Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Grid services”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Subsetting Satellite Level 2 Data at NASA GES DISC

Working with Level 2 satellite swath data can prove challenging for many users. The variety of metadata, high resolution, and orbit-based nature of such data makes it difficult to acquire and manage. The NASA Goddard Earth Sciences Data and Information Services Center (GES DISC) has developed a general-purpose Level 2 Subsetting service that facilitates access to Level 2 data products. The Level 2 Subsetter enables users to sub-sample swath and gridded data in a variety of ways: by location (in a lat/lon box, within a circle of given radius, or at a specific point), by time (via swath segments or collections of granules), by any nonspatial dimension, or by selecting specific variables. The Level 2 Subsetting service also allows users to specify output data configuration and file format. In this presentation, we will detail and demonstrate the capabilities of this new service.

Huwe, Paul↗

Wind 2H2 Project: CRADA Final Report (Project 2)

The Xcel-NLR Wind Electrolysis R&D Project is designed to gain knowledge and insight about producing hydrogen from electricity for use as a vehicle fuel and as a "stored wind". The project will analyze producing hydrogen directly from wind as well as from the electric grid. In addition, it will look at storing hydrogen and then using it to put electricity back onto the grid.

17 WIND ENERGY↗

An Overview of Behind-the-Meter Solar-Plus-Storage Program Design: With Considerations for India

Indian consumers have been deploying behind-the-meter generation (predominantly diesel backup, and, more recently, photovoltaic) and storage systems (predominantly lead-acid and other kinds of batteries as uninterrupted power supplies) by the millions for decades) to address reliability issues within the Indian power system. The same energy storage systems could provide additional services to the consumer and distribution companies if properly regulated and designed from the outset to be grid interactive. Grid-connected distributed solar PV (DPV), or rooftop solar, has also seen wide deployment in India and features prominently in the Government of India’s plans for a transition to clean, reliable, and affordable energy for all. At the same time, many utilities and state governments, as well as the central government in India are currently funding-constrained for both operational and future capital expenditures in the power sector, and some perceive customer-sited resources as exacerbating existing financial challenges. In that context, behind-the-meter energy storage systems paired with distributed photovoltaic (DPV) - with the capability to act as both generation and load - represent a potentially unique and disruptive power sector technology capable of providing a range of important services to customers, utilities, and the broader power system in India. This report aims to offer a comprehensive, evidence-based approach to designing customer programs based on experience in the United States that can help regulators, utilities, and policymakers in India manage the range of challenges and opportunities that increased behind-the-meter energy storage deployment will bring to the power system, in particular when these systems are paired with DPV.

14 SOLAR ENERGY↗

A method for assessing economic, environmental, and reliability tradeoffs of interregional transmission connecting ERCOT (the Texas grid) to the eastern and western grids

Reliable development of the power grid is an evolving concern for humanity due to extreme weather that frequently threatens power sector infrastructure. The state of Texas is a uniquely structured testbed for grid planners to study when looking for solutions to development, innovation, and overcoming such challenges. Because of its size and islanded structure, Texas is small enough to model, but big enough to matter. Texas is a global leader in energy production, energy consumption, and maintains an unusually diverse fuel mix. In addition, the state has experienced winter freezes, heat waves, wind storms, droughts and floods that have threatened power sector infrastructure or caused recent blackouts and calls for demand side conservation. One of the most devastating of these events was the North American winter storm, dubbed “Winter Storm Uri” by the Weather Channel, that froze the region in February 2021 and led to an extended power outage event that put the majority of Texan residents in darkness for days. While preparing to avoid such outage events in the future, various tools have been proposed to improve grid reliability, including energy efficiency, demand response, and distributed energy resources. An additional option would be to develop interregional transmission that connects the Texas grid to other national grids. To assess the merits of this idea, we developed a novel, universally-applicable and internationally-relevant framework to study how the Texas grid would evolve alongside access to various interregional ties. This method allows us to stress the synthetic grid structure and analyze how it would respond to the shock of a simulated winter storm event. Our method leverages open-source modeling tools, such as PowerGenome, pyGRETA, and GenX to synthesize unique zonal grid data, construct a consolidated network of model regions, and simulate different developmental pathways of capacity expansion and operational dispatch. We demonstrate our method with an analysis connecting the Electric Reliability Council of Texas (ERCOT), the grid that serves most of Texas, the Western Electricity Coordinating Council (WECC), the grid that serves the western half of the contiguous U.S., and the Eastern Interconnect, the grid that serves the eastern half of the contiguous U.S. Our results indicate that the cost-optimal capacity of interregional transmission connecting the ERCOT grid to other grids lies between 9–13 GW assuming baseline conditions. Building this amount of connecting capacity in one or multiple directions lowers the costs and emissions of development and operation by up to $16 billion and 257 million metric tonnes (MMT) respectively. Additionally, our results show that the interregional connections between ERCOT and other national grids reduce the amount of total load shed required through mild winter storm events. However, our results also show that there is a threshold of very extreme winter storm conditions, spanning multiple service areas, above which the connections exacerbate resource adequacy problems. Therefore, the results indicate that the connections need to be carefully planned alongside the rest of the grid infrastructure to avoid over-reliance on specific resources or technology options.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enabling fast charging – Infrastructure and economic considerations

