Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Focuses”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Dendritic cells focus CTL responses toward highly conserved and topologically important HIV-1 epitopes

During early HIV-1 infection, immunodominant T cell responses to highly variable epitopes lead to the establishment of immune escape virus variants. Here we assessed a type 1-polarized monocyte-derived dendritic cell (MDC1)-based approach to selectively elicit cytotoxic T lymphocyte (CTL) responses against highly conserved and topologically important HIV-1 epitopes in HIV-1-infected individuals from the Thailand RV254/SEARCH 010 cohort who initiated antiretroviral therapy (ART) during early infection (Fiebig stages I-IV). Autologous MDC1 were used as antigen presenting cells to induce in vitro CTL responses against HIV-1 Gag, Pol, Env, and Nef as determined by flow cytometry and ELISpot assay. Ultra-conserved or topologically important antigens were respectively identified using the Epigraph tool and a structure-based network analysis approach and compared to overlapping peptides spanning the Gag proteome. MDC1 presenting either the overlapping Gag, Epigraph, or Network 14-21mer peptide pools consistently activated and expanded HIV-1-specific T cells to epitopes identified at the 9-13mer peptide level. Interestingly, some CTL responses occurred outside known or expected HLA associations, providing evidence of new HLA-associated CTL epitopes. Comparative analyses demonstrated more sequence conservation among Epigraph antigens but a higher magnitude of CTL responses to Network and Gag peptide groups. Importantly, CTL responses against topologically constrained Gag epitopes contained in both the Network and Gag peptide pools were selectively enhanced in the Network pool-initiated cultures. Our study supports the use of MDC1 as a therapeutic strategy to induce and focus CTL responses toward putative fitness-constrained regions of HIV-1 to prevent immune escape and control HIV-1 infection.

60 APPLIED LIFE SCIENCES↗

Nanoadsorbents based on conducting polymer nanocomposites with main focus on polyaniline and its derivatives for removal of heavy metal ions/dyes: A review

Highlights: • Nanoadsorbents based on conductive polymers can remove heavy metal ions/dye. • Contact time, pH, adsorbent dosage and temperature are effective adsorption factors. • Chemical structures of nanoadsorbents play an important role in adsorption. • Adsorption of metal ions on PANI based nanocomposites is of physical type. Water contamination by toxic heavy metal ions and dyes remains a serious public health problem for humans, so attention on specific methods and technologies to remove heavy metal ions and dyes from wastewaters/aqueous solutions are desired. Numerous adsorbents have been reported for the removal of heavy metal ions/dyes from wastewaters/aqueous solutions. Polyaniline (PANI) and its derivatives, as conducting polymers, are good adsorbents to remove various kinds of heavy metal ions and dyes from wastewaters/aqueous solutions. The nanoadsorbents based on PANI and its derivatives have received much consideration, and are extensively reported in literature. This review focuses on the PANI and its derivatives based on nanoadsorbents for water purification. Various types of these nanoadsorbents used for the removal of heavy metal ions/dyes from wastewaters/aqueous solutions are also briefly compared in this review.

54 ENVIRONMENTAL SCIENCES↗

Reviewing flexibility in industrial electrification: Focusing on green ammonia and steel in the United States

The renewable energy transition in the power sector involves a paradigm shift for flexibility. Flexible demand is more attainable than before, while supply flexibility faces new constraints due to the increased share of variable renewable resources. Increased demand flexibility can allow less use of peaking power plants and avoid need for additional capacity. Industrial flexibility could be especially interesting in this regard, as industrial customers are larger on average than other customers and have typically provided the largest share of demand response in the United States. We consider industrial demand, studying characteristics of flexible industrial loads. We then examine the dynamics of change occurring around industrial load flexibility by focusing on two case studies: green ammonia and steel production via electric arc furnaces. Electric arc furnace steel production is an important component of current demand response programs, whereas green ammonia and green fuels offer new paradigms for flexibility. We analyze the structure and functions of the technological innovation systems of load flexibility in those two industries via interviews with twenty-two stakeholders. Here, we conclude that in the United States these technological innovation systems are not well-functioning for industry in general or for steel, but do seem to be present for green ammonia. Additionally, explicit connections between scope two greenhouse gas emissions (those from purchased energy) and flexibility are lacking, and likewise industry stakeholders do not appear to make a connection between decarbonization and load flexibility, thus flexible demand is not viewed as a tool in industrial decarbonization.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A systematic literature review on residential demand response with a focus on opportunities for low-income communities

