Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image Transforms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Clementine High Resolution Camera Mosaicking Project: CL 6002; 0 deg S to 80 deg S Latitude, 0 deg E to 30 deg E Longitude - Volume 2

This compact disk (CD) is part of the Malin Space Science Systems (MSSS) effort to mosaic Clementine I high resolution (HiRes) camera lunar images. These mosaics were developed through calibration and semi-automated registration against the recently released geometrically and photometrically controlled Ultraviolet/Visible (UV/Vis) Basemap Mosaic, which is available through the PDS, as CD-ROM volumes CL_3001-3015. The HiRes mosaics are compiled from non-uniformity corrected, 750 nanometer ("D") filter high resolution observations from the HiRes imaging system onboard the Clementine Spacecraft. These mosaics are spatially warped using the sinusoidal equal-area projection at a scale of 20 m/pixel. The geometric control is provided by the 100 m/pixel U.S. Geological Survey (USGS) Clementine Basemap Mosaic compiled from the 750 nm Ultraviolet/Visible Clementine imaging system. Calibration was achieved by removing the image nonuniformity largely caused by the HiRes system's light intensifier. Also provided are offset and scale factors, achieved by a fit of the HiRes data to the corresponding photometrically calibrated UV/Vis basemap that approximately transform the 8-bit HiRes data to photometric units. The mosaics on this CD were compiled from sub-polar data (latitudes 80 degrees South to 80 degrees North; -80 to +80) within the longitude range 0-30 deg E. The mosaics are divided into tiles that cover approximately 1.75 degrees of latitude and span the longitude range of the mosaicked frames. Images from a given orbit are map projected using the orbit's nominal central latitude. This CD contains ancillary data files that support the HiRes mosaic. These files include browse images with UV/Vis context stored in a Joint Photographic Experts Group (JPEG) format, index files ('imgindx.tab' and 'srcindx.tab') that tabulate the contents of the CD, and documentation files. For more information on the contents and organization of the CD volume set refer to the "FILES, DIRECTORIES AND DISK CONTENTS" section of this document. The image files are organized according to NASA's Planetary Data System (PDS) standards. An image file (tile) is organized as a PDS labeled file containing an "image object".

Malin, Michael↗

Clementine High Resolution Camera Mosaicking Project: CL 6003; 0 deg N to 80 deg N Latitude, 30 deg E to 60 deg E Longitude - Volume 3

This compact disk (CD) is part of the Malin Space Science Systems (MSSS) effort to mosaic Clementine I high resolution (HiRes) camera lunar images. These mosaics were developed through calibration and semi-automated registration against the recently released geometrically and photometrically controlled Ultraviolet/Visible (UV/Vis) Basemap Mosaic, which is available through the PDS, as CD-ROM volumes CL_3001-3015. The HiRes mosaics are compiled from non-uniformity corrected, 750 nanometer ("D") filter high resolution observations from the HiRes imaging system onboard the Clementine Spacecraft. These mosaics are spatially warped using the sinusoidal equal-area projection at a scale of 20 m/pixel. The geometric control is provided by the 100 m/pixel U.S. Geological Survey (USGS) Clementine Basemap Mosaic compiled from the 750 nm Ultraviolet/Visible Clementine imaging system. Calibration was achieved by removing the image nonuniformity largely caused by the HiRes system's light intensifier. Also provided are offset and scale factors, achieved by a fit of the HiRes data to the corresponding photometrically calibrated UV/Vis basemap that approximately transform the 8-bit HiRes data to photometric units. The mosaics on this CD were compiled from sub-polar data (latitudes 80 degrees South to 80 degrees North; -80 to +80) within the longitude range 0-30 deg E. The mosaics are divided into tiles that cover approximately 1.75 degrees of latitude and span the longitude range of the mosaicked frames. Images from a given orbit are map projected using the orbit's nominal central latitude. This CD contains ancillary data files that support the HiRes mosaic. These files include browse images with UV/Vis context stored in a Joint Photographic Experts Group (JPEG) format, index files ('imgindx.tab' and 'srcindx.tab') that tabulate the contents of the CD, and documentation files. For more information on the contents and organization of the CD volume set refer to the "FILES, DIRECTORIES AND DISK CONTENTS" section of this document. The image files are organized according to NASA's Planetary Data System (PDS) standards. An image file (tile) is organized as a PDS labeled file containing an "image object".