The ability to charge battery electric vehicles (BEVs) on a time scale that is on par with the time to fuel an internal combustion engine vehicle (ICEV) would remove a significant barrier to the adoption of BEVs. However, for viability, fast charging at this time scale needs to also occur at a price that is acceptable to consumers. Therefore, the cost drivers for both BEV owners and charging station providers are analyzed. In addition, key infrastructure considerations are examined, including grid stability and delivery of power, the design of fast charging stations and the design and use of electric vehicle service equipment. Each of these aspects have technical barriers that need to be addressed, and are directly linked to economic impacts to use and implementation. This discussion focuses on both the economic and infrastructure issues which exist and need to be addressed for the effective implementation of fast charging at 400 kW and above. In so doing, it has been found that there is a distinct need to effectively manage the intermittent, high power demand of fast charging, strategically plan infrastructure corridors, and to further understand the cost of operation of charging infrastructure and BEVs.

33 ADVANCED PROPULSION SYSTEMS↗

Regulatory Policy and Markets for Energy Storage in North America

The last 5 years have been one of the most exciting times for the energy storage industry. We have seen significant advancements in the regulatory process to make accommodations for valuing and monetizing energy storage for what it provides to the grid. The most impactful regulatory decision for the energy storage industry has come from California, where the California Public Utilities Commission issued a decision that mandates procurement requirements of 1.325 GW for energy storage to 3 investor-own utilities in 4 stages: in 2014, 2016, 2018, and 2020. Furthermore, at the Federal level, FERC’s Order 755, requires the transmission operators to develop pay for performance tariffs for ancillary services. This has had direct impact on the market design of US competitive wholesale markets and the monetization of fast responding grid assets. While this order is technology neutral, it clearly plays into the fast-responding capability of energy storage technologies. Today PJM, CAISO, MISO, NYISO, and NE-ISO have implemented Order 755 and offer new tariff for regulation services based on pay-for-performance principles. Furthermore, FERC Order 784, issued in July 2013 requires transmission providers to consider speed and accuracy in determining the requirements for ancillary services. In November 2013, FERC issued Order 972, which revises the small generator interconnection agreement which declares energy storage as a power source. This order puts energy storage on par with existing generators. This paper will discuss the implementation of FERC’s Pay for Performance Regulation order at all ISOs in the U.S. under FERC regulatory authority (this excludes ERCOT). Also discussed will be the market impacts and overall impacts on the NERC regulation performance indexes. The paper will end with a discussion on the California and Ontario, Canada procurement mandates and the opportunity that it may present to the energy storage industry.

Kintner-Meyer, Michael CW↗

Quantifying the effect of multiple load flexibility strategies on commercial building electricity demand and services via surrogate modeling

The expansion of commercial building demand response as a demand-side management resource for the electric grid necessitates new decision support resources for customers seeking to assess the benefit–risk tradeoffs of possible strategies for energy flexible building operations. To address this need, we, in this study, develop surrogate models that predict the impacts of several load flexibility strategies on commercial building electricity demand and indoor temperature, focusing on offices and retail buildings at multiple scales. The surrogate models are fit to a synthetic database generated via whole building simulations, which establish the relationships between the key operational features of a given strategy and potential changes in building demand and temperature across a variety of contexts. The surrogate models are translated to a Bayesian framework to allow straightforward communication of uncertainty and parameter updating given new evidence. We find strong predictive performance across the suite of models, underscoring the usefulness of the approach in guiding decisions about implementing load flexibility strategies under a particular set of operational and environmental conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Earth System Grid (ESG) Data Node Software Stack

