Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LAT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

High Energy Neutrinos from the Fermi Bubbles

Recently the Fermi-LAT data have revealed two gamma-ray emitting bubble-shaped structures at the Galactic center. If the observed gamma rays have hadronic origin (collisions of accelerated protons), the bubbles must emit high energy neutrinos as well. This new, Galactic, neutrino flux should trace the gamma-ray emission in spectrum and spatial extent. Its highest energy part, above 20–50 TeV, is observable at a kilometer-scale detector in the northern hemisphere, such as the planned KM3NeT, while interesting constraints on it could be obtained by the IceCube Neutrino Observatory at the South Pole. The detection or exclusion of neutrinos from the Fermi bubbles will discriminate between hadronic and leptonic models, thus bringing unique information on the still mysterious origin of these objects and on the time scale of their formation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Resolving the Extragalactic γ -Ray Background above 50 GeV with the Fermi Large Area Telescope

The Fermi Large Area Telescope (LAT) Collaboration has recently released a catalog of 360 sources detected above 50 GeV (2FHL). This catalog was obtained using 80 months of data re-processed with Pass 8, the newest event-level analysis, which significantly improves the acceptance and angular resolution of the instrument. Most of the 2FHL sources at high Galactic latitude are blazars. In this paper, using detailed Monte Carlo simulations, we measure, for the first time, the source count distribution, dN/dS, of extragalactic γ-ray sources at E > 50 GeV and find that it is compatible with a Euclidean distribution down to the lowest measured source flux in the 2FHL (~8 x 10 -12 ph cm -2 s -1 ). We employ a one-point photon fluctuation analysis to constrain the behavior of dN/dS below the source detection threshold. Overall, the source count distribution is constrained over three decades in flux and found compatible with a broken power law with a break flux, S b , in the range [8 x 10 -12 , 1.5 x 10 -11 ] ph cm -2 s -1 and power-law indices below and above the break of α 2 ϵ [1.60, 1.75] and α 1 = 2.49 ± 0.12, respectively. Integration of dN/dS shows that point sources account for at least 86$+16\atop{-14}$ % of the total extragalactic γ-ray background. The simple form of the derived source count distribution is consistent with a single population (i.e., blazars) dominating the source counts to the minimum flux explored by this analysis. Finally, we estimate the density of sources detectable in blind surveys that will be performed in the coming years by the Cherenkov Telescope Array.

79 ASTRONOMY AND ASTROPHYSICS↗

Discovery of Gamma Rays from the Quiescent Sun with HAWC

We report the first detection of a TeV γ-ray flux from the solar disk (6.3⁢σ), based on 6.1 years of data from the High Altitude Water Cherenkov (HAWC) observatory. The 0.5–2.6 TeV spectrum is well fit by a power law, dN/dE = A⁢(E/1 TeV) -γ , with A = (1.6 ± 0.3)×10 -12 TeV -1 cm -2 s -1 and γ = 3.62 ± 0.14. The flux shows a strong indication of anticorrelation with solar activity. These results extend the bright, hard GeV emission from the disk observed with Fermi-LAT, seemingly due to hadronic Galactic cosmic rays showering on nuclei in the solar atmosphere. However, current theoretical models are unable to explain the details of how solar magnetic fields shape these interactions. HAWC’s TeV detection thus deepens the mysteries of the solar-disk emission.

79 ASTRONOMY AND ASTROPHYSICS↗

Lattice QCD Calculation of Electroweak Box Contributions to Superallowed Nuclear and Neutron Beta Decays

