Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Isotopic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Hydrogen-deuterium isotope shift: From the 1S-2S-transition frequency to the proton-deuteron charge-radius difference

We analyze and review the theory of the hydrogen-deuterium isotope shift for the 1S-2S transition, which is one of the most accurately measured isotope shifts in any atomic system, in view of a recently improved experiment. A tabulation of all physical effects that contribute to the isotope shift is given. These include the Dirac binding energy, quantum electrodynamic effects, including recoil corrections, and the nuclear-size effect, including the pertaining relativistic and radiative corrections. From a comparison of the theoretical result {Delta}f{sub th}=670 999 566.90(66)(60) kHz (exclusive of the nonrelativistic nuclear-finite-size correction) and the experimental result {Delta}f{sub expt}=670 994 334 605(15) Hz, we infer the deuteron-proton charge-radius difference <r{sup 2}>{sub d}-<r{sup 2}>{sub p}=3.820 07(65) fm{sup 2} and the deuteron structure radius r{sub str}=1.975 07(78) fm.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Production of radioactive isotopes through cosmic muon spallation in KamLAND

Radioactive isotopes produced through cosmic muon spallation are a background for rare-event detection in nu detectors, double-beta-decay experiments, and dark-matter searches. Understanding the nature of cosmogenic backgrounds is particularly important for future experiments aiming to determine the pep and CNO solar neutrino fluxes, for which the background is dominated by the spallation production of {sup 11}C. Data from the Kamioka liquid-scintillator antineutrino detector (KamLAND) provides valuable information for better understanding these backgrounds, especially in liquid scintillators, and for checking estimates from current simulations based upon MUSIC, FLUKA, and GEANT4. Using the time correlation between detected muons and neutron captures, the neutron production yield in the KamLAND liquid scintillator is measured to be Y{sub n}=(2.8+-0.3)x10{sup -4} mu{sup -1} g{sup -1} cm{sup 2}. For other isotopes, the production yield is determined from the observed time correlation related to known isotope lifetimes. We find some yields are inconsistent with extrapolations based on an accelerator muon beam experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Properties of lead isotopes in the vicinity of the neutron drip line

On the basis of the Hartree-Fock method with Skyrme forces of the Ska, SkM*, and Sly4 type, the position of the neutron drip line and the properties of neutron-rich lead isotopes are studied with allowance for deformations. It is shown that, in extremely neutron-rich nuclei, the neutron and proton density distributions are characterized by an anomalously large deformation parameter of {beta} {approx} 0.6. Also, nuclei of superdeformed lead isotopes have anomalously large root-mean-square radii. The existence of the isotopes {sup 266-288}Pb, which are stable to the emission of one neutron, is predicted.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Helium isotope study of geothermal features in Chile with field and laboratory data

Helium isotope and stable isotope data from the El Tatio, Tinginguirica, Chillan, and Tolhuaca geothermal systems, Chile. Data from this submission are discussed in: Dobson, P.F., Kennedy, B.M., Reich, M., Sanchez, P., and Morata, D. (2013) Effects of volcanism, crustal thickness, and large scale faulting on the He isotope signatures of geothermal systems in Chile. Proceedings, 38th Workshop on Geothermal Reservoir Engineering, Stanford University, Feb. 11-13, 2013

15 GEOTHERMAL ENERGY↗

Final Progress Report: Isotope Identification Algorithm for Rapid and Accurate Determination of Radioisotopes Feasibility Study

This is the final report of the project titled, 'Isotope Identification Algorithm for Rapid and Accurate Determination of Radioisotopes,' PMIS project number LA10-HUMANID-PD03. The goal of the work was to demonstrate principles of emulating a human analysis approach towards the data collected using radiation isotope identification devices (RIIDs). It summarizes work performed over the FY10 time period. The goal of the work was to demonstrate principles of emulating a human analysis approach towards the data collected using radiation isotope identification devices (RIIDs). Human analysts begin analyzing a spectrum based on features in the spectrum - lines and shapes that are present in a given spectrum. The proposed work was to carry out a feasibility study that will pick out all gamma ray peaks and other features such as Compton edges, bremsstrahlung, presence/absence of shielding and presence of neutrons and escape peaks. Ultimately success of this feasibility study will allow us to collectively explain identified features and form a realistic scenario that produced a given spectrum in the future. We wanted to develop and demonstrate machine learning algorithms that will qualitatively enhance the automated identification capabilities of portable radiological sensors that are currently being used in the field.

