Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Flow loop”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Advanced Metering Infrastructure for Distribution Planning and Operation: Closing the Loop on Grid-Edge Visibility

In the recent history of electric utilities, the potential to have visibility of the grid edge is gaining significance for the reliable planning and operation of a clean energy smart grid. Before the recent large-scale customer adoption of distributed energy resources (DERs), distribution networks were planned with a simpler fit-and-forget philosophy. The importance of customer-sited DERs to achieve climate change goals marks a major shift for utility operations. Changes to traditional fit-and-forget planning paradigms require better availability of grid-edge data. Smart metering is an enterprise-wide tool that is enabling visibility when and where it has been most needed. As of 2020, the rollout of smart metering, or advanced metering infrastructure (AMI), had reached more than 100 million meters in the United States, and nearly half of all electricity customers are now equipped with a smart meter (Figure 1). Smart meters are quickly becoming a ubiquitous data capture feature of smart grids. AMI enables utilities to record and measure electricity usage and power-flow metrics at a minimum of hourly intervals and at least once a day. At a minimum, AMI enables interval metering, automatic meter reading enabling accurate and time-interval billing, and the ability to provide feedback on customer energy consumption.

advanced metering infrastructure↗

Closing the loop: model-predictive control for a closed-circuit reverse osmosis system

This article presents a model-predictive controller (MPC) for the maximization of the energy efficiency of a closed-circuit desalination reverse osmosis (CCRO) system. CCRO is a process for producing drinking water that is based on a cyclic operation with the following two phases: (a) filtration and (b) drain. In this article, we test model predictive control for optimal control of this process. The most important features of our approach are as follows: (a) the selection of a model structure that enables reliable forecasts of the filtration phase (up to 3 h), (b) an on-line model calibration strategy that ensures model forecast reliability, and (c) the satisfaction of equipment safety and operational constraints on the selected setpoints. We challenge this through deliberate introduction of changes in the unmeasured feed concentration and the applied constraints. Our results indicate that frequent model parameter updates are critical to maintain model reliability for MPC purposes. In addition, we illustrate that parameter identifiability is not guaranteed and that deliberate variation in flow rates is necessary even though the process never operates in steady state. Finally, MPC can compute flow rate setpoints that maximize the energy efficiency of the CCRO process while satisfying the applicable equipment and safety constraints.

closed-circuit reverse osmosis↗

INVESTIGATION OF CHROMOSPHERIC EVAPORATION IN A NEUPERT-TYPE SOLAR FLARE

The Neupert effect implies a flare model in which the hard X-rays (HXRs) are produced by energetic electrons via electron-ion bremsstrahlung as they lose their energies in the chromosphere, while the soft X-rays (SXRs) are produced by thermal bremsstrahlung from 'chromospheric evaporation' due to plasma being heated by those same electrons. Based on this concept, we investigate the evidence for chromospheric evaporation in a Neupert-type flare on 2004 October 30. First, we demonstrate that this event is consistent with the Neupert effect. Using the RHESSI data, both thermal and nonthermal energies are derived after the onset of this flare. The high correlation between the derivative of the SXRs and HXRs and between the derivative of the thermal energy and nonthermal energy indicates that the 2004 October 30 flare is a Neupert-type event. Second, chromospheric evaporation is necessarily expected during the flare's rising phase. We analyze RHESSI images at different energies and different times around the flare maximum. The HXR emission tends to move the footpoints close to each other, finally merging them into a single source with the same position as the loop-top source. When the projection effect (due to this event being near the disk center) is taken into account, this fact can be regarded as the signature of chromospheric evaporation in the X-ray observations. RHESSI observations show three kinds of evidence that are consistent with the evaporation model. First, at a given instant, the higher energy X-rays originate from the deeper layers of the atmosphere or further away from the loop top. Second, in a given energy band, i.e., at 20-30 keV, the earlier X-rays originate from the deeper layers or further away from the loop top. Third, the X-ray footpoint sources at higher energies disappear at later times. Based on these characteristics, chromospheric evaporation took about 100 s for the 2004 October 30 flare. X-rays at all energy bands do not show evidence of evaporation probably because measurements are the most sensitive only between 12 and 30 keV. After measuring the source scale as a function of time, we roughly estimate the shrinkage velocities at different energies, for instance, 238 km s{sup -1} for 12-15 keV, 285 km s{sup -1} for 15-20 keV, and 846 km s{sup -1} for 20-30 keV. If the evaporation processes primarily contribute to the source shrinkage, these values are considered as the evaporation velocities, indicating that the evaporation flow would be faster during the latter part of flare.