Demand Response improves efficiency and grid stability, reducing peak load and total system costs. It can potentially contribute to other societal aspects, including mitigating climate change and improving air quality, health, stress levels, and comfort. This paper reviewed the literature on residential demand response programs in the United States, through the lens of the five energy justice principles, identifying and categorizing a set of 165 papers from 1960 to 2024. As a result, we observe significant progress in distributive justice, however, mostly focused on increasing participation rather than attending specific needs of historically marginalized communities. Concordantly, recognition and procedural justice dimensions are lagging, while cosmopolitan justice studies are scarce, underscoring a need to improve the measurement of impacts resulting from the implementation of demand response programs. Future research opportunities include the consolidation of standardized definitions and metrics, to better understand burdens and needs of diverse residential users. In terms of policy, collection and transparent access to standardized data is required as a condition to the design of flexible, customizable, transparent, and easy to navigate demand response programs. As a result, a better understanding of and engagement with customers has the potential to increase adoption rates, persistence in the program, and overall impacts for the system, households, and society.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Proton Therapy as Salvage Treatment for Local Relapse of Prostate Cancer Following Cryosurgery or High-Intensity Focused Ultrasound

Purpose: Local recurrence of prostate cancer after cryosurgery (CS) and high-intensity focused ultrasound (HIFU) is an emerging problem for which optimal management is unknown. Proton therapy (PT) may offer advantages over other local therapeutic options. This article reviews a single institution's experience using PT for salvage of local recurrent disease after HIFU or CS. Methods and Materials: We reviewed the medical records of 21 consecutive patients treated with salvage PT following a local recurrence of prostate cancer after CS (n=12) or HIFU (n=9) between January 2007 and July 2014. Patients were treated to a median dose of 74 Gy(relative biological effectiveness [RBE]; range: 74-82 Gy[RBE]) and 8 patients received androgen deprivation therapy with radiation therapy. Patients were evaluated for quality of life (QOL) by using the Expanded Prostate Index Composite questionnaire and toxicity by using Common Terminology Criteria for Adverse Events, version 3.0, weekly during treatment, every 6 months for 2 years after treatment, and then annually. Results: Median follow-up was 37 months (range: 6-95 months). The 3-year biochemical progression-free survival (bPFS) rate was 77%. The 3-year grade 3 toxicity rate was 17%; however, 2 of these patients had pre-existing grade 3 GU toxicities from their HIFU/CRYO prior to PT. At 1 year, bowel summary, urinary incontinence, and urinary obstructive QOL scores declined, but only the bowel QOL score at 12 months met the minimally important difference threshold. Conclusions: PT achieved a high rate of bPFS with acceptable toxicity and minimal changes in QOL scores compared with baseline pre-PT functions. Although most patients have done fairly well, the study size is small, follow-up is short, and early results suggest that outcomes with PT for salvage after HIFU or CS failure are inferior to outcomes with PT given in the de novo setting with respect to disease control, toxicity, and QOL.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic Resonance–Guided High-Intensity Focused Ultrasound Hyperthermia for Recurrent Rectal Cancer: MR Thermometry Evaluation and Preclinical Validation

Purpose: To evaluate the feasibility of magnetic resonance–guided high-intensity focused ultrasound (MR-HIFU) mild hyperthermia in deep tissue targets for enhancing radiation therapy and chemotherapy in the context of recurrent rectal cancer. A preclinical study was performed to evaluate the safety and performance of MR-HIFU mild hyperthermia. A prospective imaging study was performed in volunteers with rectal cancer to evaluate MR thermometry quality near the rectum and accessibility of rectal tumors using MR-HIFU. Methods and Materials: Mild hyperthermia was performed in pig thigh (9 sonications, 6 pigs) using a clinical MR-HIFU system. Targets near the rectal wall and deep thigh were evaluated. Thermal maps obtained in 6 planes every 3.2 seconds were used to control sonications in 18-mm diameter treatment regions at temperatures of 42°C to 42.5°C for 10 to 60 minutes. Volunteer imaging-only studies to assess the quality of MR thermometry (without heating) were approved by the institutional research ethics board. Anatomic and MR thermometry images were acquired in consenting volunteers with rectal cancer. In 3 of 6 study participants, rectal filling with saline was used to reduce motion-related MR thermometry artifacts near the tumor. Results: In pigs, mean target temperature matched the desired hyperthermia temperature within 0.2°C; temporal standard deviation ≤0.5°C. With optimized control thresholds, no undesired tissue damage was observed. In human volunteers, MR temperature measurements had adequate precision and stability, especially when rectal filling was used to reduce bowel motion. Conclusions: In pigs, MR-HIFU can safely deliver mild hyperthermia (41°C-43°C) to a targeted volume for 30 minutes. In humans, careful patient selection and preparation will enable adequate targeting for recurrent rectal cancers and sufficient MR temperature mapping stability to control mild hyperthermia. These results enable human trials of MR-HIFU hyperthermia.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Focused Ultrasound-Mediated Blood-Brain Barrier Opening Increases Delivery and Efficacy of Etoposide for Glioblastoma Treatment