07 ISOTOPE AND RADIATION SOURCES↗

Acquisition and processing of data for isotope-ratio-monitoring mass spectrometry

Methods are described for continuous monitoring of signals required for precise analyses of 13C, 18O, and 15N in gas streams containing varying quantities of CO2 and N2. The quantitative resolution (i.e. maximum performance in the absence of random errors) of these methods is adequate for determination of isotope ratios with an uncertainty of one part in 10(5); the precision actually obtained is often better than one part in 10(4). This report describes data-processing operations including definition of beginning and ending points of chromatographic peaks and quantitation of background levels, allowance for effects of chromatographic separation of isotopically substituted species, integration of signals related to specific masses, correction for effects of mass discrimination, recognition of drifts in mass spectrometer performance, and calculation of isotopic delta values. Characteristics of a system allowing off-line revision of parameters used in data reduction are described and an algorithm for identification of background levels in complex chromatograms is outlined. Effects of imperfect chromatographic resolution are demonstrated and discussed and an approach to deconvolution of signals from coeluting substances described.

NASA Discipline Exobiology↗

Remote Handling and Maintenance in the Facility for Rare Isotope Beams

Michigan State University (MSU) in East Lansing, MI was selected by the U.S. Department of Energy (DOE) to design and establish a Facility for Rare Isotope Beams (FRIB), a cutting-edge research facility to advance the understanding of rare nuclear isotopes and the evolution of the cosmos. The research conducted at the FRIB will involve experimentation with intense beams of rare isotopes within a well-shielded target cell that will result in activation and contamination of components. The target cell is initially hands-on accessible after shutdown and a brief cool-down period. Personnel are expected to have hands-on access to the tops of shielded component modules with the activated in-beam sections suspended underneath. The modules are carefully designed to include steel shielding for protecting personnel during these hand-on operations. However, as the facility has greater levels of activation and contamination, a bridge mounted servomaniputor may be added to the cell, to perform the disconnecting of services to the component assemblies. Dexterous remote handling and exchange of the modularized activated components is completed at a shielded window workstation with a pair of master-slave manipulators. The primary components requiring exchange or maintenance are the production target, the beam wedge filter, the beam dump, and the beam focusing and bending magnets. This paper provides an overview of the FRIB Target Facility remote handling and maintenance design requirements, concepts, and techniques.

36 MATERIALS SCIENCE↗

Quantifying uncertainty in stable isotope mixing models

Mixing models are powerful tools for identifying biogeochemical sources and determining mixing fractions in a sample. However, identification of actual source contributors is often not simple, and source compositions typically vary or even overlap, significantly increasing model uncertainty in calculated mixing fractions. This study compares three probabilistic methods, SIAR [ Parnell et al ., 2010] a pure Monte Carlo technique (PMC), and Stable Isotope Reference Source (SIRS) mixing model, a new technique that estimates mixing in systems with more than three sources and/or uncertain source compositions. In this paper, we use nitrate stable isotope examples (δ 15 N and δ 18 O) but all methods tested are applicable to other tracers. In Phase I of a three-phase blind test, we compared methods for a set of six-source nitrate problems. PMC was unable to find solutions for two of the target water samples. The Bayesian method, SIAR, experienced anchoring problems, and SIRS calculated mixing fractions that most closely approximated the known mixing fractions. For that reason, SIRS was the only approach used in the next phase of testing. In Phase II, the problem was broadened where any subset of the six sources could be a possible solution to the mixing problem. Results showed a high rate of Type I errors where solutions included sources that were not contributing to the sample. In Phase III some sources were eliminated based on assumed site knowledge and assumed nitrate concentrations, substantially reduced mixing fraction uncertainties and lowered the Type I error rate. These results demonstrate that valuable insights into stable isotope mixing problems result from probabilistic mixing model approaches like SIRS. The results also emphasize the importance of identifying a minimal set of potential sources and quantifying uncertainties in source isotopic composition as well as demonstrating the value of additional information in reducing the uncertainty in calculated mixing fractions.