Malin, Michael↗

Clementine High Resolution Camera Mosaicking Project: CL 6018; 80 deg N to 80 deg S Latitude, 330 deg E to 360 deg E Longitude - Volume 18

This compact disk (CD) is part of the Malin Space Science Systems (MSSS) effort to mosaic Clementine I high resolution (HiRes) camera lunar images. These mosaics were developed through calibration and semi-automated registration against the recently released geometrically and photometrically controlled Ultraviolet/Visible (UV/Vis) Basemap Mosaic, which is available through the PDS, as CD-ROM volumes CL_3001-3015. The HiRes mosaics are compiled from non-uniformity corrected, 750 nanometer ("D") filter high resolution observations from the HiRes imaging system onboard the Clementine Spacecraft. These mosaics are spatially warped using the sinusoidal equal-area projection at a scale of 20 m/pixel. The geometric control is provided by the 100 m/pixel U. S. Geological Survey (USGS) Clementine Basemap Mosaic compiled from the 750 nm Ultraviolet/Visible Clementine imaging system. Calibration was achieved by removing the image nonuniformity largely caused by the HiRes system's light intensifier. Also provided are offset and scale factors, achieved by a fit of the HiRes data to the corresponding photometrically calibrated UV/Vis basemap that approximately transform the 8-bit HiRes data to photometric units. The mosaics on this CD were compiled from sub-polar data (latitudes 80 degrees South to 80 degrees North; -80 to +80) within the longitude range 0-30 deg E. The mosaics are divided into tiles that cover approximately 1.75 degrees of latitude and span the longitude range of the mosaicked frames. Images from a given orbit are map projected using the orbit's nominal central latitude. This CD contains ancillary data files that support the HiRes mosaic. These files include browse images with UV/Vis context stored in a Joint Photographic Experts Group (JPEG) format, index files ('imgindx.tab' and 'srcindx.tab') that tabulate the contents of the CD, and documentation files. For more information on the contents and organization of the CD volume set refer to the "FILES, DIRECTORIES AND DISK CONTENTS" section of this document. The image files are organized according to NASA's Planetary Data System (PDS) standards. An image file (tile) is organized as a PDS labeled file containing an "image object".

Malin, Michael↗

Clementine High Resolution Camera Mosaicking Project: CL 6017; 0 deg to 80 deg S Latitude, 330 deg E Longitude - Volume 17

This compact disk (CD) is part of the Malin Space Science Systems (MSSS) effort to mosaic Clementine I high resolution (HiRes) camera lunar images. These mosaics were developed through calibration and semi-automated registration against the recently released geometrically and photometrically controlled Ultraviolet/Visible (UV/Vis) Basemap Mosaic, which is available through the PDS, as CD-ROM volumes CL_3001-3015. The HiRes mosaics are compiled from non-uniformity corrected, 750 nanometer ("D") filter high resolution observations from the HiRes imaging system onboard the Clementine Spacecraft. These mosaics are spatially warped using the sinusoidal equal-area projection at a scale of 20 m/pixel. The geometric control is provided by the 100 m/pixel U.S. Geological Survey (USGS) Clementine Basemap Mosaic compiled from the 750 nm Ultraviolet/Visible Clementine imaging system. Calibration was achieved by removing the image nonuniformity largely caused by the HiRes system's light intensifier. Also provided are offset and scale factors, achieved by a fit of the HiRes data to the corresponding photometrically calibrated UV/Vis basemap that approximately transform the 8-bit HiRes data to photometric units. The mosaics on this CD were compiled from sub-polar data (latitudes 80 degrees South to 80 degrees North; -80 to +80) within the longitude range 0-30 deg E. The mosaics are divided into tiles that cover approximately 1.75 degrees of latitude and span the longitude range of the mosaicked frames. Images from a given orbit are map projected using the orbit's nominal central latitude. This CD contains ancillary data files that support the HiRes mosaic. These files include browse images with UV/Vis context stored in a Joint Photographic Experts Group (JPEG) format, index files ('imgindx.tab' and 'srcindx.tab') that tabulate the contents of the CD, and documentation files. For more information on the contents and organization of the CD volume set refer to the "FILES, DIRECTORIES AND DISK CONTENTS" section of this document. The image files are organized according to NASA's Planetary Data System (PDS) standards. An image file (tile) is organized as a PDS labeled file containing an "image object".