79 ASTRONOMY AND ASTROPHYSICS↗

Exploring Plasma Heating in the Current Sheet Region in a Three-dimensional Coronal Mass Ejection Simulation

We simulate a coronal mass ejection using a three-dimensional magnetohydrodynamic code that includes coronal heating, thermal conduction, and radiative cooling in the energy equation. The magnetic flux distribution at 1 Rs is produced by a localized subsurface dipole superimposed on a global dipole field, mimicking the presence of an active region within the global corona. Transverse electric fields are applied near the polarity inversion line to introduce a transverse magnetic field, followed by the imposition of a converging flow to form and destabilize a flux rope, producing an eruption. We examine the quantities responsible for plasma heating and cooling during the eruption, including thermal conduction, radiation, adiabatic effects, coronal heating, and ohmic heating. We find that ohmic heating is an important contributor to hot temperatures in the current sheet region early in the eruption, but in the late phase, adiabatic compression plays an important role in heating the plasma there. Thermal conduction also plays an important role in the transport of thermal energy away from the current sheet region throughout the reconnection process, producing a “thermal halo” and widening the region of high temperatures. We simulate emission from solar telescopes for this eruption and find that there is evidence for emission from heated plasma above the flare loops late in the eruption, when the adiabatic heating is the dominant heating term. These results provide an explanation for hot supra-arcade plasma sheets that are often observed in X-rays and extreme ultraviolet wavelengths during the decay phase of large flares.

79 ASTRONOMY AND ASTROPHYSICS↗

Supercharger cooling means

According to the present invention, a rotary blower or supercharger includes a recirculation loop for readmitting pressurized outlet gas back into the rotor chambers, and cooling means for cooling the pressurized outlet gas before it is readmitted into the rotor chambers, thereby providing a supercharger having a lower operating temperature and a higher operating pressure capability. In the preferred embodiment of the present invention, a supercharger includes a housing assembly defining first and second transversely overlapping cylindrical chambers. The housing defines an inlet port for the inflow of an inlet gas, and an outlet port for the outflow of the outlet gas. The supercharger further has first and second meshed, lobed rotors respectively disposed in the chambers for counter rotation about axes substantially coincident with the chamber axes. According to the present invention, the housing further includes a recirculation port and a recirculation flow path for recirculation of a portion of outlet gas flowing out of the outlet port back into cylindrical chamber. The recirculation flow path further including cooling means for cooling of at least a portion of the outlet gas, thereby providing a cooler operating supercharger.