We present the first lattice QCD calculation of the universal axial γ W -box contribution □ γ W V A to both superallowed nuclear and neutron beta decays. This contribution emerges as a significant component within the theoretical uncertainties surrounding the extraction of | V u d | from superallowed decays. Our calculation is conducted using two domain wall fermion ensembles at the physical pion mass. To construct the nucleon four-point correlation functions, we employ the random sparsening field technique. Furthermore, we incorporate long-distance contributions to the hadronic function using the infinite-volume reconstruction method. Upon performing the continuum extrapolation, we arrive at □ γ W V A = 3.65 ( 7 ) lat ( 1 ) PT × 10 − 3 . Consequently, this yields a slightly higher value of | V u d | = 0.973 86 ( 11 ) exp ( 9 ) RC ( 27 ) NS , reducing the previous 2.1 σ tension with the CKM unitarity to 1.8 σ . Additionally, we calculate the vector γ W -box contribution to the axial charge g A , denoted as □ γ W V V , and explore its potential implications. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First observations of solar halo gamma rays over a full solar cycle

We analyze 15 years of Fermi-LAT data and produce a detailed model of the Sun’s inverse-Compton scattering emission (solar halo), which is powered by interactions between ambient cosmic-ray electrons and positrons with sunlight. By developing a novel analysis method to analyze moving sources, we robustly detect the solar halo at energies between 31.6 MeV and 100 GeV, and angular extensions up to 45° from the Sun, providing new insight into spatial regions where there are no direct measurements of the Galactic cosmic-ray flux. The large statistical significance of our signal allows us to subdivide the data and provide the first 𝛾-ray probes into the time variation and azimuthal asymmetry of the solar modulation potential, finding time-dependent changes in solar modulation both parallel and perpendicular to the ecliptic plane. Our results are consistent with (but with independent uncertainties from) local cosmic-ray measurements, unlocking new probes into astrophysical processes near the solar surface.

79 ASTRONOMY AND ASTROPHYSICS↗

Effects of magnetic and non-magnetic doping on the vortex lattice in MgB 2

Using small-angle neutron scattering we have studied the vortex lattice in superconducting MgB 2 , doped with either manganese or carbon to achieve a similar suppression of the critical temperature. Measurements were performed with the magnetic field applied along the c-axis, where the vortex lattice in pure MgB 2 is known to undergo a field-and temperature-driven 30° rotation transition. For Mn-doping, the vortex lat- tice phase diagram remains qualitatively similar to that of pure MgB 2 , indicating only a modest effect on the vortex-vortex interaction. In contrast, the vortex lattice rotation transition is completely suppressed in the C-doped case, likely due to a change in the electronic structure which affects the two-band/two-gap nature of superconductivity in MgB 2 . The vortex lattice longitudinal correlation length shows the opposite behavior, remaining roughly unchanged between pure and C-doped MgB 2 while it is significantly reduced in the Mn-doped case. However, the extensive vortex lattice metastability and related activated behavior, observed in conjunction with the vortex lattice transition in pure MgB 2 , is also seen in the Mn doped sample. This shows that the vortex lattice disordering is not associated with a substantially increased vortex pinning.

36 MATERIALS SCIENCE↗

SBS 0846+513: a new γ-ray-emitting narrow-line Seyfert 1 galaxy

In this paper, we report Fermi Large Area Telescope (LAT) observations of the radio-loud active galactic nucleus SBS 0846+513 (z = 0.5835), optically classified as a narrow-line Seyfert 1 galaxy, together with new and archival radio-to-X-ray data. The source was not active at γ-ray energies during the first two years of Fermi operation. A significant increase in activity was observed during 2010 October–2011 August. In particular, a strong γ-ray flare was observed in 2011 June reaching an isotropic γ-ray luminosity (0.1–300 GeV) of 1.0 × 10 48 erg s -1 , comparable to that of the brightest flat spectrum radio quasars, and showing spectral evolution in γ rays. An apparent superluminal velocity of (8.2 ± 1.5)c in the jet was inferred from 2011 to 2012 Very Long Baseline Array (VLBA) images, suggesting the presence of a highly relativistic jet. Finally, both the power released by this object during the flaring activity and the apparent superluminal velocity are strong indications of the presence of a relativistic jet as powerful as those of blazars. In addition, variability and spectral properties in radio and γ-ray bands indicate blazar-like behaviour, suggesting that, except for some distinct optical characteristics, SBS 0846+513 could be considered as a young blazar at the low end of the blazar's black hole mass distribution.