The ESG-CET system consist of two major components: 1) Gateways that support portal services, which serve as interfaces to end-users who can search, discover, and request data and data products, and 2) Data Nodes where the data actually resides. The Data is "published" to the Data Node, which makes the data visible to a Gateway and enables its delivery to end-users. It is expected that Gateways will only be installed by a small number of centers devoted to serving data (e.g., LLNL/PCMDI, NCAR, GFDL, DADC, DKRZ, ANU, JAMSTEC), whereas it is hoped that most climate modeling centers will install the Data Node software through which they can serve their model output.

Williams, D. N.↗

DMS Advanced Applications for Accommodating High Penetrations of DERs and Microgrids

Efficient and effective management of the electric distribution system requires an integrated approach to allow various systems to work in harmony, including distribution management systems (DMS), distributed energy resources (DERs), distributed energy resources management systems, and microgrids. This study highlights some outcomes from a recent project sponsored by the US Department of Energy, Office of Electricity Delivery and Energy Reliability, including information about (i) the architecture of these integrated systems and (ii) expanded functions of two example DMS applications to accommodate DERs: volt-var optimisation and fault location, isolation, and service restoration. In addition, the relevant DER group functions necessary to support communications between the DMS and a microgrid controller in grid-tied mode are identified.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Inverter Functions and Communication Protocols for Distribution Management

This paper aims at identifying the advanced features required by distribution management systems (DMS) service providers to bring inverter-connected distributed energy resources into use as an intelligent grid resource. This work explores the standard functions needed in the future DMS for enterprise integration of distributed energy resources (DER). The important DMS functionalities such as DER management in aggregate groups, including the discovery of capabilities, status monitoring, and dispatch of real and reactive power are addressed in this paper. It is intended to provide the industry with a point of reference for DER integration with other utility applications and to provide guidance to research and standards development organizations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Final Report: High Energy Physics at the Energy Frontier at Louisiana Tech

The Louisiana Tech University High Energy Physics group has developed a research program aimed at experimentally testing the Standard Model of particle physics and searching for new phenomena through a focused set of analyses in collaboration with the ATLAS experiment at the Large Hadron Collider (LHC) at the CERN laboratory in Geneva. This research program includes involvement in the current operation and maintenance of the ATLAS experiment and full involvement in Phase 1 and Phase 2 upgrades in preparation for future high luminosity (HL-LHC) operation of the LHC. Our focus is solely on the ATLAS experiment at the LHC, with some related detector development and software efforts. We have established important service roles on ATLAS in five major areas: Triggers, especially jet triggers; Data Quality monitoring; grid computing; GPU applications for upgrades; and radiation testing for upgrades. Our physics research is focused on multijet measurements and top quark physics in final states containing tau leptons, which we propose to extend into related searches for new phenomena. Focusing on closely related topics in the jet and top analyses and coordinating these analyses in our group has led to high efficiency and increased visibility inside the ATLAS collaboration and beyond. Based on our work in the DØ experiment in Run II of the Fermilab Tevatron Collider, Louisiana Tech has developed a reputation as one of the leading institutions pursuing jet physics studies. Currently we are applying this expertise to the ATLAS experiment, with several multijet analyses in progress.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Modular and Flexible High-Frequency-Link Transformer with a Reduced Device Count and Zero High-Side Devices