Mendler, III, Edward Charles↗

Quench propagation in the HOM damper of the 56 MHz cavity

The aim of this report is to summarize a study of the propagation of a quench in a HOM damper probe of the 56 MHz superconducting storage cavity for RHIC and provide guidance for machine protection. The 56 MHz cavity [1] is designed to operate as a beam-driven superconducting quarter-wave resonator in the RHIC ring. Four Higher Order Mode (HOM) dampers [2] are used to prevent beam instabilities [3] in RHIC. These are inserted in the back wall of the cavity (the high magnetic field region) through ports that also serve for rinsing the cavity with high-pressure deionized water as well as the fundamental power coupler and pick-up ports. Figure 1 shows the outline of the cavity [4,5]. The HOM damper probe has a magnetic coupling loop which penetrates the cavity as shown in Figure 2 [5]. The loop is cooled by conduction to the 4.3K helium system, thus any sudden, significant amount of heat dumped on the loop will cause local heating. The peak magnetic field on the loop can reach about 7.4 x 10{sup 4} amperes per meter at a cavity voltage of 2.5 MV [5]. The scenario we present here is that a small region on the loop quenches. We can calculate the current driving the cavity using the RHIC parameters and get the magnetic field as a function of the current, the cavity's intrinsic Q and detuning parameter, however it turns out that within the time relevant for the quench development (a fraction of a second) the cavity field does not change sufficiently to warrant this extra computation. Thus we can assume that the field over the loop is constant. The damper loop dimensions are not so important, however its cross section is. In the following we assume that the loop's cross-section is 2 cm by 0.3 cm. It is actually rounded in cross section (sharp corners avoided) but we will approximate it as square. The material parameters taken for the niobium loop (assuming high RRR of about 200) are given in the following stepwise linear approximations. The surface resistivity in ohms as a function of temperature in degrees Kelvin is given in Figure 3, the thermal conductivity in watt per degree meter as a function of temperature is given in Figure 4 and the heat capacity in Joule per kg as a function of temperature is given in Figure 5.

43 PARTICLE ACCELERATORS↗

High precision tests of QCD without scale or scheme ambiguities: The 40th anniversary of the Brodsky–Lepage–Mackenzie method

A key issue in making precise predictions in QCD is the uncertainty in setting the renormalization scale μ r and thus determining the correct values of the QCD running coupling α s (μ r ) at each order in the perturbative expansion of a QCD observable. It has often been conventional to simply set the renormalization scale to the typical scale of the process Q and vary it in the range μ r $\in$ [Q/2, 2Q] in order to estimate the theoretical error. This is the practice of Conventional Scale Setting (CSS). The resulting CSS prediction will however depend on the theorist’s choice of renormalization scheme and the resulting pQCD series will diverge factorially. It will also disagree with renormalization scale setting used in QED and electroweak theory thus precluding grand unification. A solution to the renormalization scale-setting problem is offered by the Principle of Maximum Conformality (PMC), which provides a systematic way to eliminate the renormalization scale-and-scheme dependence in perturbative calculations. The PMC method has rigorous theoretical foundations, it satisfies Renormalization Group Invariance (RGI) and preserves all self-consistency conditions derived from the renormalization group. The PMC cancels the renormalon growth, reduces to the Gell-Mann–Low scheme in the N c → 0 Abelian limit and leads to scale- and scheme-invariant results. The PMC has now been successfully applied to many high-energy processes. In this article we summarize recent developments and results in solving the renormalization scale and scheme ambiguities in perturbative QCD. In particular, we present a recently developed method the PMC ∞ and its applications, comparing the results with CSS. The method preserves the property of renormalizable SU(N)/U(1) gauge theories defined as Intrinsic Conformality (iCF). This property underlies the scale invariance of physical observables and leads to a remarkably efficient method to solve the conventional renormalization scale ambiguity at every order in pQCD. This new method reflects the underlying conformal properties displayed by pQCD at NNLO, eliminates the scheme dependence of pQCD predictions and is consistent with the general properties of the PMC. A new method to identify conformal and β-terms, which can be applied either to numerical or to theoretical calculations is also shown. We present results for the thrust and C-parameter distributions in e + e - annihilation showing errors and comparison with the CSS. We also show results for a recent innovative comparison between the CSS and the PMC ∞ applied to the thrust distribution investigating both the QCD conformal window and the QED N c → 0 limit. In order to determine the thrust distribution along the entire renormalization group flow from the highest energies to zero energy, we consider the number of flavors near the upper boundary of the conformal window. In this flavor-number regime the theory develops a perturbative infrared interacting fixed point. These results show that PMC ∞ leads to higher precision and introduces new interesting features in the PMC. In fact, this method preserves with continuity the position of the peak, showing perfect agreement with the experimental data already at NNLO. We also show a detailed comparison of the PMC ∞ with the other PMC approaches: the multi-scale-setting approach (PMCm) and the single-scale-setting approach (PMCs) by comparing their predictions for three important fully integrated quantities R e+e- , R$_Τ$ and Γ (H→$b\bar{b}$) up to the four-loop accuracy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Integrating High Penetrations of PV into Southern California: Year 2 Project Update; Preprint