79 ASTRONOMY AND ASTROPHYSICS↗

Correlation and prediction uncertainties in the CyberKnife Synchrony respiratory tracking system

Purpose: The CyberKnife uses an online prediction model to improve radiation delivery when treating lung tumors. This study evaluates the prediction model used by the CyberKnife radiation therapy system in terms of treatment margins about the gross tumor volume (GTV). Methods: From the data log files produced by the CyberKnife synchrony model, the uncertainty in radiation delivery can be calculated. Modeler points indicate the tracked position of the tumor and Predictor points predict the position about 115 ms in the future. The discrepancy between Predictor points and their corresponding Modeler points was analyzed for 100 treatment model data sets from 23 de-identified lung patients. The treatment margins were determined in each anatomic direction to cover an arbitrary volume of the GTV, derived from the Modeler points, when the radiation is targeted at the Predictor points. Each treatment model had about 30 min of motion data, of which about 10 min constituted treatment time; only these 10 min were used in the analysis. The frequencies of margin sizes were analyzed and truncated Gaussian normal functions were fit to each direction's distribution. The standard deviation of each Gaussian distribution was then used to describe the necessary margin expansions in each signed dimension in order to achieve the desired coverage. In this study, 95% modeler point coverage was compared to 99% modeler coverage. Two other error sources were investigated: the correlation error and the targeting error. These were added to the prediction error to give an aggregate error for the CyberKnife during treatment of lung tumors. Results: Considering the magnitude of 2{sigma} from the mean of the Gaussian in each signed dimension, the margin expansions needed for 95% modeler point coverage were 1.2 mm in the lateral (LAT) direction and 1.7 mm in the anterior-posterior (AP) direction. For the superior-inferior (SI) direction, the fit was poor; but empirically, the expansions were 3.5 mm. For 99% modeler point coverage, the AP margin was 3.6 mm and the lateral margin was 2.9 mm. The SI margins for 99% modeler point coverage were highly variable. The aggregate error at 95% was 6.9 mm in the SI direction, 4.6 mm in the AP direction, and 3.5 in the lateral direction. Conclusions: The Predictor points follow the Modeler points closely. Margins were found in each clinical direction that would provide 95% modeler point coverage for 95% of the models reviewed in this study. Similar margins were found in two clinical directions for 99% modeler point coverage in 95% of models. These results can offer guidance in the selection of CTV margins for treatment with the CyberKnife.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-D-BRF-04: Digital Tomosynthesis for Improved Daily Setup in Treatment of Liver Lesions

Purpose: Daily localization of liver lesions with cone-beam CT (CBCT) is difficult due to poor image quality caused by scatter, respiratory motion, and the lack of radiographic contrast between the liver parenchyma and the lesion(s). Digital tomosynthesis (DTS) is investigated as a modality to improve liver visualization and lesion/parenchyma contrast for daily setup. Methods: An in-house tool was developed to generate DTS images using a point-by-point filtered back-projection method from on-board CBCT projection data. DTS image planes are generated in a user defined orientation to visualize the anatomy at various depths. Reference DTS images are obtained from forward projection of the planning CT dataset at each projection angle. The CBCT DTS image set can then be registered to the reference DTS image set as a means for localization. Contour data from the planning CT's associate RT Structure file and forward projected similarly to the planning CT data. DTS images are created for each contoured structure, which can then be overlaid onto the DTS images for organ volume visualization. Results: High resolution DTS images generated from CBCT projections show fine anatomical detail, including small blood vessels, within the patient. However, the reference DTS images generated from forward projection of the planning CT lacks this level of detail due to the low resolution of the CT voxels as compared to the pixel size in the projection images; typically 1mm-by-1mm-by-3mm (lat, vrt, lng) for the planning CT vs. 0.4mm-by-0.4mm for CBCT projections. Overlaying of the contours onto the DTS image allows for visualization of structures of interest. Conclusion: The ability to generate DTS images over a limited range of projection angles allows for reduction in the amount of respiratory motion within each acquisition. DTS may provide improved visualization of structures and lesions as compared to CBCT for highly mobile tumors.