In general, large power transformers (LPTs) are not interchangeable with each other and their high costs prohibit extensive spare inventories more so considering that on an average only 1.3 LPTs are manufactured for individual design. The latter pose a further challenge since given that the several existing LPTs are reaching their end of service lives, loss of plurality of such LPTs, that form the backbone of U.S. power grid, will clearly run into the problem of energy security related to the non-availability of sufficient spares (and extended lead time) exacerbated further by the fact that these spares are not interchangeable for installations at different locations. Conventional LPT cost millions of dollars and weighs significantly between approximately 100 and 400 tons. Two raw materials—copper and electrical steel—account for over 50 percent of the total cost of an LPT. In recent years, the price volatility of these two commodities in the global market has affected the manufacturing conditions and procurement strategy for LPTs. Transportation is also an important element of the total LPT cost, because an LPT can weigh significantly and often requires long-distance transport. Transporting an LPT is challenging—its large dimensions and heavy weight pose unique requirements to ensure safe and efficient transportation. Current road, rail, and port conditions are such that transportation is taking more time and becoming more expensive. Conventional low-frequency LPTs typically follow a monolithic approach to design due to historical reasons that need to transition to more modular and flexible (e.g., in voltage, impedance, and power flow) designs with ability to seamlessly/near-seamlessly scale. They should also have the ability to incorporate new technologies without in all cases redoing a LPT design from scratch. Given that the cost of raw materials has continued to increase, next-generation LPTs need to pursue avenues for reducing these costs. An added necessity is to reduce the transportability cost, which is significant in conventional LPTs. Further, given that LPTs are for the long term, they need to be durable, efficient, and fault tolerant with overloading capability. Given this backdrop, the objective and accomplishment of this one-year DOE (SPONSOR) R&D project, led by small business NextWatt LLC (PRIME, Lead PI: Dr. Sudip K. Mazumder) and University of Arkansas at Fayetteville (SUBAWARDEE, PI: Dr. Juan Balda) were to explore the design of a (8 – 20 kHz) high-frequency-link (HFL) based 100-MVA LPT with nominal voltage of 115/69 kV, with $15 - $22 dollars US per kVA when manufactured in “moderate” volume, with 99% energy-conversion efficiency, with 300% reduction in both volume and weight compared to a conventional LPT with the same electrical ratings, with impedance variation greater than 5%, with direct AC/AC power conversion capability, with very-high energy-conversion efficiency (using wide-bandgap SiC based field effect MOSFET devices) over a wide operating temperature, with reduction in both volume and weight with regard to conventional low frequency LPT, and with significant reduction in number of devices compared to state of the art solid state transformer topology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Use of the North Alabama Lightning Mapping Array (NALMA) in the Real-Time Operational Warning Environment During the March 2nd, 2012 Severe Weather Outbreak in Northern Alabama

The North Alabama Lightning Mapping Array (NALMA) is a three-dimensional very high frequency (VHF) detection network consisting of 11 sensors spread across north central Alabama and two sensors located in the Atlanta, Georgia region. The primary advantage of this network is that it detects total lightning, or the combination of both cloud-to-ground and intra-cloud lightning, instead of cloud-to-ground lightning alone. This helps to build a complete picture of storm evolution and development, and can serve as a proxy for storm updraft strength, particularly since intra-cloud lightning makes up the majority of all lightning in a typical thunderstorm. While the NALMA data do not directly indicate severe weather, they can indirectly indicate when a storm is strengthening (weakening) due to increases (decreases) in updraft strength, as the updraft is responsible for charging mechanisms within the storm. Data output are VHF radiation sources, which are produced during lightning breakdown processes. These sources are made into 2x2 km source density grids and are ported into the Advanced Weather Interactive Processing System (AWIPS) for National Weather Service (NWS) offices in Huntsville, AL, Nashville, TN, Morristown, TN, and Birmingham, AL, in near real-time. An increase in sources, or source densities, correlates to increased lightning activity and trends in updraft magnitude as long as the storm is within about 125 km of the center of the LMA network. Operationally, these data have been used at the Huntsville NWS office since early 2003 through a collaborative effort with NASA s Short-term Prediction Research and Transition (SPoRT) Center. Since then, total lightning observations have become an essential tool for forecasters during real-time warning operations. One of the operational advantages of the NALMA is the two-minute temporal resolution of the data. This provides forecasters with two to three updates during a typical volume scan of the WSR-88D radar.

White, Kristopher↗

The effects of digital elevation model resolution on the calculation and predictions of topographic wetness indices.