Southern California Edison (SCE) is well into a five-year project to install a total of 500 MW of distributed photovoltaic (PV) energy within its utility service territory. Typical installations to date are 1-3 MW peak rooftop PV systems that interconnect to medium-voltage urban distribution circuits or larger (5 MW peak) ground-mounted systems that connect to medium-voltage rural distributioncircuits. Some of the PV system interconnections have resulted in distribution circuits that have a significant amount of PV generation compared to customer load, resulting in high-penetration PV integration scenarios. The National Renewable Energy Laboratory (NREL) and SCE have assembled a team of distribution modeling, resource assessment, and PV inverter technology experts in order toinvestigate a few of the high-penetration PV distribution circuits. Currently, the distribution circuits being studied include an urban circuit with a PV penetration of approximately 46% and a rural circuit with a PV penetration of approximately 60%. In both cases, power flow on the circuit reverses direction, compared to traditional circuit operation, during periods of high PV power productionand low circuit loading. Research efforts during year two of the five-year project were focused on modeling the distribution system level impacts of high-penetration PV integrations, the development and installation of distribution circuit data acquisition equipment appropriate for quantifying the impacts of high-penetration PV integrations, and investigating high-penetration PV impactmitigation strategies. This paper outlines these research efforts and discusses the following activities in more detail: the development of a quasi-static time-series test feeder for evaluating high-penetration PV integration modeling tools; the advanced inverter functions being investigated for deployment in the project's field demonstration and a power hardware-in-loop test of a 500-kW PVinverter implementing a limited set of advanced inverter functions.

14 SOLAR ENERGY↗

OSPREY Model

The absence of industrial scale nuclear fuel reprocessing in the U.S. has precluded the necessary driver for developing the advanced simulation capability now prevalent in so many other countries. Thus, it is essential to model complex series of unit operations to simulate, understand, and predict inherent transient behavior and feedback loops. A capability of accurately simulating the dynamic behavior of advanced fuel cycle separation processes will provide substantial cost savings and many technical benefits. The specific fuel cycle separation process discussed in this report is the off-gas treatment system. The off-gas separation consists of a series of scrubbers and adsorption beds to capture constituents of interest. Dynamic models are being developed to simulate each unit operation involved so each unit operation can be used as a stand-alone model and in series with multiple others. Currently, an adsorption model has been developed within Multi-physics Object Oriented Simulation Environment (MOOSE) developed at the Idaho National Laboratory (INL). Off-gas Separation and REcoverY (OSPREY) models the adsorption of off-gas constituents for dispersed plug flow in a packed bed under non-isothermal and non-isobaric conditions. Inputs to the model include gas, sorbent, and column properties, equilibrium and kinetic data, and inlet conditions. The simulation outputs component concentrations along the column length as a function of time from which breakthrough data is obtained. The breakthrough data can be used to determine bed capacity, which in turn can be used to size columns. It also outputs temperature along the column length as a function of time and pressure drop along the column length. Experimental data and parameters were input into the adsorption model to develop models specific for krypton adsorption. The same can be done for iodine, xenon, and tritium. The model will be validated with experimental breakthrough curves. Customers will be given access to OSPREY to used and evaluate the model.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Balancing Hydronic Systems in Multifamily Buildings