60 APPLIED LIFE SCIENCES↗

SU-E-J-24: An Evaluation of the Stability of Image Quality Parameters of Varian On-Board Imaging (OBI) and EPID Imaging Systems

Purpose: Quality assurance of the image quality for image guided localization systems is crucial to ensure accurate visualization and localization of target volumes. In this study, the long term stability of selected image parameters was assessed and evaluated for CBCT mode, planar radiographic kV mode and the radiographic MV EPID mode. Methods: The CATPHAN, QckV-1 and QC-3 phantoms were used to evaluate the image quality parameters. The planar radiographic images were analyzed in PIPSpro™ with spatial resolution (f30, f40, f50) being recorded. For OBI CBCT, High quality head Full-Fan acquisition and Pelvis Half-Fan acquisition modes were evaluated for Uniformity, Noise, Spatial Resolution, HU constancy and geometric distortion. Dose and kVp for the OBI were recorded using the Unfors RaySafe Xi system with the R/F High Detector for planar kV and the CT detector for CBCT. Dose for the MV EPID was recorded using a PTW975 Semiflex Ion Chamber, PTW Unidos electrometer and SolidWater™. Results: For each metric, values were normalized to the mean and the standard deviations were recorded. For the planar radiographic spatial resolution the f30, f40, f50 were 0.015, 0.008, 0.004 and 0.006, 0.009, 0.018 for the kV and MV, respectively. The standard deviation of the dose for kV was 0.010 and 0.005 for the MV. The standard deviations for Full and half fan were averaged together and the following standard deviations for each metric were recorded: 0.075(uniformity), 0.071(noise), 0.006(AP-Geometric Distortion), 0.005(LAT-Geometric Distortion), 0.058(mean slice thickness), 0.098(f30),0.101(f40),0.124(f50), 0.031(Lung/PMP-HU constancy), 0.063(Water/poly-HU constancy), 0.015(Bone/Derlin-HU constancy),0.006(Dose-Center), 0.004(Dose-Periphery). Using these, tolerances can be reported as a warning and action threshold of 1σ and 2σ. Conclusion: A study was performed to assess the stability of the basic image quality parameters recommended by TG-142 for the Varian OBI and EPID Imaging systems. The two systems show consistent imaging and dosimetric properties over the evaluated time frame.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-244: Validation of a 6D-Robotic-Couch and Image Guidance Radiation Therapy (IGRT) System for Localization in World's First Single-Room Proton Therapy System