One of the largest exports in the Southeast U.S. is forest products. Interest in biofuels using forest biomass has increased recently, leading to more research into better forest management BMPs. The USDA Forest Service, along with the Oak Ridge National Laboratory, University of Georgia and Oregon State University are researching the impacts of intensive forest management for biofuels on water quality and quantity at the Savannah River Site in South Carolina. Surface runoff of saturated areas, transporting excess nutrients and contaminants, is a potential water quality issue under investigation. Detailed maps of variable source areas and soil characteristics would therefore be helpful prior to treatment. The availability of remotely sensed and computed digital elevation models (DEMs) and spatial analysis tools make it easy to calculate terrain attributes. These terrain attributes can be used in models to predict saturated areas or other attributes in the landscape. With laser altimetry, an area can be flown to produce very high resolution data, and the resulting data can be resampled into any resolution of DEM desired. Additionally, there exist many maps that are in various resolutions of DEM, such as those acquired from the U.S. Geological Survey. Problems arise when using maps derived from different resolution DEMs. For example, saturated areas can be under or overestimated depending on the resolution used. The purpose of this study was to examine the effects of DEM resolution on the calculation of topographic wetness indices used to predict variable source areas of saturation, and to find the best resolutions to produce prediction maps of soil attributes like nitrogen, carbon, bulk density and soil texture for low-relief, humid-temperate forested hillslopes. Topographic wetness indices were calculated based on the derived terrain attributes, slope and specific catchment area, from five different DEM resolutions. The DEMs were resampled from LiDAR, which is a laser altimetry remote sensing method, obtained from the USDA Forest Service at Savannah River Site. The specific DEM resolutions were chosen because they are common grid cell sizes (10m, 30m, and 50m) used in mapping for management applications and in research. The finer resolutions (2m and 5m) were chosen for the purpose of determining how finer resolutions performed compared with coarser resolutions at predicting wetness and related soil attributes. The wetness indices were compared across DEMs and with each other in terms of quantile and distribution differences, then in terms of how well they each correlated with measured soil attributes. Spatial and non-spatial analyses were performed, and predictions using regression and geostatistics were examined for efficacy relative to each DEM resolution. Trends in the raw data and analysis results were also revealed.

09 BIOMASS FUELS↗

An Evaluation of Energy Storage Options for Nuclear Power

The dynamics of energy generation, delivery, and consumption in the United States continue to change as new energy sources come online and consumers purchase more energy-intensive devices. The percentage of electricity generation from variable renewable energy sources like wind and solar power has grown year after year. Meanwhile, the evolution of electric vehicles, smart devices, and consumer appliances is changing the way that electricity is used. As a result of these trends, nuclear power plants (NPPs) are being asked to operate more flexibly. Newly constructed, advanced nuclear power plants (A-NPPs) will likely need to adapt their business models with these market shifts in mind. In the future, A-NPPs might operate in an electricity system that values flexibility (e.g. fast ramping) more than stability (e.g. baseload supply). The current fleet of NPPs is struggling to remain economically viable in competitive markets that favor low natural gas prices and renewable energy sources with low marginal costs. Rising construction costs and ambiguous national policies have only added to the challenges facing plant operators. The industry as a whole is in decline, with 19 reactors in the process of being decommissioned and 5 of these plants retiring in the past decade. However, NPPs also provide several performance and environmental benefits by maintaining a high capacity factor and generating almost zero greenhouse gas (GHG) emissions over the life cycle of the plant. As more areas of energy consumption in the United States are electrified, NPPs could potentially replace coal and natural gas as a source of heat and power to help decarbonize the U.S. energy mix. Improving the flexibility of newly constructed A-NPPs to increase revenue through market hedging and reduce costs via stable operation was explored in this analysis. The increasing penetration of variable energy resources could contribute to the uncertainty of electricity demand, which could in turn increase the need for dispatchable electricity generating units. This role is currently filled by inexpensive natural gas combined cycle (NGCC) plants, whereas coal and NPPs have traditionally been called upon to provide baseload power by maintaining a constant power output. As wholesale electricity prices continue to fall due to low natural gas prices and federally subsidized renewable energy, this business model has begun to fail, resulting in incidences of NPPs selling electricity at a loss. Since it has not been economically favorable for NPPs to operate flexibly in this situation in the past, due to their low variable costs compared to fossil fuel power plants, NPPs in the United States were not built with this purpose in mind. Therefore, legacy NPPs have had difficulty adapting to these shifting dynamics due to regulatory and technical constraints, coupled with a lack of meaningful experience. NPPs in France have operated in this manner for years, due to a much higher percentage of baseload generators and a lower percentage of fast-ramping NGCC plants. The integration of energy storage technologies (ESTs) alongside newly constructed A-NPPs will be investigated in this analysis as an alternative method for helping NPPs resolve the economic challenges they currently face. Although the deregulation of energy markets in the United States is responsible for much of the increased competition from natural gas and renewable energy that has negatively impacted NPPs, this process has also led to the creation of ancillary service markets. ESTs can provide many of these services, so an integrated energy storage system could supplement both the reliability of the electricity grid and the economic performance of a NPP by bidding into these markets. However, many technical, financial, and regulatory barriers still prevent ESTs from operating profitably in this space. The purpose of this body of work is to compile a transparent database of metrics for available ESTs and identify barriers to widespread deployment. An analytical selection methodology was also developed to identify favorable technologies for integration with specific NPPs based on information supplied by an interested developer. These tools could help reduce the perceived risk surrounding investment in energy storage systems, which could help both NPPs in need of economic assistance and ESTs in need of further research and development.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Reaching Grid Parity Using BP Solar Crystalline Silicon Technology: A Systems Class Application

