$) reaction in inverse kinematics at the recently upgraded Argonne Tandem Linear Accelerator System (ATLAS) in-flight system. The amount of the 16 N beam which resided in its excited 0.120 MeV $J^\pi$ = 0 – isomeric state (T 1/2 ≈ 5 μs) was determined to be 40(5)% at a reaction energy of 7.9(3) MeV/$\textit{u}$, and 24(2)% at a reaction energy of 13.2(2) MeV/$\textit{u}$. The isomer measurements took place at an experimental station ≈ 30 m downstream of the production target and utilized an Al beam-stopping foil and a HPGe Clover detector. Composite 16 N beam rate determinations were made at the experimental station and the focal plane of the Argonne in-flight radioactive ion-beam separator (RAISOR) with Si ΔE-E telescopes. A Distorted Wave Born Approximation (DWBA) approach was coupled with the known spectroscopic information on 16 N in order to estimate the relative 16 N isomer yields and composite 16 N beam rates. In addition to the observed reaction-energy dependence of the isomer fraction, a large sensitivity to the angular acceptance of the recoils was also observed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design and commissioning of an e-beam irradiation beamline at the Upgraded Injector Test Facility at Jefferson Lab

We report the Upgraded Injector Test Facility (UITF) at Jefferson Lab is a continuous-wave superconducting linear accelerator capable of providing an electron beam with energy up to 10 MeV. A beamline for electron-beam irradiation has been designed, installed and successfully commissioned at this facility, aimed at the degradation study of 1,4-dioxane and per- and polyfluoroalkyl substances (PFAS) in wastewater treatment. A solenoid with a peak axial magnetic field of up to 0.28 T and a set of raster coils were used to obtain a Gaussian beam profile with a transverse standard deviation of ~ 15.0 mm at the target location. Monte-Carlo simulations using FLUKA were carried out to calculate the total absorbed dose and the dose distribution in the sample volume inside the target cell. The simulations were benchmarked experimentally by dosimetry mapping using optichromic dosimeters. The results of the irradiation experiments showed a ~ 95% reduction of 1,4-dioxane in ultra-pure water for a dose of 1 kGy, demonstrating the potential of electron-beam irradiation towards addressing growing challenges in environmental remediation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam dynamics in independent phased cavities

Linear accelerators containing the sequence of independently phased cavities with constant geometrical velocity along each structure are widely used in practice. The chain of cavities with identical cell lengths is utilized within a certain beam velocity range, with subsequent transformation to the next chain with higher cavity velocity. Design and analysis of beam dynamics in this type of accelerator are usually performed using numerical simulations. A full theoretical description of particle acceleration in an array of independent phased cavities has not been developed. In the present paper, we provide an analytical treatment of beam dynamics in such linacs employing Hamiltonian formalism. We begin our analysis with an examination of beam dynamics in an equivalent traveling wave of a single cavity, propagating within accelerating section with constant phase velocity. We then consider beam dynamics in arrays of cavities, utilizing an effective traveling wave propagating along with the whole accelerator with the velocity of synchronous (reference) particle. The analysis concluded with the determination of the matched beam conditions. Finally, we present a beam dynamics study in 805 MHz Coupled Cavity Linac of the LANSCE accelerator facility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The CeBrA demonstrator for particle-γ coincidence experiments at the FSU Super-Enge Split-Pole Spectrograph

We report on a highly selective experimental setup for particle-γ coincidence experiments at the Super-Enge Split-Pole Spectrograph (SE-SPS) of the John D. Fox Superconducting Linear Accelerator Laboratory at Florida State University (FSU) using fast CeBr scintillators for γ-ray detection. Specifically, we report on the results of characterization tests for the first five CeBr 3 scintillation detectors of the CeBr 3 Array (CeBrA) with respect to energy resolution and timing characteristics. We also present results from the first particle-γ coincidence experiments successfully performed with the CeBrA demonstrator and the FSU SE-SPS. We show that with the new setup, γ-decay branching ratios and particle-γ angular correlations can be measured very selectively using narrow excitation energy gates, which are possible thanks to the excellent particle energy resolution of the SE-SPS. In addition, we highlight that nuclear level lifetimes in the nanoseconds regime can be determined by measuring the time difference between particle detection with the SE-SPS focal-plane scintillator and γ-ray detection with the fast CeBrA detectors. As a result, selective excitation energy gates with the SE-SPS exclude any feeding contributions to these lifetimes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental design of a W-band corrugated waveguide for wakefield acceleration studies

Radiofrequency (RF) structures in the sub-terahertz (sub-THz) regime are of interest for applications in structure wakefield acceleration due to their compact size and potential for high gradients. Here, we present the design, fabrication, and experimental setup of a metallic corrugated waveguide at 110 GHz, optimized for the 42 MeV electron beam parameters at the Argonne Wakefield Accelerator (AWA). The emittance exchange (EEX) beamline at AWA was used to perform longitudinal bunch shaping for two cases: (1) a high decelerating gradient experienced by a single drive electron bunch about 250 μm long; (2) a high transformer ratio using a two-bunch train consisting of a triangularly shaped drive bunch followed by a long witness bunch to probe the wakefield. Preliminary experimental results are presented, and data analysis is ongoing.