Purpose: The Mevion S250 proton therapy unit is equipped with a 6D-robotic couch and IGRT system (Verity). The patient alignment process allows corrections in six degrees of freedom: translation (x,y,z), pitch, roll, and yaw (θ,ϑ,ψ). Geometric accuracy of couch corrections and imaging vs. radiation isocenter coincidence were quantified before clinical implementation. Methods: A commercial phantom with sixteen 2mm tungsten BBs was rigidly couch-mounted and imaged with CT. Seventeen rigid translations/rotations of known magnitude were digitally applied to the original CT image using commercial software, validated with Varian OBI system. For each altered image, phantom was mounted on robotic couch in original position, then Verity 2D:2D match (PA-LLAT) was performed using DRRs from altered images. Corrections were recorded and applied, phantom was imaged a second time and residual corrections recorded. Physical measurements verified that applied couch corrections coincided with both physical couch shifts/rotations and known CT image translations/rotations. Additionally, image vs. radiation isocenter coicidence was quantified over couch treatment angles (±90° from setup position) using radiochromic film and an image-guided couch star-shot. Posterior-anterior and left-lateral kV radiographs were taken before each beam was delivered to verify imaging/radiation isocentricity. Results: Verity suggested couch corrections and known CT shifts/rotations agreed within ±1mm (average: Δ lat=0.5mm; Δ vert=0.4mm; Δ long=0.3mm) and ± 0.4° (average: Δ pitch=0.24° Δ roll=0.01°; Δ yaw=0.10°). Physical couch measurements and Verity applied corrections agreed within ± 1mm (average: Δlat=0.5mm; Δvert=0.4mm; Δlong=0.2mm) and ±0.2° (average: Δpitch=0.03°; Δ roll=0.04°; Δ yaw=0.04°). The directionality of all translations and rotations were qualitatively verified. The image vs. radiation isocenter coincidence was <1mm and radiation-isocenter precision was <1mm over the 180° of couch motion, as indicated by film analysis. Conclusion: The Verity IGRT software and 6D-couch combination on the Mevion S250 was verified as accurate within 1mm and 0.5°. This complies with the TG-142 standards for a stereotactic radiotherapy IGRT system. Rob Cessac is employed as Product Manager for Mevion Medical Systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-13: Six Degree of Freedom Image Fusion Accuracy for Cranial Target Localization On the Varian Edge Stereotactic Radiosurgery System: Comparison Between 2D/3D and KV CBCT Image Registration

Purpose: To determine the 6 degree of freedom systematic deviations between 2D/3D and CBCT image registration with various imaging setups and fusion algorithms on the Varian Edge Linac. Methods: An anthropomorphic head phantom with radio opaque targets embedded was scanned with CT slice thicknesses of 0.8, 1, 2, and 3mm. The 6 DOF systematic errors were assessed by comparing 2D/3D (kV/MV with CT) with 3D/3D (CBCT with CT) image registrations with different offset positions, similarity measures, image filters, and CBCT slice thicknesses (1 and 2 mm). The 2D/3D registration accuracy of 51 fractions for 26 cranial SRS patients was also evaluated by analyzing 2D/3D pre-treatment verification taken after 3D/3D image registrations. Results: The systematic deviations of 2D/3D image registration using kV- kV, MV-kV and MV-MV image pairs were within ±0.3mm and ±0.3° for translations and rotations with 95% confidence interval (CI) for a reference CT with 0.8 mm slice thickness. No significant difference (P>0.05) on target localization was observed between 0.8mm, 1mm, and 2mm CT slice thicknesses with CBCT slice thicknesses of 1mm and 2mm. With 3mm CT slice thickness, both 2D/3D and 3D/3D registrations performed less accurately in longitudinal direction than thinner CT slice thickness (0.60±0.12mm and 0.63±0.07mm off, respectively). Using content filter and using similarity measure of pattern intensity instead of mutual information, improved the 2D/3D registration accuracy significantly (P=0.02 and P=0.01, respectively). For the patient study, means and standard deviations of residual errors were 0.09±0.32mm, −0.22±0.51mm and −0.07±0.32mm in VRT, LNG and LAT directions, respectively, and 0.12°±0.46°, −0.12°±0.39° and 0.06°±0.28° in RTN, PITCH, and ROLL directions, respectively. 95% CI of translational and rotational deviations were comparable to those in phantom study. Conclusion: 2D/3D image registration provided on the Varian Edge radiosurgery, 6 DOF-based system provides accurate target positioning for frameless image-guided cranial stereotactic radiosurgery.