The primary target market for this program was the residential and commercial PV markets, drawing on BP Solar's premium product and service offerings, brand and marketing strength, and unique routes to market. These two markets were chosen because: (1) in 2005 they represented more than 50% of the overall US PV market; (2) they are the two markets that will likely meet grid parity first; and (3) they are the two market segments in which product development can lead to the added value necessary to generate market growth before reaching grid parity. Federal investment in this program resulted in substantial progress toward the DOE TPP target, providing significant advancements in the following areas: (1) Lower component costs particularly the modules and inverters. (2) Increased availability and lower cost of silicon feedstock. (3) Product specifically developed for residential and commercial applications. (4) Reducing the cost of installation through optimization of the products. (5) Increased value of electricity in mid-term to drive volume increases, via the green grid technology. (6) Large scale manufacture of PV products in the US, generating increased US employment in manufacturing and installation. To achieve these goals BP Solar assembled a team that included suppliers of critical materials, automated equipment developers/manufacturers, inverter and other BOS manufacturers, a utility company, and University research groups. The program addressed all aspects of the crystalline silicon PV business from raw materials (particularly silicon feedstock) through installation of the system on the customers site. By involving the material and equipment vendors, we ensured that supplies of silicon feedstock and other PV specific materials like encapsulation materials (EVA and cover glass) will be available in the quantities required to meet the DOE goals of 5 to 10 GW of installed US PV by 2015 and at the prices necessary for PV systems to reach grid parity in 2015. This final technical report highlights the accomplishments of the BP Solar technical team from 2006 to the end of the project in February 2010. All the main contributors and team members are recognized for this accomplishment and their endeavors are recorded in the twelve main tasks described here.

14 SOLAR ENERGY↗

MPC solution for optimal load shifting for buildings with ON/OFF staged packaged units: Experimental demonstration, and lessons learned

Small and medium-sized commercial buildings (SMCB) are significant demand response resources, and it is important to develop grid-responsive control algorithms that exploit those resources and create financial benefits for building owners and HVAC service providers. Furthermore, unlike large-sized commercial buildings, there is an opportunity to have universally applicable control solutions for many SMCBs since those buildings have a consistent HVAC system configuration: SMCBs are commonly served by multiple-staged air conditioning units controlled by their own thermostats. Despite the demand response potential and scalability, however, very few control solutions are available for SMCBs. Typical model predictive control (MPC) and heuristic control approaches for cooling load shifting that lower thermostat setpoints before an electric price jump are suitable mainly for large-sized commercial buildings where a continuous capacity modulation is possible, e.g., via dampers in variable air volume terminal units. However, those approaches can cause undesired, high peaks for SMCBs due to the nature of ON/OFF unit staging and narrow thermostat deadbands. This could discourage the use of advanced grid-responsive controls for SMCBs due to the concern of high demand charges, and has to be resolved. This paper presents a MPC solution that overcomes this challenge. It has a hierarchical MPC structure where an upper level MPC is responsible for electrical load shifting in response to an electric price signal while a lower level MPC is responsible for coordinating compressor stages to eliminate unnecessary peaks and follows the setpoints determined by the upper level MPC. In this work, two one-month, comprehensive laboratory tests have been carried out to demonstrate load shifting and cost savings for the algorithm. Interesting trade-offs between energy efficiency and load flexibility were observed and are discussed, and lessons learned for applying MPCs for SMCBs are also presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