In multifamily hydronic systems, temperature imbalance may be caused by undersized piping, improperly adjusted balancing valves, inefficient water temperature and flow levels, and owner/occupant interaction with the boilers, distribution, and controls. The imbalance leads to tenant discomfort, higher energy use intensity, and inefficient building operation. This research, conducted by Building America team Partnership for Advanced Residential Retrofit, explores cost-effective distribution upgrades and balancing measures in multifamily hydronic systems, providing a resource to contractors, auditors, and building owners on best practices to improve tenant comfort and lower operating costs. The team surveyed existing knowledge on cost-effective retrofits for optimizing distribution in typical multifamily hydronic systems, with the aim of identifying common situations and solutions, and then conducted case studies on two Chicago area buildings with known balancing issues in order to quantify the extent of temperature imbalance. At one of these buildings a booster pump was installed on a loop to an underheated wing of the building. This study found that unit temperature in a multifamily hydronic building can vary as much as 61°F, particularly if windows are opened or tenants use intermittent supplemental heating sources like oven ranges. Average temperature spread at the building as a result of this retrofit decreased from 22.1°F to 15.5°F.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

MELCOR Deposition Models Applied to Noble Metals

Noble metals are chemically inert elements that form particles that can circulate around the fuel loop of a liquid-fueled molten salt reactor (LF-MSR). Due to their health-hazardous abilities, it is important to track these elements and to understand their contributions to source term during a reaction, particularly for Te as it decays into iodine. This report describes three solid deposition models that were implemented into the MELCOR reactor modeling code. The models that were implemented were Dittus-Boelter for turbulent fluid deposition, Talbot thermophoretic transport equation and Richardson-Zaki gravitational deposition. These closures were used to calculate the mass transfer coefficient and was compared to those reported for the Molten Salt Reactor Experiment (MSRE). The impacts of salt, operation and particle parameters on how they affect solid deposition are described, and found that solid deposition is strongly dependent on salt flow and viscosity, as well as particle diffusion rate and size. The conclusions form the basis for activities to be carried out in FY26 and for pursuit of future activities.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A high-velocity cloud impact forming a supershell in the Milky Way

Neutral atomic hydrogen (H i) gas in interstellar space is largely organized into filaments, loops, and shells, the most prominent of which are “supershells.” These gigantic structures, which require ≳ 3× 10{sup 52} erg to form, are generally thought to be produced by either the explosion of multiple supernovae (SNe) in OB associations or, alternatively, by the impact of high-velocity clouds (HVCs) falling into the Galactic disk. Here, we report the detection of a kiloparsec (kpc)-size supershell in the outskirts of the Milky Way with the compact HVC 040 + 01−282 (hereafter, CHVC040) at its geometrical center using the “Inner-Galaxy Arecibo L-band Feed Array” H i 21 cm survey data. The morphological and physical properties of both objects suggest that CHVC040, which is either a fragment of a nearby disrupted galaxy or a cloud that originated from an intergalactic accreting flow, collided with the disk ∼5 Myr ago to form the supershell. Our results show that some compact HVCs can survive their trip through the Galactic halo and inject energy and momentum into the Milky Way disk.

79 ASTRONOMY AND ASTROPHYSICS↗

Preliminary Experimental Results of Integrated Gasification Fuel Cell Operation Using Hardware Simulation

A newly developed integrated gasification fuel cell (IGFC) hybrid system concept has been tested using the Hybrid Performance (Hyper) project hardware-based simulation facility at the U.S. Department of Energy, National Energy Technology Laboratory. The cathode-loop hardware facility, previously connected to the real-time fuel cell model, was integrated with a real-time model of a gasifier of solid (biomass and fossil) fuel. The fuel cells are operated at the compressor delivery pressure, and they are fueled by an updraft atmospheric gasifier, through the syngas conditioning train for tar removal and syngas compression. The system was brought to steady state; then several perturbations in open loop (variable speed) and closed loop (constant speed) were performed in order to characterize the IGFC behavior. Coupled experiments and computations have shown the feasibility of relatively fast control of the plant as well as a possible mitigation strategy to reduce the thermal stress on the fuel cells as a consequence of load variation and change in gasifier operating conditions. Results also provided an insight into the different features of variable versus constant speed operation of the gas turbine section.