54 ENVIRONMENTAL SCIENCES↗

Isotopic identification of soil and permafrost nitrate sources in an Arctic tundra ecosystem

The nitrate (NO₃⁻) dual isotope approach was applied to snowmelt, tundra active layer pore waters, and underlying permafrost in Barrow, Alaska, USA, to distinguish between NO₃⁻ derived from at NO₃⁻ signal with δ¹⁵N averaging –4.8 ± 1.0‰ (standard error of the mean) and δ¹⁸O averaging 70.2 ±1.7‰. In active layer pore waters, NO₃⁻ primarily occurred at concentrations suitable for isotopic analysis in the relatively dry and oxic centers of high-centered polygons. The average δ¹⁵N and δ¹⁸O of NO₃⁻ from high-centered polygons were 0.5 ± 1.1‰ and –4.1 ± 0.6‰, respectively. When compared to the δ¹⁵N of reduced nitrogen (N) sources, and the δ¹⁸O of soil pore waters, it was evident that NO₃⁻ in high-centered polygons was primarily from microbial nitrification. Permafrost NO₃⁻ had δ¹⁵N ranging from approximately –6‰ to 10‰, similar to atmospheric and microbial NO₃⁻, and highly variable δ¹⁸O ranging from approximately –2‰ to 38‰. Permafrost ice wedges contained a significant atmospheric component of NO₃⁻, while permafrost textural ice contained a greater proportion of microbially derived NO₃⁻. Large-scale permafrost thaw in this environment would release NO₃⁻ with a δ¹⁸O signature intermediate to that of atmospheric and microbial NO₃. Consequently, while atmospheric and microbial sources can be readily distinguished by the NO₃⁻ dual isotope technique in tundra environments, attribution of NO₃⁻ from thawing permafrost will not be straightforward. The NO₃⁻ isotopic signature, however, appears useful in identifying NO₃⁻ sources in extant permafrost ice.

54 ENVIRONMENTAL SCIENCES↗

Adding stable carbon isotopes improves model representation of the role of microbial communities in peatland methane cycling

Abstract Climate change is expected to have significant and uncertain impacts on methane (CH 4 ) emissions from northern peatlands. Biogeochemical models can extrapolate site‐specificCH 4 measurements to larger scales and predict responses of CH 4 emissions to environmental changes. However, these models include considerable uncertainties and limitations in representing CH 4 production, consumption, and transport processes. To improve predictions of CH 4 transformations, we incorporated acetate and stable carbon (C) isotopic dynamics associated with CH 4 cycling into a biogeochemistry model, DNDC. By including these new features, DNDC explicitly simulates acetate dynamics and the relative contribution of acetotrophic and hydrogenotrophic methanogenesis (AM and HM) to CH 4 production, and predicts the C isotopic signature (δ 13 C) in soil C pools and emitted gases. When tested against biogeochemical and microbial community observations at two sites in a zone of thawing permafrost in a subarctic peatland in Sweden, the new formulation substantially improved agreement with CH 4 production pathways and δ 13 C in emitted CH 4 (δ 13 C‐CH 4 ), a measure of the integrated effects of microbial production and consumption, and of physical transport. We also investigated the sensitivity of simulated δ 13 C‐CH 4 to C isotopic composition of substrates and, to fractionation factors for CH 4 production (α AM and α HM ), CH 4 oxidation (α MO ), and plant‐mediated CH 4 transport (α TP ). The sensitivity analysis indicated that the δ 13 C‐CH 4 is highly sensitive to the factors associated with microbial metabolism (α AM , α HM , and α MO ). The model framework simulating stable C isotopic dynamics provides a robust basis for better constraining and testing microbial mechanisms in predicting CH 4 cycling in peatlands.

54 ENVIRONMENTAL SCIENCES↗

Endogenous Production and Vibrational Analysis of Heavy-Isotope-Labeled Peptides from Cyanobacteria

Stable isotope labeling is an extremely useful tool for characterizing the structure, tracing the metabolism, and imaging the distribution of natural products in living organisms using mass-sensitive measurement techniques. In this study, a cyanobacterium was cultured in 15 N/ 13 C-enriched media to endogenously produce labeled, bioactive oligopeptides. The extent of heavy isotope incorporation in these peptides was determined with LC–MS, while the overall extent of heavy isotope incorporation in whole cells was studied with nanoSIMS and AFM-IR. Up to 98 % heavy isotope incorporation was observed in labeled cells. Three of the most abundant peptides, microcystin-LR (MCLR), cyanopeptolin-A (CYPA), and aerucyclamide-A (ACAA), were isolated and further studied with Raman and FTIR spectroscopies and DFT calculations. This revealed several IR and Raman active vibrations associated with functional groups not common in ribosomal peptides, like diene, ester, thiazole, thiazoline, and oxazoline groups, which could be suitable for future vibrational imaging studies. More broadly, this study outlines a simple and relatively inexpensive method for producing heavy-labeled natural products. Finally, manipulating the bacterial culture conditions by the addition of specific types and amounts of heavy-labeled nutrients provides an efficient means of producing heavy-labeled natural products for mass-sensitive imaging studies.