Malin, Michael↗

A technique for increasing the accuracy of the numerical inversion of the Laplace transform with applications

A technique is introduced which extends the range of useful approximation of numerical inversion techniques to many cycles of an oscillatory function without requiring either the evaluation of the image function for many values of s or the computation of higher-order terms. The technique consists in reducing a given initial value problem defined over some interval into a sequence of initial value problems defined over a set of subintervals. Several numerical examples demonstrate the utility of the method.

Berger, B. S.↗

Astronomical imaging by pupil plane interferometry

Comparing rotational shear interferometry to standard speckle interferometry, it is found that it is easier in the first case to separate the atmospheric phases from the object transform phases. Phase closure and blind deconvolution should be directly applicable. Laboratory simulations were conducted to verify theoretical predictions and computer simulations for the phase closure case, and preliminary results show promise.

Ribak, Erez↗

A comparison of histopathology imaging comprehension algorithms based on multiple instance learning

Whole slide imaging (WSI), also called digital virtual microscopy, is a new imaging modality. It allows for the application of AI and machine learning methods to cancer pathology to help establish a means for the automatic diagnosis of cancer cases. However, designing machine-learning models for WSI is computationally challenging due to its required ultra-high resolution. The current state-of-the-art models use multiple instance learning (MIL). MIL is a weakly-supervised learning method in which the model uses an array of inferences from many smaller instances to make a final classification about the entire set. In the context of WSI, researchers divide the ultra-high-resolution image into many patches. The model then classifies the slide based on an array of inferences from the patches. Among several ways of making the final classification, attention-based mechanisms have resulted in superb accuracy scores. The Transformer, one attention-based algorithm, has reported substantial improvements for WSI comprehension tasks. In this project, we studied and compared several WSI comprehension algorithms. We used the following three datasets: CAMELYON16+17, TCGALung, and TCGA-Kidney. We found that attention-based MIL algorithms performed better than standard MIL algorithms for classifying WSI images, achieving a higher mean accuracy and AUC. However, none of the attention-based algorithms performed significantly better than the others, reporting accuracy scores that varied widely. Presumably, it is due to the limited availability of training samples in the data corpus. Since it is not easy to increase the samples from human subjects, some machine learning techniques like transfer learning could help mitigate this issue.

Saunders, Adam↗

Harnessing quantum light for microscopic biomechanical imaging of cells and tissues

The biomechanical properties of cells and tissues play an important role in our fundamental understanding of the structures and functions of biological systems at both the cellular and subcellular levels. Recently, Brillouin microscopy, which offers a label-free spectroscopic means of assessing viscoelastic properties in vivo, has emerged as a powerful way to interrogate those properties on a microscopic level in living tissues. However, susceptibility to photodamage and photobleaching, particularly when high-intensity laser beams are used to induce Brillouin scattering, poses a significant challenge. This article introduces a transformative approach designed to mitigate photodamage in biological and biomedical studies, enabling nondestructive, label-free assessments of mechanical properties in live biological samples. By leveraging quantum-light-enhanced stimulated Brillouin scattering (SBS) imaging contrast, the signal-to-noise ratio is significantly elevated, thereby increasing sample viability and extending interrogation times without compromising the integrity of living samples. The tangible impact of this methodology is evidenced by a notable three-fold increase in sample viability observed after subjecting the samples to three hours of continuous squeezed-light illumination, surpassing the traditional coherent light-based approaches. The quantum-enhanced SBS imaging holds promise across diverse fields, such as cancer biology and neuroscience where preserving sample vitality is of paramount significance. By mitigating concerns regarding photodamage and photobleaching associated with high-intensity lasers, this technological breakthrough expands our horizons for exploring the mechanical properties of live biological systems, paving the way for an era of research and clinical applications.

Li, Tian↗

RIFTA: A Robust Iterative Fourier Transform-based dwell time Algorithm for ultra-precision ion beam figuring of synchrotron mirrors