10 SYNTHETIC FUELS↗

Field‐Induced Ferroelectric Phase Evolution During Polarization “Wake‐Up” in Hf 0.5 Zr 0.5 O 2 Thin Film Capacitors

Abstract As an emerging nonvolatile memory technology, HfO 2 ‐based ferroelectrics exhibit excellent compatibility with silicon CMOS process flows; however, the reliability of polarization switching in these materials remains a major challenge. During repeated field programming and erase of the polarization state of initially pristine HfO 2 ‐based ferroelectric capacitors, the magnitude of the measured polarization increases, a phenomenon known as “wake‐up”. In this study, the authors attempt to understand what causes the wake‐up effect in Hf 0.5 Zr 0.5 O 2 (HZO) capacitors using nondestructive methods that probe statistically significant sample volumes. Synchrotron X‐ray diffraction reveals a concerted shift in HZO Bragg peak position as a function of polarization switching cycle number in films prepared under conditions such that they exhibit extremely large (≈3000%) wake‐up. In contrast, a control sample with insignificant wake‐up shows no such peak shift. Capacitance – voltage measurements show evolution in the capacitance loop with switching cycle number for the wake‐up sample and no change for the control sample. Piezoresponse force microscopy measurements are utilized to visualize the domain switching with wake‐up. The combination of these observations clearly demonstrates that wake‐up is caused by a field‐driven phase transformation of the tetragonal phase to the metastable ferroelectric orthorhombic phase during polarization switching of HZO capacitors.

36 MATERIALS SCIENCE↗

High-Fidelity Numerical Investigation on Elucidating Sodium Heat Transfer Characteristics for 37-Pin Wire-Wrapped Fuel Bundle in the PLANDTL Facility

This study involved a Reynolds-averaged Navier-Stokes- (RANS-) based computational fluid dynamics (CFD) analysis of the 37-pin wire-wrapped fuel bundle of the PNC Plant dynamics test loop (PLANDTL) facility. Previously, mainly the hydrodynamic phenomena of the wire-wrapped fuel bundle were analyzed, but the present study additionally included heat transfer analysis through conjugate heat transfer. The main purpose of the study was to benchmark the experimental data of the PLANDTL 37-pin wire-wrapped fuel bundle to investigate the heat transfer phenomena. In addition, the aim was to verify the accuracy of the RANS-based CFD analysis method using the STAR-CCM+ simulation software in comparison with the experimental data. The grid used for verification was an innovative grid system consisting of hexahedra using Fortran-based code. The development of the RANS-based CFD methodology included grid sensitivity analysis, turbulence model sensitivity analysis, and turbulent Prandtl number sensitivity analysis. Information on the temperature, mass flow rate, and area of the CFD results for each subchannel was provided for the top of the heated section and is expected to serve as a reference for future studies aiming to perform the validation and verification of a PLANDTL facility. In addition, the dependence of the peak temperature on the azimuth angle of each pin was analyzed.