Glioblastoma (GBM) is a devastating disease. With the current treatment of surgery followed by chemoradiation, outcomes remain poor, with median survival of only 15 months and a 5-year survival rate of 6.8%. A challenge in treating GBM is the heterogeneous integrity of the blood-brain barrier (BBB), which limits the bioavailability of systemic therapies to the brain. There is a growing interest in enhancing drug delivery by opening the BBB with the use of focused ultrasound (FUS). We hypothesize that an FUS-mediated BBB opening can enhance the delivery of etoposide for a therapeutic benefit in GBM.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects of Single-Dose Versus Hypofractionated Focused Radiation on Vertebral Body Structure and Biomechanical Integrity: Development of a Rabbit Radiation-Induced Vertebral Compression Fracture Model

Vertebral compression fracture is a common complication of spinal stereotactic body radiation therapy. Development of an in vivo model is crucial to fully understand how focal radiation treatment affects vertebral integrity and biology at various dose fractionation regimens. We present a clinically relevant animal model to analyze the effects of localized, high-dose radiation on vertebral microstructure and mechanical integrity. Using this model, we test the hypothesis that fractionation of radiation dosing can reduce focused radiation therapy's harmful effects on the spine.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

New Ferritic Steels with Combined Optimal Creep Resistance and Ductility by Coupling Thermodynamic Calculations with Focused Experiments

Two critical issues restricting the applications of NiAl precipitate-strengthened ferritic steels are their poor room temperature ductility and insufficient creep resistance at temperatures higher than 600 C. In this study, a thermodynamic modeling approach is integrated with experiments focused on investigating the ductility and creep resistance of steel alloys based on the Fe-Ni-Al-Cr-Mo multi-component system. The mechanical property studies showed that the creep resistance increases with increasing the volume fraction of B2-ordered precipitates, while the opposite trend was observed for the ductility. Low solubility of Al in the {alpha}-Fe matrix was found to favor a ductility increase. Thermodynamic calculations were used to predict the volume fraction of B2-ordered precipitate and the elemental partitioning to guide the selection of alloy compositions that might exhibit the balanced creep resistance and ductility. Key experiments were then conducted to validate the prediction. This integrated approach was found to be very effective in the alloy development.

36 MATERIALS SCIENCE↗

A fast Huygens sweeping method for capturing paraxial multi-color optical self-focusing in nematic liquid crystals

We propose a numerically efficient algorithm for simulating the multi-color optical self-focusing phenomena in nematic liquid crystals. The propagation of the nematicon is modeled by a parabolic wave equation coupled with a nonlinear elliptic partial differential equation governing the angle between the crystal and the direction of propagation. Numerically, the paraxial parabolic wave equation is solved by a fast Huygens sweeping method, while the nonlinear elliptic PDE is handled by the alternating direction explicit (ADE) method. The overall algorithm is shown to be numerically efficient for computing high frequency beam propagations. - Highlights: • A simple strategy can already improve the fast Huygens sweeping method for high frequency asymptotic solutions. • The Alternating Direction Explicit method can significant improve the computational efficiency. • Numerical solutions match the Fredericks transition.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Three-dimensional microstructural characterization of bulk plutonium and uranium metals using focused ion beam technique