With the rapid evolution of synchrotron X-ray sources, the demand for high-precision X-ray mirrors has greatly increased. Single nanometer profile error is required to keep imaging capability at the diffraction limit. Ion Beam Figuring (IBF), as a highly deterministic surfacing technique, has been used for ultra-precision finishing of mirrors. One crucial step that guides the IBF process is dwell time calculation. A valid dwell time solution should be non-negative and duplicate the shape of the desired removal map. Another important aspect is to minimize the total dwell time. In this study, we propose a Robust Iterative Fourier Transform-based dwell time Algorithm (RIFTA) that automatically fulfills these requirements. First, the thresholded inverse filtering in Fourier transform-based deconvolution is stabilized and automated by optimizing the threshold value using the Nelder-Mead simplex algorithm. Second, a novel two-level iterative scheme is proposed to guarantee the minimized total dwell time with its non-negativity at each dwell point. Third, a bicubic resampling is employed to flexibly adapt the calculated dwell time map to any IBF process intervals. The performance of RIFTA is first studied with simulation, followed by a comparison with the other state-of-the-art dwell time algorithms. We then demonstrate with an experiment that, using the dwell time calculated by the RIFTA, the total dwell time is shortened by a factor of two and the RMS in a 5 × 50 mm clear aperture was reduced from 3.4 nm to 1.1 nm after one IBF run, which proves the effectiveness and the efficiency of the proposed algorithm.

42 ENGINEERING↗

Quantum AI Based Enhanced Detection of Dementia

Quantum computing has the potential to significantly improve the early detection of Alzheimer's Disease and Related Dementias (ADRD). Quantum-enhanced machine learning can be used to perform an early screening of Alzheimer's disease using brain imaging data based on dataset of MRI scans from both healthy individuals and those diagnosed with Alzheimer's. This study aims to demonstrate the potential of quantum transfer learning to enhance the performance of the classical deep learning model for dementia detection. Using the MRI sagittal images available in the OASIS-2 (64 demented and 72 non-demented subjects between 60 and 96 years), we show how quantum techniques can transform a suboptimal classical model into a more effective solution for dementia detection, highlighting their potential impact on advancing healthcare technology. We begin with a simple classical deep learning model with a significantly smaller number of parameters, which gives suboptimal performance on the problem. Then, we apply different configurations of quantum transfer learning based on the pre-trained weak classifier (Figure 1). We fix the weak classifier's initial convolutional layers at their fixed pre-trained parameters and replace the last set of dense layers with a dressed quantum circuit (DQN), which we train to enhance performance. We performed 4-fold cross-validation for both the classical and the hybrid quantum models and trained them using Pennylane's `default.qubit' simulator and IonQ's Aria-1 simulator (noisy simulation). We showed that with significantly fewer parameters, the quantum transfer learning-based hybrid models showed significant performance enhancement over the base weak classical deep learning model for dementia detection. To classify between a demented and non-demented subject, the accuracy of quantum-based AI methods improved by 6 to 14% compared to classical methods. The sensitivity of the models improved by 4 to 17%. This shows that there are fewer chances of misclassifying demented patients. Figure 2 compares the performance of the hybrid quantum models and their base classical model, and Table 1 summarizes the results. We illustrated that with assistance from quantum machine learning, it is possible to enhance detection for dementia based on brain images. This shows the potential for practical utility of quantum computing in ADRD research.

Bhowmik, Sounak [University of Tennessee, Knoxvill↗

Multislice forward modeling of coherent surface scattering imaging on surface and interfacial structures

To study nanostructures on substrates, surface-sensitive reflection-geometry scattering techniques such as grazing incident small angle X-ray scattering are commonly used to yield an averaged statistical structural information of the surface sample. Grazing incidence geometry can probe the absolute three-dimensional structural morphology of the sample if a highly coherent beam is used. Coherent surface scattering imaging (CSSI) is a powerful yet non-invasive technique similar to coherent X-ray diffractive imaging (CDI) but performed at small angles and grazing-incidence reflection geometry. A challenge with CSSI is that conventional CDI reconstruction techniques cannot be directly applied to CSSI because the Fourier-transform-based forward models cannot reproduce the dynamical scattering phenomenon near the critical angle of total external reflection of the substrate-supported samples. To overcome this challenge, we have developed a multislice forward model which can successfully simulate the dynamical or multi-beam scattering generated from surface structures and the underlying substrate. The forward model is also demonstrated to be able to reconstruct an elongated 3D pattern from a single shot scattering image in the CSSI geometry through fast-performing CUDA-assisted PyTorch optimization with automatic differentiation.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Deriving the Coronal Magnetic Field Using Parametric Transformation Analysis