60 APPLIED LIFE SCIENCES↗

SU-E-J-48: Imaging Origin-Radiation Isocenter Coincidence for Linac-Based SRS with Novalis Tx

Purpose To implement and evaluate an image-based Winston-Lutz (WL) test to measure the displacement between ExacTrac imaging origin and radiation isocenter on a Novalis Tx system using RIT V6.2 software analysis tools. Displacement between imaging and radiation isocenters was tracked over time. The method was applied for cone-based and MLC-based WL tests. Methods The Brainlab Winston-Lutz phantom was aligned to room lasers. The ExacTrac imaging system was then used to detect the Winston- Lutz phantom and obtain the displacement between the center of the phantom and the imaging origin. EPID images of the phantom were obtained at various gantry and couch angles and analyzed with RIT calculating the phantom center to radiation isocenter displacement. The RIT and Exactrac displacements were combined to calculate the displacement between imaging origin and radiation isocenter. Results were tracked over time. Results Mean displacements between ExacTrac origin and radiation isocenter were: VRT: −0.1mm ± 0.3mm, LNG: 0.5mm ± 0.2mm, LAT: 0.2mm ± 0.2mm (vector magnitude of 0.7 ± 0.2mm). Radiation isocenter was characterized by the mean of the standard deviations of the WL phantom displacements: σVRT: 0.2mm, σLNG: 0.4mm, σLAT: 0.6mm. The linac couch base was serviced to reduce couch walkout. This reduced σLAT to 0.2mm. These measurements established a new baseline of radiation isocenter-imaging origin coincidence. Conclusion The image-based WL test has ensured submillimeter localization accuracy using the ExacTrac imaging system. Standard deviations of ExacTrac-radiation isocenter displacements indicate that average agreement within 0.3mm is possible in each axis. This WL test is a departure from the tradiational WL in that imaging origin/radiation isocenter agreement is the end goal not lasers/radiation isocenter.

60 APPLIED LIFE SCIENCES↗

SU-F-J-21: Clinical Evaluation of Surface Scanning Systems in Different Treatment Locations

Purpose: To reduce imaging dose in fractionated IGRT, the ability of optical surface imaging systems (OSIS) to detect setup errors was tested. Therefore, clinical studies to evaluate for different treatment locations setup corrections derived by OSIS in comparison with x-ray image guidance in fractionated radiation therapy was performed. Methods: The setup correction accuracy of an OSIS system (AlignRT, VisionRT, London, UK) will be analysed for the 4 tumour locations Pelvis, Upper Abdomen, Thorax and Breast, 20 patients for each location in comparison to a different system (Sentinel, C-RAD, SE). For each patient, the setup corrections of the cone-beam computed tomography (CBCT) of an Elekta Versa HD linear accelerator (Elekta, Crawley, UK) is considered as gold-standard and then compared with those of the OSIS for the first ten fractions retrospectively. There were no clinical decisions made based on the surrogate system. For the OSIS, the reference surface is highly important as it represents the actual ground truth. It can be obtained either with the system itself or the surface structure delineated in the planning CT can be imported via DICOM interface. In this paper, the first results for the treatment region thorax are presented. The reference image modalities were compared. Results: Table 1 displays the difference between the setup corrections obtained with OSIS and CBCT in lateral (LAT), longitudinal (LNG) and vertical (VRT) direction for the DICOM reference image. While the median deviations are within a few millimeters, some outliers showed large deviations. Generally, the mean deviation as well as the spread was smallest in lateral and largest in vertical direction. Conclusion: Although the system allows fast, simple and non-invasive determination of setup corrections, it should be evaluated treatment region dependant. Therefore, the study is ongoing. The application of OSIS may help to reduce the imaging dose for the patient. We gratefully acknowledge the support by our colleagues from the Radiological University Clinic Heidelberg, where the study was performed. This work was funded by the Federal Ministry of Education and Research (BMBF) Germany, grant number 01IB13001B.