Nuclear forensics requires accurate quantification of discriminating microstructural characteristics of the bulk nuclear material to identify its process history and provenance. Conventional metallographic preparation techniques for bulk plutonium (Pu) and uranium (U) metals are limited to providing information in two-dimension (2D) and do not allow for obtaining depth profile of the material. In this contribution, use of dual-beam focused ion-beam/scanning electron microscopy (FIB-SEM) to investigate the internal microstructure of bulk Pu and U metals is demonstrated. Our results demonstrate that the dual-beam methodology optimally elucidate microstructural features without preparation artifacts, and the three-dimensional (3D) characterization of inner microstructures can reveal salient microstructural features that cannot be observed from conventional metallographic techniques. As a result, examples are shown to demonstrate the benefit of FIB-SEM in improving microstructural characterization of microscopic inclusions, particularly with respect to nuclear forensics.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Understanding the crack formation of graphite particles in cycled commercial lithium-ion batteries by focused ion beam - scanning electron microscopy

Here in this paper, the structure degradation of commercial Lithium-ion battery (LIB) graphite anodes with different cycling numbers and charge rates was investigated by focused ion beam (FIB) and scanning electron microscopy (SEM). The cross-section image of graphite anode by FIB milling shows that cracks, resulted in the volume expansion of graphite electrode during long-term cycling, were formed in parallel with the current collector. The crack occurs in the bulk of graphite particles near the lithium insertion surface, which might derive from the stress induced during lithiation and de-lithiation cycles. Subsequently, crack takes place along grain boundaries of the polycrystalline graphite, but only in the direction parallel with the current collector. Furthermore, fast charge graphite electrodes are more prone to form cracks since the tensile strength of graphite is more likely to be surpassed at higher charge rates. Therefore, for LIBs long-term or high charge rate applications, the tensile strength of graphite anode should be taken into account.

25 ENERGY STORAGE↗

Three-dimensional analysis of coalesced bainite using focused ion beam tomography

A coarse constituent resulting from the coalescence of platelets of bainite has recently been discovered in high-strength steel weld metals. The three-dimensional shape of coalesced bainite has been investigated by serial sectioning using a focused ion beam milling facility supplemented with observations made using field emission gun scanning electron microscopy and light optical microscopy. A compilation of the sections into a three-dimensional model revealed the shape of the coalesced bainite grain to be lath-like with a length in excess of 20 {mu}m.

36 MATERIALS SCIENCE↗

Effects of focused ion beam milling on austenite stability in ferrous alloys

The susceptibility of fcc austenite to transform to bcc during focused ion beam milling was studied in three commercial stainless steels. The alloys investigated, in order of increasing austenite stability, were: (i) a model maraging steel, Sandvik 1RK91; (ii) an AISI 304 austenitic stainless steel; and (iii) AL-6XN, a super-austenitic stainless steel. Small trenches were milled across multiple austenite grains in each alloy using a 30 kV Ga{sup +} ion beam at normal incidence to the specimen surface. The ion beam dose was controlled by varying the trench depth and the beam current. The factors influencing the transformation of fcc austenite to bcc (listed in order of decreasing influence) were found to be: (i) alloy composition (i.e., austenite stability), (ii) ion beam dose (or trench depth), and (iii) crystallographic orientation of the austenite grains. The ion beam current had a negligible influence on the FIB-induced transformation of austenite in these alloys.

36 MATERIALS SCIENCE↗

Novel EBSD preparation method for Cu/Sn microbumps using a focused ion beam

We proposed a novel technique developed from focused ion beam (FIB) polishing for sample preparation of electron backscatter diffraction (EBSD) measurement. A low-angle incident gallium ion beam with a high acceleration voltage of 30 kV was used to eliminate the surface roughness of cross-sectioned microbumps resulting from mechanical polishing. This work demonstrates the application of the FIB polishing technique to solders for a high-quality sample preparation for EBSD measurement after mechanical polishing. - Highlights: Black-Right-Pointing-Pointer The novel FIB technique of sample preparation is fast, effective and low-cost. Black-Right-Pointing-Pointer It can enhance the process precision to the specific area of the sample. Black-Right-Pointing-Pointer It is convenient for analyzing the metallurgy of the microbump in 3DIC packaging. Black-Right-Pointing-Pointer The EBSD image quality can be enhanced by just using a common FIB instrument.