43 PARTICLE ACCELERATORS↗

Design and fabrication of a four-rod radio frequency quadrupole with a variable aperture

Radiofrequency quadrupole (RFQ) linear accelerators with variable aperture cell parameters offer an effective means of accelerating high-intensity ion beams exceeding 100 mA and have been implemented in various RFQ designs. However, in a four-rod RFQ, the use of dielectric perturbation methods to measure the voltage distribution behind the rod electrodes is not applicable when implementing variable aperture geometries, because changes in the rod shape influence the electric field at the location of the perturbation element. Therefore, it was necessary to design the rod profile for each cell such that the electric field distribution behind the rods remains unaffected by changes in the aperture. In this study, we present a method to adjust the voltage distribution by modifying the geometry of the rod electrodes according to each cell's aperture parameters. This design approach enables the integration of variable aperture cells into a four-rod RFQ linac, significantly enhancing the achievable beam current. To ensure uniform capacitance and maintain a constant rod-electrode voltage despite variations in the average aperture radius, we developed a systematic method for shaping the rod electrodes. This method was refined using two-dimensional (2D) and three-dimensional (3D) electromagnetic field simulations to optimize the electrode cross-sectional profiles. The fabricated rod electrodes were then installed in a four-rod RFQ, and the electric field distribution was measured using the perturbation method and tuned by adjusting the base plates. As a result, the measured variation of ±1.1 % confirms that this design methodology can produce a sufficiently uniform voltage distribution for high-current beam acceleration. These results demonstrate the practical feasibility of a variable-aperture four-rod RFQ linac.

43 PARTICLE ACCELERATORS↗

Commissioning of the Advanced Rare Isotope Separator ARIS at FRIB

The Facility for Rare Isotope Beams (FRIB) at Michigan State University (MSU) consists of a newly constructed linear accelerator and fragment separator that are designed for enhanced production rates of rare isotopes for use in research and other societal applications. Recent activities through to August 2022 took place to commission the Advanced Rare Isotope Separator (ARIS) and carry out the first experiments. This followed commissioning of the newly constructed linac that is designed to provide orders of magnitude higher beam power than the previously coupled cyclotrons. This required that more advanced target, beam dump, and collimation systems of the new separator be designed and constructed to sustain unprecedented conditions by heavy ion beams. Commissioning with ~1 kW beams began recently and results from activities that began in late 2021 are reported here. Comparisons between the previous and current facilities are provided.

43 PARTICLE ACCELERATORS↗

The new Batch Mode Ion Source for stand-alone operation at the Facility for Rare Isotope Beams (FRIB)

Gas stoppers have been used for a long-standing successful science program at Michigan State University with stopped and rare-isotope beams produced by projectile fragmentation. The National Superconducting Cyclotron Laboratory’s Coupled Cyclotron Facility has recently transitioned into the Facility for Rare Isotope Beams (FRIB) laboratory to provide rare isotopes using a high-power superconducting linear accelerator and new production facilities. To allow the science program with stopped and reaccelerated beams to continue during the transition period, a stand-alone capability was added. The Batch Mode Ion Source (BMIS) was built and has been providing beams of long-lived and stable isotopes of a variety of elements for successful user experiments. Finally, the BMIS system is described and results from the production of various beams are presented.

47 OTHER INSTRUMENTATION↗

Measurements of excitation functions and photoneutron cross sections of 96,98,99,104 Ru and 100 Mo

Photoneutron cross sections were extracted for isotopes of ruthenium and molybdenum on natural abundance targets via a reduced chi-squared analysis on excitation functions, or activation yields, as function of electron beam energy. Bremsstrahlung photons were produced via an electron linear accelerator and a tungsten radiator at the Idaho Accelerator Center. A total of 16 irradiations were performed with electron beam energies ranging from approximately 8 MeV to 23 MeV. Induced radioactivity was measured using a high purity germanium detector. The cross sections were extracted assuming a three parameter Lorentzian fit with a smooth truncated rise at reaction threshold.

07 - ISOTOPES AND RADIATION SOURCES↗