60 APPLIED LIFE SCIENCES↗

SU-F-J-180: A Reference Data Set for Testing Two Dimension Registration Algorithms

Purpose: To create and characterize a reference data set for testing image registration algorithms that transform portal image (PI) to digitally reconstructed radiograph (DRR). Methods: Anterior-posterior (AP) and Lateral (LAT) projection and DRR image pairs from nine cases representing four different anatomical sites (head and neck, thoracic, abdominal, and pelvis) were selected for this study. Five experts will perform manual registration by placing landmarks points (LMPs) on the DRR and finding their corresponding points on the PI using computer assisted manual point selection tool (CAMPST), a custom-made MATLAB software tool developed in house. The landmark selection process will be repeated on both the PI and the DRR in order to characterize inter- and -intra observer variations associated with the point selection process. Inter and an intra observer variation in LMPs was done using Bland-Altman (B&A) analysis and one-way analysis of variance. We set our limit such that the absolute value of the mean difference between the readings should not exceed 3mm. Later on in this project we will test different two dimension (2D) image registration algorithms and quantify the uncertainty associated with their registration. Results: Using one-way analysis of variance (ANOVA) there was no variations within the readers. When Bland-Altman analysis was used the variation within the readers was acceptable. The variation was higher in the PI compared to the DRR.ConclusionThe variation seen for the PI is because although the PI has a much better spatial resolution the poor resolution on the DRR makes it difficult to locate the actual corresponding anatomical feature on the PI. We hope this becomes more evident when all the readers complete the point selection. The reason for quantifying inter- and -intra observer variation tells us to what degree of accuracy a manual registration can be done. Research supported by William Beaumont Hospital Research Start Up Fund.

60 APPLIED LIFE SCIENCES↗

Periodic Emission from the Gamma-Ray Binary 1FGL J1018.6-5856

Gamma-ray binaries are stellar systems containing a neutron star or black hole with gamma-ray emission produced by an interaction between the components. These systems are rare, even though binary evolution models predict dozens in our Galaxy. A search for gamma-ray binaries with the Fermi Large Area Telescope (LAT) shows that 1FGL J1018.6-5856 exhibits intensity and spectral modulation with a 16.6 day period. We identified a variable X-ray counterpart, which shows a sharp maximum coinciding with maximum gamma-ray emission, as well as an O6V((f)) star optical counterpart and a radio counterpart that is also apparently modulated on the orbital period. 1FGL J1018.6-5856 is thus a gamma-ray binary, and its detection suggests the presence of other fainter binaries in the Galaxy.

79 ASTRONOMY AND ASTROPHYSICS↗

Wimp searches with gamma rays in the Fermi era: Challenges, methods and results

The launch of the gamma-ray telescope Fermi Large Area Telescope (Fermi-LAT) started a pivotal period in indirect detection of dark matter. By outperforming expectations, for the first time a robust and stringent test of the paradigm of weakly interacting massive particles (WIMPs) is within reach. In this paper, we discuss astrophysical targets for WIMP detection and the challenges they present, review the analysis tools which have been employed to tackle these challenges, and summarize the status of constraints on and the claimed detections in the WIMP parameter space. Methods and results will be discussed in comparison to Imaging Air Cherenkov Telescopes. We also provide an outlook on short term and longer term developments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Is natural higgsino-only dark matter excluded?

The requirement of electroweak naturalness in supersymmetric (SUSY) models of particle physics necessitates light higgsinos not too far from the weak scale characterized by m(weak)~ m(W,Z,h)~100 GeV. On the other hand, LHC Higgs mass measurements and sparticle mass limits point to a SUSY breaking scale in the multi-TeV regime. Under such conditions, the lightest SUSY particle is expected to be a mainly higgsino-like neutralino with non-negligible gaugino components (required by naturalness). The computed thermal WIMP abundance in natural SUSY models is then found to be typically a factor 5-20 below its measured value. To gain concordance with observations, either an additional DM particle (the axion is a well-motivated possibility) must be present or additional non-thermal mechanisms must augment the neutralino abundance. We compare present direct and indirect WIMP detection limits to three natural SUSY models based on gravity-, anomaly- and mirage-mediation. We show that the case of natural higgsino-only dark matter where non-thermal production mechanisms augment its relic density, is essentially excluded by a combination of direct detection constraints from PandaX-II, LUX and Xenon-1t experiments, and by bounds from Fermi-LAT/MAGIC observations of gamma rays from dwarf spheroidal galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