60 APPLIED LIFE SCIENCES↗

Implications of Underground Nuclear Explosion Cavity Evolution for Radioxenon Isotopic Composition

Abstract Isotopic ratios of radioxenons sampled in the atmosphere or subsurface can be used to verify the occurrence of an underground nuclear explosion (UNE). Differences in the half-lives of radioactive xenon precursors and their decay-chain networks produce different time-dependent concentration profiles of xenon isotopes allowing isotopic ratios to be used for tracking UNE histories including estimating the time of detonation. In this study, we explore the potential effects of post-detonation cavity processes: precipitation of iodine precursors, gas seepage, and prompt venting on radioxenon isotopic evolution which influences UNE histories. Simplified analytical models and closed-form solutions yielding a potentially idealized radioactive decay/ingrowth chain in a closed and well-mixed system typically have limited application by not including the partitioning of the radionuclide inventory between a gas phase and rock melt created by the detonation and by ignoring gas transport from the cavity to host rock or ground surface. In reality, either subsurface transport or prompt release that is principally responsible for gas signatures violates the closed-system (or batch-mode) assumption. A closed-form solution representing time-dependent source-term activities is extended by considering the cavity partitioning process, slow seepage, and/or prompt release of gases from the cavity and applied to realistic systems.

Sun, Yunwei (ORCID:0000000194801439)↗

Assessing groundwater availability and the response of the groundwater system to intensive exploitation in the North China Plain by analysis of long-term isotopic tracer data

The use of isotope tracers as a tool for assessing aquifer responses to intensive exploitation is demonstrated and used to attain a better understanding of the sustainability of intensively exploited aquifers in the North China Plain. Eleven well sites were selected that have long-term (years 1985–2014) analysis data of isotopic tracers. The stable isotopes δ{sup 18}O and δ{sup 2}H and hydrochemistry were used to understand the hydrodynamic responses of the aquifer system, including unconfined and confined aquifers, to groundwater abstraction. The time series data of {sup 14}C activity were also used to assess groundwater age, thereby contributing to an understanding of groundwater sustainability and aquifer depletion. Enrichment of the heavy oxygen isotope ({sup 18}O) and elevated concentrations of chloride, sulfate, and nitrate were found in groundwater abstracted from the unconfined aquifer, which suggests that intensive exploitation might induce the potential for aquifer contamination. The time series data of {sup 14}C activity showed an increase of groundwater age with exploitation of the confined parts of the aquifer system, which indicates that a larger fraction of old water has been exploited over time, and that the groundwater from the deep aquifer has been mined. The current water demand exceeds the sustainable production capabilities of the aquifer system in the North China Plain. Some measures must be taken to ensure major cuts in groundwater withdrawals from the aquifers after a long period of depletion.

58 GEOSCIENCES↗

RESOLUTION OF URANIUM ISOTOPES WITH KINETIC PHOSPHORESCENCE ANALYSIS

This study was conducted to test the ability of the Chemchek™ Kinetic Phosphorescence Analyzer Model KPA-11 with an auto-sampler to resolve the difference in phosphorescent decay rates of several different uranium isotopes, and therefore identify the uranium isotope ratios present in a sample. Kinetic phosphorescence analysis (KPA) is a technique that provides rapid, accurate, and precise determination of uranium concentration in aqueous solutions. Utilizing a pulsed-laser source to excite an aqueous solution of uranium, this technique measures the phosphorescent emission intensity over time to determine the phosphorescence decay profile. The phosphorescence intensity at the onset of decay is proportional to the uranium concentration in the sample. Calibration with uranium standards results in the accurate determination of actual concentration of the sample. Different isotopes of uranium, however, have unique properties which should result in different phosphorescence decay rates seen via KPA. Results show that a KPA is capable of resolving uranium isotopes.