When plasma-beta greater than 1 then the gas pressure dominates over the magnetic pressure. This ratio as a function along the coronal magnetic field lines varies from beta greater than 1 in the photosphere at the base of the field lines, to beta much less than 1 in the mid-corona, to beta greater than 1 in the upper corona. Almost all magnetic field extrapolations do not or cannot take into account the full range of beta. They essentially assume beta much less than 1, since the full boundary conditions do not exist in the beta greater than 1 regions. We use a basic parametric representation of the magnetic field lines such that the field lines can be manipulated to match linear features in the EUV and SXR coronal images in a least squares sense. This research employs free-form deformation mathematics to generate the associated coronal magnetic field. In our research program, the complex magnetic field topology uses Parametric Transformation Analysis (PTA) which is a new and innovative method to describe the coronal fields that we are developing. In this technique the field lines can be viewed as being embedded in a plastic medium, the frozen-in-field-line concept. As the medium is deformed the field lines are similarly deformed. However the advantage of the PTA method is that the field line movement represents a transformation of one magnetic field solution into another magnetic field solution. When fully implemented, this method will allow the resulting magnetic field solution to fully match the magnetic field lines with EUV/SXR coronal loops by minimizing the differences in direction and dispersion of a collection of PTA magnetic field lines and observed field lines. The derived magnetic field will then allow beta greater than 1 regions to be included, the electric currents to be calculated, and the Lorentz force to be determined. The advantage of this technique is that the solution is: (1) independent of the upper and side boundary conditions, (2) allows non-vanishing magnetic forces, and (3) provides a global magnetic field solution, which contains high- and low-beta regimes and maximizes the similarity between the field lines structure and all the coronal images of the region. The coronal image analysis is crucial to the investigation and for the first time these images can be exploited to derive the coronal magnetic field in a well-posed mathematical formulation. This program is an outgrowth of an investigation in which an extrapolated potential field was required to be "inflated" in order to have the field lines match the Yohkoh/SXT images. The field lines were radially stretched resulting in a better match to the coronal loops of an active region. The PTA method of radial and non-radial deformations of field lines to provide a match to the EUV/SXR images will be presented.

Gary, G. Allen↗

Chemical and physical transformations of carbon-based nanomaterials observed by liquid phase transmission electron microscopy

This article addresses recent advances in liquid phase transmission electron microscopy (LPTEM) for studying nanoscale synthetic processes of carbon-based materials that are independent of the electron beam—those driven by nonradiolytic chemical or thermal reactions. In particular, we focus on chemical/physical formations and the assembly of nanostructures composed of organic monomers/polymers, peptides/DNA, and biominerals. The synthesis of carbon-based nanomaterials generally only occurs at specific conditions, which cannot be mimicked by aqueous solution radiolysis. Carbon-based structures themselves are also acutely sensitive to the damaging effects of the irradiating beam, which make studying their synthesis using LPTEM a unique challenge that is possible when beam effects can be quantifi ed and mitigated. With new direct sensing, high frame rate cameras, and advances in liquid-cell holder designs, combined with a growing understanding of irradiation effects and proper experimental controls, microscopists have been able to make strides in observing traditionally problematic carbon-based materials under conditions where synthesis can be controlled, and imaged free from beam effects, or with beam effects quantified and accounted for. These materials systems and LPTEM experimental techniques are discussed, focusing on nonradiolytic chemical and physical transformations relevant to materials synthesis.

Parent, Lucas R.↗

FeCo Nanorods Preparation Using New Chemical Synthesis

The as-prepared and annealed iron/cobalt (FeCo) magnetic nanoparticles (NPs) were obtained using a simple method by iron chloride hexahydrate (FeCl{sub 3}.6H{sub 2}O) and cobalt chloride hexahydrate (CoCl{sub 3}.6H{sub 2}O) as precursors and sodium borohydride (NaBH{sub 4}) agent. The samples were characterized by high-resolution transmission electron microscopy (HRTEM), field effect scanning electron microscopy (FESEM), x-ray diffraction (XRD), electron-dispersive spectroscopy (EDS), and Fourier transform infrared spectroscopy (FTIR). The XRD patterns of FeCo samples showed the body center cubic (bcc) structure with a lattice constant of 2.70 Å. The SEM images showed that the particle size of the as-prepared sample was around 15 nm and the annealed sample was around 35 nm in diameter at 500 {sup ∘}C. It was found that by increasing annealing temperature, the size of the FeCo NPs increased to 60 nm at 1100 {sup ∘}C. TEM studies showed the rod-like particles for annealed sample. The sharp peaks in FTIR spectrum determined the element of FeCo NPs. EDS shows peaks of iron and cobalt with impurities in prepared samples. The result of magnetic measurements showed a good coercive field and saturation magnetization around 1158 Oe and 22 emu g{sup − 1}, respectively.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Imaging the kinetics of anisotropic dissolution of bimetallic core–shell nanocubes using graphene liquid cells