97 MATHEMATICS AND COMPUTING↗

SERIIUS-MAGEEP Visiting Scholars Program

Recent studies have assessed closed-loop supercritical carbon dioxide (s-CO 2 ) Brayton cycles to be a higher energy-density system in comparison to equivalent superheated steam Rankine systems. At turbine inlet conditions of 700°C and 20 MPa, a cycle thermal efficiency of ~50% can be achieved. Achieving these high efficiencies will help concentrating solar power (CSP) technologies to become a competitive alternative to current power generation methods. To incorporate an s-CO 2 Brayton power cycle in a solar power tower system, the development of a solar receiver capable of providing an outlet temperature of 700°C (at 20 MPa) is necessary. To satisfy the temperature requirements of an s-CO 2 Brayton cycle with recuperation and recompression, the s-CO 2 must undergo a temperature rise of ~200°C as it flows through the solar receiver. The main objective is to develop an optical-thermal-fluid and structural model to validate a tubular receiver that will receive a heat input ~0.33 MWth from the heliostat field at the National Solar Thermal Test Facility (NSTTF), Albuquerque, NM, USA. We also commenced the development of computational models and testing of air receivers being developed by the Indian Institute of Science (IISc) and the Indian Institute of Technology in Bombay (IIT-B). The helical tubular receiver is expected to counteract the effect of thermal expansion while using a cavity to reduce the radiative and convective losses. Initially, this receiver will be tested for a temperature range of 100-300°C under 1 MPa of pressurized air. The helical air receiver will be exposed to 10kWth to achieve a temperature rise of ~200°C. Preliminary tests to validate the modeling will be performed before the design and construction of a larger scale receiver. Lastly, I focused on the development of a new computational tool that would allow us to perform a nodal creep-fatigue analysis on the receivers and heat exchangers being developed. This tool was developed using MATLAB and is capable of processing the results obtained from ANSYS Fluent and Structural combined, which was limited when using commercial software. The main advantage of this code is that it can be modified to run in parallel making it more affordable and faster compared to commercial codes available. The code is in the process of validation and is currently being compared to nCode Design Life.

25 ENERGY STORAGE↗

Online Optimization as a Feedback Controller: Stability and Tracking

This paper develops and analyzes feedback-based online optimization methods to regulate the output of a linear time-invariant (LTI) dynamical system to the optimal solution of a time-varying convex optimization problem. The design of the algorithm is based on continuous-time primal-dual dynamics, properly modified to incorporate feedback from the LTI dynamical system, applied to a proximal augmented Lagrangian function. The resultant closed-loop algorithm tracks the solution of the time-varying optimization problem without requiring knowledge of (time-varying) disturbances in the dynamical system. The analysis leverages integral quadratic constraints to provide linear matrix inequality (LMI) conditions that guarantee global exponential stability and bounded tracking error. Analytical results show that, under a sufficient time-scale separation between the dynamics of the LTI dynamical system and the algorithm, the LMI conditions can be always satisfied. The paper further proposes a modified algorithm that can track an approximate solution trajectory of the constrained optimization problem under less restrictive assumptions. As an illustrative example, the proposed algorithms are showcased for power transmission systems, to compress the time scales between secondary and tertiary control, and allow to simultaneously power re-balancing and tracking of DC optimal power flow points.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimization of a uranyl nitrate passive neutron counter

Safeguarding natural uranium as it enters the fuel cycle has become a priority for the safeguards community in recent years. Uranyl nitrate is a material of interest in this endeavor because it is normally a step in the process from converting uranium ores to more concentrated forms like UO{sub 2} and U{sub 3}O{sub 8}. This paper will detail the improvements and design optimizations made for a uranyl nitrate neutron detector. The original design of the detector was based on standard neutron counter designs and featured 2 rings of He-3 tubes fully moderated and shielded from background. Several areas for enhancement were identified after months of testing in three different locations. An operating uranyl nitrate facility was included as one of the test locations. Three significant upgrades to the counter addressed in the redesign were: real time background detection, counter reliability improvements, and optimization of the detector design for the detection of neutrons emitted by the uranyl nitrate flowing through the monitored process pipe. The optimized detector design includes significant electronics upgrades, the ability to detect neutrons (background and signal) with 36 degree spatial resolution around the process pipe for signal and 45 degree spatial resolution for background, inner and outer rings of He-3 tubes for real time background corrections, and notably more reliable cabling. Monte Carlo N-Particle (MCNP) modeling was used to optimize the signal (neutrons from uranyl nitrate in the monitored process pipe) to noise (background neutrons from all sources) ratio of the inner ring of He-3 tubes. Additionally, MCNP modeling maximized noise to signal on the outer ring of He-3 tubes. Details of the detector optimization as well as all the additional detector enhancements will be discussed. The neutron counter will be field tested on the Uranyl Nitrate Calibration Loop Equipment (UNCLE) facility at Oak Ridge National Laboratory (ORNL).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