Miley, Sarah M.↗

Integration of a hyphenated HPIC-ICPMS protocol for the measurement of transplutonium isotopic mass distributions for 252Cf campaigns at Oak Ridge National Laboratory

Rapid measurement of transplutonium isotopic mass distributions during 252Cf production campaigns at Oak Ridge National Laboratory is a critical need. Mass measurements for the isotopes of plutonium, americium, curium, and californium are routinely requested to support the α-hydroxy-isobutyrate runs for the purification and recovery of the heavy curium target material and final 249Bk, 252Cf, and 254Es enriched isotope products. This paper presents the integration of an online high-pressure ion chromatography inductively coupled plasma mass spectrometry technique together with the protocol and chemistry that allows for rapid baseline separation and direct quantification of the transplutonium elemental concentrations and isotopic compositions.

Roach, Benjamin↗

Optimization of a simultaneous dual-isotope {sup 201}Tl/{sup 123}I-MIBG myocardial SPECT imaging protocol with a CZT camera for trigger zone assessment after myocardial infarction for routine clinical settings: Are delayed acquisition and scatter correction necessary?

Background: Dual-isotope {sup 201}Tl/{sup 123}I-MIBG SPECT can assess trigger zones (dysfunctions in the autonomic nervous system located in areas of viable myocardium) that are substrate for ventricular arrhythmias after STEMI. This study evaluated the necessity of delayed acquisition and scatter correction for dual-isotope {sup 201}Tl/{sup 123}I-MIBG SPECT studies with a CZT camera to identify trigger zones after revascularization in patients with STEMI in routine clinical settings. Methods: Sixty-nine patients were prospectively enrolled after revascularization to undergo {sup 201}Tl/{sup 123}I-MIBG SPECT using a CZT camera (Discovery NM 530c, GE). The first acquisition was a single thallium study (before MIBG administration); the second and the third were early and late dual-isotope studies. We compared the scatter-uncorrected and scatter-corrected (TEW method) thallium studies with the results of magnetic resonance imaging or transthoracic echography (reference standard) to diagnose myocardial necrosis. Results: Summed rest scores (SRS) were significantly higher in the delayed MIBG studies than the early MIBG studies. SRS and necrosis surface were significantly higher in the delayed thallium studies with scatter correction than without scatter correction, leading to less trigger zone diagnosis for the scatter-corrected studies. Compared with the scatter-uncorrected studies, the late thallium scatter-corrected studies provided the best diagnostic values for myocardial necrosis assessment. Conclusions: Delayed acquisitions and scatter-corrected dual-isotope {sup 201}Tl/{sup 123}I-MIBG SPECT acquisitions provide an improved evaluation of trigger zones in routine clinical settings after revascularization for STEMI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of carbon stable isotopes to monitor biostimulation and electron donor fate in chromium-contaminated groundwater

Hexavalent chromium Cr(VI) is a common inorganic contaminant in industrial areas and represents a serious threat to human health due its toxicity. Here we report experimental results from a field-scale investigation of Cr(VI) bio-immobilization at Hanford 100H reservation, a U.S Department of Energy facility (Washington State, USA). Microbial Cr(VI) reduction was stimulated via injection of a 13 C-labeled sodium lactate solution into the high-permeability aquifer consisting of gravel and coarse sand sediments. Concentrations and carbon isotope ratios of metabolites, including dissolved inorganic carbon and total organic carbon, and compound-specific analysis of acetate and propionate, together with phospholipid fatty acids (biomass) have been analyzed to help provide an understanding of the predominant redox processes accompanying Cr(VI) reduction. Results of our study indicate that the injection of an electron donor caused a sharp decrease of Cr(VI) concentration from ~ 32 to ~ 10 nM. Cr(VI) reduction was associated with a decrease in the concentration of carboxylic acids, such as lactate (~ 6 mM to undetectable), propionate (~ 9 mM to undetectable), and acetate (~ 6 mM to undetectable), as well as dissolved inorganic carbon (30 to 10 mM C). Carbon isotope data indicate carbon transfers from the original substrate to organic byproducts and mineralized carbon. Concentrations of metabolites and stable isotope data as well as carbon isotope mass balance calculations were used to monitor biologically mediated reduction of Cr(VI).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