Chemical design of multicomponent nanocrystals requires atomic-level understanding of reaction kinetics. Here, we apply single-particle imaging coupled with atomistic simulation to study reaction pathways and rates of Pd@Au and Cu@Au core-shell nanocubes undergoing oxidative dissolution. Quantitative analysis of etching kinetics using in situ transmission electron microscopy (TEM) imaging reveals that the dissolution mechanism changes from predominantly edge-selective to layer-by-layer removal of Au atoms as the reaction progresses. Dissolution of the Au shell slows down when both metals are exposed, which we attribute to galvanic corrosion protection. Morphological transformations are determined by intrinsic anisotropy due to coordination-number-dependent atom removal rates and extrinsic anisotropy induced by the graphene window. Our work demonstrates that bimetallic coreshell nanocrystals are excellent probes for the local physicochemical conditions inside TEM liquid cells. Furthermore, single-particle TEM imaging and atomistic simulation of reaction trajectories can inform future design strategies for compositionally and architecturally sophisticated nanocrystals.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Holographic Nano‐Imaging of Terahertz Dirac Plasmon Polaritons in Topological Insulator Antenna Resonators

Abstract Excitation of Dirac plasmon polaritons (DPPs) in bi‐dimensional materials have attracted considerable interest in recent years, both from perspectives of understanding their physics and exploring their transformative potential for nanophotonic devices, including ultra‐sensitive plasmonic sensors, ultrafast saturable absorbers, modulators, and switches. Topological insulators (TIs) represent an ideal technological platform in this respect because they can support plasmon polaritons formed by Dirac carriers in the topological surface states. Tracing propagation of DPPs is a very challenging task, particularly at terahertz (THz) frequencies, where the DPP wavelength becomes over one order of magnitude shorter than the free space photon wavelength. Furthermore, severe attenuation hinders the comprehensive analysis of their characteristics. Here, the properties of DPPs in real TI‐based devices are revealed. Bi 2 Se 3 rectangular antennas can efficiently confine the propagation of DPPs to a single dimension and, as a result, enhance the DPPs visibility despite the strong intrinsic attenuation. The plasmon dispersion and loss properties from plasmon profiles are experimentally determined, along the antennas, obtained using holographic near‐field nano‐imaging in a wide range of THz frequencies, from 2.05 to 4.3 THz. The detailed investigation of the unveiled DPP properties can guide the design of novel topological quantum devices exploiting their directional propagation.

Chemistry↗

In-situ L-TEM observations of dynamics of nanometric skyrmions and antiskyrmions

Nanometer-scale magnetic skyrmions and antiskyrmions exhibit unique dynamical behaviors in response to external stimuli, which are critical for their applications in low-power-consumption spintronic devices. This review discusses recent advancements in in-situ Lorentz transmission electron microscopy (L-TEM) observations of skyrmion and antiskyrmion dynamics, and demonstrates the manipulation and evolution of these textures in various magnetic materials under electric, magnetic, and thermal stimuli. Specifically, the motion tracking of single skyrmions and their clusters, and the deformation and transformation of skyrmions has been demonstrated in chiral helimagnets FeGe, Co 9 Zn 9 Mn 2 , and Co 10 Zn 10 with precise application of electric currents. Skyrmions can undergo dynamic transitions in current-driven skyrmion motions, from pinned states to linear flows, and even exhibit deformation into elliptical shapes, underscoring their topological robustness and dynamic flexibility. In addition, the manipulation of single antiskyrmions and antiskyrmion-lattice phases in (Fe 0.63 Ni 0.3 Pd 0.07 ) 3 P with S 4 symmetry is discussed, highlighting their high mobility and unique sliding capabilities along stripe domains at room temperature, facilitated by nanosecond pulsed electric currents. Finally, the temperature gradient-driven motion and topological transformation of elliptical skyrmions and antiskyrmions in this same material are investigated. In conclusion, the comprehensive insights gained from the L-TEM imaging technique are pivotal in advancing the design and functionality of next-generation skyrmion/antiskyrmion-based spintronic devices.

(Anti)skyrmion↗