36 MATERIALS SCIENCE↗

Determining the sputter yields of molybdenum in low-index crystal planes via electron backscattered diffraction, focused ion beam and atomic force microscope

Previous literature has used several monocrystalline sputtering targets with various crystalline planes, respectively, to investigate the variations of the sputter yield of materials in different crystalline orientations. This study presents a method to measure the sputtered yields of Mo for the three low-index planes (100), (110), and (111), through using an easily made polycrystalline target. The procedure was firstly to use electron backscattered diffraction to identify the grain positions of the three crystalline planes, and then use a focused ion beam to perform the micro-milling of each identified grain, and finally the sputter yields were calculated from the removed volumes, which were measured by atomic force microscope. Experimental results showed that the sputter yield of the primary orientations for Mo varied as Y{sub (110)} > Y{sub (100)} > Y{sub (111)}, coincidental with the ranking of their planar atomic packing densities. The concept of transparency of ion in the crystalline substance was applied to elucidate these results. In addition, the result of (110) orientation exhibiting higher sputter yield is helpful for us to develop a Mo target with a higher deposition rate for use in industry. By changing the deformation process from straight rolling to cross rolling, the (110) texture intensity of the Mo target was significantly improved, and thus enhanced the deposition rate. - Highlights: • We used EBSD, FIB and AFM to measure the sputter yields of Mo in low-index planes. • The sputter yield of the primary orientations for Mo varied as Y{sub (110)} > Y{sub (100)} > Y{sub (111)}. • The transparency of ion was used to elucidate the differences in the sputter yield. • We improved the sputter rate of polycrystalline Mo target by adjusting its texture.

36 MATERIALS SCIENCE↗

Characterization of TiN, TiC and Ti(C,N) in titanium-alloyed ferritic chromium steels focusing on the significance of different particle morphologies

Titanium-alloyed ferritic chromium steels are a competitive option to classical austenitic stainless steels owing to their similar corrosion resistance. The addition of titanium significantly influences their final steel cleanliness. The present contribution focuses on the detailed metallographic characterization of titanium nitrides, titanium carbides and titanium carbonitrides with regard to their size, morphology and composition. The methods used are manual and automated Scanning Electron Microscopy with Energy Dispersive X-ray Spectroscopy as well as optical microscopy. Additional thermodynamic calculations are performed to explain the precipitation procedure of the analyzed titanium nitrides. The analyses showed that homogeneous nucleation is decisive at an early process stage after the addition of titanium. Heterogeneous nucleation gets crucial with ongoing process time and essentially influences the final inclusion size of titanium nitrides. A detailed investigation of the nuclei for heterogeneous nucleation with automated Scanning Electron Microscopy proved to be difficult due to their small size. Manual Scanning Electron Microscopy and optical microscopy have to be applied. Furthermore, it was found that during solidification an additional layer around an existing titanium nitride can be formed which changes the final inclusion morphology significantly. These layers are also characterized in detail. Based on these different inclusion morphologies, in combination with thermodynamic results, tendencies regarding the formation and modification time of titanium containing inclusions in ferritic chromium steels are derived. - Graphical abstract: Display Omitted - Highlights: • The formation and modification of TiN in the steel 1.4520 was examined. • Heterogeneous nucleation essentially influences the final steel cleanliness. • In most cases heterogeneous nuclei in TiN inclusions are magnesium based. • Particle morphology provides important information on inclusion formation.

36 MATERIALS SCIENCE↗

Electron backscatter diffraction studies of focused ion beam induced phase transformation in cobalt

A focused ion beam microscope was used to induce cubic to hexagonal phase transformation in a cobalt alloy, of similar composition to that of the binder phase in a hardmetal, in a controlled manner at 0°, 45° and 80° ion incident angles. The cobalt had an average grain size of ~ 20 μm, allowing multiple orientations to be studied, exposed to a range of doses between 6 × 10{sup 7} and 2 × 10{sup 10} ions/μm{sup 2}. Electron backscatter diffraction (EBSD) was used to determine the original and induced phase orientations, and area fractions, before and after the ion beam exposure. On average, less phase transformation was observed at higher incident angles and after lower ion doses. However there was an orientation effect where grains with an orientation close to (111) planes were most susceptible to phase transformation, and (101) the least, where grains partially and fully transformed at varying ion doses. - Highlights: •Ion-induced phase change in FCC cobalt was observed at multiple incidence angles. •EBSD was used to study the relationship between grain orientation and transformation. •Custom software analysed ion dose and phase change with respect to grain orientation. •A predictive capability of ion-induced phase change in cobalt was enabled.

36 MATERIALS SCIENCE↗